ARRT Nuclear Medicine Practice Test

ARRT Nuclear Medicine Technology (NMT) Examination

ARRT Nuclear Medicine overview

  • 200 practice questions
  • 32 flashcards
  • 5 study guide topics
  • 39 key terms

What you'll study

  • Diagnostic Procedures / Clinical Applications20%
  • Radiopharmacy and Radiopharmaceuticals20%
  • Instrumentation and Image Production (including PET and CT)20%
  • Radiation Safety and Protection20%
  • Patient Care and Quality Control20%

Nuclear Medicine Technology is one of ARRT's primary credentials, and certification and registration in this discipline recognizes individuals who are qualified to perform the role of a nuclear medicine technologist. The work is a sophisticated area of health care that helps physicians diagnose and evaluate serious conditions such as cancer and heart disease: technologists prepare and inject radiopharmaceutical agents into patients, then use a scanner or camera to capture diagnostic images, and they support nervous patients by explaining what to expect.

Earning the credential means meeting ARRT's initial requirements in education, ethics, and examination, and applying through the primary eligibility pathway. The exam is built from ARRT's published Examination Content Specifications, which have shifted substantially since 2000, largely because of the increasing prominence of positron emission tomography (PET) and CT and the constantly changing availability of radiopharmaceutical compounds. In January 2020, ARRT began using a new cut score for the NMT examination, still reported as a scaled score of 75, although more correct items are now required to reach it.

Preparation should be document-driven: read the Examination Content Specifications and Task Inventory, confirm which published version applies to your exam date, and pair that outline with supervised clinical experience in radiopharmacy, instrumentation, radiation safety, and patient care.

Common mistakes

Answers procedure questions by matching a radiopharmaceutical name to a memorized scan title, even when the stem describes a different mechanism, such as choosing sulfur colloid for a GI bleed because both were studied together.

Procedure lists are memorized as isolated facts rather than as mechanism-to-indication pairs, and exam stems use clinical wording that does not repeat the scan name.

What to do instead

Build and rehearse a two-column table of radiopharmaceutical and localization mechanism versus clinical indication and typical timing; for every practice stem, state the mechanism before selecting the study.

Uses a fixed standard imaging time for every study instead of adjusting for radiopharmaceutical kinetics and patient factors, such as failing to delay hepatobiliary imaging when the gallbladder is not seen or mistiming a renal scan after diuretic administration.

Protocol times are learned as numbers rather than as consequences of uptake and clearance, while question stems add patient-specific variables.

What to do instead

For each protocol, write the physiologic rationale for the start time and any delayed views, then practice decision rules for when to delay imaging or administer an adjunct.

Selects or prepares a radiopharmaceutical without checking formulation and patient-specific constraints, such as MAA particle number in pulmonary hypertension or pediatric dosing, oxidant levels in pertechnetate, or aluminum breakthrough in generator eluate.

Attention focuses on the isotope name and overlooks formulation limits and quality attributes that are tested in scenario form.

What to do instead

Use a pre-administration checklist covering prescribed activity, particle count and volume, radionuclidic and radiochemical purity, generator eluate limits, and patient-specific contraindications.

Calculates administered or remaining activity without consistent decay correction and unit conversion, such as using calibration-time activity as the injected activity or mixing mCi and MBq in the same equation.

Half-lives are memorized without the exponential decay setup, and time units or activity units create traps.

What to do instead

Write A(t) = A0 times e to the minus 0.693 t over T1/2 with t and T1/2 in the same unit; convert all activities to one unit before calculating and check the result with a rough half-life estimate.

Pairs an isotope with the wrong collimator or energy window out of habit, such as selecting a low-energy collimator for I-131 or a 140-keV window for F-18.

Collimator and window facts are memorized separately from isotope photon energy, but exam items combine them.

What to do instead

Create an isotope card listing principal photon energy, required collimator type, and window setting; practice rejecting options that mismatch energy or septal thickness.

Interprets PET/CT images or SUV values without accounting for attenuation correction, blood glucose, uptake time, or lean-body-mass normalization.

SUV is treated as a fixed tumor marker rather than a semi-quantitative index affected by acquisition and patient variables.

What to do instead

For each PET question, list the assumptions behind SUV and check whether the stem changes glucose, uptake time, reconstruction, or attenuation correction; compare lesions with background rather than relying only on absolute cutoffs.

Applies radiation dose limits to the wrong group or uses inverse-square and shielding formulas without converting units or distinguishing exposure rate from accumulated dose.

Limits, units, and geometry are learned as separate facts, while exam stems combine them in one calculation.

What to do instead

Make a one-page reference of dose limits by category and practice calculations with dimensional analysis, separating mSv, mGy, and mR and separating activity from exposure rate.

Responds to a radioactive spill by decontaminating immediately without first securing the area, surveying, using appropriate PPE, or segregating waste, or uses a dose-rate meter to quantify removable contamination.

Spill response is memorized as a sequence of actions rather than as a survey-and-containment decision tree, and survey instruments are confused.

What to do instead

Rehearse a spill algorithm: warn and secure, survey with the appropriate detector, contain, decontaminate from low to high, re-survey, and document; distinguish survey-meter readings from wipe-test contamination.

Mixes up QC test frequency and acceptance limits, such as daily energy peaking versus weekly uniformity, dose calibrator constancy versus linearity, or when a chi-square test applies.

QC tables are memorized by rows without anchoring each test to its purpose, instrument, and corrective action.

What to do instead

Build a QC matrix by instrument with columns for test, frequency, limit, and action if failed; group tests by purpose such as accuracy, constancy, linearity, geometry, resolution, and sensitivity.

Skips or rushes patient screening and preparation, such as not checking pregnancy or breastfeeding status, renal function, recent contrast, fasting or glucose, or medications that block uptake.

Attention stays on the imaging protocol and treats screening as paperwork, while exam stems hide contraindications in the patient history.

What to do instead

Use a structured pre-scan checklist and practice history-hunt questions by identifying the one medication, laboratory value, or condition that changes timing, dose, or whether to proceed.

Exam requirements can change. Confirm current details with the exam provider.

ARRT Nuclear Medicine practice

200 questions. Each one lists the choices, the correct answer, and an explanation. With JavaScript, this list opens one question at a time. The checker at the top of this page saves progress in this browser when it is available.

  1. Question 1Diagnostic Procedures / Clinical Applications

    Which radiopharmaceutical is used for routine skeletal scintigraphy?

    1. Tc-99m mebrofenin
    2. Tc-99m sulfur colloid
    3. Tc-99m medronate (MDP) Correct answer.
    4. Tc-99m pentetate (DTPA)

    Explanation

    MDP is a diphosphonate that adsorbs onto the hydroxyapatite crystal surface of bone, with roughly half of the injected dose localizing to the skeleton. The remainder is cleared by the kidneys, which provides the bone-to-soft-tissue contrast needed for imaging.

  2. Question 2Diagnostic Procedures / Clinical Applications

    On a hepatobiliary (HIDA) scan, continued nonvisualization of the gallbladder at 4 hours after injection is most consistent with:

    1. Common bile duct obstruction
    2. Diffuse hepatocellular dysfunction
    3. Acute cholecystitis Correct answer.
    4. Chronic acalculous cholecystitis

    Explanation

    When tracer reaches the bowel but the gallbladder never fills, the cystic duct is obstructed, which is the hallmark of acute cholecystitis. Delayed imaging to 4 hours, sometimes with morphine augmentation, raises specificity for that diagnosis.

  3. Question 3Diagnostic Procedures / Clinical Applications

    A mismatched perfusion defect on a V/Q lung scan, with reduced perfusion but preserved ventilation, is the classic scintigraphic sign of:

    1. Atelectasis
    2. Pulmonary embolism Correct answer.
    3. Pneumonia
    4. Chronic obstructive pulmonary disease

    Explanation

    Airway disease reduces both ventilation and perfusion to the same region, so defects appear matched. An embolus occludes the vessel and abolishes perfusion while ventilation to that segment remains intact, producing the mismatch.

  4. Question 4Diagnostic Procedures / Clinical Applications

    Tc-99m pertechnetate is the radiopharmaceutical of choice for detecting a Meckel diverticulum because it:

    1. Accumulates in the diverticulum's fecal contents
    2. Is trapped by the diverticulum's lymphoid tissue
    3. Is taken up by ectopic gastric mucosa Correct answer.
    4. Binds to ectopic pancreatic tissue

    Explanation

    Pertechnetate is actively trapped by gastric mucosa, so a diverticulum containing ectopic gastric mucosa shows a focal area of increasing activity, usually in the right lower quadrant. Pretreatment with an H2 blocker or glucagon can improve target-to-background ratio.

  5. Question 5Diagnostic Procedures / Clinical Applications

    For a thyroid uptake measurement, Tc-99m pertechnetate differs from radioiodine in that pertechnetate is:

    1. Trapped but not organified Correct answer.
    2. Organified but not trapped
    3. Bound to thyroglobulin in colloid
    4. Neither trapped nor organified

    Explanation

    Pertechnetate is handled by the sodium-iodide symporter but is not a substrate for thyroid peroxidase, so it cannot be incorporated into thyroglobulin. This makes it suitable for imaging and trapping measurements but not for assessing organification or for therapy.

  6. Question 6Diagnostic Procedures / Clinical Applications

    Which radiopharmaceutical provides the best assessment of regional renal cortical function and scarring?

    1. Tc-99m pertechnetate
    2. Tc-99m MAG3
    3. Tc-99m DTPA
    4. Tc-99m DMSA Correct answer.

    Explanation

    DMSA binds to proximal tubular cells and is retained in the cortex, yielding high cortical-to-background images that depict functioning cortex and scars. MAG3 and DTPA are rapidly cleared agents used for dynamic flow and clearance studies.

  7. Question 7Diagnostic Procedures / Clinical Applications

    The uptake of 18F-FDG in a tumor reflects:

    1. Cell membrane integrity
    2. Regional blood flow
    3. Glucose metabolism Correct answer.
    4. DNA synthesis

    Explanation

    FDG is a glucose analog that is phosphorylated by hexokinase but not further metabolized, so it is trapped intracellularly in proportion to glycolytic rate. Malignant cells typically overexpress glucose transporters and hexokinase, giving high uptake.

  8. Question 8Diagnostic Procedures / Clinical Applications

    For sentinel lymph node mapping in breast cancer, the radiotracer is typically injected:

    1. Into the tumor bed
    2. Intradermally around the areola Correct answer.
    3. Intravenously
    4. Into the subclavian artery

    Explanation

    Intradermal or periareolar injection enters the rich dermal lymphatic plexus that drains the breast, allowing the first draining node to be identified quickly with a gamma probe. The node is then localized surgically and checked for radioactivity before excision.

  9. Question 9Diagnostic Procedures / Clinical Applications

    A whole-body bone scan shows intensely increased, diffuse skeletal uptake with faint or absent renal and soft-tissue activity. This superscan appearance is most often due to:

    1. Recent treatment with colony-stimulating factors
    2. Widespread skeletal metastases Correct answer.
    3. Hyperparathyroidism
    4. Severe renal failure

    Explanation

    When the skeleton is diffusely laden with metastatic disease, most of the tracer is extracted before it can be excreted, so the kidneys appear faint. Prostate and breast carcinoma are the classic causes of this pattern.

  10. Question 10Diagnostic Procedures / Clinical Applications

    Which patient preparation is required before a dipyridamole myocardial perfusion study?

    1. Avoiding caffeine for 12-24 hours Correct answer.
    2. Fasting for 12 hours
    3. Stopping beta-blockers for 48 hours
    4. Premedication with atropine

    Explanation

    Caffeine and theophylline are adenosine receptor antagonists that block vasodilator-induced hyperemia and can produce a false-negative study. They must be withheld, whereas beta-blockers and food intake do not blunt a vasodilator stress response.

  11. Question 11Diagnostic Procedures / Clinical Applications

    In a captopril renogram performed for suspected renovascular hypertension, a positive study is characterized by:

    1. Rapid washout of tracer from the affected kidney
    2. Deterioration of the renogram curve in the stenotic kidney Correct answer.
    3. Symmetrical time-to-peak in both kidneys
    4. Improved tracer uptake in the affected kidney

    Explanation

    ACE inhibition lowers angiotensin II-mediated efferent arteriolar tone, so in a kidney with a tight renal artery stenosis the glomerular filtration rate falls and the renogram deteriorates compared with baseline. A normal study shows no change or symmetric curves.

  12. Question 12Diagnostic Procedures / Clinical Applications

    On a furosemide renogram, which finding indicates true obstruction rather than a dilated but unobstructed collecting system?

    1. Tracer half-time greater than 20 minutes Correct answer.
    2. An initial uptake phase in the cortex
    3. Prompt response to furosemide
    4. Tracer accumulation in the bladder

    Explanation

    In a dilated but unobstructed system, furosemide-induced diuresis washes tracer out with a half-time under about 10 to 15 minutes. A prolonged half-time beyond 20 minutes indicates mechanical obstruction, with values in between considered equivocal.

  13. Question 13Diagnostic Procedures / Clinical Applications

    Which radiopharmaceutical is preferred for detecting intermittent lower gastrointestinal bleeding because it can be imaged over a prolonged period?

    1. Tc-99m mebrofenin
    2. Tc-99m labeled red blood cells Correct answer.
    3. In-111 pentetreotide
    4. Tc-99m sulfur colloid

    Explanation

    Labeled red blood cells remain within the vascular space with a long biological half-life, allowing repeated imaging for up to 24 hours so that intermittent bleeding can be captured. Sulfur colloid is cleared by the reticuloendothelial system within minutes and limits the imaging window.

  14. Question 14Diagnostic Procedures / Clinical Applications

    On a dual-phase Tc-99m sestamibi parathyroid scan, a parathyroid adenoma typically appears as:

    1. A photopenic defect that fills in on delayed images
    2. Focal retention on delayed images Correct answer.
    3. Early uptake that fades on delayed images
    4. Focal uptake only after perchlorate administration

    Explanation

    Sestamibi washes out of normal thyroid tissue more rapidly than from parathyroid adenoma, so a persistent focus on the 2-hour delayed images localizes the adenoma. Single-isotope dual-phase imaging takes advantage of this differential washout.

  15. Question 15Diagnostic Procedures / Clinical Applications

    In a standard solid-phase gastric emptying study, the result is usually expressed as the:

    1. Ratio of antral to fundal activity
    2. Time for half the meal to empty Correct answer.
    3. Total counts in the small bowel at 30 minutes
    4. Peak counts in the stomach

    Explanation

    A time-activity curve is generated over the stomach, and the half-emptying time is derived from it, which is prolonged in gastroparesis. The solid meal is labeled with a tracer that is not absorbed, so counts reflect retained food.

  16. Question 16Diagnostic Procedures / Clinical Applications

    Which V/Q scan pattern meets the PIOPED criteria for a high-probability study for pulmonary embolism?

    1. At least two large mismatched defects Correct answer.
    2. One moderate mismatched defect with a normal chest radiograph
    3. Matched defects in three or more segments
    4. A single small matched subsegmental defect

    Explanation

    High probability requires at least two large mismatched perfusion defects, each involving more than 75 percent of a segment, with normal ventilation and no corresponding radiographic opacity. A single moderate mismatch is only intermediate probability.

  17. Question 17Diagnostic Procedures / Clinical Applications

    Morphine sulfate is sometimes administered during a HIDA scan to:

    1. Accelerate hepatic clearance of tracer
    2. Promote gallbladder filling Correct answer.
    3. Prevent biliary reflux into stomach
    4. Reduce patient motion during imaging

    Explanation

    Morphine raises sphincter of Oddi tone and increases intraductal pressure, which forces tracer into the gallbladder when the cystic duct is patent. If the gallbladder still fails to fill after morphine, cystic duct obstruction is confirmed.

  18. Question 18Diagnostic Procedures / Clinical Applications

    On a Tc-99m sulfur colloid liver-spleen scan, focal nodular hyperplasia usually appears as:

    1. Diffusely increased splenic uptake
    2. A defect that fills in only with hepatobiliary tracer
    3. Normal or increased uptake from Kupffer cells Correct answer.
    4. A photon-deficient defect

    Explanation

    Focal nodular hyperplasia contains Kupffer cells, so it takes up sulfur colloid at a level equal to or greater than normal liver. Hepatic adenoma lacks Kupffer cells and therefore appears as a photon-deficient defect.

  19. Question 19Diagnostic Procedures / Clinical Applications

    I-123 MIBG scintigraphy is most useful for imaging:

    1. Bone metastases from prostate cancer
    2. Pheochromocytoma and neuroblastoma Correct answer.
    3. Infection and inflammation
    4. Somatostatin receptor-positive tumors

    Explanation

    MIBG is a norepinephrine analog taken up by the amine transporter of adrenergic tissue, so it localizes chromaffin tumors such as pheochromocytoma, paraganglioma, and neuroblastoma. Normal uptake is seen in the salivary glands, liver, spleen, and heart.

  20. Question 20Diagnostic Procedures / Clinical Applications

    During a Tc-99m DTPA study for suspected brain death, the finding of tracer in the facial and nasal areas with no intracranial activity is called the:

    1. Cranial blush
    2. Empty delta sign
    3. Hot nose sign Correct answer.
    4. Tentorial sign

    Explanation

    When cerebral perfusion has ceased, external carotid flow persists and is seen as prominent activity in the nose and face while the cerebral hemispheres remain photopenic. This hot nose sign supports the diagnosis of brain death in the appropriate clinical setting.

  21. Question 21Diagnostic Procedures / Clinical Applications

    A patient with severe left ventricular dysfunction shows a region of reduced perfusion on SPECT but preserved FDG uptake on PET. This pattern indicates:

    1. Viable hibernating myocardium Correct answer.
    2. Normal myocardium
    3. Artifact from diaphragmatic attenuation
    4. Transmural myocardial infarction

    Explanation

    Perfusion-metabolism mismatch, meaning reduced perfusion with preserved glucose metabolism, identifies hibernating myocardium that may recover function after revascularization. A matched reduction in both perfusion and FDG uptake indicates scar.

  22. Question 22Diagnostic Procedures / Clinical Applications

    Compared with In-111 labeled leukocyte imaging, Ga-67 citrate scintigraphy is less specific for infection mainly because gallium:

    1. Accumulates in tumors and sterile inflammation Correct answer.
    2. Cannot be imaged until 24-48 hours after injection
    3. Has a physical half-life too short for delayed imaging
    4. Is excreted primarily through the lungs and gut

    Explanation

    Gallium binds transferrin and lactoferrin, so it localizes in neoplasms, healing wounds, and sterile inflammatory foci as well as in infection, lowering specificity. Labeled leukocytes migrate specifically toward chemotactic stimuli of infection.

  23. Question 23Diagnostic Procedures / Clinical Applications

    On a testicular scan, which pattern favors acute epididymitis over testicular torsion?

    1. Absent perfusion on the dynamic phase
    2. Delayed appearance of both testes
    3. Increased perfusion and uptake Correct answer.
    4. A photopenic defect in the affected hemiscrotum

    Explanation

    Inflammation increases blood flow and capillary permeability, producing a hot hemiscrotum on both the flow and static phases. Torsion abolishes arterial supply and produces decreased flow with a photopenic testis, requiring immediate surgical attention.

  24. Question 24Diagnostic Procedures / Clinical Applications

    Which study is used to detect vesicoureteral reflux without intravenous tracer administration?

    1. Direct radionuclide cystogram Correct answer.
    2. Captopril renogram
    3. Indirect radionuclide cystogram
    4. Diuretic renogram

    Explanation

    In a direct radionuclide cystogram, tracer is instilled into the bladder through a catheter, so reflux is detected without any intravenous injection. The indirect technique uses intravenously administered MAG3 and relies on voiding after renal excretion.

  25. Question 25Diagnostic Procedures / Clinical Applications

    A shunt patency study is performed by injecting Tc-99m DTPA into the reservoir of a ventriculoperitoneal shunt. Normal patency is demonstrated by:

    1. Accumulation of activity over the cerebral convexity
    2. Rapid clearance of activity from the tubing
    3. Activity confined to the shunt tubing
    4. Activity appearing in the peritoneal cavity Correct answer.

    Explanation

    After reservoir injection, tracer should flow through the distal tubing and reach the peritoneal cavity within minutes, confirming distal patency. Persistence of activity within the tubing or reservoir indicates obstruction.

