ARRT Radiation Therapy Practice Test

ARRT Radiation Therapy Certification and Registration Examination

ARRT Radiation Therapy overview

  • 200 practice questions
  • 32 flashcards
  • 5 study guide topics
  • 38 key terms

What you'll study

  • Patient Care and Education20%
  • Safety20%
  • Treatment Planning20%
  • Radiation Treatment Delivery20%
  • Dosimetry and Quality Assurance20%

The ARRT Radiation Therapy credential - R.T.(T) - is a national certification and registration offered by the American Registry of Radiologic Technologists for technologists who perform radiation therapy. ARRT describes itself as a leading credentialing organization offering certification and registration across radiologic disciplines, and radiation therapy is listed among its primary credentials. The credential is intended for practitioners who want to demonstrate competence and a commitment to high standards of patient care; it is distinct from state licensure, which ARRT treats as a separate topic.

Exam content reflects the scope of radiation therapy practice: patient care and education, safety, treatment planning, radiation treatment delivery, and dosimetry and quality assurance. Questions test application and judgment, not just recall, so preparation should combine content review with clinical reasoning and ethics review. Use the current ARRT application handbook and exam content specifications as your authoritative source for eligibility, exam-day rules, and scoring. Build a study schedule around weak domains, practice applying safety and planning concepts to scenarios, and reserve time for dosimetry calculations and QA principles. This page is an independent study resource and is not affiliated with or endorsed by ARRT.

Common mistakes

Treating the schedule/room board as the identity check and beginning setup before two independent identifiers (name plus date of birth or medical record number) are matched against the patient's ID band and the prescription.

Candidates memorize "two identifiers" as a phrase and treat verification as a formality when the patient is a familiar, recurring face on a busy schedule; the exam tests whether verification happens before positioning and is repeated at each fraction.

What to do instead

Practice the sequence aloud: identify, then position. Answer identity items by naming both identifiers and stating they occur before the patient is moved onto the couch and again before beam-on.

Answering patient-education items with what the therapist wants the patient to know (technique details, machine settings) instead of what the patient needs (what to expect, side-effect management, when to call), and omitting the documentation or teach-back step from the answer.

Technical training biases candidates toward physics and machinery explanations; education items look soft, so they get skimmed and answered from general instinct about "being nice."

What to do instead

Frame every education question as: what to tell, how to confirm understanding (teach-back), and where it is documented. Reject any option that discloses unnecessary technical detail or leaves out follow-up.

Computing shielding workload (W) or barrier transmission using mA-min/week at the wrong distance, forgetting to separate primary from secondary leakage and scatter, or dropping the occupancy factor and use factor from the product.

The formulas are short, so candidates assemble them from memory without tracking units; mA-min per week, dose rate at 1 m, and distance in meters get mixed, and secondary barriers get solved with the primary equation.

What to do instead

Write the units next to every symbol before multiplying, and label the barrier type first (primary = use factor, secondary = leakage plus patient scatter). Check that the answer's units are the final dose and not an intermediate.

Handling time-distance-shielding and source-decay items without converting distances or time bases first, for example using 1 m dose rate with a 40 cm distance or leaving half-life decay in the wrong direction (assuming the source is stronger than its calibration activity).

These items appear arithmetic-simple, so candidates jump to the formula and forget that inverse square requires consistent length units and that a source only gets weaker with time.

What to do instead

Convert to a single unit system and label whether the distance is in cm or m before computing; for decay, state in words whether activity should be higher or lower than the calibration value and reject any result that points the wrong way.

Converting percent depth dose to tissue maximum ratio (or back) by simply swapping the numbers, ignoring that PDD is referenced to a fixed SSD while TMR is referenced to the depth of maximum dose

Both are percentages at depth, so they feel interchangeable; the inverse-square correction term that links them is the step most often dropped under time pressure.

What to do instead

Memorize the relationship as TMR = PDD x (SPD / (SSD + d))^2, where SPD = SSD + dmax, and know that the factor is always greater than 1 in that direction, since TMR exceeds PDD at depth.

Reading isodose distributions and plan printouts without first identifying the normalization point and prescription line, then reporting coverage or hot spots relative to the wrong reference.

Candidates scan the colors and numbers for the target outline and answer from visual impression; normalization conventions (max dose versus a specified point versus a mean) are the part they skip.

What to do instead

Before answering any plan-evaluation item, state the normalization and prescription isodose in writing; then evaluate the target coverage against that line and report the hot spot as a percentage of the same reference.

Starting treatment delivery without confirming that the accessories in hand match the plan: bolus presence and thickness, electron cutout orientation and energy, wedge orientation, or block/tray seating.

Accessories are handled quickly by habit during changeovers, and candidates underestimate how often exam items hinge on the orientation or the count of a single accessory.

What to do instead

Answer delivery items by reciting a fixed pre-treatment checklist order: patient, immobilization, accessory and orientation, energy, field parameters, then imaging. Any option that skips an accessory check is wrong.

Treating setup-verification imaging as confirmatory only, applying a shift or proceeding after an out-of-tolerance match without stating the action level, repeat imaging, or physician notification.

Candidates conflate the physics of imaging with the workflow of deciding; they pick "take another image" or "shift and treat" without tying the decision to a defined tolerance and escalation path.

What to do instead

Learn the decision tree for each imaging modality used in your program: within tolerance, treat; outside tolerance, re-image or reposition; beyond the action level, stop and notify the radiation oncologist and document. Answer by naming the threshold and the escalation step.

Mixing up quality assurance frequencies and tolerances, for example assigning the monthly output constancy tolerance to a daily check, or placing mechanical/isocenter checks at the wrong interval.

The tolerance tables are memorized as a blur of percentages, and candidates answer from the number that feels most familiar rather than from the daily/monthly/annual grouping.

What to do instead

Build a three-column table (daily, monthly, annual) with the tolerance beside each test and rehearse it verbally; remember the pattern that tolerances tighten as the interval lengthens, with output constancy near 3 percent daily, 2 percent monthly, and 1 percent annual.

Computing monitor units in a single pass without converting cGy to Gy, applying the inverse-square correction for a non-calibration SSD, or dividing by the correct output, decay, tray, and wedge factors as a labeled chain.

MU equations reward speed, so candidates multiply the factors they remember and skip the unit conversion or one modifier; the arithmetic is then off by a clean factor of 100 or by the inverse-square term.

What to do instead

Write the MU equation as a full chain with each factor named and unit-tagged, do a rough order-of-magnitude estimate first, and sanity-check the result (a typical fraction should land in the low hundreds of MU, not single digits or thousands).

Exam requirements can change. Confirm current details with the exam provider.

ARRT Radiation Therapy practice

200 questions. Each one lists the choices, the correct answer, and an explanation. With JavaScript, this list opens one question at a time. The checker at the top of this page saves progress in this browser when it is available.

  1. Question 1Patient Care and Education

    Which two identifiers are acceptable for confirming a patient's identity before treatment?

    1. Full name and date of birth Correct answer.
    2. Room number and treatment time
    3. Diagnosis and prescribed dose
    4. Attending physician and machine number

    Explanation

    Two patient-specific identifiers must be matched against the treatment record before any procedure. Name combined with date of birth is a standard, unique pairing. Room numbers, machine assignments, and diagnoses are not identifiers.

  2. Question 2Patient Care and Education

    Who is responsible for obtaining informed consent for radiation therapy?

    1. The clinic nurse
    2. The dosimetrist
    3. The staff therapist
    4. The radiation oncologist Correct answer.

    Explanation

    Obtaining informed consent is a physician responsibility. The radiation oncologist explains the diagnosis, goals, risks, benefits, and alternatives, and documents the patient's agreement. Other team members may verify that consent is in the record but cannot obtain it.

  3. Question 3Patient Care and Education

    A patient receiving external beam therapy asks how to care for the treatment area. Which instruction is appropriate?

    1. Cover the area with an occlusive dressing
    2. Scrub the area with an antiseptic
    3. Wash gently with mild soap and water Correct answer.
    4. Apply a heating pad nightly

    Explanation

    Care of irradiated skin emphasizes gentle cleansing with mild soap and lukewarm water, patting dry, and avoiding friction, heat, and irritating products unless specifically prescribed. Abrasive cleansing, heat, and tightly occlusive dressings can worsen skin reactions.

  4. Question 4Patient Care and Education

    Which instruction should a therapist give about the skin markings placed for treatment?

    1. Cover them with makeup before arriving
    2. Re-draw them at home if they fade
    3. Leave them intact and keep them dry Correct answer.
    4. Scrub them off before each treatment

    Explanation

    Setup marks and tattoos ensure reproducible positioning for every fraction. Patients should protect them from rubbing, cosmetics, and sun, and should let staff re-apply any that fade. Therapists, not patients, replace faded markings.

  5. Question 5Patient Care and Education

    Which question best encourages a patient to describe concerns before simulation?

    1. Do you want a pill for anxiety?
    2. Are you nervous about today?
    3. You are not anxious, are you?
    4. What worries you most? Correct answer.

    Explanation

    Open-ended questions invite patients to express concerns in their own words and often reveal more than a yes-or-no answer. Leading or closed questions can suppress discussion or bias the response.

  6. Question 6Patient Care and Education

    A patient reports fatigue midway through a course of radiation therapy. Which advice is most appropriate?

    1. Balance rest with light activity Correct answer.
    2. Stop all physical activity until treatment ends
    3. Increase caffeine intake throughout the day
    4. Skip treatments until energy returns

    Explanation

    Fatigue is the most common side effect of radiation therapy and is managed with planned rest balanced against light exercise such as walking. Unnecessary bed rest and missed treatments worsen deconditioning and compromise the plan.

  7. Question 7Patient Care and Education

    Which dietary guidance is appropriate for a patient losing weight during treatment?

    1. Eat three large meals at set times each day
    2. Restrict protein to reduce nausea
    3. Eat small, frequent high-protein meals Correct answer.
    4. Replace all meals with liquid supplements

    Explanation

    Weight loss during therapy is addressed with small, frequent meals that are dense in calories and protein, along with a dietitian referral. Large meals are often poorly tolerated, and protein restriction worsens tissue wasting.

  8. Question 8Patient Care and Education

    A therapist recognizes a patient in the hospital cafeteria and a coworker asks about that patient's diagnosis. What is the appropriate response?

    1. Discuss it only if the patient is absent
    2. Decline to discuss the patient's information Correct answer.
    3. Confirm the diagnosis quietly
    4. Share details with staff who ask

    Explanation

    Protected health information may be shared only with those involved in the patient's care and only when needed. Casual discussion in public areas, even with coworkers, is a privacy breach and should be declined.

  9. Question 9Patient Care and Education

    Which precaution should be taught to a patient with treatment-related neutropenia?

    1. Delay reporting fever until the next visit
    2. Eat fresh raw vegetables daily
    3. Avoid crowds and report fever promptly Correct answer.
    4. Share food and utensils with family

    Explanation

    Neutropenic patients have reduced infection defenses and should avoid crowds and other sources of pathogens. Fever at or above about 100.4 degrees F (38 degrees C) must be reported immediately because infection can progress rapidly.

  10. Question 10Patient Care and Education

    Which dietary change is recommended for a patient with radiation-induced diarrhea?

    1. Choose low-fiber foods and clear fluids Correct answer.
    2. Drink milk with every meal
    3. Increase intake of bran and raw fruits daily
    4. Eat fried foods to slow transit

    Explanation

    Radiation-induced diarrhea is managed with a low-fiber, low-fat diet, generous fluid replacement, and limiting lactose or caffeine if they aggravate symptoms. Bulky and high-fat foods increase stool volume and symptoms.

  11. Question 11Patient Care and Education

    Which measure helps a patient with radiation-induced oral mucositis?

    1. Rinse with a commercial alcohol mouthwash
    2. Use saline rinses and avoid acidic foods Correct answer.
    3. Eat spicy foods to stimulate saliva
    4. Brush with a firm-bristled toothbrush

    Explanation

    Oral mucositis care includes gentle hygiene with a soft brush, saline or bicarbonate rinses, and bland, nonacidic foods. Alcohol-containing rinses, spicy foods, and abrasive brushing increase pain and mucosal injury.

  12. Question 12Patient Care and Education

    A patient begins to panic while positioned for treatment. What is the best initial action?

    1. Tell the patient to calm down
    2. Continue and finish the treatment quickly
    3. Cancel all remaining treatments
    4. Pause and coach slow breathing Correct answer.

    Explanation

    When anxiety escalates, treatment is paused and the patient is reassured using simple coping strategies such as slow, coached breathing. Dismissing the fear or rushing worsens panic and compromises immobilization.

  13. Question 13Patient Care and Education

    Which approach best prepares a young child for daily radiation therapy?

    1. Discourage parents from staying in the room
    2. Use simple words and allow a comfort item Correct answer.
    3. Promise the treatment will not hurt at all
    4. Withhold all information until the machine is on

    Explanation

    Children cope best with brief, honest explanations in simple language, preparation before entering the room, and a familiar comfort object. False reassurance and separation from caregivers increase fear and reduce cooperation.

  14. Question 14Patient Care and Education

    Which consideration is most important when positioning an older adult who has arthritis and hearing loss?

    1. Speak loudly and avoid written instructions
    2. Allow extra time and speak face-to-face Correct answer.
    3. Use the same immobilization as a younger adult
    4. Skip the skin assessment to save time

    Explanation

    Older adults frequently have sensory and mobility limitations, so the therapist should face the patient when speaking, speak clearly, and allow extra time for safe positioning. Immobilization may need adaptation to accommodate stiffness and pain.

  15. Question 15Patient Care and Education

    A 28-year-old patient scheduled for pelvic irradiation mentions that her period is late. What should the therapist do first?

    1. Order a urine pregnancy test independently
    2. Proceed with treatment as prescribed
    3. Notify the radiation oncologist before treatment Correct answer.
    4. Tell her pregnancy is not a concern

    Explanation

    Any patient of childbearing age should be asked about possible pregnancy, and a possible pregnancy must be reported to the radiation oncologist before treatment continues. The physician determines testing and any change in the plan.

  16. Question 16Patient Care and Education

    Which method best confirms that a patient understood instructions about skin care?

    1. Giving the patient a pamphlet at discharge
    2. Repeating the instructions several times
    3. Asking the patient to sign a handout
    4. Asking the patient to explain the steps back Correct answer.

    Explanation

    Teach-back, in which the patient restates the instructions in their own words, documents comprehension and reveals gaps. Providing materials or repeating information does not confirm that learning occurred.

  17. Question 17Patient Care and Education

    Before leaving the room during treatment, what should the therapist tell a patient who is in an immobilization device?

    1. Hold your breath for the entire treatment
    2. Remove the mask if you feel uncomfortable
    3. You can speak to me anytime through the intercom Correct answer.
    4. Do not move and there is no way to reach me

    Explanation

    Patients must be able to reach staff at all times during delivery, and the intercom and camera provide that link. Leaving a patient with no means of signaling distress is unsafe and increases anxiety and motion.

  18. Question 18Patient Care and Education

    During a weekly assessment the therapist observes moist desquamation in the treatment field. What is the appropriate action?

    1. Cover the area with an adhesive dressing
    2. Report the finding to the radiation oncologist Correct answer.
    3. Scrub the area to remove the exudate
    4. Apply a drying powder and continue treatment

    Explanation

    Moist desquamation represents epidermal breakdown and must be reported so the radiation oncologist can prescribe management and decide whether treatment needs modification. Therapists assess and document but do not independently choose topical products.

  19. Question 19Patient Care and Education

    A patient rates pain as 7 out of 10 before treatment. What is the therapist's most appropriate action?

    1. Delay treatment until the pain resolves
    2. Report the pain to the managing team Correct answer.
    3. Advise the patient to take extra medication
    4. Document the score and continue without comment

    Explanation

    Uncontrolled pain is reported to the managing team so analgesia can be adjusted; the therapist documents the assessment but does not prescribe or alter medications. Poorly controlled pain prevents the patient from holding position comfortably.

  20. Question 20Patient Care and Education

    A patient who speaks limited English arrives for daily treatment. How should communication be handled?

    1. Speak only to the accompanying family member
    2. Arrange a qualified medical interpreter Correct answer.
    3. Ask a bilingual housekeeper to translate
    4. Use the patient's young child as interpreter

    Explanation

    Qualified medical interpreters preserve accuracy and confidentiality during education and consent discussions. Untrained ad hoc interpreters introduce errors and may breach privacy or distort clinical information.

  21. Question 21Patient Care and Education

    A patient scheduled for palliative radiation is confused and cannot understand the consent discussion. Who may provide consent?

    1. The therapist assigned to the case
    2. The legally authorized health care agent Correct answer.
    3. The nursing supervisor on duty
    4. Any adult family member who is present

    Explanation

    When a patient lacks decision-making capacity, consent comes from a legally authorized surrogate such as a health care agent, proxy, or guardian. Staff members and relatives without legal authority cannot consent.

  22. Question 22Patient Care and Education

    A patient with an implanted cardioverter-defibrillator is scheduled for thoracic irradiation. What should the care team do?

    1. Assume the device is safe because the dose is low
    2. Coordinate with cardiology and physics Correct answer.
    3. Deactivate the device without consulting anyone
    4. Proceed and check the device after each fraction

    Explanation

    Radiation can damage implanted cardiac device circuitry, so the plan is reviewed with cardiology and medical physics for dose limits, shielding, and monitoring. Devices are never deactivated or repositioned without a coordinated plan.

  23. Question 23Patient Care and Education

    Which discussion should take place before pelvic irradiation begins in a 25-year-old male patient?

    1. Delay of fertility counseling until treatment ends
    2. Assurance that his fertility will not be affected
    3. Sperm banking options before treatment begins Correct answer.
    4. Fertility preservation options after treatment ends

    Explanation

    Fertility counseling and referral for sperm banking must occur before the first fraction, because pelvic irradiation can cause permanent sterility. Counseling after treatment is completed is too late to preserve fertility.

  24. Question 24Patient Care and Education

    Which practice verifies the correct treatment site immediately before delivery?

    1. Relying on the patient's memory of the prescription
    2. Checking the appointment schedule on the monitor
    3. Performing a time-out with the prescription Correct answer.
    4. Reviewing the plan during the previous chart round

    Explanation

    A formal time-out immediately before delivery confirms patient identity, site, laterality, and prescription against the approved plan. Memory, schedules, and prior reviews are not acceptable substitutes for the real-time check.

  25. Question 25Patient Care and Education

    A patient is discharged after permanent prostate brachytherapy. Which instruction should be given?

    1. Avoid all contact with adults for six months
    2. Return all clothing for radiation screening weekly
    3. Limit close contact with young children for a time Correct answer.
    4. Share a bed with an infant without restriction

    Explanation

    After permanent seed implantation, patients receive written precautions to limit prolonged close contact with pregnant women and young children for a defined period. Normal contact with other adults is permitted.

  26. Question 26Patient Care and Education

    A patient receiving radiation therapy to the head and neck reports persistent dry mouth. Which instruction is most appropriate?

    1. Drink several cups of coffee or cola each day to stimulate saliva.
    2. Rinse with an alcohol-based mouthwash several times a day.
    3. Sip water often and use sugar-free gum or candy. Correct answer.
    4. Limit fluid intake to reduce swelling of the salivary glands.

    Explanation

    Irradiation of the salivary glands reduces saliva flow, so moisture must be replaced frequently and salivary flow stimulated without adding sugar that promotes caries. Small sips of water and sugar-free sialogogues accomplish both goals. Alcohol-containing rinses are drying and irritating to irradiated mucosa.

  27. Question 27Patient Care and Education

    A patient's platelet count has fallen to 45,000/mm3 during a course of radiation therapy. Which instruction should the therapist reinforce?

    1. Use an electric razor and a soft-bristle toothbrush. Correct answer.
    2. Floss vigorously after every meal and snack.
    3. Use a hard-bristle toothbrush to clean the teeth thoroughly.
    4. Take aspirin daily to reduce the risk of clotting.

    Explanation

    Thrombocytopenia increases the risk of bleeding, so trauma to skin and mucosa should be minimized by using soft-bristle brushes and electric razors. Aspirin and other antiplatelet agents further impair clotting and are avoided unless specifically ordered. Any bleeding precautions are taught before invasive or abrasive habits continue.

  28. Question 28Patient Care and Education

    Which statement should the therapist include when teaching a patient about hair loss expected during cranial irradiation?

    1. Hair loss generally begins 2 to 3 weeks in and regrows after treatment. Correct answer.
    2. Wearing a snug wig cap during treatment will prevent any additional hair loss.
    3. Hair loss always begins within 24 hours after the first treatment fraction is given.
    4. Hair regrowth is unlikely to occur even after the entire course is finished.

    Explanation

    Epilation from irradiation occurs only in the treated field and typically begins about two to three weeks into the course. Regrowth usually starts weeks to months after treatment ends, although it may be incomplete after high doses. Hair loss is not preventable by covering the scalp, and it does not begin within a day of the first fraction.

  29. Question 29Patient Care and Education

    A patient receiving abdominal irradiation has a standing order for an oral antiemetic. Which instruction best supports control of nausea?

    1. Skip the medication on the days when you feel completely well.
    2. Take it on a schedule, including before each treatment. Correct answer.
    3. Take the medication only with the largest meal of the day.
    4. Take the medication only after vomiting has already started.

    Explanation

    Antiemetics work best when given prophylactically on a regular schedule so that blood levels are adequate before the emetogenic stimulus occurs. Waiting for vomiting allows nausea to become established and harder to control. Doses should not be skipped on good days, because symptoms are then more likely to break through.

  30. Question 30Patient Care and Education

    Before bringing a patient into the treatment room, the therapist confirms identity. Which practice meets the accepted standard?

    1. Confirm the patient's identity by matching the room number to the daily schedule.
    2. Check the name written on the door of the patient's changing cubicle.
    3. Verify identity by recognizing the patient from previous treatment visits.
    4. Ask the patient to state name and birth date, then compare with the record. Correct answer.

    Explanation

    Two identifiers must be obtained from the patient or an authorized representative and compared with the treatment record before any procedure. Room numbers, cubicle labels, and staff recognition are not reliable identifiers and can lead to treatment of the wrong site or person.

  31. Question 31Patient Care and Education

    During setup, a patient asks the therapist whether the treatment is meant to cure the cancer. Which response is most appropriate?

    1. Tell the patient that this topic cannot be discussed in the treatment room.
    2. Give your own understanding of the treatment intent from the chart.
    3. Acknowledge the question and refer the patient to the radiation oncologist. Correct answer.
    4. Suggest that the patient search the internet for statistics on the diagnosis.

    Explanation

    Discussion of prognosis and treatment intent falls within the radiation oncologist's scope of practice; the therapist acknowledges the concern and facilitates that conversation. Personal interpretation of the chart or internet statistics may be inaccurate and undermines the informed relationship with the physician. The question should never be dismissed as inappropriate.

  32. Question 32Patient Care and Education

    A patient mentions taking several herbal supplements and asks whether they matter for treatment. What is the appropriate response?

    1. Stop taking all supplements immediately without telling anyone.
    2. Report every supplement to the care team so the regimen can be reviewed. Correct answer.
    3. Herbal products are natural and harmless, so they do not need to be reported.
    4. Supplements matter only if a physician prescribed them.

    Explanation

    Herbal products can interact with medications, cause photosensitivity, or affect skin and mucosal reactions, so the full regimen must be disclosed and reviewed by the care team. Patients should not start or stop products unilaterally. Nonprescription status does not mean a product is biologically inactive.

  33. Question 33Patient Care and Education

    A patient receiving prostate irradiation is told to arrive with a full bladder. What is the main reason for this instruction?

    1. A full bladder shortens the time needed for the daily setup.
    2. A full bladder reduces the total number of treatment fractions that are required.
    3. It moves bowel out of the high-dose region and steadies the prostate. Correct answer.
    4. A full bladder prevents urinary incontinence during the treatment.

    Explanation

    A consistently filled bladder displaces small bowel away from the high-dose volume and reduces prostate motion, improving both normal-tissue sparing and daily reproducibility. The volume must be similar each day for the setup to be reliable. Bladder filling does not change the prescribed number of fractions.

  34. Question 34Patient Care and Education

    A patient taking opioid analgesics during pelvic irradiation reports hard stools every third day. Which instruction should the therapist reinforce?

    1. Restrict fluids so that the stool becomes less watery.
    2. Increase fluids and fiber and stay as active as tolerated. Correct answer.
    3. Take a daily iron supplement to help regulate bowel movements.
    4. Stop the opioid medication on your own without telling the care team.

    Explanation

    Opioids slow intestinal peristalsis, so the first-line measures are adequate fluid intake, dietary fiber, and mobility, with laxatives added as ordered. Analgesic changes must be made by the prescribing clinician because uncontrolled pain also impairs treatment. Iron supplementation is itself constipating.

  35. Question 35Patient Care and Education

    A patient whose religious beliefs require modesty asks to be treated only by a female therapist. How should the team respond?

    1. Refer the patient to another facility that shares the patient's beliefs.
    2. Explain that staffing assignments cannot be changed for personal preferences.
    3. Accommodate the request when feasible and document it in the record. Correct answer.
    4. Ask the patient to sign a waiver before treatment can continue.

    Explanation

    Culturally congruent care means honoring modesty and religious needs whenever staffing allows, then documenting the preference so it is consistently respected. Dismissing or transferring the patient creates an avoidable barrier to completing therapy. A waiver has no role because no safety exception exists.

  36. Question 36Patient Care and Education

    Which instruction should a patient receiving radiation therapy to the jaw receive to help prevent limitation of mouth opening?

    1. Use a hard-bristle toothbrush to massage the inside of the cheek.
    2. Limit jaw movement until the treatment course is finished.
    3. Do daily jaw-stretching exercises through the full range of motion. Correct answer.
    4. Keep the mouth closed and avoid chewing between treatments.

    Explanation

    Irradiation of the muscles of mastication can produce fibrosis and trismus, and prophylactic stretching through the full range of motion preserves opening. Immobility accelerates contracture, so rest and limitation of movement are counterproductive. Stretching is begun early and continued after treatment ends.

  37. Question 37Patient Care and Education

    A patient receiving head and neck irradiation says that meat tastes metallic and bitter. Which suggestion is most appropriate?

    1. Eat only very hot foods because heat masks the metallic taste.
    2. Use mild marinades, poultry, eggs, or dairy, and try cool foods. Correct answer.
    3. Avoid all protein foods until the treatment course has been completed.
    4. Add extra salt and hot spices to every meal.

    Explanation

    Taste alterations are common when the oral cavity is irradiated; bland marinades, alternative protein sources, and cool or room-temperature foods are usually better tolerated. Maintaining protein and calorie intake supports healing and weight maintenance. Very hot, salty, or spicy foods irritate the mucosa, and protein restriction worsens nutritional status.

  38. Question 38Patient Care and Education

    A patient with a valid do-not-resuscitate order arrives for a palliative treatment and becomes unresponsive in the waiting area. What is the appropriate action?

    1. Begin full resuscitation because a DNR order does not apply outside an inpatient unit.
    2. Follow the facility's DNR policy and activate the emergency response system. Correct answer.
    3. Wait for the family to arrive before beginning any intervention.
    4. Cancel the DNR order because the patient is now in a hospital department.

    Explanation

    A valid DNR order follows the patient across settings, including outpatient and treatment areas, and the team responds according to facility policy while summoning help. Therapists do not unilaterally rescind or override the order. Delay in activating the response system is never appropriate.

  39. Question 39Patient Care and Education

    A patient scheduled for the first treatment says, "I signed the consent, but I don't really know what a boost is." What is the therapist's best action?

    1. Explain the boost in detail and answer all of the patient's technical questions.
    2. Pause and arrange for the radiation oncologist to answer the questions. Correct answer.
    3. Proceed with the treatment because the consent form has already been signed.
    4. Ask the patient to sign a second consent form before continuing.

    Explanation

    Valid informed consent requires that the patient understand the proposed treatment, and the physician is responsible for providing that explanation. The therapist documents the patient's unanswered questions and facilitates physician follow-up rather than supplying a medical explanation. A signature alone does not establish understanding.

  40. Question 40Patient Care and Education

    A patient's adult child asks to stand inside the treatment room and hold the patient's hand during delivery. What is the best response?

    1. Explain that no one may stay in the room during beam-on and offer comfort measures. Correct answer.
    2. Allow the family member to remain if the dose rate is reduced.
    3. Permit the visit only if the patient signs a release of liability form.
    4. Allow the family member to stay if lead shielding is placed over them.

    Explanation

    Only the patient may occupy the treatment room while the beam is on, because any other person would receive unnecessary exposure that no practical shielding or dose reduction can justify. The therapist acknowledges the family member's wish to help and offers supportive measures before and after delivery. Facility policy governs any rare exception.

  41. Question 41Safety

    The ALARA principle requires that occupational and patient exposures be:

    1. reduced for staff members but not for patients undergoing treatment
    2. set only by the maximum limits written in federal regulations
    3. kept as low as reasonably achievable while still meeting the clinical objective Correct answer.
    4. eliminated completely no matter what effect this has on patient care

    Explanation

    ALARA is a optimization principle: dose is reduced to the lowest level that still accomplishes the required clinical task, taking economic and social factors into account. It applies in addition to, not instead of, regulatory dose limits.

  42. Question 42Safety

    The annual occupational effective dose limit for a radiation worker is:

    1. 150 mSv
    2. 500 mSv
    3. 50 mSv Correct answer.
    4. 5 mSv

    Explanation

    National radiation protection guidance sets the annual occupational effective dose limit at 50 mSv (5 rem) per year, with the cumulative lifetime dose constrained by the age-based formula.

  43. Question 43Safety

    The annual effective dose limit for an individual member of the general public exposed to radiation from a licensed facility is:

    1. 1 mSv per year Correct answer.
    2. 0.1 mSv per year
    3. 50 mSv per year
    4. 0.5 mSv per year

    Explanation

    The dose limit for the general public is 1 mSv (100 mrem) per year, one-tenth or less of the occupational limit, because the public includes children and others who are not monitored or trained.

  44. Question 44Safety

    A therapist who routinely handles radioactive sources should wear an extremity dosimeter:

    1. on the trunk beneath the lead apron
    2. on the finger expected to receive the highest dose, beneath the glove Correct answer.
    3. clipped to the collar outside the lead apron
    4. on the wrist of the dominant hand, over the glove

    Explanation

    Ring or extremity badges are worn on the finger most likely to receive the highest dose and are placed under the glove so that the measured dose reflects what the skin actually receives.

  45. Question 45Safety

    Which set of principles forms the basis of external radiation protection?

    1. Time, distance, and shielding Correct answer.
    2. Collimation, filtration, and kVp selection
    3. Ventilation, temperature, and humidity control
    4. Containment, dilution, and decay

    Explanation

    External exposure is controlled by minimizing time near the source, maximizing distance from it, and placing appropriate shielding between the source and the person. The inverse square law makes distance especially powerful.

  46. Question 46Safety

    The function of the treatment room door interlock is to:

    1. terminate irradiation if the door is opened during treatment Correct answer.
    2. permit staff to enter briefly while the beam remains on
    3. alert the patient that the door has been opened
    4. record each entry into the treatment room

    Explanation

    The interlock is a safety circuit that interrupts beam-on conditions when the door is opened, preventing anyone from entering an active radiation field. It cannot be bypassed during routine treatment.

  47. Question 47Safety

    Before treatment delivery, patient identity should be confirmed using:

    1. the appointment time listed at the treatment console
    2. the patient's room number and diagnosis
    3. two independent identifiers such as full name and date of birth Correct answer.
    4. the photograph attached to the treatment record alone

    Explanation

    Safe practice requires at least two independent identifiers, verified by asking the patient directly and matching them to the treatment prescription. Room numbers and schedules change and are not unique to a person.

  48. Question 48Safety

    Protective aprons used in radiation therapy typically provide attenuation equivalent to:

    1. 2 mm lead equivalent
    2. 0.5 mm lead equivalent Correct answer.
    3. 1 mm lead equivalent
    4. 0.25 mm lead equivalent

    Explanation

    Standard protective aprons are rated at 0.5 mm lead equivalent, which attenuates most scattered diagnostic-quality photons while keeping the garment wearable. Thicker aprons are reserved for special procedures.

  49. Question 49Safety

    A point source produces a dose rate of 40 mGy/h at 1 m. Ignoring attenuation, what is the dose rate at 2 m?

    1. 20 mGy/h
    2. 80 mGy/h
    3. 160 mGy/h
    4. 10 mGy/h Correct answer.

    Explanation

    Dose rate from a point source falls off with the square of distance: doubling the distance divides the rate by four. Here 40 mGy/h divided by 4 equals 10 mGy/h.

  50. Question 50Safety

    After passing through two half-value layers, the intensity of a beam is reduced to:

    1. one eighth of the original
    2. one half of the original
    3. one quarter of the original Correct answer.
    4. zero

    Explanation

    Each half-value layer halves the intensity, so two layers transmit 1/2 × 1/2 = 1/4 of the original beam. Attenuation is exponential and never reaches zero.

  51. Question 51Safety

    A primary radiation barrier must be able to attenuate:

    1. the primary beam in all directions in which it can be pointed Correct answer.
    2. neutrons produced by photonuclear reactions
    3. leakage radiation from the accelerator housing only
    4. scattered radiation from the patient only

    Explanation

    A primary barrier is one that the unattenuated useful beam can strike directly, so it must be thick enough to reduce the primary beam to the required level for all achievable beam orientations. Secondary barriers handle only scatter and leakage.

  52. Question 52Safety

    After a radiation worker declares her pregnancy in writing, the equivalent dose to the embryo or fetus should not exceed:

    1. 0.5 mSv per month, not to exceed 5 mSv total Correct answer.
    2. 5 mSv per month with no total limit
    3. 1 mSv per month, not to exceed 10 mSv total
    4. 50 mSv per month, not to exceed 500 mSv total

    Explanation

    Once pregnancy is declared, the recommended limit is 0.5 mSv (50 mrem) in any month and 5 mSv (500 mrem) over the entire gestation period. The declaration must be voluntary and in writing.

  53. Question 53Safety

    Which survey instrument is most appropriate for detecting removable radioactive contamination on a surface?

    1. An optically stimulated luminescence badge
    2. A thermoluminescent dosimeter
    3. A thimble ionization chamber
    4. A Geiger-Mueller survey meter Correct answer.

    Explanation

    A Geiger-Mueller detector is highly sensitive to small amounts of beta and gamma activity and gives an audible response, making it well suited for locating contamination. It is used for surveying rather than for measuring absorbed dose accurately.

  54. Question 54Safety

    The occupancy factor (T) used in barrier calculations accounts for:

    1. the fraction of time that the area beyond a barrier is occupied Correct answer.
    2. the fraction of operating time that the beam is pointed at a given barrier
    3. the number of half-value layers in the barrier
    4. the total dose delivered by the unit each week at 1 m

    Explanation

    The occupancy factor adjusts the required barrier thickness for how much time people actually spend in the area beyond it; a fully occupied office next to a wall justifies more shielding than a transient corridor.

  55. Question 55Safety

    In shielding design, the workload (W) of a linear accelerator is expressed as:

    1. the number of patients treated on the unit each day
    2. the dose delivered at 1 m from the unit per week Correct answer.
    3. the maximum photon energy available on the unit
    4. the fraction of time the beam is directed at each barrier

    Explanation

    Workload quantifies weekly use in terms of absorbed dose at 1 m, usually in Gy per week, and is a required input for calculating barrier thickness. It reflects how much the machine is used rather than how many patients are seen.

  56. Question 56Safety

    If radioactive material contacts a patient's skin, the first step is to:

    1. delay washing until a survey meter is available to monitor progress
    2. wash gently with lukewarm water and mild soap Correct answer.
    3. cover the area with an occlusive dressing and recheck in 24 hours
    4. scrub the area firmly with a stiff brush until the meter reading falls

    Explanation

    Decontamination begins promptly with gentle washing using lukewarm water and mild soap; friction and hot water can abrade skin and increase absorption. Vigorous scrubbing risks breaching the skin barrier, so repeated gentle cycles are preferred.

  57. Question 57Safety

    After an HDR brachytherapy source has been retracted into the shielded safe, the therapist should next:

    1. send the patient to the waiting area and survey the room later
    2. remove the applicator without performing a survey
    3. release the patient immediately to shorten staff exposure
    4. survey the patient and the treatment room before the patient leaves Correct answer.

    Explanation

    A radiation survey of the patient and room confirms that the source has fully returned to the safe and that no activity remains in or near the patient. Releasing the patient without this verification risks an undetected retained or dislodged source.

  58. Question 58Safety

    Tissue receives an absorbed dose of 0.1 Gy from alpha particles, which have a radiation weighting factor of 20. The equivalent dose is:

    1. 2 Sv Correct answer.
    2. 20 Sv
    3. 0.1 Sv
    4. 0.005 Sv

    Explanation

    Equivalent dose equals absorbed dose multiplied by the radiation weighting factor: 0.1 Gy × 20 = 2 Sv. Alpha particles are densely ionizing, so each gray of absorbed dose carries far more biologic risk than a gray of gamma radiation.

  59. Question 59Safety

    For a worker who wears a lead apron during fluoroscopic or portable procedures, the personal dosimeter should generally be worn:

    1. at the collar outside the apron only
    2. outside the apron at waist level
    3. on the wrist of the hand that operates the console
    4. under the apron at waist level, with a collar dosimeter if facility policy requires it Correct answer.