  26. Question 26Diagnostic Procedures / Clinical Applications

    Which radiopharmaceutical is used for a Meckel's diverticulum scan?

    1. Tc-99m sulfur colloid
    2. Tc-99m MDP
    3. In-111 oxine-labeled leukocytes
    4. Tc-99m pertechnetate Correct answer.

    Explanation

    Tc-99m pertechnetate is taken up by ectopic gastric mucosa, which is present in most symptomatic Meckel's diverticula. Focal uptake in the right lower abdomen that appears with gastric mucosa and moves with bowel is characteristic.

  27. Question 27Diagnostic Procedures / Clinical Applications

    Gated equilibrium blood-pool (MUGA) imaging is most commonly performed to measure which parameter?

    1. Glomerular filtration rate
    2. Thyroid radioiodine uptake
    3. Left ventricular ejection fraction Correct answer.
    4. Hepatic extraction fraction

    Explanation

    Gated blood-pool imaging uses Tc-99m-labeled red blood cells to create ECG-synchronized frames of the cardiac chambers. The change in counts between end diastole and end systole is used to calculate left ventricular ejection fraction and wall motion.

  28. Question 28Diagnostic Procedures / Clinical Applications

    A 24-hour radioiodine uptake measurement is used primarily to evaluate which thyroid function?

    1. Bone mineralization rate
    2. Renal tubular secretion of iodide
    3. Parathyroid hormone reserve
    4. Thyroid iodine trapping and organification Correct answer.

    Explanation

    The 24-hour radioiodine uptake quantifies the fraction of administered I-123 or I-131 retained by the thyroid. It reflects both iodide trapping and organification and is used to evaluate hyperthyroidism and thyroiditis.

  29. Question 29Diagnostic Procedures / Clinical Applications

    Which radiopharmaceutical is used for a standard whole-body bone scan?

    1. Tc-99m MDP Correct answer.
    2. Tc-99m sulfur colloid
    3. Tc-99m pertechnetate
    4. Tc-99m DTPA

    Explanation

    Tc-99m MDP (or an equivalent diphosphonate) adsorbs to hydroxyapatite in bone and is the standard agent for skeletal scintigraphy. Areas of increased bone turnover show increased uptake.

  30. Question 30Diagnostic Procedures / Clinical Applications

    On a three-phase Tc-99m MDP bone scan, which pattern favors osteomyelitis over adjacent cellulitis?

    1. Increased arterial flow and blood pool with normal delayed bone uptake
    2. Normal arterial flow and blood pool with increased delayed bone uptake
    3. Decreased arterial flow and blood pool with a photopenic delayed bone defect
    4. Increased arterial flow and blood pool with focally increased delayed bone uptake Correct answer.

    Explanation

    Osteomyelitis produces hyperemia on the flow and blood-pool phases plus focal osseous uptake on the delayed phase. Cellulitis produces hyperemia without delayed bone localization.

  31. Question 31Diagnostic Procedures / Clinical Applications

    A neonate with persistent jaundice undergoes a Tc-99m hepatobiliary scan after phenobarbital pretreatment. Absence of bowel activity at 24 hours is most consistent with which diagnosis?

    1. Common bile duct stone
    2. Acute cholecystitis
    3. Hepatic hemangioma
    4. Biliary atresia Correct answer.

    Explanation

    In neonatal hepatobiliary scanning, phenobarbital is given to enhance bile flow and enzyme induction. Failure to see tracer in the bowel by 24 hours indicates obstruction to bile excretion and is the classic pattern of biliary atresia.

  32. Question 32Diagnostic Procedures / Clinical Applications

    Which preparation is required before a diagnostic I-131 whole-body scan in a patient who has undergone thyroidectomy for thyroid cancer?

    1. A 12-hour fast and bowel preparation
    2. Potassium iodide loading to block the thyroid
    3. A low-iodine diet and TSH stimulation Correct answer.
    4. A high-iodine diet and thyroid hormone suppression

    Explanation

    Radioiodine uptake by residual thyroid tissue or metastases is maximized by iodine depletion and elevated TSH. A low-iodine diet plus either thyroid hormone withdrawal or recombinant TSH is standard.

  33. Question 33Diagnostic Procedures / Clinical Applications

    A hepatic hemangioma is best characterized on which study as a region of increased uptake on delayed images?

    1. Tc-99m labeled RBC SPECT Correct answer.
    2. Tc-99m MDP bone scan
    3. Ga-67 citrate scan
    4. Tc-99m sulfur colloid liver-spleen scan

    Explanation

    Cavernous hemangiomas have slow blood-pool filling, so labeled RBC imaging shows increased activity on delayed SPECT images. This reflects the lesion's large vascular spaces.

  34. Question 34Diagnostic Procedures / Clinical Applications

    I-123 ioflupane (DaTscan) imaging is used to assess which structure or function?

    1. Myocardial sympathetic innervation
    2. Presynaptic dopaminergic terminals in the striatum Correct answer.
    3. Bone marrow reticuloendothelial function
    4. Somatostatin receptor expression

    Explanation

    Ioflupane binds the dopamine transporter on presynaptic nigrostriatal terminals. Reduced striatal uptake supports a Parkinsonian syndrome rather than essential tremor.

  35. Question 35Diagnostic Procedures / Clinical Applications

    Which radiopharmaceutical is used to evaluate splenic sequestration in a child with hereditary spherocytosis?

    1. Heat-damaged Tc-99m labeled RBCs Correct answer.
    2. In-111 oxine-labeled leukocytes
    3. Tc-99m MDP
    4. Tc-99m sulfur colloid

    Explanation

    Heat-damaged RBCs are trapped preferentially by the spleen, allowing splenic sequestration to be quantified. Comparing splenic with hepatic activity helps determine whether splenectomy is likely to benefit the patient.

  36. Question 36Diagnostic Procedures / Clinical Applications

    In-111 pentetreotide (Octreoscan) imaging is most useful for detecting tumors that express which receptor?

    1. Thyroid peroxidase
    2. Somatostatin receptors Correct answer.
    3. Prostate-specific membrane antigen
    4. Dopamine transporters

    Explanation

    Pentetreotide is a somatostatin analog and binds somatostatin receptors, which are overexpressed by many neuroendocrine tumors. It is used for staging and localization of those tumors.

  37. Question 37Diagnostic Procedures / Clinical Applications

    68Ga-PSMA-11 PET/CT is used primarily to evaluate which malignancy?

    1. Neuroendocrine tumors
    2. Differentiated thyroid cancer
    3. Breast carcinoma
    4. Prostate cancer Correct answer.

    Explanation

    PSMA is overexpressed on prostate cancer cells, so PSMA PET/CT is used for staging and localization of recurrent prostate cancer. It is not a general-purpose oncologic tracer.

  38. Question 38Diagnostic Procedures / Clinical Applications

    A renal transplant recipient has rising creatinine. A Tc-99m MAG3 scan shows a progressive tracer collection inferior to the graft that enlarges on delayed images. This finding most likely represents which complication?

    1. Cyclosporine toxicity
    2. Acute tubular necrosis
    3. Acute rejection
    4. Urinary leak Correct answer.

    Explanation

    A progressive collection of tracer outside the urinary tract that enlarges over time is characteristic of a urine leak or urinoma. It is distinct from parenchymal dysfunction, which alters uptake and excretion rather than creating an expanding extrarenal collection.

  39. Question 39Diagnostic Procedures / Clinical Applications

    During a Tc-99m MAA perfusion lung scan, which finding indicates a right-to-left shunt?

    1. Increased tracer uptake in the liver
    2. Multiple segmental perfusion defects in the lungs
    3. Uniform tracer distribution throughout both lungs
    4. Uptake of tracer in the brain and kidneys Correct answer.

    Explanation

    MAA particles are normally trapped in the pulmonary capillary bed. In a right-to-left shunt, particles bypass the lungs and lodge in systemic capillary beds, producing uptake in organs such as the brain and kidneys.

  40. Question 40Diagnostic Procedures / Clinical Applications

    A periprosthetic region shows increased uptake on both In-111 labeled leukocyte imaging and Tc-99m sulfur colloid marrow imaging. This concordant pattern most likely represents which finding?

    1. Acute fracture
    2. Aseptic loosening
    3. Prosthetic joint infection
    4. Normal bone marrow Correct answer.

    Explanation

    Labeled leukocyte uptake that matches the distribution of bone marrow on sulfur colloid imaging indicates normal marrow rather than infection. Infection is suggested by leukocyte uptake that is discordant with marrow.

  41. Question 41Radiopharmacy and Radiopharmaceuticals

    The physical half-life of Tc-99m is:

    1. 6 hours Correct answer.
    2. 110 minutes
    3. 13 hours
    4. 66 hours

    Explanation

    Tc-99m decays by isomeric transition with a physical half-life of about 6 hours and emits a 140 keV gamma ray. This short half-life limits the useful life of an eluate to roughly 12 hours while keeping patient absorbed dose low.

  42. Question 42Radiopharmacy and Radiopharmaceuticals

    A Mo-99/Tc-99m generator is eluted with which solution?

    1. 0.1 N hydrochloric acid
    2. Sodium bicarbonate 8.4%
    3. Sterile water for injection
    4. 0.9% sodium chloride Correct answer.

    Explanation

    Normal saline passes through the alumina column, and the chloride ion displaces pertechnetate from the column binding sites, yielding sodium pertechnetate. Water alone elutes poorly, and acid or alkaline solutions would degrade the column and the product.

  43. Question 43Radiopharmacy and Radiopharmaceuticals

    Which radiopharmaceutical is used for skeletal scintigraphy?

    1. Tc-99m DTPA
    2. Tc-99m MDP Correct answer.
    3. Tc-99m pertechnetate
    4. Tc-99m sulfur colloid

    Explanation

    Tc-99m MDP adsorbs onto the hydroxyapatite crystal surface of bone, with uptake proportional to regional blood flow and osteoblastic activity. The other agents localize to the reticuloendothelial system, the kidneys, or thyroid and gastric mucosa.

  44. Question 44Radiopharmacy and Radiopharmaceuticals

    Which radionuclide has a physical half-life of approximately 110 minutes?

    1. Ga-67
    2. Tc-99m
    3. I-123
    4. F-18 Correct answer.

    Explanation

    F-18 decays by positron emission with a half-life of about 110 minutes, which limits how far it can be shipped and sets the practical daily workflow for FDG. Tc-99m, Ga-67, and I-123 have much longer half-lives.

  45. Question 45Radiopharmacy and Radiopharmaceuticals

    Which radiopharmaceutical is taken up by hepatocytes and excreted into the biliary tree?

    1. Tc-99m sulfur colloid
    2. Tc-99m mebrofenin Correct answer.
    3. Tc-99m RBCs
    4. Tc-99m MAA

    Explanation

    Iminodiacetic acid derivatives such as mebrofenin are carried into hepatocytes by organic anion transporters and then excreted in bile, allowing assessment of gallbladder filling and biliary patency. The other agents are handled by phagocytes, lung capillaries, or the vascular space.

  46. Question 46Radiopharmacy and Radiopharmaceuticals

    Which photon energy is emitted by Tc-99m and makes it well suited to the gamma camera?

    1. 140 keV Correct answer.
    2. 511 keV
    3. 364 keV
    4. 245 keV

    Explanation

    The 140 keV gamma of Tc-99m is high enough to escape the patient yet low enough to be efficiently collimated and absorbed in a sodium iodide crystal. This favorable energy is a major reason Tc-99m is the most widely used imaging nuclide.

  47. Question 47Radiopharmacy and Radiopharmaceuticals

    Which radiopharmaceutical is used for myocardial perfusion imaging?

    1. Tc-99m sestamibi Correct answer.
    2. Tc-99m sulfur colloid
    3. Tc-99m DTPA
    4. Tc-99m MAA

    Explanation

    Tc-99m sestamibi is a lipophilic cation that accumulates in myocardial mitochondria in proportion to regional blood flow, making it useful for perfusion imaging. The other agents distribute to lung capillaries, the reticuloendothelial system, or the kidneys.

  48. Question 48Radiopharmacy and Radiopharmaceuticals

    Which radiopharmaceutical is preferred for thyroid scintigraphy because it delivers a much lower absorbed dose than I-131?

    1. I-131
    2. Tc-99m MAA
    3. I-123 Correct answer.
    4. Ga-67 citrate

    Explanation

    I-123 decays by electron capture, emitting a 159 keV gamma with no beta particles, so it gives high-quality thyroid images at a fraction of the dose from I-131. I-131 emits beta radiation that deposits a much larger absorbed dose in the gland.

  49. Question 49Radiopharmacy and Radiopharmaceuticals

    Which method is used to check a Tc-99m eluate for Mo-99 breakthrough?

    1. Measure the eluate pH with indicator paper
    2. Inspect the eluate for visible particles
    3. Count the eluate in a well counter after 24 hours of decay
    4. Assay through a lead shield in a dose calibrator Correct answer.

    Explanation

    Mo-99 emits a 740 keV gamma that passes through a lead shield which attenuates the 140 keV photons of Tc-99m. Assaying the shielded vial therefore reveals any Mo-99 present, and the result must not exceed 0.15 kBq Mo-99 per MBq Tc-99m.

  50. Question 50Radiopharmacy and Radiopharmaceuticals

    Radiochemical purity of a Tc-99m labeled radiopharmaceutical is determined by which technique?

    1. Dose calibrator assay of the shielded vial
    2. Thin-layer chromatography Correct answer.
    3. Daily constancy testing of the calibrator
    4. Gamma ray spectroscopy of the vial

    Explanation

    Chromatography on paper or instant thin-layer strips separates the labeled product from free pertechnetate and hydrolyzed-reduced technetium, and the fraction of activity in the product band gives radiochemical purity. Spectroscopy and calibrator assays measure other properties.

  51. Question 51Radiopharmacy and Radiopharmaceuticals

    A patient with severe pulmonary hypertension is scheduled for a perfusion lung scan. How should the Tc-99m MAA dose be modified?

    1. Reduce the number of particles administered Correct answer.
    2. Administer the dose by slow IV push over 10 minutes
    3. Increase the particle number to improve count statistics
    4. No modification is required

    Explanation

    MAA particles transiently block a small fraction of pulmonary capillaries, so the particle number is reduced (commonly to 100,000 to 200,000) when pulmonary vascular reserve is limited. This lowers the fraction of blocked capillary bed and the chance that particles pass through into the systemic circulation.

  52. Question 52Radiopharmacy and Radiopharmaceuticals

    Tc-99m MAG3 is cleared from plasma primarily by:

    1. Glomerular filtration
    2. Reticuloendothelial phagocytosis
    3. Tubular secretion Correct answer.
    4. Hepatocyte transport

    Explanation

    MAG3 is secreted by the proximal tubules and has a high extraction fraction, which preserves image quality even when glomerular filtration is impaired. Agents cleared only by filtration lose image quality as renal function declines.

  53. Question 53Radiopharmacy and Radiopharmaceuticals

    In-111 pentetreotide localizes in neuroendocrine tumors by binding to which target?

    1. Sodium-iodide symporter
    2. Somatostatin receptors Correct answer.
    3. Transferrin receptors
    4. Hydroxyapatite crystal surface

    Explanation

    Pentetreotide is a radiolabeled octreotide analog that binds somatostatin receptors, predominantly subtype 2, expressed on the surface of neuroendocrine tumor cells. This receptor binding is the basis of somatostatin receptor scintigraphy.

  54. Question 54Radiopharmacy and Radiopharmaceuticals

    Which instruction should be given to a patient before an F-18 FDG PET study?

    1. Fast for 4 to 6 hours before injection Correct answer.
    2. Take rapid-acting insulin just before injection
    3. Exercise vigorously before injection
    4. Drink a glucose-containing beverage 1 hour before

    Explanation

    Fasting for at least 4 to 6 hours lowers serum glucose and insulin so that FDG uptake reflects tissue metabolism rather than recent intake. High glucose or insulin shifts tracer into muscle and fat and degrades lesion contrast.

  55. Question 55Radiopharmacy and Radiopharmaceuticals

    A Tc-99m eluate is assayed at 0800 and contains 800 MBq. What activity remains at 1400 the same day?

    1. 200 MBq
    2. 600 MBq
    3. 400 MBq Correct answer.
    4. 100 MBq

    Explanation

    Six hours equals one half-life of Tc-99m, so the activity is halved once: 800 MBq x 0.5 = 400 MBq. Each additional 6 hours would again reduce the remaining activity by half.

  56. Question 56Radiopharmacy and Radiopharmaceuticals

    Which radiopharmaceutical is used to detect a Meckel's diverticulum containing ectopic gastric mucosa?

    1. Tc-99m pertechnetate Correct answer.
    2. Tc-99m MAA
    3. Tc-99m MDP
    4. Tc-99m sulfur colloid

    Explanation

    Pertechnetate is trapped by the mucin-secreting cells of ectopic gastric mucosa, so the diverticulum appears as a focal area of activity in the right lower abdomen that appears and fades with the stomach.

  57. Question 57Radiopharmacy and Radiopharmaceuticals

    Which Tc-99m agent crosses the intact blood-brain barrier and is retained in the brain in proportion to regional blood flow?

    1. Tc-99m DTPA
    2. Tc-99m MDP
    3. Tc-99m MAA
    4. Tc-99m ECD Correct answer.

    Explanation

    Tc-99m ECD, like HMPAO, is a lipophilic neutral complex that diffuses into brain cells and is hydrolyzed to a hydrophilic form that cannot leave, so retention follows perfusion. The other agents remain intravascular, distribute to bone, or are trapped in the lungs.

  58. Question 58Radiopharmacy and Radiopharmaceuticals

    Which dose calibrator test verifies a reproducible response using a long-lived reference source from day to day?

    1. Constancy Correct answer.
    2. Geometry
    3. Linearity
    4. Accuracy

    Explanation

    The constancy (daily) test measures a long-lived source such as Cs-137 or Co-57 and confirms that the reading matches the expected value within tolerance, documenting reproducible response over time. Linearity, accuracy, and geometry evaluate other performance characteristics.

  59. Question 59Radiopharmacy and Radiopharmaceuticals

    The expiration time of a Tc-99m labeled radiopharmaceutical is determined by:

    1. Twenty-four hours after generator calibration
    2. The generator calibration date
    3. The earlier of kit or eluate expiration Correct answer.
    4. The kit manufacturer's expiration time alone

    Explanation

    A labeled product may be used only until the first of two limits is reached: the expiration stated by the kit manufacturer, or the expiration of the eluate used (12 hours after elution). Whichever comes first governs the beyond-use time.

  60. Question 60Radiopharmacy and Radiopharmaceuticals

    I-131 therapy for Graves disease is contraindicated in which situation?

    1. Pregnancy Correct answer.
    2. Age greater than 50 years
    3. Small goiter volume
    4. Prior partial thyroidectomy

    Explanation

    Iodine-131 crosses the placenta, and the fetal thyroid begins concentrating iodine at roughly 10 to 12 weeks, so exposure can cause permanent fetal hypothyroidism. Pregnancy must be excluded before therapy, and lactation is also a contraindication.

  61. Question 61Radiopharmacy and Radiopharmaceuticals

    Y-90 is a pure beta emitter. How is the distribution of Y-90 microspheres assessed after radioembolization?

    1. The 364 keV gamma emission
    2. The 511 keV annihilation peak
    3. Bremsstrahlung imaging Correct answer.
    4. The 140 keV photopeak

    Explanation

    Y-90 has no useful gamma emission, so the beta particles are detected indirectly through bremsstrahlung photons generated as they are slowed in tissue, imaged with a broad energy window. The other energies belong to Tc-99m, I-131, and positron emitters, respectively.

  62. Question 62Radiopharmacy and Radiopharmaceuticals

    Lu-177 DOTATATE is used for peptide receptor radionuclide therapy. Which emission property allows both therapy and post-treatment imaging?

    1. Pure positron emission
    2. Characteristic x-rays only
    3. Pure alpha emission
    4. Beta minus plus gamma Correct answer.

    Explanation

    Lu-177 decays by beta minus emission with a half-life of about 6.7 days; the beta particles deliver the therapeutic dose while low-abundance gamma photons allow imaging and dosimetry after treatment.

  63. Question 63Radiopharmacy and Radiopharmaceuticals

    What is the maximum allowable Mo-99 concentration in Tc-99m eluate at the time of administration?