    Explanation

    The body badge is worn beneath the apron at waist level to estimate the dose received by shielded tissue, and many facilities add a collar badge outside the apron to estimate unshielded head and neck dose. Facility policy determines the final monitoring arrangement.

  60. Question 60Safety

    During setup, a patient reports itching and swelling after contact with latex gloves. The therapist should:

    1. test the skin with a latex tourniquet before proceeding
    2. continue with latex gloves but double-glove
    3. reassure the patient that the reaction is unlikely to be allergic
    4. switch to latex-free supplies and notify the care team Correct answer.

    Explanation

    A reported latex reaction is managed by removing latex from the patient's environment and documenting the allergy so all staff avoid latex gloves, catheters, and tourniquets. Substituting latex-free products prevents progression to a severe reaction.

  61. Question 61Safety

    For a medical linear accelerator, leakage radiation in the useful beam at 1 m from the path of the electron beam must not exceed:

    1. 2% of the useful beam dose
    2. 10% of the useful beam dose
    3. 0.1% of the useful beam dose Correct answer.
    4. 0.001% of the useful beam dose

    Explanation

    Accelerator standards limit leakage radiation to 0.1% of the useful beam dose at 1 m from the electron beam path, with additional limits outside the treatment field. This keeps head leakage a minor contributor compared with the primary beam.

  62. Question 62Safety

    During an HDR treatment the source fails to return to the safe. The therapist's immediate action is to:

    1. wait outside the room for the physicist to arrive
    2. reset the console and restart the fraction
    3. activate the emergency retract, then evacuate the patient if it fails Correct answer.
    4. enter the room and retrieve the source by hand

    Explanation

    Staff first attempt the emergency retract from outside the room; if the source still cannot be recovered, the patient is removed using the emergency release and the room is secured while the radiation safety officer is notified. Manual handling of an HDR source is never an acceptable first response.

  63. Question 63Safety

    A sealed brachytherapy source is discovered missing after a dressing change. The therapist should first:

    1. search the trash containers by hand to recover the source
    2. complete the day's remaining schedule and document the event later
    3. send the patient home and file a report the next morning
    4. secure the area, notify the radiation safety officer, and perform a radiation survey Correct answer.

    Explanation

    A lost source is an emergency: the area is secured to prevent inadvertent exposure, the radiation safety officer and regulator are notified per protocol, and a survey locates the source before any cleanup. Hand searching without a detector risks a significant localized exposure.

  64. Question 64Safety

    A barrier reduces the primary beam to 1/16 of its original intensity. How many half-value layers does this represent?

    1. 4 Correct answer.
    2. 8
    3. 16
    4. 2

    Explanation

    Transmission equals (1/2)^n, where n is the number of half-value layers. Since 1/16 equals (1/2)^4, the barrier is four half-value layers thick.

  65. Question 65Safety

    The annual occupational equivalent dose limit for the hands and forearms is:

    1. 150 mSv
    2. 5000 mSv
    3. 500 mSv Correct answer.
    4. 50 mSv

    Explanation

    Extremities are limited to 500 mSv (50 rem) per year because localized skin and tissue effects, rather than whole-body stochastic risk, drive the limit. This is ten times the whole-body effective dose limit.

  66. Question 66Safety

    Which annual effective dose limit applies to a radiation therapy technologist who is not pregnant and is occupationally exposed?

    1. 500 mSv (50 rem)
    2. 150 mSv (15 rem)
    3. 50 mSv (5 rem) Correct answer.
    4. 5 mSv (0.5 rem)

    Explanation

    The occupational whole-body effective dose limit is 50 mSv (5 rem) per year. It applies to stochastic risk from total effective dose and is separate from the lens and extremity limits. The 5 mSv value is the public limit, 150 mSv is the lens limit, and 500 mSv is the extremity/skin limit.

  67. Question 67Safety

    The ALARA principle in radiation protection requires that occupational exposures be:

    1. eliminated completely for every radiation worker
    2. reduced only after a personnel dosimeter alarm sounds
    3. kept as low as reasonably achievable (ALARA) Correct answer.
    4. held at the legal dose limit whenever possible

    Explanation

    ALARA requires that exposures be kept as low as reasonably achievable, taking social and economic factors into account. It is a proactive principle, not a threshold that is triggered by a badge reading. Complete elimination of all exposure is not required.

  68. Question 68Safety

    The standard radiation warning symbol consists of a:

    1. red trefoil on a white background
    2. yellow trefoil on a magenta background
    3. magenta trefoil on a yellow background Correct answer.
    4. black trefoil on a yellow background

    Explanation

    The standard radiation warning sign is a magenta trefoil on a yellow background. The colors and trefoil shape are specified so the symbol is recognized internationally.

  69. Question 69Safety

    A ring dosimeter used for extremity monitoring should be worn:

    1. clipped to the collar outside the apron
    2. under the glove, detector facing the palm Correct answer.
    3. on the index finger over the glove
    4. on the wrist over the sleeve

    Explanation

    A ring badge is worn beneath the glove with the detector on the palm side so the dose to the hands is estimated accurately. Wearing it over the glove risks contamination and inaccurate readings.

  70. Question 70Safety

    In barrier calculations, the use factor (U) represents the:

    1. fraction of the workload directed at a specific barrier Correct answer.
    2. number of half-value layers required in the barrier
    3. ratio of scattered radiation to primary radiation at the barrier
    4. fraction of time the room is occupied by nonoccupationally exposed persons

    Explanation

    The use factor U is the fraction of the workload for which the primary beam is directed at a particular barrier. The occupancy factor T describes how long adjacent areas are occupied; the two are separate terms in barrier calculations.

  71. Question 71Safety

    Which material is most appropriate for shielding photoneutrons produced by a linear accelerator operating above 10 MV?

    1. Aluminum
    2. Plate glass
    3. Lead
    4. Borated polyethylene Correct answer.

    Explanation

    Above 10 MV, linacs produce photoneutrons, which are best shielded by hydrogenous materials such as borated polyethylene that thermalize neutrons and absorb them with boron. Lead and aluminum are effective for photons but poor neutron shields.

  72. Question 72Safety

    The purpose of a control badge stored in a low-background area is to:

    1. establish the background dose to subtract from personnel badges Correct answer.
    2. measure the dose rate at the treatment console during beam-on
    3. monitor the radiation level in the patient waiting area
    4. provide a spare badge when a worker loses one

    Explanation

    A control badge is stored in a low-background area and measures background and transit exposure. That value is subtracted from personnel badges so that only occupational dose is reported.

  73. Question 73Safety

    Under 10 CFR 35, a medical event includes a treatment in which the administered dose differs from the prescribed dose by at least:

    1. 20% Correct answer.
    2. 15%
    3. 5%
    4. 10%

    Explanation

    A medical event includes treatment to the wrong patient, site, or tissue, or a dose that differs from the prescribed dose by 20% or more. Lesser deviations may require review but do not meet the definition.

  74. Question 74Safety

    A patient with a permanent interstitial implant may be released without written precautions if the measured exposure rate at 1 meter is less than:

    1. 100 mrem/h (1 mSv/h) at 1 meter
    2. 5 mrem/h (0.05 mSv/h) at 1 meter Correct answer.
    3. 50 mrem/h (0.5 mSv/h) at 1 meter
    4. 2 mrem/h (0.02 mSv/h) at 1 meter

    Explanation

    NRC guidance allows release of a permanent implant patient without written precautions when the exposure rate at 1 meter is below 5 mrem/h (0.05 mSv/h). Above that level, written instructions are provided.

  75. Question 75Safety

    If a vial of liquid radiopharmaceutical is dropped and spills in the hot lab, the first action should be to:

    1. cover the spill with a lead sheet and resume work
    2. evacuate and restrict the area, then notify the radiation safety officer Correct answer.
    3. wipe up the spill with paper towels and place the towels in regular trash
    4. dilute the spill with water and flush it into the sink drain

    Explanation

    The first response to a radioactive spill is to limit spread: evacuate, restrict the area, and notify the radiation safety officer. Cleanup is performed only after the RSO directs it, using appropriate absorbent materials.

  76. Question 76Safety

    Which instrument is best suited for measuring the radiation dose rate outside a shielded door?

    1. Well counter
    2. Dose calibrator
    3. Geiger-Mueller counter
    4. Ionization chamber survey meter Correct answer.

    Explanation

    An ionization chamber survey meter is used to measure dose rate because it has a relatively flat energy response and reads in mR/h or µSv/h. GM counters are used primarily for contamination surveys and may saturate in high fields.

  77. Question 77Safety

    Unused sealed brachytherapy sources should be stored:

    1. in a locked, labeled shielded container with a removal log Correct answer.
    2. on an open shelf in the treatment room for rapid access
    3. in a refrigerator to slow radioactive decay
    4. in the patient's room for the duration of the implant

    Explanation

    Sealed sources must be kept in a locked, labeled shielded container, and each removal and return must be logged to maintain accountability and security. This satisfies NRC requirements for source control.

  78. Question 78Safety

    A barrier has a tenth-value layer of 10 cm for the radiation in question. If the unshielded dose rate at a point is 800 mSv/week, what barrier thickness will reduce it to 20 mSv/week?

    1. 40 cm
    2. 10 cm
    3. 16 cm Correct answer.
    4. 20 cm

    Explanation

    The required attenuation factor is 800/20 = 40. The number of tenth-value layers is log10(40) ≈ 1.6, so with a 10 cm TVL the barrier must be about 16 cm thick.

  79. Question 79Safety

    After discovery of a medical event, the licensee must notify the NRC by telephone no later than:

    1. 24 hours Correct answer.
    2. 5 calendar days
    3. 48 hours
    4. 15 calendar days

    Explanation

    10 CFR 35.3047 requires telephone notification to the NRC within 24 hours of discovering a medical event, followed by a written report within 15 days. The 15-day interval is for the written report, not the initial call.

  80. Question 80Safety

    A worker receives an absorbed dose of 2 mGy from gamma rays (wR = 1) and 0.3 mGy from neutrons (wR = 10). What is the total equivalent dose?

    1. 3.0 mSv
    2. 12.0 mSv
    3. 2.3 mSv
    4. 5.0 mSv Correct answer.

    Explanation

    Equivalent dose is the sum of absorbed dose multiplied by the radiation weighting factor for each radiation type: (2 × 1) + (0.3 × 10) = 5.0 mSv. Gamma rays have a weighting factor of 1, and neutrons have a weighting factor of 10 in this scenario.

  81. Question 81Treatment Planning

    A patient is simulated for head and neck radiotherapy. What is the primary purpose of a thermoplastic mask?

    1. To increase the surface dose through bolus effect
    2. To shield the spinal cord from primary radiation
    3. To limit motion and improve setup reproducibility Correct answer.
    4. To reduce the dose rate delivered by the linear accelerator

    Explanation

    Immobilization devices fix the patient's position and are indexed to the treatment couch so the planned geometry is reproduced at each fraction; thermoplastic masks conform to the head and neck for this purpose. They are not designed to shield tissue or to change machine output.

  82. Question 82Treatment Planning

    Why is CT the preferred imaging modality for treatment planning?

    1. It eliminates the need for patient immobilization
    2. It provides electron density data for dose calculation Correct answer.
    3. It delivers a therapeutic dose that contributes to the plan
    4. It provides real-time fluoroscopy during each treatment fraction

    Explanation

    CT numbers are calibrated against electron density, so CT data support heterogeneity-corrected dose calculation and three-dimensional anatomy in the treatment position. CT simulation uses diagnostic-level exposure and is not therapeutic.

  83. Question 83Treatment Planning

    According to ICRU definitions, which volume is created by adding a geometric margin to the clinical target volume to account for setup variation and organ motion?

    1. Gross tumor volume (GTV)
    2. Treated volume
    3. Clinical target volume (CTV)
    4. Planning target volume (PTV) Correct answer.

    Explanation

    The PTV is the CTV plus a geometric margin covering setup variation, internal motion, and deformation; beams, field shaping, and the prescription are defined around it. The GTV and CTV describe demonstrable and microscopic tumor extent.

  84. Question 84Treatment Planning

    A bolus is placed over a surgical scar on the chest wall. What effect does it have on the dose distribution?

    1. It reduces scatter dose to the opposite lung
    2. It increases the depth of the maximum dose
    3. It moves maximum dose nearer the skin surface Correct answer.
    4. It flattens the beam profile across the field

    Explanation

    Bolus is tissue-equivalent material placed on the skin that shifts the build-up region toward the surface so superficial tissues receive full dose. It does not flatten the beam profile or act as a shield.

  85. Question 85Treatment Planning

    A wedge filter is used in a treatment plan primarily to do which of the following?

    1. Increase the dose rate at the central axis
    2. Produce a dose gradient across the treatment field Correct answer.
    3. Eliminate the need for heterogeneity corrections
    4. Reduce penumbra at the field edges

    Explanation

    A wedge attenuates the beam differentially across the field, tilting the isodose curves so dose can be homogenized across a sloping surface or made to compensate where fields overlap. Wedges attenuate rather than intensify the beam.

  86. Question 86Treatment Planning

    Which statement describes an SAD (isocentric) treatment technique?

    1. The patient is repositioned between each field so SSD remains fixed
    2. Only one gantry angle is used for the entire course
    3. The source-to-skin distance is held constant while gantry angle changes
    4. The target sits at isocenter and SAD remains constant Correct answer.

    Explanation

    In SAD technique the patient is set so the target lies at machine isocenter, and the source-axis distance stays the same for every gantry angle. Field size at the patient's surface therefore varies with gantry angle while the field at isocenter stays fixed.

  87. Question 87Treatment Planning

    A plan is normalized so that 100% equals the prescribed dose. What does the 95% isodose line represent?

    1. Tissue receiving at least 95% of the prescribed dose Correct answer.
    2. Tissue receiving exactly 95% of the maximum dose in the patient
    3. The boundary outside which no radiation is delivered
    4. The maximum dose delivered anywhere in the patient

    Explanation

    Isodose curves connect points of equal dose and are labeled as a percentage of the normalization value; with prescription normalization, the 95% line bounds tissue receiving at least 95% of the prescribed dose. Tissue outside the line still receives dose, just at a lower level.

  88. Question 88Treatment Planning

    A dose-volume histogram (DVH) for a target volume provides which information?

    1. The dose rate delivered during each fraction
    2. The energy of the photon beam used
    3. The fraction of the volume receiving at least a given dose Correct answer.
    4. The spatial location of the cold spot within the volume

    Explanation

    A DVH plots volume against dose, showing how much of a structure receives at least (cumulative) or exactly (differential) a given dose. It contains no spatial information about where that dose is delivered.

  89. Question 89Treatment Planning

    The CTV-to-PTV margin accounts primarily for which of the following?

    1. Uncertainty in the dose calculation algorithm
    2. Setup uncertainty and internal organ motion Correct answer.
    3. The dosimetric penumbra of the beam only
    4. Microscopic tumor spread beyond the gross tumor

    Explanation

    The CTV already contains microscopic disease, so the added margin to the PTV is geometric, covering setup error, internal motion, and deformation. Penumbra and algorithm uncertainty are handled by other means.

  90. Question 90Treatment Planning

    A 6 MV photon beam passes through lung tissue. Compared with unit-density tissue of the same thickness, what is the typical effect?

    1. No change, because attenuation does not depend on density
    2. Greater transmission from lower density and added scatter Correct answer.
    3. Greater attenuation from the low atomic number of lung
    4. Less transmission because lung has higher electron density

    Explanation

    Lung has far lower electron density, so fewer photons interact and more reach distal tissue; loss of scatter equilibrium near the interface also alters the distribution. This is why heterogeneity-corrected algorithms are needed for thoracic plans.

  91. Question 91Treatment Planning

    Field-in-field (forward-planned) technique is used most often in breast radiotherapy to do which of the following?

    1. Reduce the number of fractions required
    2. Reduce hot spots and improve homogeneity Correct answer.
    3. Eliminate the need for a boost
    4. Increase dose to the lumpectomy cavity

    Explanation

    Field-in-field adds small MLC-shaped subfields to the open tangents to reduce regions of high dose, improving homogeneity without inverse planning. It does not change fractionation or deliver a boost.

  92. Question 92Treatment Planning

    A superficial skin lesion requires treatment limited to roughly the first 1.5 cm of tissue. Which approach is most appropriate?

    1. 18 MV photons through opposed lateral fields
    2. 20 MeV electrons with a 20 × 20 cm cone
    3. 6 MV photons with 1 cm bolus
    4. 6 MeV electrons with minimal bolus Correct answer.

    Explanation

    Electron energy determines the depth of the useful dose; 6 MeV treats approximately the first 1.5–2 cm with the maximum dose near the surface, matching a superficial lesion. Higher energies, whether photons or electrons, would treat unnecessarily deep tissue.

  93. Question 93Treatment Planning

    A beam's-eye-view (BEV) display is used during treatment planning to do which of the following?

    1. Shape the field and MLC aperture along the beam axis Correct answer.
    2. Determine the patient's setup error after treatment
    3. Measure the output of the linear accelerator
    4. Convert CT Hounsfield units into electron density

    Explanation

    Beam's-eye-view projects the patient's anatomy from the radiation source's perspective, allowing blocks or MLC leaves to be shaped to the target while avoiding organs at risk. CT-number conversion and output measurement are separate processes.

  94. Question 94Treatment Planning

    Which is the main purpose of a 4D CT scan in treatment planning for a lung tumor?

    1. To reduce the imaging dose delivered to the patient
    2. To improve tumor contrast within the lung
    3. To characterize respiratory tumor motion for margins or gating Correct answer.
    4. To eliminate the need for a PET scan

    Explanation

    4D CT sorts images by respiratory phase, letting the planner define an internal target volume or select a gating window that covers tumor motion. It does not improve contrast or reduce imaging dose.

  95. Question 95Treatment Planning

    According to ICRU 83, dose reporting for a target volume should include which parameter?

    1. Only the maximum point dose
    2. The total monitor units used per fraction
    3. D2% and D98% for the PTV Correct answer.
    4. The beam energy and source-to-skin distance

    Explanation

    ICRU 83 recommends reporting near-maximum (D2%) and near-minimum (D98%) doses, plus D50%, for target volumes so coverage and homogeneity can be judged. Machine settings are not part of the ICRU dose report.

  96. Question 96Treatment Planning

    The gamma index is used in patient-specific IMRT QA primarily to do which of the following?

    1. Compare measured and calculated dose with dose/distance criteria Correct answer.
    2. Determine the monitor units for each segment
    3. Calculate the dose to the spinal cord from a single beam
    4. Measure the output constancy of the linac

    Explanation

    Gamma analysis combines a dose-difference criterion with a distance-to-agreement criterion in a single index, and a typical passing criterion is at least 95% of points at 3%/3 mm. It is an evaluation tool, not a dose calculation.

  97. Question 97Treatment Planning

    A custom compensator is preferred over a wedge for a large, irregular sloping surface because it does which of the following?

    1. Removes the need for a CT scan
    2. Increases the surface dose by acting as bolus
    3. Eliminates penumbra at the beam edge
    4. Provides attenuation tailored to the patient's individual anatomy Correct answer.

    Explanation

    A compensator is milled so its thickness matches the tissue deficit along each ray, accounting for individual contour and internal density, whereas a wedge produces only a single linear gradient. Mounted in the accessory tray, it sits away from the skin and does not act as bolus.

  98. Question 98Treatment Planning

    A parotid gland dose constraint in a head and neck plan is most commonly specified as which of the following?

    1. V20 Gy less than 30%
    2. Mean dose of 26 Gy or less Correct answer.
    3. Minimum dose of 45 Gy
    4. Maximum point dose of 26 Gy

    Explanation

    Salivary function correlates with the dose received by the whole gland, so sparing is expressed as a mean dose of about 26 Gy or less to at least one parotid. Maximum point dose and V20 thresholds are not the standard parotid metrics.

  99. Question 99Treatment Planning

    A digitally reconstructed radiograph (DRR) is generated from the planning CT and is used mainly to do which of the following?

    1. Provide a reference image for verifying patient setup Correct answer.
    2. Replace the need for a CT calibration curve
    3. Calculate the dose distribution inside the patient
    4. Serve as the prescription document for the physician

    Explanation

    A DRR is computed from the planning CT at a chosen beam's-eye view to simulate the treatment radiograph, providing a reference for matching portal or kV images at treatment. It has no dose-calculation role.

  100. Question 100Treatment Planning

    The percentage depth dose of a photon beam increases when which of the following changes occurs?

    1. Field size shrinks from 20 × 20 cm to 5 × 5 cm
    2. Beam energy decreases from 18 MV to 6 MV
    3. SSD decreases from 100 cm to 80 cm
    4. Field size increases from 10 × 10 cm to 20 × 20 cm Correct answer.

    Explanation

    Larger fields increase scattered dose to depth, raising the percent depth dose for a given energy and SSD. Smaller fields, shorter SSD, and lower energy each decrease PDD.

  101. Question 101Treatment Planning

    A lung tumor plan is recalculated with a model-based algorithm (such as AAA or Acuros) instead of a simpler pencil-beam algorithm. What is the most likely finding?

    1. Monitor units decrease by about 50%
    2. Coverage decreases because lateral disequilibrium is modeled Correct answer.
    3. Distributions are identical since both use the same CT
    4. Coverage increases because tissue density is ignored

    Explanation

    Pencil-beam algorithms tend to overestimate dose in and beyond low-density lung because lateral electron transport is not fully modeled; model-based algorithms predict lower target coverage, sometimes requiring plan adjustment. Both use the same CT data, so the difference lies in transport modeling.

  102. Question 102Treatment Planning

    Which statement best distinguishes VMAT from step-and-shoot IMRT?

    1. VMAT cannot be planned with inverse optimization
    2. VMAT requires a fixed gantry angle for each segment
    3. Dose is delivered during continuous arc rotation with dynamic MLCs Correct answer.
    4. VMAT eliminates the need for image guidance

    Explanation

    VMAT delivers dose during continuous gantry rotation while MLC positions and dose rate vary, which shortens treatment time compared with step-and-shoot IMRT. Both techniques use inverse planning, and both still require image guidance.

  103. Question 103Treatment Planning

    For a lung SBRT plan, a high conformity index combined with a low gradient index indicates which of the following?

    1. The plan has a large hot spot outside the PTV
    2. The plan uses more monitor units than conventional fractionation
    3. The prescription isodose poorly matches the PTV with slow fall-off
    4. The prescription isodose matches the PTV and dose falls off rapidly Correct answer.

    Explanation

    The conformity index measures how well the prescription isodose covers the target, while the gradient index measures the steepness of dose fall-off outside it. High conformity with a low gradient index means tight target coverage with rapid fall-off.

  104. Question 104Treatment Planning

    A patient receives 45 Gy in 25 fractions to the pelvis followed by a 20 Gy boost in 10 fractions. Which approach is appropriate for evaluating the composite dose to the rectum?

    1. Sum the distributions as EQD2 and review the composite DVH Correct answer.
    2. Use only the boost plan DVH because it delivers more dose
    3. Add the peak dose from each plan regardless of fractionation
    4. Compare the two plans by total monitor units

    Explanation

    Composite evaluation requires spatial summation of the two distributions, ideally converted to an equivalent dose in 2-Gy fractions when fraction sizes differ, followed by review of the composite DVH. Neither peak doses nor monitor units represent composite organ dose.

  105. Question 105Treatment Planning

    A planning CT and an MRI are rigidly registered to define a prostate target. Which statement about this registration is correct?

    1. It is valid only if the patient is repositioned between scans
    2. Registration converts MRI signal into Hounsfield units
    3. It replaces CT because MRI provides electron density
    4. MRI contours are mapped onto the CT used for dose calculation Correct answer.

    Explanation

    Dose calculation requires CT electron density, so the MRI is registered to the planning CT and contours drawn on MRI are mapped onto the CT geometry. MRI signal intensity is not a reliable electron density surrogate.

  106. Question 106Treatment Planning

    In inverse treatment planning for IMRT, which input does the planner supply before the optimization algorithm runs?

    1. The final MLC leaf positions and segment shapes for each beam
    2. The monitor units assigned to each field of the finished plan
    3. Dose objectives and constraints for target and organs at risk Correct answer.
    4. The measured fluence map verified in patient-specific QA

    Explanation

    Inverse planning works backward from a desired dose distribution: the planner enters target dose goals plus maximum, mean, or dose-volume limits for organs at risk, along with relative weightings. The optimizer then derives the fluence and, after leaf sequencing, the segment shapes and monitor units, which are outputs rather than inputs.

  107. Question 107Treatment Planning

    A bolus is placed over a chest wall scar before treatment. What is the primary effect on the dose distribution?

    1. It shifts the depth of maximum dose to the skin surface Correct answer.
    2. It sharpens the penumbra at the field edges
    3. It attenuates the beam and lowers dose to the underlying lung
    4. It flattens the beam profile across the treatment field

    Explanation

    Bolus material replaces missing tissue or adds tissue-equivalent thickness so that the build-up region develops within the bolus instead of the skin. The depth of maximum dose moves to the skin surface and the surface dose rises toward the prescription level.

  108. Question 108Treatment Planning

    Which image set supplies the Hounsfield unit-to-electron density information needed for inhomogeneity correction in a photon plan?

    1. Diagnostic ultrasound
    2. The planning CT Correct answer.
    3. FDG PET acquired in the treatment position
    4. Non-contrast T1-weighted MRI

    Explanation

    CT numbers are calibrated against electron density through a conversion curve built into the planning system, which is what allows heterogeneity correction in lung, bone, and air cavities. MRI signal intensity and PET uptake have no fixed relationship to electron density and require a separate conversion or assignment step.

  109. Question 109Treatment Planning

    A planner changes the dose calculation grid from 3 mm to 1 mm in the same plan. What is the expected result?

    1. Every isodose line shifts outward at depth by roughly 1 mm
    2. Monitor units for the plan decrease and calculation speeds up
    3. Dose in the build-up region is overestimated more strongly
    4. Dose near small fields and interfaces is modelled better Correct answer.

    Explanation

    A finer grid samples the dose in smaller voxels, so high-gradient regions such as small fields, tissue interfaces, and beam edges are resolved more accurately. The trade-off is a longer calculation time, and monitor units are largely unaffected.

  110. Question 110Treatment Planning

    A planning organ-at-risk volume (PRV) is created by doing which of the following?

    1. Adding a margin around a contoured organ at risk Correct answer.
    2. Expanding the target volume by the setup margin
    3. Subtracting the target volume from an organ at risk
    4. Averaging the organ contour across the breathing cycle

    Explanation

    A PRV applies a geometric margin to an organ at risk so that setup error, motion, and contouring uncertainty do not allow unplanned high dose into the structure. Dose constraints applied to the PRV are therefore more conservative than those applied to the bare contour.

  111. Question 111Treatment Planning

    What does a wedge placed in a photon beam do to the dose distribution?

    1. It narrows the penumbra and improves edge conformity
    2. It tilts the isodose curves across the field Correct answer.
    3. It raises the effective beam energy and deepens the maximum dose
    4. It makes percentage depth dose constant with depth

    Explanation

    A wedge progressively attenuates one side of the beam, tilting the isodose lines by approximately the wedge angle in the plane of the wedge. This compensates for sloping or uneven patient contours and produces more homogeneous dose across the treated volume.

  112. Question 112Treatment Planning

    Two adjacent photon fields treat a continuous volume and are set with a small gap at the skin surface. Why is the gap used?

    1. To account for beam divergence along the match line Correct answer.
    2. To make the two fields overlap purposely at depth
    3. To allow collimator rotation between the two fields
    4. To create a deliberate cold spot along the match line

    Explanation

    Each field diverges from its own source, so fields set abutting at the surface overlap at depth and create a hot band. A small surface gap makes the field edges coincide at the depth of interest, reducing that hot or cold region.

  113. Question 113Treatment Planning

    A small pituitary target is being planned from a simulation CT. Which scan parameter most directly limits target localization in the superior-inferior direction?

    1. Reconstruction field of view
    2. Tube current and gantry rotation time
    3. Peak kilovoltage selected for the scan
    4. Reconstructed slice thickness Correct answer.

    Explanation

    Superior-inferior resolution is set by slice thickness, because each slice averages the tissue within its thickness. Thin slices of roughly 1 to 1.5 mm reduce partial-volume blurring and improve delineation of small targets, at the cost of more images and a higher dose-length product.

  114. Question 114Treatment Planning

    Which statement best explains why respiratory gating lengthens the beam-on time required to deliver a given dose?

    1. The beam is on for only part of each breathing cycle Correct answer.
    2. The dose per monitor unit falls while gating is active
    3. The MLC must retrace its positions for every cycle
    4. The gantry must rotate more slowly during gated delivery

    Explanation

    Gating delivers dose only during a preselected phase or amplitude window, so the duty cycle is less than one and the accelerator must remain on longer to accumulate the required monitor units. Shorter windows improve geometric accuracy but further increase treatment time.

  115. Question 115Treatment Planning

    Using the RTOG definition, the conformity index is which ratio?

    1. Target volume divided by the volume of irradiated normal tissue
    2. Prescription dose divided by the maximum dose in the target
    3. Volume of the prescription isodose divided by the target volume Correct answer.
    4. Volume receiving half the prescription dose divided by target volume

    Explanation

    The RTOG conformity index is the prescription isodose volume divided by the target volume, with 1.0 representing an ideal match. Values greater than 1 indicate that the prescription isodose extends beyond the target into normal tissue.

  116. Question 116Treatment Planning

    An electron cutout measures 6 cm across at the skin surface. What happens to the width of the 90% isodose at 3 cm depth?

    1. It decreases only if the cutout is smaller than the range
    2. It widens because of scatter in the underlying tissue
    3. It stays constant because electrons travel in straight paths
    4. It decreases from lateral scatter and loss of equilibrium Correct answer.

    Explanation

    Electrons scatter laterally as they slow in tissue, so the high-dose region bulges slightly near the surface and then narrows with depth, with the effect greatest for small cutouts and low energies. The 90% isodose is therefore narrower than the cutout at depth.

  117. Question 117Treatment Planning

    In inverse-planned IMRT of the prostate, an annular helper structure is drawn just outside the target. What is its purpose?

    1. To shield the femoral heads from head leakage radiation
    2. To steepen the dose fall-off immediately outside the target Correct answer.
    3. To reduce monitor units by limiting the number of segments
    4. To boost the dose gradient within the peripheral target

    Explanation

    A ring or helper structure placed outside the target is given its own dose objectives, which forces the optimizer to control the intermediate and low dose region and sharpens the fall-off toward nearby organs at risk. It spares structures without blocking the target itself.

  118. Question 118Treatment Planning

    Plan A delivers 60 Gy in 30 fractions and Plan B delivers 55 Gy in 20 fractions to the same tumor, taken as alpha/beta = 10 Gy. Which statement is correct?

    1. Plan B has the higher tumor EQD2, about 66 Gy versus 60 Gy
    2. The plans are biologically equivalent since total doses differ by under 10%
    3. Plan B has the higher tumor EQD2 because dose per fraction is larger
    4. Plan A has the higher tumor EQD2, about 60 Gy versus 58 Gy Correct answer.

    Explanation

    Converting with the linear-quadratic formula, EQD2 = D x (d + alpha/beta)/(2 + alpha/beta). Plan A gives 60 x 12/12 = 60 Gy EQD2, while Plan B gives 55 x 12.75/12 = about 58.4 Gy EQD2, so the conventionally fractionated plan is biologically slightly hotter for the tumor.

  119. Question 119Treatment Planning

    A prostate plan is produced with robust optimization incorporating 5 mm setup uncertainty. What does the optimization do?

    1. It lowers the prescribed dose by the amount uncertainty could lose
    2. It tests shifted geometries and maintains coverage for each Correct answer.
    3. It adds a uniform 5 mm geometric margin to the CTV
    4. It limits the number of beams to make each field less sensitive

    Explanation

    Robust optimization evaluates multiple perturbed copies of the patient geometry, or worst-case scenarios, during optimization itself and selects fluence that keeps target coverage acceptable across them. This replaces or supplements the traditional fixed geometric margin approach.

  120. Question 120Treatment Planning

    Why does Monte Carlo dose calculation differ most from pencil-beam algorithms for a small photon field in lung?

    1. It models lateral electron scatter and loss of equilibrium Correct answer.
    2. It needs a coarser calculation grid to reach convergence
    3. It assumes a homogeneous water medium at all depths
    4. It ignores the electron transport set in motion by photons

    Explanation

    Small fields in low-density lung lack lateral electronic equilibrium, and pencil-beam algorithms approximate scatter with kernels that break down in these conditions. Monte Carlo transports individual particles through the actual geometry, explicitly capturing lateral scatter and the loss of equilibrium.

  121. Question 121Radiation Treatment Delivery

    The isocenter of a medical linear accelerator is best described as which of the following?

    1. The center of the collimator housing at the accessory tray
    2. The point on the patient's skin where the central axis enters
    3. A point that shifts whenever the treatment couch is rotated
    4. A fixed point 100 cm from the source Correct answer.

    Explanation

    The isocenter is the point in space at the nominal source-to-axis distance of 100 cm, and the gantry, collimator, and couch all rotate about it. The patient is positioned so that the target volume coincides with this fixed point. It is independent of patient anatomy and of couch rotation.

  122. Question 122Radiation Treatment Delivery

    With the patient supine, a photon beam directed anterior-to-posterior corresponds to which gantry angle?

    1. 270 degrees
    2. 180 degrees
    3. 0 degrees Correct answer.
    4. 90 degrees

    Explanation

    At a gantry angle of 0 degrees the source is above the patient and the beam travels downward, producing an anterior-to-posterior field. A 180-degree gantry angle gives a posterior-to-anterior field, and 90 and 270 degrees give lateral fields.

  123. Question 123Radiation Treatment Delivery

    The wedge angle of a physical wedge is defined by the angle between which two references?

    1. The wedge tray and the accessory mount
    2. The central axis and the tilted isodose curve Correct answer.
    3. The beam central axis and the collimator rotation axis
    4. The two opposing collimator jaw settings

    Explanation

    The wedge angle describes how much an isodose curve is tilted away from the normal to the central axis, conventionally evaluated at 10 cm depth. It is a dosimetric descriptor, not the physical slope of the wedge face or the tray geometry.

  124. Question 124Radiation Treatment Delivery

    A daily cone-beam CT shows the prostate target sitting 6 mm anterior to the planned position relative to isocenter. Which couch move corrects this?

    1. 6 mm anterior
    2. 6 mm posterior Correct answer.
    3. 6 mm superior
    4. 6 mm lateral

    Explanation

    Couch shifts move the patient, not the isocenter. If the target lies anterior to isocenter, the patient must be moved posteriorly by that same 6 mm so the target falls back onto the isocenter.

  125. Question 125Radiation Treatment Delivery

    Deep inspiration breath hold is used during left breast irradiation primarily to:

    1. Allow a smaller number of fractions to be used
    2. Reduce the dose to the ipsilateral lung apex
    3. Increase the heart-to-field separation Correct answer.
    4. Improve the reproducibility of the arm position

    Explanation

    During a deep breath hold the lungs expand and the diaphragm descends, moving the heart inferiorly and posteriorly away from the tangential fields. This reduces cardiac dose, particularly to the left anterior descending artery. The technique requires a reproducible, monitored breath hold.

  126. Question 126Radiation Treatment Delivery

    The average transmission through a multileaf collimator in a 6 MV photon beam is approximately:

    1. 25% to 30%
    2. 10% to 12%
    3. 0.1%
    4. 1% to 2% Correct answer.

    Explanation

    Leaves are made of thick tungsten alloy that attenuates the primary beam to a few percent or less, with typical average transmission of roughly 1% to 2%. This leakage is small but is modeled in treatment planning because it contributes dose under closed leaves.

  127. Question 127Radiation Treatment Delivery

    Superflab bolus placed on the skin during a photon treatment is used to:

    1. Attenuate the beam to protect underlying tissue
    2. Reduce the penumbra of the beam
    3. Increase the dose rate at the isocenter
    4. Move the depth of maximum dose toward the skin Correct answer.

    Explanation

    Bolus provides scattering material so that electronic equilibrium and the maximum dose occur within the bolus rather than in tissue below the skin. This raises the surface dose, which is useful when the skin or a surgical scar must receive full dose.

  128. Question 128Radiation Treatment Delivery

    During electron beam treatment, the field size at the treatment distance is determined mainly by which component?

    1. The multileaf collimator leaves
    2. The electron applicator in the head Correct answer.
    3. The secondary collimator jaws alone
    4. The shielding block tray insert

    Explanation

    Electron applicators (cones) define the field size at the treatment distance and also collimate scattered electrons close to the patient. Using jaws alone would leave a large penumbra and increased bremsstrahlung contamination.

  129. Question 129Radiation Treatment Delivery

    A block tray is added to a 6 MV field after the monitor units have been calculated. To still deliver the intended dose, the MU value must be:

    1. Increased to compensate for tray attenuation Correct answer.
    2. Decreased because of added scatter from the tray
    3. Left unchanged because trays do not attenuate photons
    4. Increased only if the field size is larger than 20 cm

    Explanation

    Any material in the beam attenuates and scatters photons, so a tray factor (and a block factor, if blocks are present) less than unity is applied. Dividing the prescribed dose by these factors raises the required monitor units.