    1. 0.15 kBq/MBq Correct answer.
    2. 0.0015 kBq/MBq
    3. 1.5 kBq/MBq
    4. 0.015 kBq/MBq

    Explanation

    The limit is 0.15 kBq (0.15 microcurie) of Mo-99 per 1 MBq (1 mCi) of Tc-99m at the time of administration. An eluate that exceeds this limit must not be used because Mo-99's long half-life and high-energy photons increase patient dose.

  64. Question 64Radiopharmacy and Radiopharmaceuticals

    In-111 oxine labels leukocytes because the complex:

    1. It carries indium across the membrane Correct answer.
    2. It binds to surface immunoglobulin
    3. It enters cells only during phagocytosis
    4. It binds to transferrin receptors

    Explanation

    Indium-111 oxine is lipid soluble and diffuses across the cell membrane; once inside, indium binds intracellular proteins while the oxine chelate diffuses away, trapping the activity within the cell. This labeling is not limited to phagocytic cells.

  65. Question 65Radiopharmacy and Radiopharmaceuticals

    Ra-223 dichloride is used to treat bone metastases. Its therapeutic effect comes primarily from:

    1. Positron emission
    2. Auger electron emission
    3. Alpha particle emission Correct answer.
    4. Beta-minus particle emission

    Explanation

    Ra-223 is a calcium analog that concentrates in areas of high bone turnover and emits high-LET alpha particles with a range under 100 micrometers, killing tumor cells while largely sparing adjacent marrow. Its half-life is about 11 days.

  66. Question 66Radiopharmacy and Radiopharmaceuticals

    In a Tc-99m generator, which radionuclide is the parent that remains bound to the alumina column?

    1. Mo-99 Correct answer.
    2. Sr-89
    3. Tc-99m
    4. I-131

    Explanation

    Mo-99 decays to Tc-99m on the generator column, and the parent Mo-99 is retained while saline elutes Tc-99m pertechnetate. The parent-daughter relationship is the basis of the generator.

  67. Question 67Radiopharmacy and Radiopharmaceuticals

    What is the physical half-life of Tc-99m?

    1. 66 hours
    2. 6 hours Correct answer.
    3. 2 hours
    4. 13 hours

    Explanation

    Tc-99m has a physical half-life of about 6 hours, which allows kit preparation and imaging while limiting the radiation dose to the patient. This half-life is also central to generator elution timing.

  68. Question 68Radiopharmacy and Radiopharmaceuticals

    Which Tc-99m radiopharmaceutical localizes in bone by chemisorption to hydroxyapatite?

    1. Tc-99m MDP Correct answer.
    2. Tc-99m pertechnetate
    3. Tc-99m MAG3
    4. Tc-99m sulfur colloid

    Explanation

    Tc-99m MDP is a diphosphonate that adsorbs to the calcium phosphate crystal surface of bone, especially where osteoblastic activity is increased. This binding is described as chemisorption to hydroxyapatite.

  69. Question 69Radiopharmacy and Radiopharmaceuticals

    In a Tc-99m cold kit, which component reduces pertechnetate to a reactive lower oxidation state?

    1. Stannous ion Correct answer.
    2. Sodium hydroxide
    3. Sodium chloride
    4. Gentisic acid

    Explanation

    Stannous ion donates electrons to reduce pertechnetate so that technetium can bind the kit ligand. Without an adequate reducing agent, labeling efficiency is poor.

  70. Question 70Radiopharmacy and Radiopharmaceuticals

    Which cell type primarily removes Tc-99m sulfur colloid from the hepatic circulation?

    1. Kupffer cells Correct answer.
    2. Renal tubular cells
    3. Hepatocytes
    4. Platelets

    Explanation

    Tc-99m sulfur colloid particles are phagocytosed by reticuloendothelial cells, mainly Kupffer cells in the liver and macrophages in the spleen and marrow. Hepatocytes handle hepatobiliary agents instead.

  71. Question 71Radiopharmacy and Radiopharmaceuticals

    Which Tc-99m radiopharmaceutical is retained in proximal tubular cells and is used for renal cortical imaging?

    1. Tc-99m MDP
    2. Tc-99m MAG3
    3. Tc-99m DTPA
    4. Tc-99m DMSA Correct answer.

    Explanation

    DMSA binds to sulfhydryl groups in proximal tubular cells and remains in the renal cortex, producing high cortical detail. This retention is different from agents that are filtered or secreted into urine.

  72. Question 72Radiopharmacy and Radiopharmaceuticals

    After F-18 FDG enters a cell, it is trapped because it is:

    1. incorporated into DNA during replication
    2. phosphorylated to FDG-6-phosphate and not metabolized further Correct answer.
    3. deiodinated in the cytoplasm
    4. oxidized in mitochondria to carbon dioxide

    Explanation

    FDG is transported by GLUT proteins and phosphorylated by hexokinase. FDG-6-phosphate cannot proceed through glycolysis and is dephosphorylated slowly, so it accumulates in the cell.

  73. Question 73Radiopharmacy and Radiopharmaceuticals

    Which Tc-99m agent is taken up by hepatocytes and excreted into the biliary tree?

    1. Tc-99m mebrofenin Correct answer.
    2. Tc-99m MAA
    3. Tc-99m DTPA
    4. Tc-99m sulfur colloid

    Explanation

    Mebrofenin is an iminodiacetic acid derivative transported by hepatocytes and secreted into bile, so it is used for hepatobiliary imaging. Its biliary excretion allows evaluation of gallbladder and duct function.

  74. Question 74Radiopharmacy and Radiopharmaceuticals

    Which radiopharmaceutical is used for the ventilation phase of a V/Q scan?

    1. Tc-99m MAG3
    2. Tc-99m DTPA aerosol Correct answer.
    3. Tc-99m MAA
    4. Tc-99m sulfur colloid

    Explanation

    Aerosolized Tc-99m DTPA deposits in the airways and alveoli, allowing ventilation to be compared with MAA perfusion. The aerosol particles should reach the lung periphery for a valid ventilation image.

  75. Question 75Radiopharmacy and Radiopharmaceuticals

    I-123 MIBG accumulates in pheochromocytoma because it is taken up by which transporter?

    1. Sodium-iodide symporter
    2. Norepinephrine transporter Correct answer.
    3. Somatostatin receptor
    4. GLUT-1 glucose transporter

    Explanation

    MIBG is a guanethidine analogue that enters adrenergic tissue through the norepinephrine transporter. This uptake mechanism is distinct from iodide handling by the sodium-iodide symporter.

  76. Question 76Radiopharmacy and Radiopharmaceuticals

    Which radiopharmaceutical is used for parathyroid scintigraphy because it accumulates in the mitochondria of parathyroid adenomas?

    1. Tc-99m sulfur colloid
    2. Tc-99m MDP
    3. Tc-99m sestamibi Correct answer.
    4. Tc-99m pertechnetate

    Explanation

    Sestamibi is a lipophilic cation that concentrates in mitochondria-rich tissue, including parathyroid adenomas and myocardium. This property supports delayed parathyroid imaging after thyroid washout.

  77. Question 77Radiopharmacy and Radiopharmaceuticals

    Which kit additive is included to protect a Tc-99m radiopharmaceutical from radiolytic decomposition?

    1. Stannous chloride
    2. Sodium hydroxide
    3. Sodium chloride
    4. Gentisic acid Correct answer.

    Explanation

    Gentisic acid acts as an antioxidant/radioprotectant that scavenges free radicals formed by radiation and limits radiolysis of the labeled product. This helps maintain radiochemical purity during storage.

  78. Question 78Radiopharmacy and Radiopharmaceuticals

    A radiopharmaceutical has a physical half-life of 6 hours and a biological half-life of 12 hours. What is its effective half-life?

    1. 4 hours Correct answer.
    2. 9 hours
    3. 6 hours
    4. 18 hours

    Explanation

    Effective half-life is calculated from 1/Te = 1/Tp + 1/Tb. With a 6-hour physical half-life and 12-hour biological half-life, 1/Te = 1/6 + 1/12 = 3/12, so Te is 4 hours.

  79. Question 79Radiopharmacy and Radiopharmaceuticals

    A Tc-99m generator was last eluted 2 hours ago. Compared with an elution after 24 hours, the Tc-99m activity obtained now will be:

    1. The same, because elution efficiency is constant
    2. Higher, because Mo-99 has decayed
    3. Lower (incomplete ingrowth) Correct answer.
    4. Zero, because the generator is exhausted

    Explanation

    After elution, Tc-99m regrows toward transient equilibrium with Mo-99 over about 24 hours. At 2 hours only a fraction of the daughter activity has ingrown, so the yield is lower than after a full day.

  80. Question 80Radiopharmacy and Radiopharmaceuticals

    Which quality-control test confirms that the radioactivity in an F-18 FDG batch comes from F-18 rather than a longer-lived contaminant?

    1. Chemical purity
    2. Radionuclidic purity Correct answer.
    3. Radiochemical purity
    4. Sterility testing

    Explanation

    Radionuclidic purity is assessed by measuring the half-life and gamma spectrum; a contaminating radionuclide would alter the measured decay or spectrum. This test is distinct from tests of labeled versus free radioactivity.

  81. Question 81Instrumentation and Image Production (including PET and CT)

    What is the primary function of the photomultiplier tubes in a gamma camera?

    1. Convert incident gamma rays directly into an electric current
    2. Collimate incident gamma rays before they reach the crystal
    3. Filter scattered photons by means of a pulse height analyzer
    4. Convert scintillation light into an amplified electrical pulse Correct answer.

    Explanation

    Photomultiplier tubes are optically coupled to the crystal and convert each scintillation light flash into a proportional electrical pulse, multiplying the signal through a series of dynodes. The summed and weighted tube signals are then used to determine energy and position.

  82. Question 82Instrumentation and Image Production (including PET and CT)

    Why is thallium added to the sodium iodide crystal used in a gamma camera?

    1. To make the crystal nonhygroscopic and easier to handle
    2. To lower the 140-keV photopeak to a more usable energy
    3. To activate the crystal so it scintillates in the visible range Correct answer.
    4. To raise the crystal's density so that more gamma rays are stopped

    Explanation

    Thallium acts as an activator that creates luminescence centers, allowing the crystal to emit visible light with high efficiency after energy deposition. Without the dopant, the light output would be far too low for practical imaging.

  83. Question 83Instrumentation and Image Production (including PET and CT)

    A 20% energy window is centered on the 140-keV photopeak of Tc-99m. Which energy range will be accepted?

    1. 112 to 168 keV
    2. 126 to 154 keV Correct answer.
    3. 120 to 160 keV
    4. 130 to 150 keV

    Explanation

    A 20% window spans 10% above and 10% below the photopeak energy. Ten percent of 140 keV is 14 keV, so the accepted range is 126 to 154 keV.

  84. Question 84Instrumentation and Image Production (including PET and CT)

    For a parallel-hole collimator, how does spatial resolution change as the distance between the source and the collimator face increases?

    1. It improves progressively
    2. It remains essentially unchanged
    3. It improves briefly, then plateaus
    4. It worsens progressively Correct answer.

    Explanation

    Geometric blur from a parallel-hole collimator grows with source-to-collimator distance, so resolution degrades as the distance increases. Sensitivity, in contrast, is essentially independent of distance for a parallel-hole design.

  85. Question 85Instrumentation and Image Production (including PET and CT)

    In an Anger-type gamma camera, the x-y position of a scintillation event is determined by:

    1. Summing the total energy deposited in the crystal
    2. Measuring the time delay between the first and last tube to fire
    3. Identifying the single tube that received the most light
    4. Comparing relative signals from the photomultiplier tubes Correct answer.

    Explanation

    Anger logic weights the outputs of all tubes that share the light from an event, and the relative signal amplitudes are combined to compute an interpolated x-y position. This allows spatial localization far finer than the diameter of an individual tube.

  86. Question 86Instrumentation and Image Production (including PET and CT)

    Compared with a low-energy high-resolution collimator, a low-energy high-sensitivity collimator has:

    1. Wider holes and thinner septa Correct answer.
    2. Wider holes and thicker septa
    3. Longer holes and thicker septa
    4. Longer holes and thinner septa

    Explanation

    Sensitivity rises as hole diameter increases and as hole length decreases, so high-sensitivity designs use wider, shorter holes with thinner septa. The cost of this design is degraded spatial resolution.

  87. Question 87Instrumentation and Image Production (including PET and CT)

    The overall system spatial resolution of a gamma camera image is determined by:

    1. The intrinsic resolution of the crystal alone
    2. The collimator resolution measured in air alone
    3. The energy resolution combined with detector uniformity
    4. Intrinsic and collimator resolution combined Correct answer.

    Explanation

    System resolution is the quadrature sum of intrinsic resolution and collimator resolution, measured with a line source at a stated distance. Because the terms add in quadrature, the poorer of the two dominates the final result.

  88. Question 88Instrumentation and Image Production (including PET and CT)

    A gamma camera with paralyzable dead time is exposed to a source of steadily increasing activity. The observed count rate will:

    1. Increase linearly with activity without limit
    2. Decrease steadily from the start of the exposure
    3. Increase to a maximum, then decline Correct answer.
    4. Increase, then level off on a plateau

    Explanation

    In a paralyzable system every detected event extends the dead period, so at very high activities the observed rate reaches a peak and then falls as more events are lost. A nonparalyzable system, in contrast, approaches a plateau equal to the reciprocal of the dead time.

  89. Question 89Instrumentation and Image Production (including PET and CT)

    On a CT image, water is assigned a Hounsfield unit value of:

    1. +1000
    2. 0 Correct answer.
    3. -1000
    4. +100

    Explanation

    The Hounsfield scale is defined so that water equals 0 HU and air equals -1000 HU. Values are calculated as 1000 times the difference between the tissue attenuation coefficient and that of water, divided by the water coefficient.

  90. Question 90Instrumentation and Image Production (including PET and CT)

    Increasing the window width on a CT display will:

    1. Decrease image contrast Correct answer.
    2. Improve the spatial resolution
    3. Increase image contrast
    4. Shift the gray scale to denser tissues

    Explanation

    Window width sets how many Hounsfield units are mapped across the full gray scale, so a wider window places more HU values into each gray level and lowers displayed contrast. Window level, not width, determines which tissues are centered in the gray scale.

  91. Question 91Instrumentation and Image Production (including PET and CT)

    In helical CT, pitch is defined as:

    1. Table feed per rotation divided by beam collimation Correct answer.
    2. The ratio of gantry rotation time to total scan time
    3. The ratio of reconstructed slice thickness to detector width
    4. The number of detector rows divided by the total tube current

    Explanation

    Pitch equals the distance the table travels during one gantry rotation divided by the total collimated beam width. A pitch below 1 indicates overlapping acquisitions, while a pitch above 1 indicates gaps in the axial coverage for a single-slice geometry.

  92. Question 92Instrumentation and Image Production (including PET and CT)

    Compared with filtered back projection, iterative reconstruction in CT generally:

    1. Produces images with more quantum mottle
    2. Requires a higher radiation dose for the same noise
    3. Reduces image noise at the same radiation dose Correct answer.
    4. Reconstructs images faster than filtered back projection

    Explanation

    Iterative reconstruction repeatedly models the acquisition geometry and noise statistics, allowing images with lower noise at a given dose or comparable quality at a reduced dose. The trade-off is greater computational demand, so reconstruction takes longer than filtered back projection.

  93. Question 93Instrumentation and Image Production (including PET and CT)

    When a positron annihilates with an electron, the two resulting 511-keV photons are emitted:

    1. At 45 degrees to each other
    2. At 90 degrees to each other
    3. In opposite directions Correct answer.
    4. In the same direction

    Explanation

    Conservation of momentum requires the two annihilation photons to travel almost exactly 180 degrees apart, each carrying 511 keV. This back-to-back emission is the basis of coincidence detection in PET.

  94. Question 94Instrumentation and Image Production (including PET and CT)

    Which scintillation material is widely used in PET detectors because of its high light output and short decay time?

    1. Cesium iodide doped with thallium
    2. Lutetium oxyorthosilicate Correct answer.
    3. Sodium iodide doped with thallium
    4. Bismuth germanate

    Explanation

    Lutetium oxyorthosilicate and its variants provide high light yield with a decay time of roughly 40 nanoseconds, which supports time-of-flight imaging. Bismuth germanate has excellent stopping power but much lower light output and a slower decay.

  95. Question 95Instrumentation and Image Production (including PET and CT)

    Time-of-flight PET improves image quality mainly by:

    1. Removing the need for measured attenuation correction
    2. Increasing the number of detected coincidence events
    3. Reducing the energy of the annihilation photons
    4. Localizing the event along the line of response Correct answer.

    Explanation

    Very small differences in photon arrival times at the two detectors indicate where along the line of response the annihilation occurred. This localization reduces the propagation of noise during reconstruction and improves signal-to-noise ratio, especially in large patients.

  96. Question 96Instrumentation and Image Production (including PET and CT)

    In PET imaging, random coincidence events:

    1. Rise roughly as the square of the activity Correct answer.
    2. Result from a single photon being counted twice
    3. Are eliminated by widening the energy window
    4. Occur only in time-of-flight PET scanners

    Explanation

    The random coincidence rate is approximately twice the coincidence resolving time multiplied by the singles rates from each detector, so it grows with the square of the activity in the field of view. Randoms are reduced by shortening the coincidence timing window and by lowering the activity per line of response.

  97. Question 97Instrumentation and Image Production (including PET and CT)

    In a PET/CT scanner, the CT transmission images are used primarily to:

    1. Correct PET emission data for attenuation Correct answer.
    2. Shorten the overall PET acquisition time
    3. Measure the patient's glomerular filtration rate
    4. Determine the PET scanner's energy resolution

    Explanation

    CT numbers are converted to attenuation coefficients at 511 keV so that the emission data can be corrected for photon attenuation, which is necessary for quantitative SUV measurements. The CT also provides anatomic correlation, but the quantitative purpose of the transmission information is attenuation correction.

  98. Question 98Instrumentation and Image Production (including PET and CT)

    The center-of-rotation test on a rotating gamma camera verifies that:

    1. The collimator septa are correctly aligned
    2. The photopeak energy window is centered correctly
    3. The axis of rotation matches the image matrix center Correct answer.
    4. The uniformity correction map is still current and accurate

    Explanation

    The test confirms that the mechanical axis of rotation corresponds to the center of the acquisition matrix. A significant offset misregisters opposing projections, producing blurred reconstructed images and characteristic artifacts.

  99. Question 99Instrumentation and Image Production (including PET and CT)

    In filtered back projection of SPECT data, the ramp filter is applied to:

    1. Compensate for blurring inherent in back projection Correct answer.
    2. Correct for photon attenuation within the patient
    3. Normalize the detector uniformity response
    4. Suppress statistical noise in the projection images

    Explanation

    Simple back projection produces a 1/r blur, and the ramp filter corrects this by amplifying higher spatial frequencies. Because the ramp also amplifies noise, a smoothing window such as a Butterworth or Hann filter is applied at the same time.

  100. Question 100Instrumentation and Image Production (including PET and CT)

    For a fixed field of view, changing the acquisition matrix from 128x128 to 256x256 will:

    1. Reduce the total number of pixels in the image
    2. Decrease pixel size and improve spatial resolution Correct answer.
    3. Increase the counts recorded in each pixel
    4. Increase pixel size and improve sensitivity

    Explanation

    Pixel size equals the field of view divided by the matrix dimension, so doubling the matrix halves the pixel dimension. Because the total counts are unchanged, the counts per pixel decrease, which increases image noise unless more counts are acquired.

  101. Question 101Instrumentation and Image Production (including PET and CT)

    An 8-bit digital display can present how many shades of gray?

    1. 512
    2. 64
    3. 1024
    4. 256 Correct answer.

    Explanation

    Bit depth determines the number of available gray levels as 2 raised to the bit depth. For 8 bits, 2 to the eighth power equals 256 levels.

  102. Question 102Instrumentation and Image Production (including PET and CT)

    A daily uniformity (flood) image of a gamma camera is used to evaluate:

    1. Uniformity of detector response Correct answer.
    2. The spatial resolution of the collimator
    3. The accuracy of the dose calibrator
    4. The energy resolution of the detector

    Explanation

    A uniform flood source reveals regional differences in detector sensitivity arising from tube gain drift, crystal damage, or collimator defects. The image is used to generate and verify the uniformity correction map.