  130. Question 130Radiation Treatment Delivery

    In craniospinal irradiation, shifting the junction between the cranial and spinal fields slightly on alternate fractions is called:

    1. Wedging
    2. Gapping
    3. Matching
    4. Feathering Correct answer.

    Explanation

    Feathering moves the junction line between fractions so that no single segment of spinal cord repeatedly receives an overdosage or underdosage. A geometric gap is first calculated at the surface so that field edges approximately meet at depth. Moving that gap spreads the inhomogeneity over a longer length of cord.

  131. Question 131Radiation Treatment Delivery

    A photon field is planned to deliver 200 cGy at 100 cm SSD. If the same monitor units are delivered with the patient positioned at 110 cm SSD, what dose is received at the new distance, ignoring other factors?

    1. 200 cGy
    2. 181 cGy
    3. 165 cGy Correct answer.
    4. 220 cGy

    Explanation

    Dose varies inversely with the square of the distance, so the correction factor is (100/110) squared, which equals 0.826. Multiplying 200 cGy by 0.826 gives approximately 165 cGy. Output falls as distance increases.

  132. Question 132Radiation Treatment Delivery

    A tissue-equivalent compensator is placed in the beam for a head and neck treatment in order to:

    1. Increase the dose to the spinal cord
    2. Compensate for missing tissue and contour changes Correct answer.
    3. Reduce the required number of monitor units
    4. Flatten the beam profile across the field

    Explanation

    A compensator mimics the tissue that is absent, such as over the sloping neck, so that the dose distribution at depth is more uniform. It is designed from the patient's contour and the planned field arrangement.

  133. Question 133Radiation Treatment Delivery

    In a non-isocentric SSD treatment, source-to-skin distance is measured:

    1. Along the central axis from source to skin Correct answer.
    2. From the collimator face to the skin surface
    3. From the source to the isocenter of the machine
    4. From the treatment couch top to the skin surface

    Explanation

    SSD setups depend on the distance along the beam central axis from the source to the skin surface, which must be established at set-up and monitored during treatment. The optical distance indicator or a mechanical distance-measuring device is used for this check.

  134. Question 134Radiation Treatment Delivery

    A patient needs treatment of a lesion 1.0 cm deep, but the lowest available electron energy has its 90% depth at 2.5 cm. The best approach is to:

    1. Add bolus to degrade the beam energy Correct answer.
    2. Increase the SSD by 20 cm
    3. Use a higher energy and a larger cone
    4. Rotate the collimator 90 degrees

    Explanation

    Adding bolus material slows the electrons so the high-dose region shifts toward the surface, matching the shallow target. This allows a lesion shallower than the usable depth of the lowest available energy to be treated adequately.

  135. Question 135Radiation Treatment Delivery

    Which factor reflects the change in machine output caused by scattering in the collimator and flattening filter as the jaw setting changes?

    1. Phantom scatter factor (Sp)
    2. Scatter-air ratio
    3. Collimator scatter factor (Sc) Correct answer.
    4. Tissue-air ratio

    Explanation

    The collimator scatter factor accounts for photons scattered in the head of the machine, including the flattening filter and jaws, and it varies with collimator setting. The phantom scatter factor instead reflects scatter generated within the irradiated patient volume. Total relative output behavior is described by the product of the two.

  136. Question 136Radiation Treatment Delivery

    Fractionated intracranial irradiation with a linear accelerator typically uses which immobilization?

    1. A rigid stereotactic frame screwed to the skull
    2. A thermoplastic mask indexed to the couch Correct answer.
    3. An abdominal compression belt
    4. Only skin tattoos with no device

    Explanation

    A thermoplastic mask molded to the face and indexed to the couch provides reproducible head position across many fractions while remaining tolerable. Rigid frame fixation is reserved for single-fraction stereotactic work where skull fixation is required.

  137. Question 137Radiation Treatment Delivery

    Custom photon blocks are cast thick enough to reduce transmission through the block to less than about:

    1. 20% of the primary beam
    2. 35% of the primary beam
    3. 50% of the primary beam
    4. 5% of the primary beam Correct answer.

    Explanation

    Blocks of Lipowitz metal are typically made about five half-value layers thick so that transmission falls to roughly 5% or less of the open-beam value. The required thickness increases with beam energy, and block shape must follow beam divergence.

  138. Question 138Radiation Treatment Delivery

    Respiratory gating delivers beam-on only when:

    1. The gantry reaches 0 degrees
    2. The breathing trace is within a preset window Correct answer.
    3. The couch moves to a new position
    4. The patient holds a breath at end-inspiration

    Explanation

    Gating uses a surrogate signal, such as a belt, camera, or spirometer, and enables the beam during a chosen amplitude or phase window of the breathing cycle. This confines delivery to a reproducible portion of the motion. Breath-hold techniques are related but rely on voluntary suspension of breathing.

  139. Question 139Radiation Treatment Delivery

    A spread-out Bragg peak in proton therapy is produced by:

    1. Placing a scattering foil in the nozzle
    2. Rotating the gantry during delivery
    3. Superimposing beams of different energies Correct answer.
    4. Using a multileaf collimator to shape the field

    Explanation

    Individual Bragg peaks have a narrow depth range, so several beams of different energies and relative weights are combined to create a flat high-dose region across the target thickness. Scattering foils and collimators shape the lateral field rather than the depth distribution.

  140. Question 140Radiation Treatment Delivery

    Volumetric modulated arc therapy is characterized by which of the following?

    1. Gantry rotation with dynamic MLC during beam-on Correct answer.
    2. Fixed fields delivered one after another at one segment each
    3. A single open arc with no modulation of the beam
    4. Static gantry with multiple static MLC segments

    Explanation

    In arc therapy the gantry rotates continuously while the multileaf collimator shapes the aperture and the dose rate is modulated. This produces a highly conformal dose distribution in a short delivery time. Static gantry and fixed-field techniques describe IMRT delivered with step-and-shoot or static fields.

  141. Question 141Radiation Treatment Delivery

    For single-fraction intracranial stereotactic radiosurgery with a linear accelerator, immobilization is typically achieved with:

    1. Vacuum bag molding of the head and neck
    2. A rigid head frame fixed to the skull Correct answer.
    3. A thermoplastic mask indexed to the couch
    4. A bite block and chin strap

    Explanation

    Single-fraction radiosurgery demands near-rigid fixation with a stereotactic coordinate system referenced to the skull, usually an invasive frame. Non-invasive masks are appropriate for fractionated stereotactic treatments, where some repositioning uncertainty can be managed by imaging.

  142. Question 142Radiation Treatment Delivery

    A lead cutout inserted into an electron cone must be thick enough to:

    1. Convert the electron beam into a photon beam
    2. Flatten the electron fluence across the field
    3. Increase the surface dose beneath the shield
    4. Stop the electrons to limit transmission Correct answer.

    Explanation

    The cutout thickness needed increases with electron energy and is chosen so the electrons are absorbed, leaving only a small bremsstrahlung tail beneath the shield. This protects the tissue that must be excluded from the field.

  143. Question 143Radiation Treatment Delivery

    Total body irradiation is often delivered at a low dose rate of roughly 10 to 20 cGy per minute mainly because:

    1. Lower dose rates increase the biologic effect on tumor cells
    2. Lower dose rates reduce pulmonary and acute toxicity Correct answer.
    3. The linac cannot produce higher output at extended distance
    4. Low dose rate eliminates the need for compensators

    Explanation

    Slower delivery reduces acute effects such as nausea and parotitis and lowers the risk of interstitial pneumonitis. Extended treatment distance naturally lowers output, which helps achieve these low dose rates. Patient-specific compensators are still required because of inverse-square and thickness differences along the body.

  144. Question 144Radiation Treatment Delivery

    Compared with portal imaging using an electronic portal imaging device, cone-beam CT provides:

    1. Three-dimensional soft-tissue information Correct answer.
    2. Faster acquisition than a single portal image
    3. A lower imaging dose than a single radiograph
    4. Two-dimensional projection images only

    Explanation

    Cone-beam CT reconstructs a volumetric image set, allowing soft-tissue alignment in three dimensions rather than relying on bony landmarks in a single projection. This improves verification for targets not tightly coupled to bone. It generally delivers more dose than a single planar image.

  145. Question 145Radiation Treatment Delivery

    In lung stereotactic body radiation therapy, the internal target volume is designed to account for:

    1. Penumbra outside the planning target volume
    2. Uncertainty in the CT-number calibration
    3. Tumor motion during the breathing cycle Correct answer.
    4. Set-up error seen on daily kV imaging

    Explanation

    The internal target volume is the envelope of gross tumor positions through the breathing cycle, typically derived from a four-dimensional CT. It addresses motion of the target itself, while set-up and other uncertainties are handled by additional margins. This allows adequate coverage without excessive normal-tissue irradiation.

  146. Question 146Radiation Treatment Delivery

    In an isocentric treatment technique, the gantry, collimator, and couch all rotate about a point that lies a fixed distance from the radiation source. That distance is:

    1. 120 cm
    2. 80 cm
    3. 150 cm
    4. 100 cm Correct answer.

    Explanation

    The isocenter is the point in space where the three axes of rotation intersect, and for a standard linear accelerator it lies 100 cm from the source along the central axis. The patient's target volume is positioned at that point so the beam can be directed from any gantry angle without moving the patient.

  147. Question 147Radiation Treatment Delivery

    The main purpose of a wedge filter placed in a photon beam is to:

    1. Flatten the beam profile at the surface
    2. Reduce transmission through the field to protect a structure
    3. Tilt the isodose distribution across the field Correct answer.
    4. Increase the beam penetration across the field

    Explanation

    A wedge is an attenuator of varying thickness that makes one side of the beam more attenuated than the other, tilting the isodose curves toward the thin edge. This is used when the treatment volume lies on a sloped surface or when two fields need to be angled to produce a uniform dose.

  148. Question 148Radiation Treatment Delivery

    A patient receiving daily pelvic irradiation needs a device that will reproduce a stable, comfortable position of the hips and legs from fraction to fraction. The most appropriate choice is:

    1. A bite block with a hard palate impression
    2. A stereotactic head frame fixed to the skull
    3. A thermoplastic mask over the head and neck
    4. A vacuum-locked beanbag cushion Correct answer.

    Explanation

    A vacuum cushion moulds to the contour of the pelvis and lower body and becomes rigid when air is evacuated, giving reproducible support of a large, irregular region. It is well suited to pelvic and lower-extremity treatments because it accommodates the patient's shape and leg position.

  149. Question 149Radiation Treatment Delivery

    An in vivo measurement made with a diode placed on the skin during a photon treatment is most useful for:

    1. quantifying electron contamination in the beam
    2. establishing the wedge factor for the field
    3. estimating the beam energy spectrum at depth
    4. verifying the delivered dose against the plan Correct answer.

    Explanation

    An in vivo dosimeter measures the actual dose received at its location during a real treatment, and that reading is compared with the value predicted by the treatment plan. Discrepancies flag errors in monitor units, accessories, field size, or patient setup.

  150. Question 150Radiation Treatment Delivery

    In a half-beam (split-beam) technique, one jaw is closed to the central axis. The chief advantage of this arrangement when two fields must abut is that:

    1. the penumbra is removed from the field edge
    2. the beam does not diverge past the match plane Correct answer.
    3. the beam energy falls off sharply at the field edge
    4. the collimator scatter is eliminated at the match plane

    Explanation

    With a jaw positioned at the central axis, the field edge is defined by a plane containing the central axis, so the beam does not flare outward beyond that plane. Two half-beam fields can therefore be matched without overlap or gap at depth.

  151. Question 151Radiation Treatment Delivery

    A field requires 200 monitor units to deliver the prescribed dose without a wedge. If the wedge factor for the wedge used is 0.50, how many monitor units must be delivered with the wedge in place?

    1. 100 MU
    2. 400 MU Correct answer.
    3. 250 MU
    4. 800 MU

    Explanation

    The wedge attenuates the beam, so the monitor units must be divided by the wedge factor: 200 / 0.50 = 400 MU. Use of a wedge always increases the required monitor units relative to the open field.

  152. Question 152Radiation Treatment Delivery

    Deep inspiration breath hold is used during tangential irradiation of the left breast primarily to:

    1. eliminate the need for a tumor bed boost
    2. increase the distance between the heart and the treatment fields Correct answer.
    3. shorten the overall treatment time
    4. increase the dose to the internal mammary chain

    Explanation

    Taking a deep breath expands the lungs and moves the heart inferiorly and posteriorly, away from the tangential field edges. This reduces the volume of heart and left anterior descending artery included in the high-dose region.

  153. Question 153Radiation Treatment Delivery

    At each treatment, the therapist positions the patient by aligning the tattooed skin marks with the:

    1. immobilization device straps
    2. wall and ceiling lasers Correct answer.
    3. gantry angle digital readout
    4. field light crosshair on the skin

    Explanation

    The treatment room lasers are aligned to the isocenter, and matching the tattooed reference marks to the laser lines reproduces the planned isocenter position. Small couch translations are then made to correct any offset.

  154. Question 154Radiation Treatment Delivery

    During step-and-shoot (segment-based) intensity-modulated delivery, the radiation beam is:

    1. turned off while the leaves move between segments Correct answer.
    2. delivered only while the gantry is rotating
    3. left on continuously while the leaves sweep across the field
    4. attenuated by physical compensators rather than by leaves

    Explanation

    In step-and-shoot delivery each field is broken into fixed leaf patterns, and the beam is interrupted while the multileaf collimator travels to the next segment. Dose is delivered only with the leaves stationary in the programmed segment shape.

  155. Question 155Radiation Treatment Delivery

    In the six-dual-field total skin electron technique, the patient is treated:

    1. standing in several prescribed positions Correct answer.
    2. seated with the head turned between fields
    3. lying supine on the couch with the gantry at 0 degrees
    4. prone on a vacuum cushion with a downward beam

    Explanation

    Total skin electron therapy is delivered at an extended distance with the patient standing in a series of prescribed orientations, such as anterior, posterior, and oblique pairs, so that the entire skin surface is covered. Each position contributes a fraction of the total prescription.

  156. Question 156Radiation Treatment Delivery

    A linear accelerator used for photon therapy is calibrated so that 1 monitor unit corresponds to:

    1. 1 cGy at 10 cm depth in water for the reference field
    2. 1 cGy at the skin surface for a 10 x 10 cm field
    3. 1 cGy at dmax in water for the reference field Correct answer.
    4. 1 Gy at the isocenter for any field size

    Explanation

    Conventional linac calibration establishes that 1 MU delivers 1 cGy at the depth of maximum dose in water at the calibration distance for the reference field. Other field sizes and depths are then handled with output factors, percentage depth dose, and inverse square corrections.

  157. Question 157Radiation Treatment Delivery

    The wedge angle of a physical wedge is defined as the angle between:

    1. the two angled faces of the wedge filter itself
    2. the central axis and the tilted isodose at 10 cm Correct answer.
    3. the central axis and the geometric field edge at the surface
    4. the central axis and the 50% isodose line at dmax

    Explanation

    The wedge angle is a dosimetric specification, defined as the angle between the central axis and the isodose curve that has been tilted by the wedge, measured at a reference depth of 10 cm. It therefore describes the resulting dose distribution rather than the physical shape of the filter.

  158. Question 158Radiation Treatment Delivery

    Two diverging photon fields must abut along a long treatment volume. To avoid an overdose at depth where the field edges converge, the separation set on the skin is calculated at:

    1. the skin surface, where the beam edges diverge least
    2. the depth of the midplane of the treated volume Correct answer.
    3. the nominal source-to-axis calibration depth
    4. the depth of maximum dose on the central axis

    Explanation

    Because each field edge diverges, edges that just touch at the skin overlap below the surface while leaving a cold gap above it. The skin gap is therefore computed for the depth where the two treated volumes meet, usually the midplane of the junction region, so the fields abut at the clinically important depth.

  159. Question 159Radiation Treatment Delivery

    Compared with a physical wedge, an enhanced dynamic wedge produces a similar isodose tilt with:

    1. greater beam hardening and a larger change in output
    2. no change in the required monitor units
    3. less beam hardening and less scattered radiation Correct answer.
    4. a larger penumbra at the field edges

    Explanation

    An enhanced dynamic wedge creates the tilt by driving a jaw across the field during irradiation, so no metal wedge sits in the beam. The beam is therefore not hardened and produces less scatter than a physical wedge, while the delivered isodose distribution is comparable.

  160. Question 160Radiation Treatment Delivery

    A 6 MV field is treated at 100 cm SSD. The percentage depth dose at 8 cm is 70%, and the output is 1 cGy/MU at dmax for this field size. How many monitor units are needed to deliver 200 cGy at 8 cm depth?

    1. 200 MU
    2. 286 MU Correct answer.
    3. 350 MU
    4. 140 MU

    Explanation

    The dose rate at depth equals the output multiplied by the percentage depth dose expressed as a decimal, or 0.70 cGy/MU. Dividing the prescribed dose by this value gives 200 / 0.70, which is approximately 286 MU.

  161. Question 161Dosimetry and Quality Assurance

    If the distance from a point source is doubled, the dose rate becomes:

    1. one-quarter of the original Correct answer.
    2. four times the original
    3. one-half of the original
    4. twice the original

    Explanation

    Dose rate from a point source follows the inverse-square law, so it is proportional to 1/d². Doubling d multiplies the dose rate by 1/2² = 1/4.

  162. Question 162Dosimetry and Quality Assurance

    Percentage depth dose (PDD) is defined as the dose at a given depth expressed as a percentage of the dose at:

    1. the 10-cm depth dose
    2. the entrance surface dose
    3. the isocenter dose
    4. the dose at dmax Correct answer.

    Explanation

    PDD is measured along the central axis at a fixed source-to-surface distance and normalized to the dose at the depth of maximum dose, dmax. It always has a value of 100% at dmax.

  163. Question 163Dosimetry and Quality Assurance

    Tissue maximum ratio (TMR) is the ratio of the dose at a given depth to the dose:

    1. at the same point in air at the same SAD
    2. at dmax in a phantom at the same SAD Correct answer.
    3. at 10 cm depth at the same field size
    4. at the surface at the same SSD

    Explanation

    TMR compares the dose at depth in a phantom to the dose at dmax for the same source-to-axis distance and the same field size at the depth. It is the special case of TPR referenced to dmax.

  164. Question 164Dosimetry and Quality Assurance

    Which material is placed directly on the patient's skin to increase surface dose and compensate for missing tissue?

    1. Bolus Correct answer.
    2. Block
    3. Wedge
    4. Compensator

    Explanation

    Bolus is a tissue-equivalent material placed on the skin to build up dose at the surface and fill in missing tissue. Compensators and wedges are placed in the beam path, not on the skin.

  165. Question 165Dosimetry and Quality Assurance

    The typical daily QA tolerance for photon output constancy on a medical linear accelerator is:

    1. ±5%
    2. ±3% Correct answer.
    3. ±1%
    4. ±10%

    Explanation

    Daily output constancy is usually checked with a tolerance of ±3% in TG-142-based programs. Larger deviations trigger investigation before clinical use.

  166. Question 166Dosimetry and Quality Assurance

    Which beam delivers the highest relative surface dose?

    1. Cobalt-60 gamma
    2. 18 MV photon
    3. 6 MV photon
    4. 6 MeV electron Correct answer.

    Explanation

    Electron beams reach dmax very close to the surface, so the surface dose is high-often 80% or more. Megavoltage photon beams have a lower surface dose because of the build-up region.

  167. Question 167Dosimetry and Quality Assurance

    A beam output is 1.0 cGy/MU at dmax. How many monitor units are needed to deliver 200 cGy at dmax?

    1. 100 MU
    2. 400 MU
    3. 200 MU Correct answer.
    4. 150 MU

    Explanation

    MU are calculated by dividing the prescribed dose by the output at the point of interest: 200 cGy ÷ 1.0 cGy/MU = 200 MU. No other factors are given, so the calculation is direct.

  168. Question 168Dosimetry and Quality Assurance

    The wedge factor is defined as the ratio of:

    1. wedged-beam dose divided by open-beam dose Correct answer.
    2. 10-cm dose divided by dmax dose with the wedge in place
    3. thin-edge dose divided by thick-edge dose
    4. open-beam dose divided by wedged-beam dose

    Explanation

    Wedge factor is the ratio of dose at a point with the wedge in place to dose at the same point without the wedge, measured at the same depth and field size. It is used to convert open-beam MU to wedged-beam MU.

  169. Question 169Dosimetry and Quality Assurance

    For a fixed SSD and beam energy, increasing field size from 10×10 cm to 20×20 cm typically:

    1. leaves PDD unchanged because only energy matters
    2. increases PDD only at the surface
    3. increases PDD at 10 cm because of greater scatter Correct answer.
    4. decreases PDD at 10 cm because of greater attenuation

    Explanation

    A larger field produces more scattered photons that contribute dose at depth, so PDD at a given depth increases. The effect is most pronounced for larger fields and lower energies.

  170. Question 170Dosimetry and Quality Assurance

    The temperature-pressure correction factor for an ion chamber is calculated as:

    1. P0/P × (T+273.15)/(T0+273.15) Correct answer.
    2. P/P0 × (T0+273.15)/(T+273.15)
    3. P/P0 × T/T0
    4. T/T0 only

    Explanation

    The correction accounts for the mass of air in the chamber volume, which depends on pressure and absolute temperature. The standard form multiplies by P0/P and by (T+273.15)/(T0+273.15).

  171. Question 171Dosimetry and Quality Assurance

    In TG-51, the reference calibration geometry for a photon beam uses a 10×10 cm field at:

    1. 10 cm depth with SSD 80 cm
    2. dmax with SSD 100 cm
    3. 10 cm depth with SSD 100 cm Correct answer.
    4. 5 cm depth with SSD 100 cm

    Explanation

    TG-51 specifies a 10×10 cm field, 10 cm depth, and 100 cm source-to-chamber distance for the reference photon calibration. The chamber is then corrected to reference conditions.

  172. Question 172Dosimetry and Quality Assurance

    Which detector is preferred for measuring electron beam depth-dose curves because of its thin window and small perturbation?

    1. Farmer chamber
    2. Well chamber
    3. Optically stimulated luminescent dosimeter
    4. Parallel-plate chamber Correct answer.

    Explanation

    Parallel-plate chambers have a thin entrance window and a small measurement volume, which reduces perturbation and improves spatial resolution in electron beams. They are especially useful in the steep dose gradient near the surface.

  173. Question 173Dosimetry and Quality Assurance

    In patient-specific IMRT QA, a gamma index of 3%/3 mm means:

    1. 3% dose difference and 3 mm distance-to-agreement Correct answer.
    2. 3% monitor units and 3 mm leaf position
    3. 3 mm dose difference and 3% distance-to-agreement
    4. 3% dose rate and 3 mm field size

    Explanation

    Gamma analysis combines a dose-difference criterion and a distance-to-agreement criterion. The notation 3%/3 mm means a 3% dose difference and a 3 mm spatial tolerance.

  174. Question 174Dosimetry and Quality Assurance

    The TG-142 tolerance for static MLC leaf position accuracy is:

    1. 1 mm Correct answer.
    2. 5 mm
    3. 2 mm
    4. 0.1 mm

    Explanation

    TG-142 recommends a tolerance of 1 mm for MLC leaf position accuracy in the static test. This ensures that leaf placement matches the planned field shape.

  175. Question 175Dosimetry and Quality Assurance

    In a CT image used for treatment planning, water is assigned a Hounsfield unit of:

    1. −100
    2. −1000
    3. 1000
    4. 0 Correct answer.

    Explanation

    The Hounsfield scale is defined with water at 0 HU and air at approximately −1000 HU. Treatment planning systems use HU-to-electron-density conversions for dose calculation.

  176. Question 176Dosimetry and Quality Assurance

    The half-value layer of a beam is the thickness of material that:

    1. reduces the intensity to 50% Correct answer.
    2. reduces the beam energy by half
    3. increases the dose to dmax
    4. reduces the dose rate to 25%

    Explanation

    The half-value layer is the thickness of a specified material that attenuates the beam intensity to one-half of its original value. It is a measure of beam quality and penetrating ability.

  177. Question 177Dosimetry and Quality Assurance

    The half-life of cobalt-60 used in teletherapy is approximately:

    1. 5.26 years Correct answer.
    2. 30 years
    3. 1.27 years
    4. 10.5 years

    Explanation

    Cobalt-60 has a half-life of about 5.26 years, so its output decays measurably over its clinical life. Source activity must be accounted for in treatment time calculations.

  178. Question 178Dosimetry and Quality Assurance

    In the TG-43 formalism for brachytherapy, the dose rate constant Λ has units of:

    1. Gy cm²
    2. cGy h⁻¹
    3. U mm²
    4. cGy h⁻¹ U⁻¹ Correct answer.

    Explanation

    The dose rate constant converts air-kerma strength in U into dose rate near the source, so its units are cGy h⁻¹ U⁻¹. TG-43 uses this constant along with geometry, anisotropy, and radial dose functions.

  179. Question 179Dosimetry and Quality Assurance

    A compensator placed in the beam is used primarily to:

    1. increase surface dose
    2. flatten the beam profile across the entire field
    3. compensate for missing tissue and heterogeneity Correct answer.
    4. reduce penumbra

    Explanation

    Compensators modify the beam fluence to account for missing tissue, irregular surfaces, and tissue heterogeneity, producing a more uniform dose distribution. They are not the same as bolus, which sits on the skin.

  180. Question 180Dosimetry and Quality Assurance

    Photon beam flatness and symmetry are typically evaluated using:

    1. a single ion chamber at dmax
    2. a 2D array or film scanned across the beam Correct answer.
    3. a Geiger-Mueller counter
    4. a well chamber

    Explanation

    Flatness and symmetry require a profile measurement across the beam at a specified depth, so a 2D detector array or film is used. A single chamber would require many point measurements and is less efficient.

  181. Question 181Dosimetry and Quality Assurance

    A 6 MV photon beam typically has a TPR20/10 of about:

    1. 0.50
    2. 0.80
    3. 0.67 Correct answer.
    4. 1.00

    Explanation

    TPR20/10 is the ratio of dose at 20 cm to dose at 10 cm at a fixed SAD and is a beam-quality index. For 6 MV photons it is approximately 0.67, increasing with energy.

  182. Question 182Dosimetry and Quality Assurance

    When a treatment planning system reports dose to medium rather than dose to water, the difference is largest in:

    1. water phantom and soft tissue
    2. bone and air cavities Correct answer.
    3. soft tissue
    4. fat only

    Explanation

    Dose to medium differs from dose to water because of differences in mass energy absorption and stopping power ratios. These differences are greatest in bone and air, where composition and density differ most from water.

  183. Question 183Dosimetry and Quality Assurance

    A diode detector used for in vivo dosimetry requires correction for:

    1. pressure only
    2. magnetic field and humidity
    3. temperature and dose rate Correct answer.
    4. humidity only

    Explanation

    Diode response varies with temperature and dose rate, so both corrections are applied when diodes are used for in vivo dose measurements. Energy dependence may also require correction.

  184. Question 184Dosimetry and Quality Assurance

    An end-to-end test in radiation therapy is designed to:

    1. calibrate the linac output and energy only
    2. verify only the CT scanner
    3. check only the treatment planning system
    4. verify the full imaging-to-delivery chain Correct answer.

    Explanation

    An end-to-end test uses a phantom through the full clinical workflow-imaging, planning, and delivery-to confirm that the integrated system produces the intended dose. It detects errors that component-specific QA may miss.

  185. Question 185Dosimetry and Quality Assurance

    Small-field photon output factors are difficult to measure because:

    1. the PDD becomes independent of depth
    2. the beam energy increases sharply
    3. the inverse-square law no longer applies
    4. loss of lateral electronic equilibrium Correct answer.

    Explanation

    In small fields, the range of secondary electrons exceeds the field width, so lateral electronic equilibrium is not established. Detectors with finite volume average over steep gradients and perturb the field, making output factors hard to measure accurately.

  186. Question 186Dosimetry and Quality Assurance

    Which quantity is expressed in units of cGy·cm²·h⁻¹?

    1. Reference air kerma rate
    2. Air kerma strength Correct answer.
    3. Radial dose function
    4. Dose rate constant

    Explanation

    Air kerma strength is the product of air kerma rate at a reference distance and the square of that distance, giving units of cGy·cm²·h⁻¹ (1 U = 1 cGy·cm²·h⁻¹). The dose rate constant instead has units of cGy·h⁻¹·U⁻¹.

  187. Question 187Dosimetry and Quality Assurance

    According to TG-142, how often should photon output constancy of a linear accelerator be checked?

    1. Weekly
    2. Daily Correct answer.
    3. Monthly
    4. Annually

    Explanation

    TG-142 lists photon and electron output constancy among the daily quality control tests performed before patient treatment. Less frequent testing would allow an undetected calibration drift to affect many patients.

  188. Question 188Dosimetry and Quality Assurance

    A bolus is placed on a patient's skin primarily to:

    1. Bring the dose build-up region to the skin surface Correct answer.
    2. Reduce the dose delivered to underlying normal tissue
    3. Improve the mechanical stability of the treatment setup
    4. Flatten the beam profile across the treatment field

    Explanation

    Bolus is tissue-equivalent material that shifts the depth of maximum dose toward the skin so that superficial tissue receives a therapeutic dose. It acts by providing the missing build-up material rather than by altering beam shape or setup stability.

  189. Question 189Dosimetry and Quality Assurance

    The penumbra of a photon beam describes:

    1. The collimator-defined geometric field boundary
    2. The 80% to 20% dose fall-off at the field edge Correct answer.
    3. The flat central portion of the beam profile
    4. The depth at which the dose reaches its maximum

    Explanation

    Penumbra is the region of rapid dose change at the field border, conventionally measured between the 80% and 20% isodose lines. It arises from finite source size, scatter, and geometric divergence.

  190. Question 190Dosimetry and Quality Assurance

    A beam is calibrated to deliver 1.00 cGy/MU at dmax at 100 cm from the source. Ignoring all other factors, what is the approximate dose per MU at the same depth when the point is moved to 150 cm?

    1. 2.25 cGy/MU
    2. 0.44 cGy/MU Correct answer.
    3. 1.50 cGy/MU
    4. 0.67 cGy/MU

    Explanation

    Dose rate follows the inverse square law, so the factor is (100/150)² = 0.444, giving about 0.44 cGy/MU. Distance ratios must be squared because the fluence spreads over an area that grows with the square of distance.

  191. Question 191Dosimetry and Quality Assurance

    A rectangular photon field measures 10 × 20 cm. Its equivalent square field size is approximately:

    1. 10 cm
    2. 13 cm Correct answer.
    3. 20 cm
    4. 15 cm

    Explanation

    The equivalent square is found from 2ab/(a+b) or 4A/P, giving 400/30 ≈ 13.3 cm. This square field produces about the same scatter conditions as the rectangle.

  192. Question 192Dosimetry and Quality Assurance

    A patient is treated isocentrically at 100 cm SAD with a beam whose calibrated output is 1.00 cGy/MU at dmax. The tissue-maximum ratio at the prescription depth is 0.78, and the collimator and phantom scatter factors are both 1.00. How many monitor units are required to deliver 180 cGy to the isocenter?

    1. 180 MU
    2. 141 MU
    3. 282 MU
    4. 231 MU Correct answer.

    Explanation

    For an isocentric calculation, MU = dose / (output × TMR × Sc × Sp), giving 180/(1.00 × 0.78) ≈ 231 MU. The TMR accounts for attenuation and scatter between dmax and the prescription depth.

  193. Question 193Dosimetry and Quality Assurance

    The wedge angle is defined as the angle between:

    1. The 50% isodose curve and the field edge
    2. An isodose curve and the horizontal at 10 cm depth Correct answer.
    3. The two faces of the wedge filter
    4. The central axis and the collimator rotation axis

    Explanation

    The wedge angle is the angle through which an isodose curve is tilted relative to a line perpendicular to the central axis, conventionally measured at 10 cm depth. It describes the shape of the dose distribution rather than the physical shape of the filter.

  194. Question 194Dosimetry and Quality Assurance

    A star shot test is performed to evaluate:

    1. Accuracy of the electron cone cutout factor
    2. Linearity of the monitor chamber response
    3. Alignment of the treatment couch with the wall lasers
    4. Coincidence of the radiation and mechanical isocenters Correct answer.

    Explanation

    In a star shot, the collimator or gantry is rotated while a narrow slit is irradiated, and any offset between the radiation and mechanical axes appears as a spoke pattern rather than a single line. The size of the pattern quantifies isocentric misalignment.

  195. Question 195Dosimetry and Quality Assurance

    Compared with a 6 MV photon beam of the same field size, a 10 MV beam has:

    1. A higher surface dose and a deeper depth of maximum dose
    2. A lower surface dose and a deeper depth of maximum dose Correct answer.
    3. A higher surface dose and a shallower depth of maximum dose
    4. A lower surface dose and a shallower depth of maximum dose

    Explanation

    As photon energy increases, the range of secondary electrons rises, pushing dmax deeper and reducing the relative dose at the surface. This is why higher energies spare skin more but require bolus when surface dose matters.

  196. Question 196Dosimetry and Quality Assurance

    A dose-volume histogram metric reported as D95 refers to the:

    1. Dose delivered during 95% of the treatment fractions
    2. Dose that 95% of patients tolerate without complication
    3. Dose received by 95% of the structure volume Correct answer.
    4. Volume of the structure receiving 95% of the prescription dose

    Explanation

    In DVH nomenclature, D followed by a percentage denotes the dose received by that percentage of the structure volume, so D95 is the dose covering 95% of the volume. Volume-based metrics such as V20 use the reverse convention.

  197. Question 197Dosimetry and Quality Assurance

    Which dosimeter is best suited for a two-dimensional, high-spatial-resolution measurement of a complete treatment plan dose distribution inside a phantom?

    1. A Farmer-type ionization chamber
    2. An optically stimulated luminescence dosimeter
    3. A thermoluminescent dosimeter chip
    4. Radiochromic film Correct answer.

    Explanation

    Radiochromic film provides a continuous two-dimensional dose map with sub-millimeter resolution and near tissue-equivalence, making it well suited to film phantom verification. Point detectors sample only one location per measurement.

  198. Question 198Dosimetry and Quality Assurance

    An HDR iridium-192 source has an air kerma strength of 40,000 U. Approximately what is its air kerma strength after 74 days, given a half-life of about 74 days?

    1. 36,000 U
    2. 10,000 U
    3. 20,000 U Correct answer.
    4. 28,000 U

    Explanation

    One half-life of 74 days reduces activity, and therefore air kerma strength, by half, so the source falls from 40,000 U to about 20,000 U. Source strength is corrected with the decay factor 2^(−t/T½) when planning later treatments.

  199. Question 199Dosimetry and Quality Assurance

    For a 6 MV photon beam, the calculated dose on the central axis beyond a large region of low-density lung, compared with a homogeneous water calculation, is generally:

    1. Unchanged, because the calculation point remains at a fixed depth
    2. Higher, because the electron density of lung exceeds that of water
    3. Higher, because fewer photons are attenuated Correct answer.
    4. Lower, because less scattered radiation reaches the point

    Explanation

    Lung has a much lower density than water, so photon attenuation along the path is reduced and the central-axis dose beyond the lung is typically higher than a water-based calculation predicts. Near the field edges the loss of lateral scatter can locally reduce dose, which is why heterogeneity algorithms matter.

  200. Question 200Dosimetry and Quality Assurance

    In the TG-43 formalism, the radial dose function g(r) primarily accounts for:

    1. The dose rate constant of the source
    2. The anisotropy of the emitted fluence around the source
    3. Attenuation and scatter in the surrounding medium along the transverse axis Correct answer.
    4. The geometry of the source encapsulation

    Explanation

    The radial dose function captures photon attenuation and scatter in the medium as a function of distance along the transverse axis, normalized to unity at 1 cm. The inverse square fall-off itself is handled separately by the geometry function.

ARRT Radiation Therapy flashcards

32 cards. Read the term and the definition here. The deck at the top of this page is optional.