  103. Question 103Instrumentation and Image Production (including PET and CT)

    Which dose calibrator test evaluates whether the measured activity depends on sample volume or container type?

    1. Constancy test
    2. Geometry test Correct answer.
    3. Accuracy test
    4. Linearity test

    Explanation

    The geometry test measures the same amount of activity in different volumes, shapes, and containers to confirm that the reading is independent of sample geometry. This matters because syringes, vials, and capsules present very different counting geometries.

  104. Question 104Instrumentation and Image Production (including PET and CT)

    Intrinsic spatial resolution of a gamma camera is measured using:

    1. A line source with the collimator removed Correct answer.
    2. A bar phantom with the collimator left in place
    3. A point source 10 cm from the collimator face
    4. A flood source with the collimator left in place

    Explanation

    Intrinsic resolution describes the detector's own ability to localize an event, so it must be measured with the collimator removed using a line source or fine bar phantom. Measurements made with the collimator in place yield system resolution instead.

  105. Question 105Instrumentation and Image Production (including PET and CT)

    Why must CT Hounsfield units be transformed before they are used for PET attenuation correction?

    1. Tissue attenuation differs between CT energies and 511 keV Correct answer.
    2. CT numbers vary with tube rotation speed and tube current
    3. CT images inherently have poorer spatial resolution than PET
    4. CT acquisitions in PET/CT are usually done without contrast

    Explanation

    CT attenuation data are acquired with x-ray energies well below 511 keV, where photoelectric and Compton interactions contribute differently. A bilinear or similar conversion therefore rescales CT numbers into attenuation coefficients appropriate for 511-keV photons.

  106. Question 106Instrumentation and Image Production (including PET and CT)

    What is the primary role of the photomultiplier tubes in a gamma camera?

    1. Focus gamma rays onto the crystal surface
    2. Discriminate scattered photons by their pulse height
    3. Amplify and convert light to an electrical pulse Correct answer.
    4. Collimate incoming photons before they reach the crystal

    Explanation

    Photomultiplier tubes are optically coupled to the NaI(Tl) crystal. Their photocathode converts scintillation light into electrons, and the dynode chain amplifies that electron signal into a measurable pulse. Pulse-height discrimination occurs later in the camera electronics.

  107. Question 107Instrumentation and Image Production (including PET and CT)

    Why is the NaI(Tl) crystal in a gamma camera hermetically sealed?

    1. It becomes more sensitive at high humidity
    2. It emits light only when cooled below zero
    3. It is damaged by exposure to visible light
    4. It is hygroscopic and must remain sealed Correct answer.

    Explanation

    Sodium iodide is hygroscopic, so absorbed water degrades light output and eventually damages the crystal. The crystal is therefore enclosed in a light-tight, moisture-tight housing. Cooling is not required for normal operation.

  108. Question 108Instrumentation and Image Production (including PET and CT)

    What is the main benefit of automatic tube current modulation in CT?

    1. It removes beam-hardening artifacts completely
    2. It increases the reconstructed slice thickness
    3. It shortens the reconstruction time
    4. It lowers dose while controlling noise Correct answer.

    Explanation

    Tube current modulation adjusts mA according to patient attenuation along the scan. Less mA is used where fewer photons are needed, reducing dose while keeping noise acceptable. It does not eliminate beam hardening or change slice thickness.

  109. Question 109Instrumentation and Image Production (including PET and CT)

    On a CT display, what does the window level control?

    1. The amount of noise removed during reconstruction
    2. The spatial resolution of the displayed image
    3. The range of CT numbers mapped to gray levels
    4. The CT number displayed as mid-gray Correct answer.

    Explanation

    Window level sets the center CT number of the displayed gray-scale range. Window width sets the range around that center. Changing level shifts brightness up or down without changing the width.

  110. Question 110Instrumentation and Image Production (including PET and CT)

    What is the purpose of the energy window in a gamma camera?

    1. Reject photons that have lost energy by scattering Correct answer.
    2. Improve the spatial linearity of the detector
    3. Increase the sensitivity of the photomultiplier tube
    4. Shorten the decay time of the scintillation crystal

    Explanation

    Scattered photons deposit less than the full photopeak energy. The pulse-height analyzer accepts events within a window around the photopeak, so most scattered events are rejected. This improves contrast at some cost in sensitivity.

  111. Question 111Instrumentation and Image Production (including PET and CT)

    Increasing the septal thickness of a parallel-hole collimator will generally:

    1. Increase both spatial resolution and sensitivity
    2. Improve energy resolution without changing sensitivity
    3. Reduce septal penetration but lower sensitivity Correct answer.
    4. Raise sensitivity and reduce septal penetration

    Explanation

    Thicker septa absorb more oblique photons that would otherwise penetrate between holes. This reduces septal penetration and improves contrast, but it also decreases the open area and therefore lowers sensitivity.

  112. Question 112Instrumentation and Image Production (including PET and CT)

    Beam hardening in CT is caused by:

    1. Selective loss of low-energy x-rays Correct answer.
    2. Patient motion during the scan
    3. Detector afterglow between rotations
    4. Photon starvation in a very dense region

    Explanation

    A polychromatic x-ray beam becomes relatively higher in average energy as low-energy photons are preferentially absorbed. This shift produces cupping and dark streaks. Filtration, calibration, and correction algorithms reduce the effect.

  113. Question 113Instrumentation and Image Production (including PET and CT)

    How does choosing a sharp CT reconstruction kernel instead of a soft kernel affect the image?

    1. A soft kernel reduces noise and improves detail
    2. A sharp kernel reduces image noise and improves contrast
    3. A sharp kernel improves resolution but raises noise Correct answer.
    4. A soft kernel increases spatial resolution

    Explanation

    Sharp kernels emphasize high spatial frequencies, which improves edge detail and spatial resolution but also amplifies noise. Soft kernels smooth the image, reducing noise while blurring fine detail.

  114. Question 114Instrumentation and Image Production (including PET and CT)

    In PET, the coincidence timing window determines:

    1. The energy threshold applied to each detector
    2. The attenuation correction factor for the patient
    3. The reconstructed voxel size
    4. The maximum allowed detector time difference Correct answer.

    Explanation

    A coincidence is recorded when two detectors fire within a short timing window. The window must be wide enough to accept true events but narrow enough to limit random coincidences. Energy thresholds and attenuation correction are handled separately.

  115. Question 115Instrumentation and Image Production (including PET and CT)

    Compared with 2D PET acquisition, 3D PET acquisition typically:

    1. Removes the need for attenuation correction
    2. Raises sensitivity and increases scatter Correct answer.
    3. Improves timing resolution markedly
    4. Reduces scatter and random coincidences

    Explanation

    3D mode accepts oblique lines of response without interplane septa, increasing sensitivity. The larger accepted solid angle also admits more scattered and random coincidences, so correction is more demanding.

  116. Question 116Instrumentation and Image Production (including PET and CT)

    In SPECT reconstruction, raising the cutoff frequency of a Butterworth filter will:

    1. Lower noise without blurring detail
    2. Remove the need for attenuation correction
    3. Preserve detail but increase noise Correct answer.
    4. Smooth the image and lower noise

    Explanation

    The cutoff sets where the filter begins to suppress high spatial frequencies. A higher cutoff retains more high-frequency detail but also admits more noise. The order controls the steepness of the rolloff.

  117. Question 117Instrumentation and Image Production (including PET and CT)

    How does CT image noise change when mAs is increased?

    1. It increases in direct proportion to mAs
    2. It increases with the square of mAs
    3. It remains independent of the mAs value
    4. It falls with the square root of mAs Correct answer.

    Explanation

    CT noise arises from statistical variation in detected photons. Because photon number is proportional to mAs, noise is approximately inversely proportional to the square root of mAs. Doubling mAs reduces noise by about 40%.

  118. Question 118Instrumentation and Image Production (including PET and CT)

    Which factors limit PET spatial resolution even with a perfect detector?

    1. Positron range and non-colinearity Correct answer.
    2. Random coincidence subtraction
    3. CT attenuation correction errors
    4. Photoelectric absorption in the detector crystal

    Explanation

    A positron travels a short distance before annihilating, so the annihilation site differs from the decay site. The two 511-keV photons are also not exactly 180 degrees apart because of residual momentum. Both effects blur the measured line of response.

  119. Question 119Instrumentation and Image Production (including PET and CT)

    Photon starvation artifact in CT is most directly caused by:

    1. Uniform x-ray attenuation across the field
    2. Too few photons through dense tissue Correct answer.
    3. Increased photon flux through a dense region
    4. Excessive detector sampling in the z-axis

    Explanation

    When a very dense or large body region attenuates nearly all photons, detectors receive very few counts. The resulting high noise and missing projections create streaks. Automatic exposure control and iterative reconstruction can help reduce it.

  120. Question 120Instrumentation and Image Production (including PET and CT)

    What does a PET normalization scan correct?

    1. CT numbers converted to attenuation coefficients
    2. Detector efficiency across the ring Correct answer.
    3. Patient motion between PET and CT
    4. Scattered photons in the patient

    Explanation

    Normalization accounts for differences in detector gain, crystal light output, and geometry around the PET ring. It ensures that identical activity produces similar signals in all lines of response. Scatter and attenuation corrections are separate processes.

  121. Question 121Radiation Safety and Protection

    What is the NRC annual total effective dose equivalent limit for an adult occupational radiation worker?

    1. 500 mSv (50 rem)
    2. 5 mSv (0.5 rem)
    3. 150 mSv (15 rem)
    4. 50 mSv (5 rem) Correct answer.

    Explanation

    Under 10 CFR 20.1201 the annual total effective dose equivalent limit for an adult radiation worker is 50 mSv (5 rem). Separate, higher limits apply to the lens of the eye and to the skin and extremities.

  122. Question 122Radiation Safety and Protection

    Under NRC regulations, the annual occupational dose limit to the lens of the eye is:

    1. 500 mSv (50 rem)
    2. 50 mSv (5 rem)
    3. 150 mSv (15 rem) Correct answer.
    4. 20 mSv (2 rem)

    Explanation

    10 CFR 20.1201 sets the annual lens-of-eye limit for occupationally exposed adults at 150 mSv (15 rem). The lower 20 mSv value is an ICRP recommendation, not the NRC regulatory limit.

  123. Question 123Radiation Safety and Protection

    The annual effective dose limit for an individual member of the public from the operation of a licensed radioactive materials facility is:

    1. 50 mSv (5 rem)
    2. 5 mSv (500 mrem)
    3. 1 mSv (100 mrem) Correct answer.
    4. 0.1 mSv (10 mrem)

    Explanation

    10 CFR 20.1301 limits the total effective dose equivalent to a member of the public from licensed operations to 1 mSv (100 mrem) in a year. The limit applies to dose received in unrestricted areas.

  124. Question 124Radiation Safety and Protection

    The dose limit to the embryo/fetus of a declared pregnant worker over the entire gestation period is:

    1. 1 mSv (100 mrem)
    2. 0.5 mSv (50 mrem)
    3. 5 mSv (0.5 rem) Correct answer.
    4. 15 mSv (1.5 rem)

    Explanation

    10 CFR 20.1208 limits the dose to the embryo/fetus of a declared pregnant worker to 5 mSv (0.5 rem) for the full gestation period. The licensee must also make efforts to avoid a substantial monthly variation above 0.5 mSv.

  125. Question 125Radiation Safety and Protection

    How should a ring badge be worn by a technologist who handles radiopharmaceuticals?

    1. Clipped to the collar, outside the lead apron
    2. On the non-dominant hand, with the detector facing away from the palm
    3. On the dominant hand, with the detector facing the palm side Correct answer.
    4. On the wrist of the hand that holds the syringe

    Explanation

    The extremity badge is worn on the hand likely to receive the highest dose, usually the dominant hand that holds the syringe, with the detecting element on the palm side. The palm faces the source during shielding and handling, so it receives the greatest exposure.

  126. Question 126Radiation Safety and Protection

    The three basic principles used to reduce occupational radiation exposure are:

    1. Time, distance, and shielding Correct answer.
    2. Collimation, filtration, and beam restriction
    3. Respirators, gloves, and shoe covers
    4. Shielding, decay, and dispersion

    Explanation

    Dose is reduced by limiting the time spent near a source, increasing the distance from it, and interposing appropriate shielding. These three controls form the practical basis of the ALARA program.

  127. Question 127Radiation Safety and Protection

    Which posting is required on a room where only radioactive materials are stored or used?

    1. Caution: High Voltage
    2. Caution: X-Ray in Use
    3. Biohazard
    4. Caution: Radioactive Material Correct answer.

    Explanation

    10 CFR 20.1902 requires the standard radiation symbol with the words 'Caution - Radioactive Material' (or 'Caution - Radiation Area' where applicable) at access points to areas where licensed material is used or stored. The posting warns of the specific hazard present.

  128. Question 128Radiation Safety and Protection

    Which instrument is most appropriate for surveying benchtops for removable Tc-99m contamination?

    1. Dose calibrator
    2. Geiger-Mueller survey meter with a thin-window probe Correct answer.
    3. Thyroid uptake probe
    4. Gamma camera with a parallel-hole collimator

    Explanation

    A thin-window Geiger-Mueller probe detects beta particles and low-energy photons and is the standard tool for wipe tests and surface contamination surveys. The thin window allows low-energy emissions to reach the detector.

  129. Question 129Radiation Safety and Protection

    The half-value layer of an absorbing material is best defined as the thickness that:

    1. Reduces photon intensity to one-half of its original value Correct answer.
    2. Reduces scattered radiation to 1% of the incident beam
    3. Doubles the attenuation coefficient for each centimeter
    4. Reduces the beam to one-tenth of its original intensity

    Explanation

    The half-value layer is the thickness of a specified material that attenuates a narrow beam of photons to half of its incident intensity. Each additional half-value layer halves the remaining intensity.

  130. Question 130Radiation Safety and Protection

    A technologist wears a 0.5 mm Pb-equivalent apron while injecting Tc-99m. Which practice is correct?

    1. Removing the apron whenever working at distances greater than 1 meter
    2. Wearing the whole-body dosimeter beneath the apron to record the shielded dose
    3. Omitting the whole-body dosimeter because the apron blocks essentially all photons
    4. Wearing the whole-body dosimeter at collar level outside the apron and still using time and distance to limit dose Correct answer.

    Explanation

    Half-value layers of lead attenuate but do not eliminate 140 keV photons, so an apron reduces dose without removing the need for monitoring or for time and distance control. The whole-body badge is worn outside the apron at collar level so that the unshielded head and neck dose is captured.

  131. Question 131Radiation Safety and Protection

    Which personnel dosimeter uses aluminum oxide detectors and can be re-read without destroying the stored signal?

    1. Pocket ionization chamber
    2. Thermoluminescent badge
    3. Film badge
    4. Optically stimulated luminescence badge Correct answer.

    Explanation

    An optically stimulated luminescence badge stores energy in aluminum oxide and releases it as light when stimulated by a laser, leaving the latent signal available for re-reading. Readout is therefore non-destructive and repeatable.

  132. Question 132Radiation Safety and Protection

    A package labeled Radioactive White-I may have a maximum radiation level at its external surface of:

    1. 50 mrem/h (0.5 mSv/h)
    2. 0.05 mrem/h (0.5 µSv/h)
    3. 200 mrem/h (2 mSv/h)
    4. 0.5 mrem/h (5 µSv/h) Correct answer.

    Explanation

    A White-I package must have a surface dose rate no greater than 0.5 mrem/h (5 µSv/h) and a transport index of zero. Yellow-II packages may reach 50 mrem/h and Yellow-III packages 200 mrem/h at the surface.

  133. Question 133Radiation Safety and Protection

    A sealed-source leak test is considered positive when removable activity on the wipe exceeds:

    1. 0.005 µCi (185 Bq) Correct answer.
    2. 50 µCi (1.85 MBq)
    3. 5 µCi (185 kBq)
    4. 0.5 µCi (18.5 kBq)

    Explanation

    The regulatory threshold is 0.005 µCi (185 Bq) of removable activity on the test wipe; exceeding it requires the source to be removed from service and reported. Leak tests are performed at intervals not exceeding six months.

  134. Question 134Radiation Safety and Protection

    Under compendial and regulatory limits, the maximum Mo-99 contamination permitted in eluted Tc-99m is:

    1. 0.015 kBq Mo-99 per MBq Tc-99m (0.015 µCi per mCi)
    2. 1.5 kBq Mo-99 per MBq Tc-99m (1.5 µCi per mCi)
    3. 15 kBq Mo-99 per MBq Tc-99m (15 µCi per mCi)
    4. 0.15 kBq Mo-99 per MBq Tc-99m (0.15 µCi per mCi) Correct answer.

    Explanation

    The limit for molybdenum breakthrough is 0.15 kBq of Mo-99 per MBq of Tc-99m, equivalent to 0.15 µCi per mCi. Eluates are tested before administration because Mo-99 has a long half-life and delivers unnecessary dose.

  135. Question 135Radiation Safety and Protection

    Waste containing only short-lived radionuclides may be disposed of as non-radioactive after decay in storage when:

    1. ten half-lives have elapsed and a survey shows radiation levels indistinguishable from background Correct answer.
    2. the waste has been sealed in a lead-lined container
    3. three half-lives have elapsed, regardless of survey results
    4. one half-life has elapsed

    Explanation

    Decay-in-storage disposal requires that the waste be held long enough for the activity to decay, conventionally at least ten half-lives, and that a survey confirm residual activity is indistinguishable from background. Records of the holding period and survey must be kept.

  136. Question 136Radiation Safety and Protection

    A vial of Tc-99m liquid breaks on the hot-lab floor. What is the most appropriate first response?

    1. Evacuate the room and re-enter after one half-life has elapsed
    2. Alert others, restrict the area, and check people and surfaces for contamination Correct answer.
    3. Wipe the spill with absorbent pads and place the pads in the regular trash
    4. Cover the spill with a lead shield and resume work

    Explanation

    Spill response begins with notification, confinement of the area, and contamination checks so that the spread of material is controlled and exposed persons are identified. Cleanup, shielding, and documentation follow once the area is secured.

  137. Question 137Radiation Safety and Protection

    Which dose calibrator test is performed on each day of use to confirm that the instrument's response has not drifted?

    1. Constancy Correct answer.
    2. Geometry
    3. Linearity
    4. Accuracy

    Explanation

    The constancy test is performed daily with a long-lived reference source such as Cs-137 or Co-57 and must agree with the established value within the accepted tolerance, typically 10%. Linearity, geometry, and accuracy are less frequent performance checks.

  138. Question 138Radiation Safety and Protection

    Under 10 CFR 35.75, a patient may be released without further delay if the measured dose rate at 1 meter is no greater than:

    1. 700 mrem/h (7 mSv/h)
    2. 0.7 mrem/h (7 µSv/h)
    3. 70 mrem/h (0.7 mSv/h)
    4. 7 mrem/h (70 µSv/h) Correct answer.

    Explanation

    Release is permitted when the dose rate at 1 meter is 7 mrem/h (0.07 mSv/h) or less, or when the administered activity is at or below the specified limit, or when the calculated dose to any other individual would not exceed 5 mSv. Written instructions are provided when release relies on dose to others.

  139. Question 139Radiation Safety and Protection

    A technologist accidentally inhales I-131 vapor. Which measurement best quantifies the internal contamination?

    1. A thyroid count with a scintillation detector Correct answer.
    2. A whole-body OSL badge reading
    3. A survey of the shoe soles with a Geiger-Mueller meter
    4. A wipe test of the hands

    Explanation

    Inhaled iodine is concentrated in the thyroid, so a direct thyroid count with a scintillation detector provides the most sensitive and specific measure of intake. Hand wipes and shoe surveys assess external contamination only, and a badge records external dose.

  140. Question 140Radiation Safety and Protection

    After a patient receives I-131 for thyroid ablation, breastfeeding should be:

    1. interrupted for 24 hours
    2. continued without restriction
    3. interrupted for 2 weeks
    4. discontinued Correct answer.

    Explanation

    Iodine-131 is excreted in breast milk and concentrates in the infant thyroid, so breastfeeding must be permanently discontinued after therapeutic iodine administration. A temporary interruption is not sufficient for therapy doses.

  141. Question 141Radiation Safety and Protection

    The exposure rate at 1 meter from a point source is 40 mR/h. Ignoring attenuation, what is the exposure rate at 4 meters?