Alopecia onset after radiation
Scalp hair loss typically begins 2 to 3 weeks after the first conventionally fractionated treatment; regrowth usually occurs 2 to 3 months after therapy ends unless scalp dose exceeds tolerance.
Mucositis peak timing
Oral mucositis usually appears 10 to 14 days after starting radiation, peaks at 2 to 3 weeks, and heals 2 to 4 weeks after completion if dose stays within mucosal tolerance.
Radiation dermatitis progression
Erythema appears at roughly 10 to 15 fractions, dry desquamation near 30 to 40 Gy, and moist desquamation above 40 Gy when basal layer cells are depleted faster than they regenerate.
Informed consent elements
Valid consent documents diagnosis, treatment intent and technique, expected benefits, material risks, alternatives including no treatment, and confirmation the patient may withdraw at any time.
Nutrition referral threshold
Weight loss exceeding 5% of pre-treatment body weight during a radiation course warrants dietitian referral and consideration of oral supplements or enteral feeding.
Irradiated skin care rule
Wash treated skin with lukewarm water and mild soap, pat dry, and avoid sun, heat, friction, and adhesive tape; protect skin markings from being washed off.
Occupational annual dose limits
NCRP 116 limits for radiation workers are 50 mSv total effective dose per year, 150 mSv to the lens of the eye, and 500 mSv to skin and extremities.
Public dose limit
Members of the public may receive no more than 1 mSv (100 mrem) per year from a licensed facility and no more than 0.02 mSv (2 mrem) in any one hour.
Inverse square law
Exposure rate from a point source varies inversely with the square of distance: I1/I2 = (d2/d1)², so doubling distance reduces exposure to one quarter.
Half-value layer formula
Half-value layer equals 0.693 divided by the linear attenuation coefficient, and transmitted intensity follows I = I0e^(−μx) through thickness x.
Radiation area posting thresholds
Areas exceeding 0.05 mSv/h (5 mrem/h) at 30 cm are posted 'Caution: Radiation Area'; areas above 1 mSv/h (100 mrem/h) are posted 'High Radiation Area'.
Permanent implant release criteria
A patient with a permanent brachytherapy implant may be released if the estimated dose to another person is unlikely to exceed 5 mSv (500 mrem) and written instructions are given.
Gross tumor volume definition
Gross tumor volume is the visible or palpable extent of tumor shown by imaging or clinical examination; it excludes microscopic spread and subclinical disease.
Van Herk margin formula
PTV margin equals 2.5 times the systematic error standard deviation plus 0.7 times the random error standard deviation, giving 95% CTV coverage in 90% of patients.
Spinal cord dose tolerance
With conventional fractionation the spinal cord maximum point dose should stay at or below 50 Gy, or 45 Gy to the full cord cross-section, to limit myelopathy risk.
Parotid gland constraint
Keeping mean parotid dose below 26 Gy, or at least one gland below 20 Gy, reduces the risk of grade 2 or worse xerostomia after head and neck irradiation.
Electron practical range rule
In water, practical range in centimeters is roughly the electron energy in MeV divided by 2, and the 90% depth dose falls near E/3 to E/4 centimeters.
Equivalent square field size
The equivalent square side S equals 2ab/(a+b), where a and b are the rectangular field dimensions; it is used for percent depth dose and scatter factor lookups.
Purpose of bolus
Bolus on the skin builds up dose in the buildup region so superficial lesions receive full prescription dose, and it can compensate for irregular surface contour.
Daily output constancy tolerance
TG-142 sets daily photon output constancy at plus or minus 3% of baseline, monthly output at plus or minus 2%, and annual calibration at plus or minus 1%.
Winston-Lutz test
An SRS and SBRT quality assurance test confirming the radiation field center matches mechanical isocenter within 1 mm across multiple gantry, collimator, and couch angles.
Total body irradiation dose rate
Total body irradiation is commonly delivered at 5 to 10 cGy per minute to reduce pulmonary toxicity; 12 Gy in 6 fractions over 3 days is a frequent pre-transplant regimen.
Deep inspiration breath hold
Breath hold at deep inspiration increases the distance between heart and chest wall, lowering mean cardiac dose during left breast irradiation and reducing late cardiac risk.
SBRT localization requirement
SBRT demands isocentric target localization within 1 mm, usually achieved with cone-beam CT or orthogonal imaging plus 6D couch correction before every fraction.
VMAT delivery concept
Volumetric modulated arc therapy rotates the gantry while continuously varying dose rate, gantry speed, and multileaf collimator positions to produce a conformal dose distribution.
Half-beam block purpose
A half-beam block places the collimated field edge at midline so adjacent fields, such as cranial and spinal fields, match without divergent overlap in the junction region.
TG-51 reference calibration
Photon calibration uses 10 cm depth in water, 100 cm SSD, a 10 × 10 cm field, and Dw = M·N_Dw·P_ion·P_tp·P_elec·P_pol with a 0.6 cc ion chamber.
Monitor unit calculation
MU equals prescribed dose divided by the product of calibrated output, TMR at depth, collimator and phantom scatter factors, wedge factor, and inverse-square correction.
TMR from percent depth dose
TMR(d,r) = (%DD/100) × ((SSD+d)/(SSD+dmax))² × (Sp(dmax)/Sp(d)), converting depth dose measured at fixed SSD into tissue-maximum ratio.
Gamma index criterion
The gamma index combines dose difference and distance-to-agreement; 3%/3 mm with at least 95% of points passing is standard IMRT QA acceptance, while SBRT often uses 2%/2 mm.
Iodine-125 characteristics
I-125 decays by electron capture with a 59.4-day half-life and emits photons averaging about 28 keV, giving low penetration suitable for permanent prostate implants.
TG-43 dose formalism
Brachytherapy dose is D(r,θ) = Sk·Λ·[G(r,θ)/G(r0,θ0)]·g(r)·F(r,θ), where Λ is the dose-rate constant, g the radial function, and F the anisotropy function.

ARRT Radiation Therapy study guide

Patient Care and Education

Core concepts

Patient care items test whether you can assess a patient before, during, and after a course of radiation therapy and act on what you find. Know the acute (early) reactions - radiation dermatitis, fatigue, oral mucositis, xerostomia, esophagitis, nausea, diarrhea, cystitis - and distinguish them from late effects such as fibrosis, persistent xerostomia, and second malignancy. Be able to describe skin-reaction grading and the standard skin-care teaching: cleanse with lukewarm water and mild soap, pat dry, avoid sun, avoid metal-containing or irritating products in the treatment field, and never scrub ink marks.

Also expect: informed consent (obtained by the physician, documented, patient competent and informed of risks/alternatives), teach-back verification of understanding, lay-language education, nutritional and hydration counseling, psychosocial and financial referral, pain assessment, age-specific and culturally sensitive communication, privacy/HIPAA, infection control, and safe handling of venous access devices.

Traps

  • Confusing acute with late effects, or attributing every symptom to radiation (rule out infection, progression, drug toxicity).
  • Believing a patient must not shower or that marks are permanent tattoos when they are not.
  • Assuming the therapist may obtain consent or give prognostic information - escalate instead.
  • Forgetting to document teaching and the patient's response.

Worked example / rule of thumb

A patient with head-and-neck cancer reports a painful, moist, peeling area mid-treatment. Using a grading approach: dry desquamation with itching is mild; moist desquamation is a higher grade requiring gentle cleansing, non-adherent dressing, and notification of the physician/nurse. Always ask "what did you understand?" rather than "do you have questions?" - teach-back exposes gaps.

Safety

Core concepts

Safety questions blend radiation protection with general workplace safety. The organizing principle is ALARA, achieved through time, distance, and shielding. Understand the inverse square law and be able to compute exposure at a new distance. Know the occupational dose limits (effective dose, lens of eye, extremities/skin), the lower limits for the general public and for a declared pregnant worker, and the concept of the dose limit is not a threshold for acceptable exposure. Know area signage, barriers, interlocks, emergency-off buttons, machine and room survey procedures, badge programs (TLD/OSL), and the requirement to survey after any source or patient procedure involving radioactivity.

Non-radiation safety matters too: patient identification with two identifiers, falls precautions, side-rail and bed-height checks, oxygen safety, electrical safety, latex allergy, hazardous-drug handling, and emergency response (fire, code, power failure, source stuck in brachytherapy).

Traps

  • Mixing units: 1 mSv = 100 mrem. Dose-limit questions are usually unit-conversion questions.
  • Applying public limits to occupationally exposed workers, or forgetting the lens and extremity limits differ from whole-body.
  • Forgetting that the patient's own exposure is not subject to a dose limit - only justified and optimized.
  • Assuming a door interlock resets itself after a beam interruption.

Worked example / rule of thumb

A source reads 80 mR/hr at 1 m. At 4 m: exposure falls by the square of the distance ratio, 80 × (1/4)² = 5 mR/hr. Doubling distance quarters exposure; tripling it reduces exposure to one-ninth. When in doubt, increase distance first - it is free and immediate.

Treatment Planning

Core concepts

Planning questions test volume definitions and plan evaluation. Know ICRU concepts: GTV (visible disease), CTV (GTV plus presumed microscopic spread), ITV (CTV plus internal motion), PTV (CTV/ITV plus setup and penumbral margin - a geometric, not biologic, concept), plus OAR and PRV. Understand simulation and immobilization, isocenter placement, beam arrangement, wedges/bolus/compensators, field matching, and when each modality (3D conformal, IMRT/VMAT, SBRT, electrons, protons, brachytherapy) is chosen.

Be able to read a DVH: target coverage, hot spots, dose to OARs, homogeneity and conformity indices, and plan sums. Know fractionation vocabulary (conventional, hypofractionation, hyperfractionation, SBRT) and that prescriptions specify total dose, dose per fraction, and the reference point or volume.

Traps

  • Calling the PTV a biologic margin, or placing microscopic disease in the GTV.
  • Thinking bolus pushes dose deeper - it pulls the high-dose region superficially.
  • Confusing internal motion (ITV) with setup uncertainty (PTV).
  • Reporting a beautiful DVH line without checking which structure was contoured or whether the plan sum is complete.

Worked example / rule of thumb

A common institutional convention is that ≥95% of the PTV receives ≥95% of the prescription while no more than a small volume exceeds 107%. If a plan shows PTV V95 = 88%, the plan fails coverage regardless of how good the OAR sparing looks. Margin rule of thumb (van Herk): PTV margin ≈ 2.5Σ + 0.7σ for systematic (Σ) and random (σ) error.

Radiation Treatment Delivery

Core concepts

Delivery questions test the sequence and verification of treatment. Before beam-on: confirm patient identity and laterality, verify the prescription and plan match the record-and-verify system, confirm accessories (bolus, blocks, wedges, electron cutouts, bite block), perform the time-out, position and immobilize, set gantry/collimator/couch, and verify imaging/IGRT registration. During treatment: maintain continuous audio-visual observation, monitor for motion, and respond to machine faults or patient distress. After: document delivered parameters, MU, and any deviations; report variances.

Know field-size and SSD/SAD relationships, MLC and blocking, electron energy selection and cutout orientation, arc and gated delivery, motion management (DIBH, abdominal compression, tracking), and the requirement to re-verify setup after any interruption or repositioning.

Traps

  • Reversing electron cutout orientation or treating the wrong side - always verify laterality explicitly.
  • Assuming a beam interruption resumes automatically; re-verify position and dose delivered first.
  • Choosing electron energy from the prescribed dose rather than the target depth.
  • Forgetting that with an isocentric technique SSD varies with gantry angle even though the isocenter is fixed.

Worked example / rule of thumb

Electron rule of thumb: the 90% depth (cm) ≈ energy (MeV) ÷ 4, and practical range ≈ energy ÷ 2. A chest-wall electron field needing coverage to 2 cm depth suggests ~8 MeV (8/4 = 2 cm). Confirm with the measured PDD for your machine rather than trusting the shortcut alone.

Dosimetry and Quality Assurance

Core concepts

This domain covers calibration, calculation, and verification. Know that absorbed dose is reported in gray (Gy); 1 Gy = 100 cGy = 100 rad, and 1 cGy = 1 rad. Understand reference calibration with an ion chamber and electrometer, temperature-pressure correction, and the modern calibration protocol (TG-51). Know the QA program structure (e.g., TG-142 categories): daily output constancy, monthly checks, and annual full calibration and mechanical/imaging checks - and that QA frequency and tolerance are machine- and modality-specific.

Calculation content includes MU computation, PDD vs TMR/TPR, collimator and phantom scatter factors, inverse square correction, tray/wedge/block factors, heterogeneity corrections, and independent second checks. IMRT/VMAT patient-specific QA commonly uses gamma analysis (e.g., 3%/2 mm) plus independent dose recalculation. Brachytherapy adds source decay (A = A₀e^(−0.693t/T½)), source strength units, and wipe/survey tests.

Traps

  • Unit slips: confusing Gy with cGy, or rad with rem (dose equivalent).
  • Using PDD at a non-reference SSD without inverse-square correction.
  • Assuming one fixed QA tolerance applies to every machine and technique.
  • Forgetting decay correction for an implanted source over a multi-day course.

Worked example / rule of thumb

MU = prescribed dose ÷ (output × PDD or TMR × Sc × Sp × inverse-square × accessory factors). For decay, an Ir-192 source (T½ ≈ 74 days) falls to roughly half strength in ~2.5 months: after 74 days, activity ≈ 50% of the calibrated value.

ARRT Radiation Therapy cheat sheet

Quick reference

Patient Care and Education

  • Radiation dermatitis timeline: faint erythema at 10–15 fractions (~20–30 Gy), dry desquamation near 30–40 Gy, moist desquamation typically above 40 Gy once basal cells are depleted.

  • Alopecia begins 2–3 weeks after the first 2 Gy fraction; hair regrows 2–3 months after treatment ends, but scalp doses above ~45–50 Gy may cause permanent loss.

  • Oral mucositis appears 10–14 days after the start of radiation, peaks at 2–3 weeks, and resolves 2–4 weeks after completion unless dose exceeds mucosal tolerance.

  • Fatigue is the most common side effect of radiation therapy; it typically begins within the first 1–2 weeks and may persist 4–6 weeks or longer after treatment ends.

  • Informed consent must document diagnosis, treatment intent (curative vs palliative), technique, expected benefits, material risks, alternatives including no treatment, and the right to withdraw.

  • Two patient identifiers (name plus date of birth or medical record number) are verified before every simulation and treatment per National Patient Safety Goal requirements.

  • Weekly weights are recorded during treatment; loss greater than 5% of pre-treatment weight triggers dietitian referral and consideration of enteral supplementation.

  • Skin care rule: cleanse with lukewarm water and mild soap, pat dry, and avoid heat, sun, friction, adhesive tape, and deodorant on the treated field unless institutional protocol states otherwise.

Quick reference

Safety

  • NCRP Report 116 annual occupational limits: 50 mSv (5 rem) total effective dose, 150 mSv (15 rem) to the lens of the eye, 500 mSv (50 rem) to skin and extremities.

  • Public dose limit from a licensed facility is 1 mSv (100 mrem) per year and 0.02 mSv (2 mrem) in any single hour.

  • Inverse square law: I1/I2 = (d2/d1)²; doubling the distance from a point source reduces exposure to one quarter.

  • Half-value layer HVL = 0.693/μ, and transmitted intensity follows I = I0e^(−μx); ten half-value layers reduce intensity by a factor of about 1000.

  • Posting thresholds measured at 30 cm from the source: 'Caution: Radiation Area' above 0.05 mSv/h (5 mrem/h); 'High Radiation Area' above 1 mSv/h (100 mrem/h).

  • ALARA controls ranked as time, distance, and shielding; distance is the most practical and effective single control for staff exposure.

  • Linac safety interlocks: door interlock terminates beam on entry, and beam-off/beam-on indicators plus audio-visual alarms are checked daily before patient treatment.

  • A patient with a permanent brachytherapy implant may be released only if the calculated dose to any other person is unlikely to exceed 5 mSv (500 mrem) and written radiation-safety instructions are provided.

Quick reference

Treatment Planning

  • Volume chain: GTV (visible tumor) → CTV (GTV plus microscopic disease) → ITV (CTV plus internal motion) → PTV (CTV or ITV plus setup margin), with organs at risk contoured separately.

  • Van Herk margin recipe: PTV margin = 2.5Σ + 0.7σ, where Σ is the systematic error SD and σ the random error SD, giving at least 95% CTV coverage in 90% of patients.

  • QUANTEC central nervous system constraints: spinal cord maximum ≤50 Gy (45 Gy to full cord cross-section), brainstem ≤54 Gy, optic chiasm/nerves ≤50 Gy, lens ≤6–10 Gy.

  • Parotid constraint: mean dose below 26 Gy, or at least one gland below 20 Gy, reduces the incidence of grade 2 or worse xerostomia.

  • Thoracic constraints: lung V20 ≤30–35% and mean lung dose ≤20 Gy; heart V25 ≤10% and mean heart dose as low as reasonably achievable in breast planning.

  • Electron beam rule of thumb: practical range Rp ≈ E/2 cm in water and the 90% depth dose lies near E/3 to E/4 cm, so energy selection is based on target depth.

  • Equivalent square field size S = 2ab/(a+b); it is used to look up PDD, TMR, Sc, and Sp for rectangular fields.

  • ICRU-83 reporting: prescribe to the median dose (D50%), report near-maximum D2% and near-minimum D98%, and keep PTV coverage at 95% of prescription in 95% of the volume.

  • CT simulation practice: 2–3 mm slice thickness, reproducible immobilization, and 4DCT or respiratory gating when target motion exceeds about 1 cm.

Quick reference

Radiation Treatment Delivery

  • TG-142 output constancy tolerances: ±3% daily, ±2% monthly, and ±1% annual relative to the baseline calibration.

  • Daily mechanical checks: lasers and optical distance indicator within ±2 mm, collimator and gantry angle indicators within ±1 degree.

  • Winston-Lutz test verifies coincidence of radiation field center and mechanical isocenter to within 1 mm at multiple gantry, collimator, and couch positions for SRS/SBRT programs.

  • SBRT delivery requires image-guided localization within 1 mm, 6D couch correction before each fraction, and motion management (compression or gating) when excursion exceeds 5 mm.

  • VMAT delivers dose during continuous gantry rotation by simultaneously modulating multileaf collimator positions, dose rate, and gantry speed across one or more arcs.

  • Half-beam blocking places the collimated field edge at the machine midline so that adjacent fields (for example cranial and spinal fields) match without divergence overlap at depth.

  • Total body irradiation uses extended SSD (typically 300–400 cm), AP/PA parallel-opposed fields, 5–10 cGy/min dose rate to limit pulmonary toxicity, and lung compensators; 12 Gy in 6 fractions is a common regimen.

  • Deep inspiration breath hold for left breast irradiation increases heart-to-chest-wall distance and lowers mean cardiac dose compared with free breathing.

  • Orthogonal kV or CBCT verification tolerance is typically 2–3 mm for bony anatomy and about 2 mm for soft-tissue targets before treatment.

Quick reference

Dosimetry and Quality Assurance

  • TG-51 photon reference conditions: 10 cm depth in water, 100 cm SSD or SAD, 10 × 10 cm field, 0.6 cc Farmer chamber; Dw = M·N_Dw·P_ion·P_tp·P_elec·P_pol.

  • Isocentric MU calculation: MU = prescribed dose ÷ (calibrated output × TMR(d,r) × Sc(rc) × Sp(r) × wedge/tray factor × inverse-square correction).

  • Converting percent depth dose to TMR: TMR(d,r) = (%DD/100) × ((SSD+d)/(SSD+dmax))² × (Sp(dmax)/Sp(d)).

  • Gamma index combines dose difference and distance-to-agreement; 3%/3 mm with at least 95% of points passing is the standard IMRT QA threshold, and 2%/2 mm is often used for SBRT.

  • Isotope data: I-125 half-life 59.4 days with ~28 keV average photons; Pd-103 17 days at ~21 keV; Cs-131 9.7 days; Ir-192 73.8 days at ~380 keV average.

  • TG-43 brachytherapy formalism: D(r,θ) = Sk·Λ·[G(r,θ)/G(r0,θ0)]·g(r)·F(r,θ), with Λ the dose-rate constant, g the radial function, and F the anisotropy function.