    1. 5 mR/h
    2. 0.25 mR/h
    3. 2.5 mR/h Correct answer.
    4. 10 mR/h

    Explanation

    Exposure rate from a point source varies inversely with the square of the distance, so quadrupling the distance reduces the rate by a factor of 16. Dividing 40 mR/h by 16 gives 2.5 mR/h.

  142. Question 142Radiation Safety and Protection

    A material has a half-value layer of 0.3 mm Pb at 140 keV. What thickness reduces the photon intensity to one-sixteenth of its original value?

    1. 1.2 mm Pb Correct answer.
    2. 0.6 mm Pb
    3. 2.4 mm Pb
    4. 0.9 mm Pb

    Explanation

    Reducing intensity to one-sixteenth requires four half-value layers because 2 raised to the fourth power equals 16. Multiplying four by 0.3 mm Pb gives 1.2 mm Pb.

  143. Question 143Radiation Safety and Protection

    A vial contains 925 MBq of Tc-99m (physical half-life 6 hours) at 8:00 a.m. What activity remains at 8:00 a.m. the next day, 24 hours later?

    1. about 231 MBq
    2. about 116 MBq
    3. about 58 MBq Correct answer.
    4. about 463 MBq

    Explanation

    Twenty-four hours equals four half-lives of Tc-99m, so the activity is divided by 2 raised to the fourth power, or 16. Dividing 925 MBq by 16 gives approximately 58 MBq.

  144. Question 144Radiation Safety and Protection

    A radiopharmaceutical has a physical half-life of 6 hours and a biologic half-life of 12 hours. Its effective half-life is:

    1. 9 hours
    2. 4 hours Correct answer.
    3. 3 hours
    4. 18 hours

    Explanation

    Effective half-life is obtained from the reciprocal relationship 1/Te = 1/Tp + 1/Tb, which here gives 1/6 + 1/12 = 3/12. Inverting yields an effective half-life of 4 hours, always shorter than either component.

  145. Question 145Radiation Safety and Protection

    A technologist spends 2 minutes per patient at 0.5 meter and performs 15 studies each day. Which single change would most reduce occupational dose?

    1. Using a syringe shield during injections
    2. Halving the time spent with each patient
    3. Wearing a 0.25 mm Pb-equivalent apron
    4. Stepping back to 1 meter from each patient Correct answer.

    Explanation

    Doubling the distance from a patient reduces exposure by a factor of four through the inverse square law, a larger reduction than halving time (a factor of two). A 0.25 mm Pb apron attenuates only part of the 140 keV photons and a syringe shield protects only during the injection itself.

  146. Question 146Radiation Safety and Protection

    What is the NRC annual limit for total effective dose equivalent to an occupationally exposed adult radiation worker?

    1. 150 mSv (15 rem) per year
    2. 500 mSv (50 rem) per year
    3. 50 mSv (5 rem) per year Correct answer.
    4. 5 mSv (0.5 rem) per year

    Explanation

    The annual limit for total effective dose equivalent is 50 mSv (5 rem). Separate, higher limits apply to individual organs: 150 mSv for the lens of the eye and 500 mSv for skin, hands, and forearms. The 5 mSv figure is closer to the public and gestational limits, not the occupational whole-body limit.

  147. Question 147Radiation Safety and Protection

    What is the annual effective dose limit for a member of the public from all licensed operations of a nuclear medicine facility?

    1. 0.1 mSv (10 mrem) in a year
    2. 1 mSv (100 mrem) in a year Correct answer.
    3. 50 mSv (5 rem) in a year
    4. 5 mSv (500 mrem) in a year

    Explanation

    NRC rules limit the total effective dose equivalent to any member of the public to 1 mSv (100 mrem) per year from licensed operations. The 50 mSv value is the occupational limit, and 5 mSv is the gestational limit for a declared pregnant worker. The 0.1 mSv figure applies only to the airborne effluent pathway, not to all pathways combined.

  148. Question 148Radiation Safety and Protection

    An accessible area must be posted as a Radiation Area when the dose rate there exceeds which value?

    1. 2 mrem/h at 30 cm
    2. 5 mrem/h at 30 cm Correct answer.
    3. 5 mrem/h at 1 m
    4. 1 mrem/h at 30 cm

    Explanation

    A radiation area is an accessible area where the dose rate exceeds 5 mrem (0.05 mSv) in any one hour at 30 cm from the source or from any surface the radiation penetrates. At 100 mrem/h at 30 cm the area becomes a high radiation area. Lower rates, such as 1 or 2 mrem/h, do not require this posting.

  149. Question 149Radiation Safety and Protection

    For a declared pregnant worker, what fetal dose limit applies under NRC regulations?

    1. 5 mSv (500 mrem) in any one month
    2. 0.5 mSv (50 mrem) in any one month Correct answer.
    3. 10 mSv (1 rem) over the gestation period
    4. 1 mSv (100 mrem) in any one month

    Explanation

    The declared pregnant worker limits are 0.5 mSv (50 mrem) in any one month and 5 mSv (500 mrem) over the entire gestation period. These limits apply only after the worker voluntarily declares the pregnancy in writing. The goal is to keep fetal dose as low as reasonably achievable.

  150. Question 150Radiation Safety and Protection

    What is the annual dose equivalent limit for the hands and forearms of an occupationally exposed radiation worker?

    1. 500 mSv (50 rem) per year Correct answer.
    2. 15 mSv (1.5 rem) per year
    3. 50 mSv (5 rem) per year
    4. 150 mSv (15 rem) per year

    Explanation

    The annual limit for the extremities (hands and forearms) and for skin is 500 mSv (50 rem). Ring badges are used because hand dose during radiopharmaceutical preparation can greatly exceed whole-body dose. The 150 mSv value is the lens-of-eye limit and 50 mSv is the whole-body effective dose limit.

  151. Question 151Radiation Safety and Protection

    Under NRC rules, personnel monitoring must be provided when an individual is likely to receive more than what fraction of the annual occupational dose limit?

    1. 1% of the annual limit
    2. 50% of the annual limit
    3. 25% of the annual limit
    4. 10% of the annual limit Correct answer.

    Explanation

    Monitoring is required when an individual is likely to receive more than 10% of the applicable annual limit, such as more than 5 mSv to the whole body. Below that threshold, monitoring is not mandated, though it may still be provided. This is why technologists who routinely handle diagnostic and therapeutic activities wear whole-body badges.

  152. Question 152Radiation Safety and Protection

    Why is tungsten often preferred over lead for syringe shields used with F-18 FDG?

    1. Tungsten shields are mandated for PET by regulation
    2. Tungsten completely absorbs all annihilation photons
    3. Tungsten has greater density and attenuates 511 keV better Correct answer.
    4. Lead is prohibited for shielding positron-emitting radionuclides

    Explanation

    At 511 keV the photoelectric effect is small in lead, so attenuation depends mainly on density and electron density. Tungsten's higher density (about 19.3 versus 11.3 g/cm3) gives more attenuation per unit thickness, which matters for a compact syringe shield. No regulation specifies a shielding material; rules set dose limits instead.

  153. Question 153Radiation Safety and Protection

    Where should a ring badge be worn during radiopharmaceutical preparation?

    1. On the wrist of the arm used least during the procedure
    2. On the hand receiving the highest dose, label facing the source Correct answer.
    3. Clipped to the collar outside the lead apron
    4. On the dominant hand, with the label facing away from the source

    Explanation

    The ring badge belongs on the hand likely to receive the greatest dose, with the detector window facing the source so it records the dose actually delivered. Hands typically receive far more dose than the torso during vial handling and dose drawing. A collar badge monitors the head and neck and is a separate dosimeter.

  154. Question 154Radiation Safety and Protection

    What face velocity is typically required for a radiopharmacy fume hood used with volatile radionuclides such as I-131?

    1. 250 linear feet per minute
    2. 500 linear feet per minute
    3. 100 linear feet per minute Correct answer.
    4. 25 linear feet per minute

    Explanation

    About 100 linear feet per minute (roughly 0.5 m/s) is the standard face velocity for a fume hood handling volatile radioactive material. This airflow is sufficient to capture iodine vapor and keep it from escaping into the room. Velocities far below that allow escape, while excessively high velocities create turbulence that can reduce containment.

  155. Question 155Radiation Safety and Protection

    A technologist must measure the exposure rate at 1 meter from a patient who recently received 7.4 GBq of I-131. Which instrument is appropriate?

    1. A dose calibrator with a syringe holder
    2. A thin-window GM survey meter
    3. An ionization chamber survey meter Correct answer.
    4. A well counter with a NaI crystal

    Explanation

    Ionization chamber survey meters have a wide range, are relatively energy independent, and do not saturate at the exposure rates found near therapy patients, so they are used for dose-rate surveys and release measurements. GM meters are intended for low-level contamination surveys and may saturate or overrespond at high rates. Well counters and dose calibrators measure activity in samples or vials, not free-field exposure rate.

  156. Question 156Radiation Safety and Protection

    Which instruction is appropriate for a patient released after I-131 thyroid ablation?

    1. Stop all fluid intake to reduce urinary excretion
    2. Share eating utensils without special washing
    3. Sleep apart and maintain distance for the advised period Correct answer.
    4. Return to normal close-contact activities immediately

    Explanation

    Released patients receive written instructions to limit close contact, sleep in a separate bed, avoid prolonged holding of children, and flush the toilet twice after use for a period based on administered activity. These steps reduce dose to household members and the public. Fluids should be encouraged rather than restricted, because frequent voiding lowers bladder dose and external exposure.

  157. Question 157Radiation Safety and Protection

    An area must be posted as an Airborne Radioactivity Area when airborne concentrations of radioactive material exceed which level? (DAC = derived air concentration)

    1. Ten times the DAC
    2. One-half of the DAC
    3. One-tenth of the DAC
    4. The DAC itself Correct answer.

    Explanation

    The definition is met when airborne concentrations exceed the DAC, or when a person without respiratory protection could exceed 12 DAC-hours in a week (0.6% of the ALI). Posting warns workers that air monitoring and respiratory protection may be needed. Concentrations below the DAC do not require this posting.

  158. Question 158Radiation Safety and Protection

    A vial of Sr-89 chloride, a high-energy beta emitter, must be shielded. Which approach is correct?

    1. Put acrylic closest to the source to absorb the betas Correct answer.
    2. Wrap the vial in a single layer of aluminum foil
    3. Put lead closest to the source to absorb the betas
    4. No shielding is needed because Sr-89 is a pure beta emitter

    Explanation

    High-energy beta particles crossing high-Z material such as lead generate bremsstrahlung x-rays, so a low-Z absorber like acrylic (about 1 cm) is placed next to the source to stop the betas, with lead added outside if needed for the residual photons. Aluminum foil is far thinner than the range of a 1.5 MeV beta particle. Pure beta emitters still require shielding because of bremsstrahlung and direct skin and lens dose.

  159. Question 159Radiation Safety and Protection

    The exposure rate at 1 meter from a source is 0.12 mSv/h. What is the maximum time a technologist may remain at 1 meter while keeping the dose at or below 0.03 mSv?

    1. 5 minutes
    2. 30 minutes
    3. 15 minutes Correct answer.
    4. 60 minutes

    Explanation

    Time equals dose divided by dose rate: 0.03 mSv divided by 0.12 mSv/h equals 0.25 hour, or 15 minutes. Staying longer would exceed the stated dose budget, and shorter times would unnecessarily limit the work. This is the time component of the time-distance-shielding approach to ALARA.

  160. Question 160Radiation Safety and Protection

    Which term describes the sum of the deep-dose equivalent from external exposure and the committed effective dose equivalent from an intake of radioactive material?

    1. Ambient dose equivalent
    2. Collective effective dose equivalent
    3. Committed dose equivalent
    4. Total effective dose equivalent Correct answer.

    Explanation

    The total effective dose equivalent combines the external deep-dose equivalent with the committed effective dose equivalent from internal deposition. It is the quantity compared with the 50 mSv annual occupational limit. Committed dose equivalent refers to the dose to a specific tissue from an intake over 50 years.

  161. Question 161Patient Care and Quality Control

    Before administering a radiopharmaceutical, which practice best confirms correct patient identification?

    1. Checking that the patient's name matches the requisition alone
    2. Confirming the patient's room number with the nursing staff
    3. Two independent identifiers such as name and date of birth Correct answer.
    4. Verifying the patient's age and weight

    Explanation

    Identification requires at least two independent identifiers, typically full name plus date of birth, checked against the requisition and the patient's armband before any radiopharmaceutical is given. Location-based identifiers are unreliable because patients are moved and reassigned.

  162. Question 162Patient Care and Quality Control

    Which quality control test is performed daily on a dose calibrator?

    1. Constancy Correct answer.
    2. Geometry
    3. Accuracy
    4. Linearity

    Explanation

    Constancy is checked with a sealed source each day the calibrator is used to confirm the instrument response has not drifted, and a deviation beyond the tolerance requires investigation. Linearity is performed quarterly, while accuracy and geometry are evaluated at installation and after repair.

  163. Question 163Patient Care and Quality Control

    The accuracy of a dose calibrator must agree with the true activity within what tolerance?

    1. ±20%
    2. ±10%
    3. ±5% Correct answer.
    4. ±2%

    Explanation

    The accuracy test compares the calibrator reading against a calibrated standard or reference source, and the reading must agree within 5 percent. A larger discrepancy means the instrument must be adjusted or repaired before patient doses are assayed.

  164. Question 164Patient Care and Quality Control

    A daily flood image of a gamma camera detector is used primarily to evaluate which parameter?

    1. Spatial resolution
    2. Field uniformity Correct answer.
    3. Sensitivity
    4. Energy resolution

    Explanation

    A flood image reveals non-uniform detector response such as a drifting photomultiplier tube, and the integral and differential uniformity values must fall within established limits. Resolution, sensitivity, and energy resolution are assessed with other phantoms or measurements.

  165. Question 165Patient Care and Quality Control

    According to the ALARA principle, moving from 1 meter to 2 meters away from an unshielded point source changes the exposure rate by a factor of:

    1. Eight
    2. Four Correct answer.
    3. Three
    4. Two

    Explanation

    Exposure rate from a point source follows the inverse-square law, so doubling the distance reduces the exposure rate to one quarter of its original value. Distance is one of the most effective tools for reducing occupational dose.

  166. Question 166Patient Care and Quality Control

    Which question is most important to ask a female patient of childbearing age before a nuclear medicine procedure?

    1. Whether she has any allergies to shellfish or iodine
    2. Whether she has eaten in the last hour
    3. Whether she is pregnant or breastfeeding Correct answer.
    4. Whether she has had a prior CT scan

    Explanation

    Pregnancy and lactation status determine whether a study should be postponed, the radiopharmaceutical or activity changed, or breastfeeding interrupted, so this must be asked of every patient of childbearing age. The other questions address issues that are either less critical or irrelevant to radiopharmaceutical risk.

  167. Question 167Patient Care and Quality Control

    The regulatory limit for molybdenum-99 breakthrough in technetium-99m eluate is:

    1. 1.5 µCi Mo-99 per mCi Tc-99m
    2. 0.015 µCi Mo-99 per mCi Tc-99m
    3. 0.15 µCi Mo-99 per mCi Tc-99m Correct answer.
    4. 15 µCi Mo-99 per mCi Tc-99m

    Explanation

    The limit is 0.15 kBq of Mo-99 per MBq of Tc-99m (0.15 µCi per mCi) at the time of administration, because molybdenum-99 decays to technetium-99m and would add an unaccounted patient dose. An eluate exceeding the limit must be discarded.

  168. Question 168Patient Care and Quality Control

    A bar phantom placed on a gamma camera detector is used to assess:

    1. Uniformity
    2. Energy peaking
    3. Spatial resolution Correct answer.
    4. Collimator septal thickness

    Explanation

    Bar phantoms contain bars of decreasing width, and the smallest set of bars that can still be resolved indicates the system's spatial resolution. Uniformity, energy peaking, and septal thickness are evaluated by other means.

  169. Question 169Patient Care and Quality Control

    Dose calibrator linearity must be evaluated at what minimum frequency?

    1. Weekly
    2. Quarterly Correct answer.
    3. Daily
    4. Annually

    Explanation

    Linearity testing verifies that calibrator response remains proportional across the range of activities used clinically and is required at least quarterly. Daily checks address constancy, and accuracy and geometry are assessed at installation and after repair.

  170. Question 170Patient Care and Quality Control

    An extrinsic flood image is acquired with which of the following in place?

    1. A bar phantom on the detector
    2. The energy window widened to 50%
    3. The collimator removed
    4. The collimator attached Correct answer.

    Explanation

    An extrinsic flood is acquired with the collimator in place, so it evaluates the combined uniformity of detector and collimator and better approximates clinical imaging conditions. An intrinsic flood is acquired with the collimator removed.

  171. Question 171Patient Care and Quality Control

    During an intravenous radiopharmaceutical injection the patient reports pain and swelling at the site, and resistance is felt on the plunger. The first action is to:

    1. Continue and apply a warm compress afterward
    2. Massage the site to disperse the dose
    3. Increase the injection pressure to finish quickly
    4. Stop the injection and remove the needle Correct answer.

    Explanation

    Pain, swelling, and resistance indicate that the needle has infiltrated tissue, so the injection must be stopped immediately to limit the extravasated activity. The physician is then notified, the extremity elevated, and the event documented.

  172. Question 172Patient Care and Quality Control

    A patient treated with 3.7 GBq (100 mCi) of iodine-131 for thyroid ablation should be instructed to:

    1. Sleep in the same bed as their spouse but avoid kissing
    2. Prepare food for family members while wearing gloves
    3. Sleep in a separate bed and limit close contact Correct answer.
    4. Return to work the next day without restriction

    Explanation

    Released therapy patients receive written instructions to limit close contact, sleep alone, and avoid prolonged time near children and pregnant women for a specified period so that household doses stay as low as reasonably achievable. Separate bathroom use and double flushing are also commonly advised.

  173. Question 173Patient Care and Quality Control

    After therapy with iodine-131 for thyroid cancer, a breastfeeding mother should:

    1. Stop breastfeeding permanently Correct answer.
    2. Interrupt breastfeeding for 24 hours
    3. Continue breastfeeding with no restriction
    4. Interrupt breastfeeding for 1 week

    Explanation

    Iodine-131 is concentrated and secreted in breast milk and delivers a large thyroid dose to the infant, so breastfeeding must be discontinued permanently after therapeutic iodine-131. Brief interruption is acceptable for many technetium-99m agents but is inadequate here.

  174. Question 174Patient Care and Quality Control

    A patient scheduled for an FDG PET scan has a blood glucose of 250 mg/dL. The most appropriate action is to:

    1. Administer a larger dose of FDG to compensate
    2. Give insulin and scan immediately
    3. Proceed with the scan as scheduled
    4. Reschedule the study after glucose is controlled Correct answer.

    Explanation

    Elevated glucose competes with FDG for cellular uptake and degrades lesion detection, and most protocols require glucose below roughly 150 to 200 mg/dL before injection. Increasing the administered activity does not overcome the competitive effect.

  175. Question 175Patient Care and Quality Control

    A technologist's hand becomes contaminated with technetium-99m pertechnetate. The best decontamination method is to:

    1. Wash with lukewarm water and mild soap Correct answer.
    2. Apply alcohol wipes until the meter reads background
    3. Delay washing for an hour to allow decay
    4. Scrub vigorously with a stiff brush and hot water

    Explanation

    Skin contamination is removed with lukewarm water and mild soap using gentle washing that keeps the skin intact, so activity is not driven into the dermis. Harsh scrubbing, hot water, and solvents increase both absorption and skin damage.

  176. Question 176Patient Care and Quality Control

    Which check should be performed on a survey meter at the start of each working day?

    1. Energy resolution calibration
    2. Linearity testing with a decaying standard source
    3. Geometry check with a syringe
    4. Battery check and response to a check source Correct answer.

    Explanation

    Before use each day the survey meter is checked for battery condition and for a reproducible response to a sealed check source, confirming it is operational and has not drifted. Full calibration is performed at least annually and after repair.

  177. Question 177Patient Care and Quality Control

    The geometry test of a dose calibrator verifies that the measured activity:

    1. Remains constant from day to day
    2. Matches a calibrated standard within 5 percent of the stated activity
    3. Does not vary with sample volume or position in the well Correct answer.
    4. Is linear across the entire activity range

    Explanation

    The geometry test confirms that the reading is independent of sample volume, shape, and position in the well, so syringes, vials, and capsules are all assayed accurately. It is performed at installation and after repairs that affect the chamber.

  178. Question 178Patient Care and Quality Control

    Radiochemical purity of a technetium-99m labeled compound is most commonly determined by:

    1. Chromatography Correct answer.
    2. Membrane filtration sterility testing
    3. Gamma-ray spectroscopy
    4. Limulus amebocyte lysate testing

    Explanation

    Chromatography separates the labeled compound from free pertechnetate and hydrolyzed-reduced technetium so each fraction can be quantified. LAL and sterility testing address microbiological quality rather than chemical form.

  179. Question 179Patient Care and Quality Control

    Which SPECT quality control test evaluates misalignment between the detector and the axis of rotation?

    1. Energy peaking
    2. Center of rotation Correct answer.
    3. Bar phantom resolution
    4. Flood field uniformity

    Explanation

    The center-of-rotation test images point sources at multiple angles to confirm that the mechanical axis of rotation aligns with the center of the reconstruction matrix. Misalignment produces ring artifacts and loss of resolution in reconstructed images.

  180. Question 180Patient Care and Quality Control

    The administered activity for a pediatric nuclear medicine study is most appropriately determined by:

    1. Dividing the adult dose in half for every child
    2. Giving the smallest volume that fits in a syringe
    3. Using the same adult dose for all children
    4. Scaling the adult dose by weight or body surface area Correct answer.

    Explanation

    Pediatric activities are scaled from an adult reference activity using weight or body surface area, often with a minimum activity and a validated pediatric dosage card, to keep dose as low as reasonably achievable while preserving image quality. Arbitrary fractions of an adult dose are not appropriate.

  181. Question 181Patient Care and Quality Control

    The maximum permitted alumina (Al3+) concentration in a technetium-99m eluate is:

    1. 100 µg/mL
    2. 1 µg/mL
    3. 0.15 µg/mL
    4. 10 µg/mL Correct answer.

    Explanation

    Alumina can leach from the generator column into the eluate, and the limit is 10 µg/mL; higher concentrations cause labeling failures and particulate formation. Alumina breakthrough is measured colorimetrically at the first elution and after generator maintenance.

  182. Question 182Patient Care and Quality Control

    Which test is used to detect pyrogens in a radiopharmaceutical preparation?

    1. Gram stain
    2. Limulus amebocyte lysate assay Correct answer.
    3. Membrane filtration sterility test
    4. Paper chromatography

    Explanation

    The limulus amebocyte lysate assay uses horseshoe crab lysate, which clots in the presence of bacterial endotoxin, and it is the standard pyrogen test for radiopharmaceuticals. Gram stain, sterility testing, and chromatography do not detect endotoxin.

  183. Question 183Patient Care and Quality Control

    A patient who received a high-dose radiopharmaceutical therapy dies three days later. Which action is most appropriate?

    1. The body must be cremated within 24 hours by regulation
    2. No special precautions are needed once the patient has died
    3. The body should be embalmed before any survey
    4. Survey the body and inform others of autopsy precautions Correct answer.

    Explanation

    The body remains a radiation source after a therapeutic administration, so radiation safety personnel should survey it and autopsy or cremation staff should be told of precautions such as limiting handling time and controlling fluids. Precautions do not expire at death.

  184. Question 184Patient Care and Quality Control

    A dose calibrator constancy check with a cesium-137 source reads 15 percent higher than the established reference value. The appropriate response is to:

    1. Take the calibrator out of service and investigate Correct answer.
    2. Continue in use since the reading is within 20 percent
    3. Adjust the display to match the reference value
    4. Repeat the check with a different radionuclide and ignore the result

    Explanation

    A constancy result that differs from the reference value by more than 10 percent exceeds the acceptance limit, so the instrument is removed from service, the cause is investigated, and it is recalibrated and retested before use. Forcing the display to agree masks the underlying fault.

  185. Question 185Patient Care and Quality Control

    Compared with a low-energy high-resolution collimator, a low-energy all-purpose collimator will:

    1. Decrease both sensitivity and resolution
    2. Increase both sensitivity and resolution
    3. Increase sensitivity and degrade resolution Correct answer.
    4. Decrease sensitivity while improving spatial resolution

    Explanation

    All-purpose collimators have larger holes and thinner septa, so a greater fraction of photons reaches the crystal, raising sensitivity while allowing more septal penetration and poorer spatial resolution. Resolution and sensitivity trade off against each other in collimator design.

  186. Question 186Patient Care and Quality Control

    A ring badge worn by a technologist who prepares and injects radiopharmaceuticals is used to monitor the radiation dose to the:

    1. hands and fingers Correct answer.
    2. whole body
    3. lens of the eye
    4. thyroid gland

    Explanation

    Extremity dosimeters are worn on the hand because the fingers receive the highest dose during vial handling, unit-dose preparation, and injection. The ring is worn with the detector facing the source side of the hand and is exchanged on the same schedule as the body badge.

  187. Question 187Patient Care and Quality Control

    Which action most effectively reduces a technologist's exposure while caring for a patient who has just received 5.55 GBq (150 mCi) of iodine-131?

    1. Moving farther from the patient Correct answer.
    2. Adding a second apron layer
    3. Limiting the number of patient contacts
    4. Wearing a second body badge

    Explanation

    Exposure rate falls with the inverse square of distance, so a small increase in separation lowers dose far more than any practical amount of shielding, especially for the 364 keV photons of iodine-131 that readily penetrate lead aprons. Additional badges only measure dose and do not reduce it.

  188. Question 188Patient Care and Quality Control

    After an intravenous radiopharmaceutical injection, the used needle and syringe are best placed directly into:

    1. a shielded lead storage container
    2. a shielded decay cabinet
    3. a puncture-resistant sharps box Correct answer.
    4. a sealed biohazard waste bag

    Explanation

    Sharps must be deposited into a rigid, puncture-resistant container at the point of use to prevent needlestick injuries, and the container is labeled for radioactive and biohazardous contents. Residual activity is then handled by decay-in-storage or waste disposal as permitted by the license.

  189. Question 189Patient Care and Quality Control

    Which pair of identifiers is acceptable for confirming a patient's identity before radiopharmaceutical administration?

    1. Room number and study ordered
    2. Appointment time and bed number
    3. Name and date of birth Correct answer.
    4. Age and referring physician

    Explanation

    Two independent identifiers assigned to the patient, such as full name plus date of birth or medical record number, must be matched against the requisition and the wristband. Location-based details can change and do not uniquely identify a person.

  190. Question 190Patient Care and Quality Control

    A patient scheduled for a radioiodine thyroid uptake study reports daily use of a kelp supplement. The appropriate action is to:

    1. increase the administered iodine-123 activity
    2. perform the study as scheduled and note the finding
    3. give potassium iodide before the tracer
    4. reschedule after the supplement is stopped Correct answer.

    Explanation

    Kelp is a rich source of stable iodine, which expands the body's iodine pool and competitively blocks thyroid uptake, producing a falsely low result. Iodine-containing supplements and medications must be withheld for an appropriate interval, often one to two weeks, before the study is repeated.

  191. Question 191Patient Care and Quality Control

    Furosemide is administered during a renal scan primarily to:

    1. separate obstruction from pelvic stasis Correct answer.
    2. measure glomerular filtration rate
    3. prevent reflux of tracer into the bladder
    4. increase renal blood flow

    Explanation

    A loop diuretic challenges a dilated collecting system: rapid washout indicates a dilated but unobstructed pelvis, whereas retained activity suggests true obstruction. The timing of the dose relative to tracer injection is set by the protocol so that the challenge occurs during the acquisition.

  192. Question 192Patient Care and Quality Control

    The accuracy of a dose calibrator is verified with:

    1. the daily flood image from the camera
    2. a standard source traceable to NIST Correct answer.
    3. a patient eluate sample counted in a well counter
    4. a check source of undocumented activity

    Explanation

    Accuracy means the displayed activity matches the true activity, which requires a standard source of known activity traceable to a national standard, commonly cobalt-57 or cesium-137. The test is performed at installation and annually thereafter, with the reading required to fall within the accepted tolerance of the standard's value.

  193. Question 193Patient Care and Quality Control

    A portable survey meter used for routine radiation surveys should be calibrated:

    1. monthly by the radiation safety officer
    2. weekly by the staff technologist
    3. annually and after any repair Correct answer.
    4. before each use with a check source

    Explanation

    Instruments used for radiation surveys are calibrated on an annual basis and after any repair or adjustment, with the calibration traceable to a national standard and performed by a qualified individual. The pre-use check with a check source verifies operation and battery status but does not replace calibration.

  194. Question 194Patient Care and Quality Control

    A vial of technetium-99m eluate shatters on the hot-lab floor. The first action is to:

    1. vacuum the spill and bag the filter
    2. mop the area and discard the mop
    3. confine the spill with absorbent material Correct answer.
    4. evacuate the department and call the fire department

    Explanation

    Spill response begins by containing the material to limit its spread and marking the area to keep personnel out, after which the area is surveyed and decontaminated from the outer edge inward with the radiation safety officer notified. Wet methods that spread liquid or generate aerosols are avoided.

  195. Question 195Patient Care and Quality Control

    Daily constancy of a thyroid uptake probe is best verified with:

    1. the previous day's patient background count
    2. a long-lived standard in a fixed geometry Correct answer.
    3. an iodine-131 capsule at one meter
    4. the camera's daily flood image

    Explanation

    A sealed long-lived source such as cobalt-57 or barium-133 counted in a reproducible position shows whether the counting system's response has drifted from its established reference value. Patient counts and camera images cannot separate instrument drift from biological or equipment variation.

  196. Question 196Patient Care and Quality Control

    A patient scheduled for a solid-meal gastric emptying study should be instructed to:

    1. drink only clear liquids for 24 hours
    2. take a prokinetic drug one hour before
    3. eat a light breakfast that morning
    4. fast for at least 6 hours before the test Correct answer.

    Explanation

    Patients fast, typically at least six hours and often overnight, so that the radiolabeled meal is the first food to enter the stomach; medications that alter motility are withheld per protocol. Residual food would add unlabeled volume and slow emptying, invalidating the study.

  197. Question 197Patient Care and Quality Control

    When preparing technetium-99m macroaggregated albumin for a patient with severe pulmonary hypertension, the technologist should:

    1. reduce the number of particles administered Correct answer.
    2. vortex the vial to break up large aggregates
    3. filter out particles larger than 10 micrometers
    4. increase the particle number for better statistics

    Explanation

    In pulmonary hypertension the capillary bed is reduced, so a standard particle load can cause significant transient obstruction; the particle number is lowered, often to roughly 100,000 to 200,000, while activity remains adequate for imaging. Particle count rather than activity alone determines this risk.

  198. Question 198Patient Care and Quality Control

    A gamma camera produces acceptable intrinsic uniformity images but degraded extrinsic uniformity images. The most likely cause is:

    1. drifted photomultiplier tube gain
    2. an improperly centered energy window
    3. a damaged or soiled collimator Correct answer.
    4. incorrect peaking of the photopeak

    Explanation

    The collimator is the only component added when moving from an intrinsic to an extrinsic flood, so a defect seen only with the collimator in place points to septal damage, contamination, or poor seating. Detector-related faults such as photomultiplier drift or window errors degrade the intrinsic image as well.

  199. Question 199Patient Care and Quality Control

    A chi-square test is performed on a gamma camera's uniformity flood data to determine whether:

    1. camera sensitivity meets specification
    2. the collimator septa are properly aligned
    3. the photopeak is correctly centered
    4. count variation matches random statistical fluctuation Correct answer.

    Explanation

    The chi-square test compares observed pixel-to-pixel variation with the variation expected from Poisson counting statistics; a failed test indicates a nonrandom detector problem such as photomultiplier drift or an unstable tube. It is generally performed with an intrinsic flood at a defined weekly or daily interval.

  200. Question 200Patient Care and Quality Control

    An excessive aluminum ion concentration in a technetium-99m eluate is most likely to produce which problem?

    1. an artificially long measured half-life
    2. a falsely high molybdenum-99 breakthrough result
    3. colloid formation with unwanted liver uptake Correct answer.
    4. loss of collimator energy resolution

    Explanation

    Aluminum leaching from the alumina column can cause the radiopharmaceutical to aggregate into particles that are cleared by the reticuloendothelial system, appearing as liver or spleen activity on a bone scan. It also impairs labeling of kits such as sulfur colloid, which is why eluate aluminum content is monitored.

ARRT Nuclear Medicine flashcards

32 cards. Read the term and the definition here. The deck at the top of this page is optional.

Reversible myocardial perfusion defect
A stress image showing reduced tracer uptake that fills in on rest images; it indicates stress-induced ischemia rather than scarred myocardium.
V/Q mismatch
A perfusion defect with normal ventilation on lung scintigraphy; it raises suspicion for pulmonary embolism and is interpreted with clinical probability and chest imaging.
Three-phase bone scan
Dynamic flow, blood-pool, and delayed images after Tc-99m MDP; the sequence separates hyperemia from osteoblastic uptake and helps evaluate infection, fracture, or complex regional pain.
Hepatobiliary nonvisualization
Absence of gallbladder activity several hours after Tc-99m hepatobiliary tracer, especially with morphine augmentation, suggests acute cholecystitis when liver and bowel activity are present.
Meckel diverticulum scan
Tc-99m pertechnetate uptake in ectopic gastric mucosa in the right lower abdomen; it supports a Meckel diverticulum diagnosis, though other gastric or inflammatory lesions can mimic it.
Captopril renogram
Renal scintigraphy performed with an ACE inhibitor; a fall in relative function or prolongation of parenchymal transit suggests renovascular hypertension from unilateral renal artery stenosis.
Sentinel lymph node mapping
Injection of a radiolabeled colloid or tilmanocept near a tumor, followed by lymphoscintigraphy and gamma probe detection to identify the first draining nodes for biopsy.
Mo-99 breakthrough limit
The allowable Mo-99 activity in Tc-99m eluate is 0.15 kBq per MBq (0.15 µCi per mCi) of Tc-99m; exceeding it requires the eluate to be discarded.
Aluminum breakthrough
Alumina from a Tc-99m generator can appear in eluate; the limit is 10 µg/mL, and excess aluminum may cause particle aggregation and altered biodistribution.
Radiochemical purity
The fraction of total radioactivity present in the desired chemical form; it is measured by chromatography and must meet the package insert before a radiopharmaceutical is administered.
F-18 FDG half-life
Fluorine-18 has a 110-minute physical half-life; this limits shipping range and requires decay correction for dose calibration and PET scheduling.
MAA particle size
Technetium-99m macroaggregated albumin particles are typically 10 to 90 µm; they lodge in pulmonary capillaries after intravenous injection and must not be injected if clumped.
I-131 decay time
Iodine-131 has an 8.02-day half-life, so radioactive waste and patient precautions require decay through about 10 half-lives, or roughly 80 days, before release.
Photopeak energy window
A pulse-height analyzer accepts counts within a chosen energy range; for Tc-99m the 140-keV photopeak is commonly windowed at about ±10%, or 126 to 154 keV.
Center of rotation
The axis about which a gamma camera rotates during SPECT; misalignment produces ring or arc artifacts, so it is measured and corrected on a regular QC schedule.
Parallel-hole collimator
A collimator with parallel channels that preserves image size, increases resolution as hole length increases, and reduces sensitivity as septal thickness and hole length increase.
PET coincidence detection
Two 511-keV annihilation photons detected within a short timing window define an event; true coincidences localize the source, while scatter and random coincidences add background.
CT Hounsfield unit
A scaled CT attenuation value with water at 0 HU and air near -1000 HU; it allows tissue characterization and is used for attenuation correction in PET/CT.
Dead time
The interval after a detector event when the system cannot register another pulse; high activity causes count loss and can distort quantitation, especially in PET and first-pass studies.
Matrix and pixel size
Digital image dimensions define pixel size as field of view divided by matrix width; a larger matrix gives smaller pixels and finer display, but counts per pixel decrease.
Inverse square law
Radiation intensity from a point source varies inversely with the square of distance; doubling distance reduces exposure rate to one quarter of its original value.
Occupational dose limit
The annual effective dose limit for radiation workers is 50 mSv (5 rem), with a lens limit of 150 mSv and a skin or extremity limit of 500 mSv.
Fetal dose limit
After a worker declares pregnancy, the embryo-fetus dose limit is 0.5 mSv per month and 5 mSv over the entire gestation, with ALARA review of duties.
HVL lead for Tc-99m
The half-value layer of lead for Tc-99m gamma rays is about 0.3 mm; typical 0.5-mm lead aprons therefore attenuate a substantial but not complete fraction.
Radioactive waste decay
Short-lived waste is held for about 10 half-lives before release; Tc-99m requires roughly 60 hours, while I-131 requires about 80 days.
Contamination survey meter
A thin-window Geiger-Mueller or scintillation detector is used to find removable contamination; wipes are counted for gamma emitters and documented against release criteria.
Two-identifier patient check
Before radiopharmaceutical administration, staff verify at least two patient identifiers, such as name and date of birth, and match the dose label to the order.
Dose calibrator constancy
A daily check with a long-lived source verifies that the dose calibrator response is stable; accuracy, linearity, and geometry tests are performed on their own schedules.
Gamma camera uniformity QC
A daily flood image tests detector uniformity; nonuniformity appears as hot or cold spots and can produce ring artifacts, so corrections are applied before clinical imaging.
Breastfeeding after radiopharmaceutical
Lactating patients may need to interrupt breastfeeding and pump-and-discard for a period determined by the radiopharmaceutical, activity, and lactation guidance.
Extravasation response
If injection infiltrates, stop administration, estimate retained activity, apply local measures per protocol, document the event, and notify the authorized user and patient.
Renal function before contrast
Assess eGFR or creatinine when iodinated contrast or nephrotoxic drugs are planned; hydration and protocol adjustment reduce the risk of contrast-associated kidney injury.

ARRT Nuclear Medicine study guide

Diagnostic Procedures and Clinical Applications

Core concepts

Diagnostic nuclear medicine questions usually test a chain: indication → radiopharmaceutical → mechanism of localization → timing → expected normal distribution → common pitfalls. For bone scintigraphy with Tc-99m MDP, images are typically delayed 2–4 hours, with hydration and voiding before acquisition; a three-phase study adds flow and blood-pool phases. Myocardial perfusion uses rest/stress perfusion patterns; renal studies use tracers such as MAG3 or DTPA and require attention to hydration and bladder activity; hepatobiliary imaging uses IDA agents and timing after injection; thyroid imaging may use pertechnetate or radioiodine; V/Q and labeled-RBC studies have specific acquisition and contraindication issues. FDG PET requires fasting and glucose control per protocol.

Traps

A common trap is answering from the image pattern alone without matching the tracer’s biodistribution and the study timing. Urinary contamination, injection-site infiltration, and attenuation can mimic disease. Do not confuse blood-pool activity with delayed bone uptake. Know which studies are functional versus anatomic and when SPECT/CT adds localization.

Worked rule

If a delayed bone scan shows focal rib uptake, first confirm history of trauma, injection quality, and contamination; then correlate with prior imaging. A solitary focus is not automatically metastatic. Rule of thumb: interpret every finding against tracer, timing, and expected normal biodistribution.

Radiopharmacy and Radiopharmaceuticals

Core concepts

Radiopharmacy questions focus on producing a safe, pure, correctly assayed dose. The Mo-99/Tc-99m generator is eluted with saline to yield pertechnetate; know that Mo-99 breakthrough and aluminum breakthrough must be checked, and that eluate quality affects labeling. A cold kit contains nonradioactive ingredients; after adding pertechnetate, radiochemical purity is verified because unbound pertechnetate or hydrolyzed reduced technetium changes biodistribution. Distinguish radionuclidic purity, radiochemical purity, chemical purity, and specific activity. Dose calibrators measure activity; decay correction uses A = A0e^(−0.693t/T½). Always account for calibration time, assay time, and administration time.

Traps

Common errors include using the wrong half-life, forgetting that Tc-99m decays to half its activity every 6 hours, and confusing generator eluate with a final labeled product. Do not assume a kit is usable just because it is within its shelf life; follow labeling, storage, and purity limits. FDG and other PET agents require attention to expiry, assay, and patient preparation.