  • In-vivo diode dosimetry action level is commonly ±5% between measured and calculated dose at the measurement point, prompting investigation when exceeded.

  • Chamber correction factors applied during calibration: P_ion for recombination, P_tp for temperature and pressure, P_pol for polarity, and P_elec for electrometer calibration.

ARRT Radiation Therapy key terms

Informed consent

The process of explaining a proposed treatment's purpose, risks, benefits, and alternatives so the patient can voluntarily agree to proceed, documented before therapy begins.

Related: Teach-back method
Radiation dermatitis

Skin reaction from radiation exposure ranging from redness and dryness to moist desquamation and ulceration in treated areas, managed with gentle cleansing, moisturizers, and avoidance of friction.

Related: Oral mucositis, Supportive care
Oral mucositis

Painful inflammation and ulceration of the mouth and throat lining caused by radiation to the head and neck, which can impair eating and speaking and requires oral care and pain control.

Related: Radiation dermatitis, Supportive care
Cancer-related fatigue

A persistent, distressing sense of tiredness related to cancer or its treatment that is not relieved by rest and interferes with daily activities, managed with activity, sleep hygiene, and energy conservation.

Related: Supportive care
Teach-back method

A patient-education technique in which the patient restates information or demonstrates a skill in their own words, letting the therapist confirm understanding and correct misunderstandings.

Related: Informed consent
Supportive care

Services and interventions that prevent or relieve treatment side effects and improve comfort and quality of life, such as nutrition support, pain management, skin care, and psychosocial counseling.

Related: Radiation dermatitis, Cancer-related fatigue
ALARA

A radiation-protection principle meaning doses are kept As Low As Reasonably Achievable, considering economic and social factors, through shielding, good technique, and minimizing exposure time.

Related: Time, distance, shielding, Personnel dosimeter
Time, distance, shielding

The three basic ways to reduce radiation exposure: limit time spent near a source, increase distance from it, and place appropriate absorbing material between the person and the source.

Related: ALARA
Personnel dosimeter

A badge or ring worn by radiation workers to record cumulative occupational dose, typically using optically stimulated luminescence or thermoluminescent technology, read periodically by a monitoring service.

Related: Occupational dose limit, ALARA
Occupational dose limit

The maximum permitted annual radiation dose for a radiation worker, set by regulators at 50 mSv (5 rem) to the whole body, intended to keep risk acceptably low.

Related: Personnel dosimeter, Fetal dose
Fetal dose

The radiation dose received by a developing fetus; a declared pregnancy triggers dose estimates, extra shielding, and work-practice changes to keep exposure below regulatory limits.

Related: Occupational dose limit, ALARA
Door interlock

A safety device that stops or prevents beam-on whenever the treatment room door is open, protecting staff and others from unintended exposure.

Related: Emergency-off switch
Emergency-off switch

A clearly marked button inside the treatment room that immediately terminates beam-on or machine motion so the patient can be reached in an emergency.

Related: Door interlock
CT simulation

A CT scan performed in the treatment position with immobilization and reference marks, producing images used to define anatomy and design the radiation plan.

Related: Isocenter, Four-dimensional CT (4DCT)
Isocenter

The point in space where the rotation axes of the gantry, collimator, and couch intersect; treatment fields are usually planned to align with it.

Related: Planning target volume (PTV)
Gross tumor volume (GTV)

The visible or palpable extent of tumor shown by imaging or clinical examination, defined before adding margins for microscopic spread or setup uncertainty.

Related: Planning target volume (PTV)
Planning target volume (PTV)

The clinical target volume plus margins that account for organ motion and daily setup variation, ensuring the prescribed dose actually reaches the intended tissue.

Related: Gross tumor volume (GTV), Organ at risk (OAR)
Organ at risk (OAR)

Normal tissue or a critical structure near the target whose radiation tolerance may limit the dose that can be safely delivered.

Related: Planning target volume (PTV), Dose-volume histogram (DVH)
Beam's eye view

A planning display showing anatomy as seen along the beam's central axis, used to choose beam angles and field shapes that avoid critical structures.

Related: Organ at risk (OAR), Isocenter
Bolus

Tissue-equivalent material placed on the skin to build up dose in superficial tissue, used when the target lies near the surface or the beam would otherwise spare it.

Related: Percentage depth dose (PDD), Electron cutout
Intensity-modulated radiation therapy (IMRT)

A planning and delivery technique using non-uniform beam intensities, usually shaped by multileaf collimators, to wrap dose around the target while sparing nearby normal tissue.

Related: Dose-volume histogram (DVH), Gamma index
Four-dimensional CT (4DCT)

A CT scan that records images at multiple phases of the breathing cycle, letting planners see how tumors and organs move with respiration.

Related: Respiratory gating, CT simulation
Monitor unit (MU)

A machine-specific unit of delivered output for a linear accelerator; the prescribed dose is converted to monitor units using depth-dose, output, and geometry data.

Related: Percentage depth dose (PDD), TG-51 calibration
Electronic portal imaging device (EPID)

An imaging panel mounted opposite the beam source that captures images of the patient in the treatment position, used to verify field placement and anatomy.

Related: Cone-beam CT (CBCT), Treatment time-out
Cone-beam CT (CBCT)

An imaging system on the treatment machine that produces three-dimensional volumetric images at the treatment position, used for image-guided verification and repositioning before delivery.

Related: Electronic portal imaging device (EPID), Treatment time-out
Respiratory gating

A motion-management method in which the beam is delivered only during a selected portion of the breathing cycle, reducing the effect of tumor motion on the dose.

Related: Four-dimensional CT (4DCT)
High-dose-rate (HDR) afterloading

A brachytherapy technique in which a radioactive source is remotely driven into an implanted applicator after staff leave the room, delivering a high dose rate over a short time.

Related: Time, distance, shielding
Wedge

A shaped beam attenuator placed in the beam path to tilt the dose distribution across a field, compensating for missing tissue or producing a more uniform dose.

Related: Bolus
Treatment time-out

A brief pause before delivery in which staff confirm the patient's identity, treatment site, plan parameters, and imaging results all match the prescription.

Related: Electronic portal imaging device (EPID), Cone-beam CT (CBCT)
Electron cutout

A shaped piece of low-melting-point alloy placed in the electron applicator to define the treatment field and shield tissue outside the target.

Related: Bolus
Absorbed dose

The amount of radiation energy deposited per unit mass of tissue, expressed in gray, where one gray equals one joule per kilogram.

Related: Percentage depth dose (PDD), Ionization chamber
Percentage depth dose (PDD)

The dose at a given depth along the central axis, expressed as a percentage of the maximum dose, used to calculate dose at depth for a given field size.

Related: Inverse square law, Monitor unit (MU)
Inverse square law

The rule that radiation intensity from a point source decreases with the square of the distance, so doubling the distance reduces intensity to one quarter.

Related: Percentage depth dose (PDD)
TG-51 calibration

A widely used protocol for calibrating treatment machine output with an ionization chamber in water, converting measured charge into absorbed dose under reference conditions.

Related: Ionization chamber, Daily quality assurance (QA)
Daily quality assurance (QA)

Tests performed at the start of each treatment day, such as output constancy, laser alignment, and safety checks, to confirm the machine works within tolerance.

Related: TG-51 calibration
Ionization chamber

A detector in which radiation ionizes gas and the resulting charge is collected to measure dose, commonly used for machine calibration and quality assurance.

Related: TG-51 calibration, Personnel dosimeter
Dose-volume histogram (DVH)

A graph summarizing how much volume of a structure receives a given dose, used to evaluate target coverage and normal-tissue exposure.

Related: Organ at risk (OAR), Intensity-modulated radiation therapy (IMRT)
Gamma index

A metric comparing two dose distributions using both dose difference and distance-to-agreement, with a pass rate showing how closely a measured plan matches the calculated plan.

Related: Dose-volume histogram (DVH), Intensity-modulated radiation therapy (IMRT)

ARRT Radiation Therapy study plan

8 weeks · About 6 hours per week

Week 1

Treatment Planning

  • Map the simulation-to-treatment workflow and label the decision points at each step

  • Differentiate GTV, CTV, ITV, PTV, and treated volume, and state the margin rationale behind each

  • Explain how immobilization device choice and patient positioning influence setup reproducibility and planning margins

  • Compare CT, MRI, PET, and 4DCT for simulation and identify what each contributes to target delineation

Your checkpoint

One-page annotated workflow diagram plus a written 10-item ICRU volume-definition self-quiz scored at 90% or better

Week 2

Treatment Planning & Dosimetry and Quality Assurance

  • Interpret a cumulative DVH to compare competing plans against target coverage and organ-at-risk constraints

  • Apply the concepts of dose tolerance, complication probability, and dose-volume constraints to rank plan acceptability

  • Describe photon beam characteristics (penumbra, depth dose, field size effects) and how they shape plan quality

  • Identify when electron, proton, or brachytherapy approaches are preferred over external photon beams

Your checkpoint

Two written plan-evaluation case write-ups (head-and-neck and prostate) with a defendable accept/reject recommendation for each

Week 3

Dosimetry and Quality Assurance

  • Sequence the steps of an absorbed-dose calibration and state which reference conditions must be verified

  • Outline a periodic linear accelerator quality-assurance schedule and match each test to the failure mode it detects

  • Describe treatment planning system commissioning and validation steps, including data acquisition and independent dose verification

  • Explain brachytherapy source strength verification and the checks performed before each implant

Your checkpoint

A completed QA responsibility matrix (test, frequency, tolerance, action level) covering machine, TPS, and brachy sources

Week 4

Dosimetry and Quality Assurance & Safety

  • Apply ALARA reasoning to time, distance, and shielding decisions in a simulated clinical scenario

  • Define occupational and public dose limits and identify which apply to a pregnant technologist

  • Describe the elements of a radiation safety program, including area monitoring and recordkeeping requirements

  • Distinguish a recordable event from a reportable medical event and state the required response sequence

Your checkpoint

Timed 25-question mixed dosimetry-and-safety practice set, with every missed item rewritten as a corrected study note

Week 5

Safety

  • Perform shielding and workload calculations for a treatment barrier using given occupancy and use factors

  • Explain emergency procedures for source malfunction, equipment failure, and patient medical emergencies during treatment

  • Identify infection-control, patient-identification, and site-verification practices that prevent wrong-site or wrong-dose treatment

  • Compare regulatory frameworks governing machine, sealed-source, and patient-release requirements

Your checkpoint

A written emergency-response drill script for three distinct failure scenarios, each with role assignments and time-sequenced actions

Week 6

Radiation Treatment Delivery

  • Differentiate IMRT, VMAT, SBRT, and conventional delivery in terms of planning intent, delivery mechanics, and verification needs

  • Describe image-guidance verification for each treatment site and state the corrective action for a setup deviation beyond tolerance

  • Outline the pre-treatment time-out and chart-check process and list the documents verified at each step

  • Explain delivery considerations for electron therapy and brachytherapy, including applicator positioning and source dwell verification

Your checkpoint

A delivery-technique comparison table plus a complete pre-treatment checklist written from memory and cross-checked against reference notes

Week 7

Patient Care and Education

  • Map the acute and late effects of treatment for each major site to their expected onset, management, and reporting threshold

  • Design patient teaching talking points for skin care, nutrition, fatigue, and sexuality concerns in plain language

  • Identify when to escalate a patient concern to the physician or nurse and state the appropriate documentation

  • Explain consent, psychosocial support, and cultural or literacy considerations that shape patient education

Your checkpoint

Three patient-education scripts (skin reaction, fatigue, and dietary change) written at a sixth-grade reading level and reviewed for missing escalation criteria

Week 8

Patient Care and Education & Safety & Treatment Planning & Radiation Treatment Delivery & Dosimetry and Quality Assurance

  • Complete two full-length timed practice exams under test-day conditions

  • Categorize every missed item by domain and by error type (knowledge gap, misread, or calculation slip)

  • Re-drill the two weakest domains using targeted mini-sets until accuracy exceeds 85%

  • Rehearse the highest-yield formulas and reference values until they are reproduced accurately from memory

Your checkpoint

A written score-trend log across all practice exams with a short remediation plan naming the specific subtopics to review in the final days

Milestones

Week 4: Score 75% or higher on a 40-question mixed set drawn from Treatment Planning and Dosimetry/QA; if below, reallocate week 5 hours toward the weaker domain

Week 6: Reproduce the delivery and verification checklist with no omissions and correctly handle all setup-deviation scenarios in a verbal walkthrough

Week 8: Achieve 80% or higher on both full-length practice exams, with no single domain below 70%

ARRT Radiation Therapy exam day

Your checklist

Primary photo ID with signature

A government-issued photo ID that also bears your signature (driver's license or passport are typical). The name on the ID should match the name on your ARRT record; if your legal name has changed, contact ARRT before test day rather than trying to resolve it at the center.

Second form of identification

Testing centers generally require a second ID that shows your signature (for example a credit card or another government-issued document). Confirm the exact accepted forms with your testing provider before you travel.

Appointment confirmation / authorization to test

Bring the confirmation showing your appointment time, test center, and any candidate or eligibility number. Having it on paper avoids relying on your phone, which will not be allowed in the testing room.

Your ARRT eligibility status verified in advance

Log in to your ARRT account a few days ahead and confirm your exam window is open and your authorization is active. Resolving a paperwork problem 48 hours out is far easier than at the check-in desk.

Testing center address, parking, and route

Do a dry run or at least map the route and parking options. Testing centers are often inside office parks or shared buildings and can be hard to find on a first visit.

Plan to arrive early

Arriving roughly 30 minutes before your appointment allows time for check-in, ID verification, and a locker. Confirm your provider's late-arrival policy in advance - candidates who arrive after the cutoff may not be admitted.

Leave prohibited items at home or in the car

Phones, smartwatches, fitness trackers, notes, and study materials are not permitted in the testing room. Most centers provide a small locker, but minimizing what you carry simplifies check-in.

Comfortable, layered clothing

Testing rooms are often cold and you will be seated for a long stretch. Dress in layers and avoid items with pockets or accessories that slow security screening.

Confirm the calculator and reference-material policy

Ask your provider or check the ARRT candidate handbook ahead of time about whether an on-screen calculator or any reference material is available, and what is prohibited. Do not assume a personal calculator is allowed.

Snack, water, and a light meal for afterward

Keep these in your locker or car rather than carrying them into the room. A long computer-based exam is easier to manage if you are not hungry or dehydrated.

A one-page summary of your weakest topics

Use it only in the waiting area before check-in, then put it away. Its purpose is a last confidence pass on high-yield facts, not new learning.

Backup transportation plan

Identify a second way to reach the center in case of traffic, transit delays, or a vehicle problem. A missed appointment can mean a rescheduling fee.

Plan the day

Final 72 hours

Stop expanding your content list. Spend the remaining time on timed practice sets and a focused review of two or three weak topic areas from your radiation therapy content outline - treatment planning and dose calculation, treatment delivery and setup, safety and quality management, or patient care and education. Confirm your appointment details, verify your ID has not expired, and start shifting your sleep schedule toward the time you will need to wake on test day.

Final 72 hours - practical logistics

Re-check the test center address and estimated travel time, confirm parking, and print or save your appointment confirmation. Read the ARRT candidate handbook section on exam-day procedures so there are no surprises about ID, prohibited items, or scoring.

24 hours before

Keep review light: skim summaries, formulas, and positioning or safety checklists rather than working new practice questions until late. Pack your bag with IDs, confirmation, layers, and a snack. Set two alarms, plan to eat a normal dinner, and prioritize 7-8 hours of sleep over one more study session.

Morning of the exam

Eat a normal breakfast or meal, hydrate, and give yourself a buffer beyond your estimated travel time. Glance at your one-page summary only in the waiting area. At check-in, present your IDs, store personal items in the locker, and take a few slow breaths before the tutorial begins.

During the test - first pass

Read every question stem completely before looking at the options, and watch for qualifiers such as 'except,' 'first,' or 'best.' Answer the straightforward items first and flag anything that requires extended calculation or recall, then return to flagged items.

During the test - pacing and breaks

Track your progress against the number of items remaining and the time on the clock. If you fall behind, guess on an item and move on rather than losing several minutes to one question. Raise your hand if you need to leave the room; unscheduled breaks are generally allowed but the clock keeps running, so keep them short.

During the test - final review

Use remaining time on flagged items, confirming you have answered every question with no blanks. Only change an answer if you can point to a specific reason the original choice was wrong. Submit when your review is done rather than second-guessing at length.

After the exam

Follow the center's check-out procedure and retrieve your belongings. Ask the staff or check your ARRT account about how and when official results are released, since timing of preliminary versus official reporting varies.

Rules to check

  • Bring two forms of identification, at least one of which is a government-issued photo ID with your signature. The name must match your ARRT record; if it does not because of a legal name change, contact ARRT before the exam date to correct it.

  • Personal items - phones, smartwatches, wearable devices, notes, and study material - are not allowed in the testing room. Using unauthorized materials or communicating with others during the exam can invalidate your score, so clarify the exact policy with the testing provider beforehand.

  • Arrive before your scheduled appointment time; many centers deny admission to candidates who arrive after the posted cutoff. Confirm the specific late-arrival and rescheduling policy with the provider when you book.

  • Unscheduled breaks are typically permitted, but the exam clock continues to run and you may be subject to a security check when re-entering the room. Confirm the break policy with the provider on arrival.

  • Scores are reported on a scaled basis with a minimum passing standard set by ARRT; do not expect the reported score to equal a simple percentage of questions answered correctly, and note that some items may be unscored pilot questions. Confirm the current passing standard and score-report timing in the ARRT candidate handbook or with ARRT directly.

  • If you do not pass, ARRT imposes waiting periods and limits on retakes. Confirm the current retake rules and fees with ARRT before assuming a timeline for your next attempt.

  • Follow all instructions from testing center staff, including emptying pockets, removing outerwear if asked, and accepting a seat assignment. Compliance issues can be documented and reported to the credentialing body.

  • Direct any question about eligibility, accommodations, or exam content that is not resolved by the candidate handbook to ARRT before test day; center staff administer the exam but cannot change eligibility or scoring decisions.

ARRT Radiation Therapy FAQ

How many ARRT Radiation Therapy practice questions are available?

The practice set has 200 ARRT Radiation Therapy questions. Each one includes the choices, the correct answer, and an explanation, and the set is free to read with no signup.

How many ARRT Radiation Therapy flashcards are available?

The flashcard set has 32 ARRT Radiation Therapy cards. Each card shows the term and its definition.

Which topics does the ARRT Radiation Therapy study material cover?

The ARRT Radiation Therapy study material has 5 sections, including Patient Care and Education, Safety, and Treatment Planning.

What format facts does the catalog list for the ARRT Radiation Therapy exam?

The catalog lists these item types: multiple choice for the ARRT Radiation Therapy exam.