Worked example

A Tc-99m dose is 800 MBq at 08:00. At 20:00, 12 hours later, two half-lives have passed, so activity is 800 ÷ 2² = 200 MBq. If the prescribed dose is 200 MBq, the 08:00 assay is appropriate for a 20:00 administration only if the entire vial were used; in practice, draw and assay the patient dose at the correct time. Rule of thumb: for Tc-99m, each 6 hours halves the activity.

Instrumentation and Image Production, Including PET and CT

Core concepts

A gamma camera uses a collimator, a NaI(Tl) crystal, and photomultiplier tubes to convert scintillation light into position and energy signals. The energy window is set around the photopeak-commonly about 140 keV for Tc-99m-and must balance scatter rejection against count sensitivity. Collimator choice trades spatial resolution for sensitivity. Matrix size, field of view, and zoom determine pixel size, while count density affects noise. SPECT reconstructs projections into tomographic slices; PET detects annihilation photons at 511 keV in coincidence and commonly uses CT for attenuation correction and anatomic localization. Time-of-flight PET improves localization of annihilation events.

Traps

Do not equate smaller pixels with better intrinsic resolution; smaller pixels improve sampling but increase noise if counts are fixed. A wide energy window admits scatter, while a narrow window loses counts. In PET/CT, misregistration between PET and CT can create false attenuation-correction artifacts. Know that CT provides attenuation maps and anatomy, not PET tracer uptake. SUV is affected by body weight, injected dose, uptake time, and reconstruction, so compare cautiously.

Worked example

A camera has a 400 mm field of view and a 128 × 128 matrix. Pixel size is 400 mm ÷ 128 = 3.125 mm. A 256 × 256 matrix gives 1.5625 mm pixels, but the image may look noisier unless counts are sufficient. Rule of thumb: optimize pixel size, collimator, and count density together; never judge resolution from matrix size alone.

Radiation Safety and Protection

Core concepts

Radiation protection rests on ALARA: reduce time, increase distance, and use appropriate shielding. Exposure follows the inverse-square law, so doubling distance from a point source reduces exposure rate to one-quarter. Occupational dose limits, public limits, fetal limits, and dose-rate limits are distinct; know which limit applies to a worker, a member of the public, a declared pregnant worker, and an embryo/fetus. Contamination control differs from external exposure: use gloves, absorbent materials, surveys, and proper waste decay. PET radionuclides emit 511 keV photons, so shielding and distance planning matter. Packages and areas require radiation surveys and wipe tests under applicable regulations.

Traps

Questions often mix units or confuse dose limits with dose-rate limits. Do not apply the public limit to an occupationally exposed worker, and do not assume lead is equally effective at all energies. Remember that dose badges measure occupational exposure but do not replace surveys. Pregnant patients and workers require careful counseling and protocol-specific instructions; the decision to perform a study is made with the ordering practitioner.

Worked example

A source produces 4 mR/h at 1 m. At 2 m, exposure is 4 × (1/2)² = 1 mR/h. At 0.5 m, it is 4 × (1/0.5)² = 16 mR/h. Rule of thumb: move away rather than rely only on shielding; small distance changes have large effects.

Patient Care and Quality Control

Core concepts

Patient care begins with two identifiers, verification of the order and procedure, and pregnancy/breastfeeding screening when applicable. Explain the procedure, obtain consent per policy, assess allergies, renal function, and ability to cooperate, and use safe venipuncture technique. Recognize infiltration/extravasation, adverse reactions, and contamination; instruct patients to void when appropriate and drink fluids if protocol allows. Quality control is instrument-specific: dose calibrators require constancy, accuracy, linearity, and geometry checks; gamma cameras require daily uniformity/flood and energy checks plus resolution and sensitivity testing; survey meters and well counters require routine checks; PET systems have daily and periodic QC. Record results and investigate failures before patient use.

Traps

Questions often swap QC frequency or instrument. Daily constancy is not the same as annual accuracy, and a camera flood is not a dose-calibrator test. Do not use an expired kit or an uncalibrated instrument. Extravasation changes the administered activity and image quality; document and follow policy. A pregnant or breastfeeding patient needs protocol-specific guidance, not automatic cancellation.

Worked example

Before the first patient, perform the dose-calibrator constancy check with a long-lived source. If the reading differs from the expected value by more than the facility’s action limit-commonly around 10%-do not use the calibrator until the problem is resolved. Rule of thumb: QC is performed before patient use, documented, and repeated at the required interval.

ARRT Nuclear Medicine cheat sheet

Quick reference

Diagnostic Procedures / Clinical Applications

  • Tc-99m MDP bone scintigraphy uses flow, blood-pool, and delayed phases; focal increased uptake reflects osteoblastic activity, while photopenic foci can indicate aggressive lysis, infarction, or prosthesis.

  • Myocardial perfusion uses stress and rest Tc-99m sestamibi or tetrofosmin; a defect that improves at rest is reversible ischemia, whereas a fixed defect suggests scar or attenuation artifact.

  • V/Q lung scan uses Tc-99m MAA perfusion and aerosol or technegas ventilation; a perfusion defect with normal ventilation (mismatch) raises PE probability, especially with high clinical pretest probability.

  • Hepatobiliary scan uses Tc-99m mebrofenin or disofenin; gallbladder nonvisualization at 4 hours with intestinal activity suggests acute cholecystitis, and morphine augmentation can shorten the study.

  • Renal scintigraphy uses Tc-99m DTPA for GFR, Tc-99m MAG3 for tubular secretion and ERPF, and Tc-99m DMSA for cortical imaging; captopril renography assesses renovascular hypertension.

  • Thyroid imaging uses Tc-99m pertechnetate or I-123; a cold nodule requires correlation, and I-131 whole-body scanning follows thyroidectomy for differentiated thyroid cancer.

  • GI bleeding imaging with Tc-99m RBC can detect bleeding at approximately 0.1 mL/min; Meckel diverticulum imaging uses Tc-99m pertechnetate uptake by ectopic gastric mucosa.

  • Sentinel node lymphoscintigraphy uses Tc-99m sulfur colloid or tilmanocept injected near the tumor; the first draining node is identified with a gamma probe for biopsy.

  • Brain death imaging uses Tc-99m DTPA or HMPAO to demonstrate absent cerebral perfusion; the study must follow institutional criteria and may be confounded by scalp or venous activity.

Quick reference

Radiopharmacy and Radiopharmaceuticals

  • Mo-99/Tc-99m generator: Mo-99 (66 h) decays to Tc-99m (6.01 h); eluate must be assayed for Mo-99 breakthrough, with a limit of 0.15 kBq per MBq (0.15 µCi/mCi) Tc-99m.

  • Aluminum breakthrough limit is 10 µg/mL of eluate; excess Al3+ can aggregate particulate radiopharmaceuticals and alter biodistribution.

  • Purity types include radionuclidic purity (unwanted radionuclides), radiochemical purity (desired chemical form), chemical purity (nonradioactive impurities), plus sterility and apyrogenicity.

  • Common Tc-99m agents: MDP for bone, MAA for lung perfusion, MAG3 for renal tubular function, DTPA for GFR, sulfur colloid for liver/spleen/marrow, sestamibi for myocardial and parathyroid imaging, and pertechnetate for thyroid, Meckel, and gastric imaging.

  • PET isotopes: F-18 110 min, Ga-68 68 min, C-11 20 min, N-13 10 min, O-15 2 min, and Rb-82 76 sec; short half-lives dictate on-site production and rapid imaging.

  • Half-lives used for decay correction: I-131 8.02 days, I-123 13.2 h, Tc-99m 6.01 h, In-111 2.8 days, and Tl-201 73 h.

  • Kit preparation follows the package insert, verifies expiration and labeling efficiency, inspects for particles or discoloration, and uses aseptic technique with appropriate shielding.

  • Particle size: MAA 10-90 µm lodges in pulmonary capillaries; sulfur colloid 0.1-1 µm is phagocytosed by reticuloendothelial cells; filtered colloid is used for sentinel node mapping.

  • Dose calibration measures activity in a dose calibrator before administration and records time, activity, and volume, with decay correction to the calibration time on the label.

Quick reference

Instrumentation and Image Production (including PET and CT)

  • NaI(Tl) detector: a gamma ray produces light, photomultiplier tubes convert it to an electrical pulse, and a pulse-height analyzer selects the photopeak; energy resolution at Tc-99m 140 keV is about 10%.

  • Tc-99m photopeak window is commonly 140 keV ±10% (126-154 keV); I-131 is 364 keV and F-18 is 511 keV; incorrect windows increase scatter or lose true counts.

  • Collimator choice: parallel-hole preserves size, pinhole magnifies small organs, converging magnifies, and diverging minifies; resolution improves with longer holes and smaller hole diameter but sensitivity falls.

  • Daily gamma camera QC includes a uniformity flood; extrinsic uniformity includes the collimator; center of rotation and resolution/sensitivity checks follow defined schedules.

  • SPECT uses a 360-degree orbit with 60-120 projections; filtered backprojection or iterative reconstruction is used, with attenuation, scatter, and resolution recovery corrections improving quantitation.

  • PET detects 511-keV annihilation photons in coincidence; time-of-flight improves localization, and CT attenuation correction plus scatter correction are required for quantitative SUV.

  • CT numbers: water is 0 HU, air is about -1000 HU, and bone is high positive; window width and level control display, while pitch and mAs affect dose and image noise.

  • Image matrix: pixel size equals field of view divided by matrix width; a larger matrix yields smaller pixels but fewer counts per pixel, increasing noise unless counts are adequate.

  • High count rate causes dead time and pulse pileup; paralyzable systems show decreasing observed count rate at very high activity, so activity must be reduced or split.

Quick reference

Radiation Safety and Protection

  • ALARA: reduce time, increase distance, and use shielding; exposure rate obeys the inverse square law I1/I2 = (d2/d1)^2 for a point source.

  • NCRP occupational limits: 50 mSv/year effective dose, 150 mSv/year lens, and 500 mSv/year skin and extremities; the public limit is 1 mSv/year.

  • A declared pregnant worker has an embryo-fetus limit of 0.5 mSv/month and 5 mSv over gestation; duties are reviewed to maintain ALARA.

  • Half-value layer: lead HVL for Tc-99m is about 0.3 mm; a 0.5-mm lead apron attenuates a large fraction but not all gamma rays, and 511-keV PET photons require more shielding.

  • Waste decay: hold short-lived radionuclides for about 10 half-lives; Tc-99m requires about 60 hours and I-131 about 80 days; survey and document before disposal.

  • Contamination monitoring: a thin-window GM detector detects beta, a NaI scintillation detector detects gamma, and wipe tests identify removable contamination counted in a well counter.

  • Spill response: contain, mark, shield, survey personnel and area, remove contamination without spreading it, and report according to institutional and regulatory requirements.

  • Dose quantities: absorbed dose is in Gy, equivalent dose is in Sv with radiation weighting, and effective dose is in Sv with tissue weighting; these allow risk and limit comparisons.

  • Package receipt: survey the transport package, check removable contamination, verify the label and dosimeter, and document findings before radiopharmaceutical use.

Quick reference

Patient Care and Quality Control

  • Patient identification uses at least two identifiers and matches the dose label, order, and patient before administration; documentation includes radiopharmaceutical, activity, route, and time.

  • Pregnancy and lactation screening is performed before radiopharmaceutical administration; the authorized user provides fetal dose estimates and breastfeeding interruption guidance.

  • Dose calibrator QC includes daily constancy, quarterly linearity, quarterly accuracy, and geometry checks; results are recorded and the calibrator is removed from service if outside tolerance.

  • Gamma camera QC includes daily uniformity flood and periodic resolution, sensitivity, and center-of-rotation checks; collimator and detector artifacts are corrected before imaging.

  • Radiopharmaceutical QC includes visual inspection for particles or discoloration, pH where required, radiochemical purity by chromatography, and sterility or pyrogen testing per kit instructions.

  • Adverse reactions include anaphylaxis, vasovagal response, and extravasation; the study is stopped, basic life support is provided, the authorized user is notified, and the event is documented.

  • Pediatric dosing adjusts activity by weight or body surface area per institutional protocol; the smallest volume consistent with accurate counting is used and repeat imaging is minimized.

  • Patient instructions include hydration and frequent voiding to reduce bladder dose, plus breast-feeding and contact precautions specific to the radiopharmaceutical.

Quick reference

Diagnostic Procedures / Clinical Applications

  • Tc-99m MDP bone scintigraphy uses flow, blood-pool, and delayed phases; focal increased uptake reflects osteoblastic activity, while photopenic foci can indicate aggressive lysis, infarction, or prosthesis.

  • Myocardial perfusion uses stress and rest Tc-99m sestamibi or tetrofosmin; a defect that improves at rest is reversible ischemia, whereas a fixed defect suggests scar or attenuation artifact.

  • V/Q lung scan uses Tc-99m MAA perfusion and aerosol or technegas ventilation; a perfusion defect with normal ventilation (mismatch) raises PE probability, especially with high clinical pretest probability.

  • Hepatobiliary scan uses Tc-99m mebrofenin or disofenin; gallbladder nonvisualization at 4 hours with intestinal activity suggests acute cholecystitis, and morphine augmentation can shorten the study.

  • Renal scintigraphy uses Tc-99m DTPA for GFR, Tc-99m MAG3 for tubular secretion and ERPF, and Tc-99m DMSA for cortical imaging; captopril renography assesses renovascular hypertension.

  • Thyroid imaging uses Tc-99m pertechnetate or I-123; a cold nodule requires correlation, and I-131 whole-body scanning follows thyroidectomy for differentiated thyroid cancer.

  • GI bleeding imaging with Tc-99m RBC can detect bleeding at approximately 0.1 mL/min; Meckel diverticulum imaging uses Tc-99m pertechnetate uptake by ectopic gastric mucosa.

  • Sentinel node lymphoscintigraphy uses Tc-99m sulfur colloid or tilmanocept injected near the tumor; the first draining node is identified with a gamma probe for biopsy.

  • Brain death imaging uses Tc-99m DTPA or HMPAO to demonstrate absent cerebral perfusion; the study must follow institutional criteria and may be confounded by scalp or venous activity.

Quick reference

Radiopharmacy and Radiopharmaceuticals

  • Mo-99/Tc-99m generator: Mo-99 (66 h) decays to Tc-99m (6.01 h); eluate must be assayed for Mo-99 breakthrough, with a limit of 0.15 kBq per MBq (0.15 µCi/mCi) Tc-99m.

  • Aluminum breakthrough limit is 10 µg/mL of eluate; excess Al3+ can aggregate particulate radiopharmaceuticals and alter biodistribution.

  • Purity types include radionuclidic purity (unwanted radionuclides), radiochemical purity (desired chemical form), chemical purity (nonradioactive impurities), plus sterility and apyrogenicity.

  • Common Tc-99m agents: MDP for bone, MAA for lung perfusion, MAG3 for renal tubular function, DTPA for GFR, sulfur colloid for liver/spleen/marrow, sestamibi for myocardial and parathyroid imaging, and pertechnetate for thyroid, Meckel, and gastric imaging.

  • PET isotopes: F-18 110 min, Ga-68 68 min, C-11 20 min, N-13 10 min, O-15 2 min, and Rb-82 76 sec; short half-lives dictate on-site production and rapid imaging.

  • Half-lives used for decay correction: I-131 8.02 days, I-123 13.2 h, Tc-99m 6.01 h, In-111 2.8 days, and Tl-201 73 h.

  • Kit preparation follows the package insert, verifies expiration and labeling efficiency, inspects for particles or discoloration, and uses aseptic technique with appropriate shielding.

  • Particle size: MAA 10-90 µm lodges in pulmonary capillaries; sulfur colloid 0.1-1 µm is phagocytosed by reticuloendothelial cells; filtered colloid is used for sentinel node mapping.

  • Dose calibration measures activity in a dose calibrator before administration and records time, activity, and volume, with decay correction to the calibration time on the label.

Quick reference

Instrumentation and Image Production (including PET and CT)

  • NaI(Tl) detector: a gamma ray produces light, photomultiplier tubes convert it to an electrical pulse, and a pulse-height analyzer selects the photopeak; energy resolution at Tc-99m 140 keV is about 10%.

  • Tc-99m photopeak window is commonly 140 keV ±10% (126-154 keV); I-131 is 364 keV and F-18 is 511 keV; incorrect windows increase scatter or lose true counts.

  • Collimator choice: parallel-hole preserves size, pinhole magnifies small organs, converging magnifies, and diverging minifies; resolution improves with longer holes and smaller hole diameter but sensitivity falls.

  • Daily gamma camera QC includes a uniformity flood; extrinsic uniformity includes the collimator; center of rotation and resolution/sensitivity checks follow defined schedules.

  • SPECT uses a 360-degree orbit with 60-120 projections; filtered backprojection or iterative reconstruction is used, with attenuation, scatter, and resolution recovery corrections improving quantitation.

  • PET detects 511-keV annihilation photons in coincidence; time-of-flight improves localization, and CT attenuation correction plus scatter correction are required for quantitative SUV.

  • CT numbers: water is 0 HU, air is about -1000 HU, and bone is high positive; window width and level control display, while pitch and mAs affect dose and image noise.

  • Image matrix: pixel size equals field of view divided by matrix width; a larger matrix yields smaller pixels but fewer counts per pixel, increasing noise unless counts are adequate.

  • High count rate causes dead time and pulse pileup; paralyzable systems show decreasing observed count rate at very high activity, so activity must be reduced or split.

Quick reference

Radiation Safety and Protection

  • ALARA: reduce time, increase distance, and use shielding; exposure rate obeys the inverse square law I1/I2 = (d2/d1)^2 for a point source.

  • NCRP occupational limits: 50 mSv/year effective dose, 150 mSv/year lens, and 500 mSv/year skin and extremities; the public limit is 1 mSv/year.

  • A declared pregnant worker has an embryo-fetus limit of 0.5 mSv/month and 5 mSv over gestation; duties are reviewed to maintain ALARA.

  • Half-value layer: lead HVL for Tc-99m is about 0.3 mm; a 0.5-mm lead apron attenuates a large fraction but not all gamma rays, and 511-keV PET photons require more shielding.

  • Waste decay: hold short-lived radionuclides for about 10 half-lives; Tc-99m requires about 60 hours and I-131 about 80 days; survey and document before disposal.

  • Contamination monitoring: a thin-window GM detector detects beta, a NaI scintillation detector detects gamma, and wipe tests identify removable contamination counted in a well counter.

  • Spill response: contain, mark, shield, survey personnel and area, remove contamination without spreading it, and report according to institutional and regulatory requirements.

  • Dose quantities: absorbed dose is in Gy, equivalent dose is in Sv with radiation weighting, and effective dose is in Sv with tissue weighting; these allow risk and limit comparisons.

  • Package receipt: survey the transport package, check removable contamination, verify the label and dosimeter, and document findings before radiopharmaceutical use.

Quick reference

Patient Care and Quality Control

  • Patient identification uses at least two identifiers and matches the dose label, order, and patient before administration; documentation includes radiopharmaceutical, activity, route, and time.

  • Pregnancy and lactation screening is performed before radiopharmaceutical administration; the authorized user provides fetal dose estimates and breastfeeding interruption guidance.

  • Dose calibrator QC includes daily constancy, quarterly linearity, quarterly accuracy, and geometry checks; results are recorded and the calibrator is removed from service if outside tolerance.

  • Gamma camera QC includes daily uniformity flood and periodic resolution, sensitivity, and center-of-rotation checks; collimator and detector artifacts are corrected before imaging.

  • Radiopharmaceutical QC includes visual inspection for particles or discoloration, pH where required, radiochemical purity by chromatography, and sterility or pyrogen testing per kit instructions.

  • Adverse reactions include anaphylaxis, vasovagal response, and extravasation; the study is stopped, basic life support is provided, the authorized user is notified, and the event is documented.

  • Pediatric dosing adjusts activity by weight or body surface area per institutional protocol; the smallest volume consistent with accurate counting is used and repeat imaging is minimized.

  • Patient instructions include hydration and frequent voiding to reduce bladder dose, plus breast-feeding and contact precautions specific to the radiopharmaceutical.

ARRT Nuclear Medicine key terms

Bone scintigraphy

A nuclear medicine study in which a technetium-99m labeled diphosphonate tracer is injected and images are acquired hours later to show areas of increased bone turnover, such as fractures, metastases, or infection.

Related: Gamma camera, Collimator
Myocardial perfusion imaging

A study using tracers such as technetium-99m sestamibi or tetrofosmin to show blood flow to the heart muscle at stress and at rest, helping identify ischemia or infarction.

Related: Gamma camera, Attenuation correction
Ventilation-perfusion (V/Q) scan

A paired lung study comparing how air moves through the lungs (ventilation, often with an inhaled aerosol or gas) with how blood flows through them (perfusion), used mainly to look for pulmonary embolism.

Related: Gamma camera, Collimator
Hepatobiliary scintigraphy

Imaging with a technetium-99m iminodiacetic acid agent that is taken up by the liver and excreted into the biliary tree, used to assess gallbladder function and bile duct obstruction.

Related: Gamma camera, Radiochemical purity
Gastric emptying study

A study in which a standardized radiolabeled meal is eaten and images of the stomach are taken over one to four hours to measure how quickly food leaves the stomach.

Related: Gamma camera, Energy window
Sentinel lymph node mapping

A technique in which a radiolabeled colloid is injected near a tumor and the first draining lymph node is located with a gamma probe and images, guiding biopsy for cancer staging.

Related: Collimator, Radiochemical purity
Sestamibi parathyroid imaging

A dual-phase or subtraction study using technetium-99m sestamibi, which washes out of thyroid tissue faster than abnormal parathyroid tissue, to localize a hyperfunctioning parathyroid adenoma.

Related: Cold kit, Photopeak
FDG PET/CT oncology imaging

Whole-body imaging with fluorine-18 fluorodeoxyglucose combined with computed tomography to show tissues with high glucose metabolism, commonly used to stage and restage cancer.

Related: Blood glucose screening, Attenuation correction, Time-of-flight PET
Radionuclide generator

A shielded device containing a long-lived parent radionuclide that decays into a shorter-lived daughter, which is washed out with saline for patient use; the classic example is molybdenum-99 yielding technetium-99m.

Related: Eluate, Molybdenum-99 breakthrough
Eluate

The liquid collected from a radionuclide generator after saline is passed through its column; it contains the daughter radionuclide, such as sodium pertechnetate Tc-99m, ready for kit labeling.

Related: Radionuclide generator, Aluminum ion breakthrough, Molybdenum-99 breakthrough
Radionuclidic purity

The fraction of total radioactivity in a preparation that comes from the intended radionuclide rather than from contaminating radionuclides; it is verified, for example, by measuring molybdenum-99 breakthrough.

Related: Molybdenum-99 breakthrough, Eluate
Radiochemical purity

The percentage of the total radioactivity in a radiopharmaceutical that is present in the desired chemical form, determined by methods such as paper or thin-layer chromatography.

Related: Cold kit, Specific activity
Molybdenum-99 breakthrough

The presence of parent molybdenum-99 in technetium-99m eluate; because Mo-99 has a long half-life it adds unwanted dose, so regulatory limits apply and the level is measured before use.

Related: Eluate, Radionuclidic purity
Cold kit

A vial of non-radioactive reagents, usually lyophilized, to which pertechnetate or another radionuclide is added so that the tracer forms in a single simple step.

Related: Radiochemical purity, Specific activity
Specific activity

The amount of radioactivity per unit mass of a radionuclide or radiopharmaceutical, often given in becquerels per microgram, showing how much carrier material accompanies the radioactivity.

Related: Cold kit, Radiochemical purity
Aluminum ion breakthrough

Leakage of aluminum from a generator column into the eluate, which can make particles clump and reduce labeling yield; it is detected with a simple colorimetric test.

Related: Eluate, Cold kit
Gamma camera

An imaging device that detects gamma rays from a patient with a large scintillation crystal, converts the light flashes to electrical signals with photomultiplier tubes, and builds a picture of tracer distribution.

Related: Photomultiplier tube, Collimator, Photopeak
Photomultiplier tube

A vacuum tube that converts faint light flashes from the detector crystal into measurable electrical pulses and amplifies them, letting the system determine the position and energy of each event.

Related: Gamma camera, Photopeak
Collimator

A lead or tungsten plate with holes or channels placed in front of the detector that absorbs obliquely traveling gamma rays, so only those from a limited direction reach the crystal and form an image.

Related: Gamma camera, Spatial resolution
Photopeak

The peak in a gamma-ray energy spectrum produced by full-energy absorption of gamma rays from a given radionuclide; its position identifies the radionuclide and sets the imaging window.

Related: Energy window, Gamma camera
Energy window

A selected range of pulse heights accepted by the pulse height analyzer, usually centered on a photopeak, so primary gamma rays are counted while most scattered events are rejected.

Related: Photopeak, Dead time
Spatial resolution

The ability of an imaging system to show two nearby sources as separate, often described by the full width at half maximum of a line spread function; smaller values mean sharper images.

Related: Collimator, Gamma camera
Uniformity

How evenly a gamma camera responds across its entire field of view when exposed to a uniform source; poor uniformity appears as blotches or rings and requires tuning or correction.

Related: Photomultiplier tube, Gamma camera
Dead time

The brief period after each detected event during which the imaging system cannot record another; at high count rates it causes lost counts and inaccurate quantitation.

Related: Energy window, Gamma camera
Center of rotation

The axis about which the detector rotates during SPECT; misalignment between this mechanical axis and the computer's reconstruction center causes ring or blurring artifacts and must be checked regularly.

Related: Gamma camera, Uniformity
Attenuation correction

A correction applied to emission data to compensate for gamma rays absorbed or scattered inside the patient, often using a CT-derived map in PET/CT and SPECT/CT.

Related: Time-of-flight PET, FDG PET/CT oncology imaging
Time-of-flight PET

A PET capability that measures the tiny difference in arrival times of the two annihilation photons, narrowing the probable location of the event along the line of response and improving image quality.

Related: Attenuation correction, Photomultiplier tube
ALARA

The principle of keeping radiation doses as low as reasonably achievable, taking economic and social factors into account; it guides shielding choices, technique, and daily work habits.

Related: Inverse square law, Half-value layer, Occupational dose limit
Inverse square law

The rule that radiation intensity from a point source falls off with the square of distance, so doubling the distance from the source reduces exposure to one quarter.

Related: ALARA, Half-value layer
Half-value layer

The thickness of a specified material that reduces the intensity of a radiation beam by half; it is used to compare shielding materials and to describe beam quality.

Related: Inverse square law, ALARA
Occupational dose limit

The maximum permitted radiation dose for a radiation worker, commonly 50 millisievert (5 rem) per year to the whole body under United States regulations, apart from limited exceptions.

Related: ALARA, Declared pregnant worker
Declared pregnant worker

A person who has voluntarily told her employer in writing that she is pregnant and given the expected delivery date, which lowers the dose limit applied to the fetus.

Related: Occupational dose limit, ALARA
Contamination survey

A check for radioactive material on surfaces, equipment, or people, usually done with a survey meter and wipe tests to confirm that an area is clean.

Related: Sealed source leak test, ALARA
Sealed source leak test

A periodic check in which a sealed radioactive source is wiped and the wipe is counted to detect any radioactive material that has escaped from the capsule.

Related: Contamination survey, ALARA
Extravasation

Leakage of an injected radiopharmaceutical out of the vein into surrounding tissue, which can cause pain, swelling, and altered biodistribution; it is documented and managed promptly.

Related: Two-patient identifier, ALARA
Blood glucose screening

A check of the patient's blood glucose before fluorine-18 FDG imaging, because high glucose competes with the tracer and can reduce uptake in the tissues of interest.

Related: FDG PET/CT oncology imaging, Two-patient identifier
Dose calibrator constancy test

A daily check that the dose calibrator gives the same reading for a long-lived reference source over time, confirming that measured activities stay accurate.

Related: Eluate, Molybdenum-99 breakthrough
Two-patient identifier

The practice of confirming a patient's identity with two independent pieces of information, such as full name and date of birth, before giving a radiopharmaceutical or starting a study.

Related: Extravasation
Breastfeeding interruption

Temporarily stopping breastfeeding after a radioactive dose for a period based on the radionuclide's half-life and its excretion in milk, in order to limit the infant's exposure.

Related: ALARA

ARRT Nuclear Medicine study plan

8 weeks · About 6 hours per week

Week 1

Diagnostic Procedures / Clinical Applications

  • Map 15 core studies (bone scan, V/Q, myocardial perfusion, thyroid, renal, hepatobiliary, GI bleed, Meckel's, sentinel node, parathyroid, brain, lung shunt, gastric emptying, RBC, lymphoscintigraphy) to their radiopharmaceutical, adult dose range, patient preparation, and normal biodistribution.

  • Differentiate the clinical indications, contraindications, and typical findings for each mapped procedure.

  • Describe positioning, acquisition parameters (static, dynamic, whole-body, SPECT), and common technical artifacts for planar versus tomographic studies.

  • Explain how each study's result changes patient management for at least one representative pathology per study.

Your checkpoint

One-page protocol card for each of 15 studies, plus a score of 80% or higher on a 40-question Domain 1 self-quiz.

Week 2

Diagnostic Procedures / Clinical Applications & Radiopharmacy and Radiopharmaceuticals

  • Recall the radiopharmaceutical-to-procedure table closed-book to at least 90% accuracy.

  • Explain the mechanism of localization for each agent (chemisorption, phagocytosis, active transport, capillary blockade, antigen-antibody, compartmental distribution).

  • Calculate pediatric dose adjustments by weight and Clark's formula, and verify adult dose ranges against package insert values.

  • Compare the biodistribution, excretion pathway, and critical organ for the 10 highest-yield agents.

Your checkpoint

Closed-book 30-question mixed Domain 1/2 quiz scored at 85% or higher, plus a completed localization-mechanism comparison table.

Week 3

Radiopharmacy and Radiopharmaceuticals

  • Describe the Mo-99/Tc-99m generator system, elution process, and calculate eluate activity, concentration, and generator efficiency at a given time.

  • Perform pre-calibration and post-calibration decay calculations for Tc-99m, F-18, I-131, Ga-67, In-111, and Tl-201.

  • Evaluate radiopharmaceutical quality by describing radiochemical purity testing (paper and TLC), radionuclidic purity, aluminum breakthrough, and pH limits with their acceptance criteria.

  • Differentiate adverse reactions, drug interactions, and required patient preparation (thyroid blocking, fasting, medication holds) for common agents.

  • Outline aseptic technique, unit-dose handling, and record-keeping requirements for radiopharmacy operations.

Your checkpoint

20 timed calculation problems with fully worked solutions at 85% or higher accuracy, plus a completed generator elution and efficiency worksheet.

Week 4

Instrumentation and Image Production (including PET and CT)

  • Trace the signal path from scintillation crystal through PMT and pulse-height analyzer, and explain how energy window settings and peaking affect image quality.

  • Compare parallel-hole, pinhole, converging, diverging, and slant-hole collimators, and select the appropriate collimator for a given radionuclide energy and study.

  • Describe SPECT acquisition and reconstruction (filtered back projection versus iterative), attenuation correction methods, and PET detector, coincidence, and time-of-flight fundamentals.

  • Explain CT acquisition parameters and how CT data are used for attenuation correction and anatomic localization in SPECT/CT and PET/CT.

  • Identify uniformity, center-of-rotation, ring, motion, and truncation artifacts along with their cause and correction.

Your checkpoint

Annotated block diagram of the gamma camera and PET/CT signal chain, plus a 30-question Domain 3 quiz scored at 80% or higher.

Week 5

Instrumentation and Image Production (including PET and CT) & Radiation Safety and Protection

  • Calculate radiation exposure using the inverse square law, half-value layer, and time-distance-shielding principles.

  • Apply NRC and agreement-state dose limits for occupational workers, the public, declared pregnant workers, and breastfeeding patients.

  • Explain personnel and area monitoring with TLD/OSL badges, survey meters, wipe tests, and their action levels.

  • Describe spill response, decontamination procedures, and decay-in-storage radioactive waste handling.

  • Verify posting, labeling, and shielding requirements for restricted and unrestricted areas.

Your checkpoint

15-problem radiation safety calculation set with worked solutions, plus a completed spill-response checklist paired with a dose-limit reference table.

Week 6

Radiation Safety and Protection & Patient Care and Quality Control

  • Perform and interpret dose calibrator constancy, linearity, geometry, and accuracy tests and state the tolerance and frequency for each.

  • State the frequency, tolerance limit, and corrective action for gamma camera uniformity and resolution, well counter, survey meter, and PET daily QC tests.

  • Describe patient preparation, education, and contraindications for I-131, Sr-89, Ra-223, Y-90 microsphere, and other common therapies.

  • Explain infection control, extravasation management, and the care of pediatric, pregnant, and breastfeeding patients.

  • Apply ALARA-based workflow decisions to case scenarios involving staff, family, and public exposure.

Your checkpoint

Master QC table (test, frequency, tolerance limit, corrective action) plus a 25-question Domain 5 quiz scored at 85% or higher.

Week 7

Patient Care and Quality Control & Diagnostic Procedures / Clinical Applications & Radiopharmacy and Radiopharmaceuticals & Instrumentation and Image Production (including PET and CT) & Radiation Safety and Protection

  • Build an error log from every missed item in prior quizzes and rewrite each rationale in your own words.

  • Rehearse timed math drills covering decay, generator efficiency, pediatric dosing, attenuation, and exposure calculations.

  • Practice mixed question sets that interleave image interpretation, instrumentation, and radiopharmacy items.

  • Re-test the specific concepts that were missed most often until each reaches 85% mastery.

Your checkpoint

Error log with at least 40 corrected entries and a re-test score of 85% or higher on the previously missed concepts.

Week 8

Diagnostic Procedures / Clinical Applications & Radiopharmacy and Radiopharmaceuticals & Instrumentation and Image Production (including PET and CT) & Radiation Safety and Protection & Patient Care and Quality Control

  • Complete two timed full-length mock exams under test-like conditions.

  • Classify every miss as a knowledge gap, a misread stem, or a calculation slip, and remediate each category.

  • Recite high-yield flashcards on radiopharmaceuticals, dose limits, and QC tolerances without notes.

  • Finalize test-day logistics including scheduling, identification, arrival time, and a fatigue-management plan.

Your checkpoint

Two completed full-length mock exams scored at 80% or higher with a one-page high-yield summary sheet for final review.

Milestones

Week 2: Score 85% or higher on the closed-book 30-question Domain 1/2 quiz and complete the localization-mechanism table from memory.

Week 4: Score 75% or higher on a 100-question mid-point mock covering Domains 1-3, with no domain below 65%.

Week 6: Score 80% or higher on a 50-question mock covering Domains 4-5, and complete the master QC table with all tolerances correct.

Week 7: Score 75% or higher overall and 70% or higher in each of the five domains on a full-length 150-question mock.

Week 8: Score 80% or higher on both timed full-length mock exams, with all five domains at 75% or higher.

ARRT Nuclear Medicine exam day

Your checklist

Primary photo ID

Bring an unexpired, government-issued photo ID that includes your signature. The name on the ID must match your ARRT registration name exactly; if it does not, contact ARRT before test day to correct it. Confirm the accepted ID types (and whether a second form of ID is required) with ARRT/Pearson VUE.

Appointment confirmation

Have your exam appointment confirmation available, electronic or printed. Confirm with the testing provider whether a printed copy is required or whether a digital copy is acceptable.

Testing center logistics

Know the exact address, entrance, parking or transit options, and expected travel time. A dry run or map review the day before reduces morning-of uncertainty.

Confirmed arrival time

Check the arrival time printed on your confirmation. Many centers ask candidates to arrive well before the appointment slot; verify the exact requirement with the provider rather than guessing.

Corrected legal name on registration

If you recently married, divorced, or changed your name, verify that your ARRT record and ID agree. Mismatches are a common cause of admission problems.

Knowledge of what is provided versus prohibited

Testing centers generally supply an erasable note board and marker and prohibit personal calculators, notes, phones, and watches. Confirm the specific permitted-items list with the provider before relying on it.

Layered clothing

Testing rooms can be warm or cold. Dress in comfortable layers that comply with the provider's dress expectations; avoid items with large pockets or hoods that may need to be removed.

Snack and water for before/after

Bring a light snack and water to consume outside the testing room. Personal items must typically be stored in a provided locker during the exam.

Medication and health needs

Take routine medications as prescribed. If you need to bring medically necessary items into the testing room, confirm the procedure with the provider in advance.

Pre-arranged testing accommodations

If you need accommodations, they must be requested and approved well before the exam date. Confirm your approval status and any supporting documentation requirements with ARRT.

Transportation and emergency contact

Have a plan for getting home and a phone number for someone who can help if your test runs long or plans change.

Rest plan

Protect your sleep in the days before the exam. Fatigue affects performance more than one extra hour of late-night review helps.

Plan the day

Final 72 hours

Stop introducing new content. Do short, targeted review of your weakest content areas only, and stop studying at a reasonable hour each night.

Final 72 hours

Re-read your appointment confirmation: date, time, address, arrival instructions, and the permitted/prohibited items list. Note anything unclear and contact the provider to confirm.

Final 72 hours

Check that your photo ID is unexpired and that the name matches your registration. Resolve any discrepancy now rather than on test day.

Final 24 hours

Do a logistics check: confirm the center's location and hours, plan your route and backup route, and set two alarms. If weather or an emergency affects the center, contact the provider for instructions.

Final 24 hours

Pack your ID, confirmation, snack, water, and layers in one bag. Charge your phone and confirm your ride or transit plan.

Final 24 hours

No heavy cramming. Light review of high-yield summaries only, then stop. Eat a normal meal, limit caffeine and alcohol, and go to bed at your usual time.

Morning of

Eat a normal breakfast, hydrate, take routine medications, and leave earlier than the map suggests. Arrive at or before the time your confirmation specifies.

At check-in

Follow the staff's instructions for identity verification, photo, signature, and any biometric step. Ask where to store personal items and clarify the break policy before you begin.

During the test

Read each item fully before answering. Use the provided note board for calculations. If the platform allows flagging and reviewing within a section, flag uncertain items and return to them; confirm the review behavior at your workstation.

During the test

Pace yourself against the number of items and the clock rather than against how you feel. If a break is available, note that the clock generally continues to run; confirm this with the proctor first.

During the test

If equipment freezes, the screen goes blank, or anything seems wrong, raise your hand and notify the proctor immediately. Do not attempt to fix or restart the system yourself.

After the test

You will typically see a preliminary result on screen at the end of the exam. Treat it as preliminary; the official score report and any next steps come from ARRT. Confirm the reporting timeline with ARRT.

Rules to check

  • Your name on the registration must match your photo ID exactly. Bring an unexpired, government-issued photo ID with signature; confirm the required number and accepted types with ARRT or the testing provider.

  • Arrive by the time specified on your confirmation. Candidates who arrive late may be denied admission or have their appointment forfeited; confirm the exact late-arrival policy with the provider.

  • Personal items such as phones, watches, notes, and study materials are not allowed in the testing room. Use the locker or storage the center provides, and keep your phone off and stowed.

  • You will be asked to accept a confidentiality and ethics agreement. Do not discuss, reproduce, or share exam content with anyone, in any form, before or after the exam.

  • Break rules vary by provider: unscheduled breaks are often permitted, but the exam clock generally keeps running. Confirm the break policy with the proctor at check-in before you start.

  • Exam results are based on a scaled score with a passing standard set by ARRT. The on-screen result is preliminary; the official score report and any retake or application steps come from ARRT.

  • Testing accommodations must be approved in advance. Requests made on test day generally cannot be granted; confirm the process and deadlines with ARRT.

  • Report any irregularity, equipment problem, or distraction to the proctor immediately. Unresolved issues should also be documented with ARRT afterward so your exam record reflects what happened.

ARRT Nuclear Medicine FAQ

How many ARRT Nuclear Medicine practice questions are available?

The practice set has 200 ARRT Nuclear Medicine questions. Each one includes the choices, the correct answer, and an explanation, and the set is free to read with no signup.

How many ARRT Nuclear Medicine flashcards are available?

The flashcard set has 32 ARRT Nuclear Medicine cards. Each card shows the term and its definition.

Which topics does the ARRT Nuclear Medicine study material cover?

The ARRT Nuclear Medicine study material has 5 sections, including Diagnostic Procedures and Clinical Applications, Radiopharmacy and Radiopharmaceuticals, and Instrumentation and Image Production, Including PET and CT.

What format facts does the catalog list for the ARRT Nuclear Medicine exam?

The catalog lists these item types: multiple choice for the ARRT Nuclear Medicine exam.