ARRT CT Practice Test

ARRT Computed Tomography (CT) Certification and Registration Examination

ARRT CT overview

  • 200 practice questions
  • 32 flashcards
  • 3 study guide topics
  • 38 key terms

What you'll study

  • Patient Care and Education34%
  • Imaging Procedures33%
  • Physics and Instrumentation33%

ARRT certification and registration in Computed Tomography (CT) is a postprimary credential. ARRT states its purpose is to recognize individuals qualified to perform the role of a computed tomographer. It is aimed at technologists who already hold ARRT credentials in an approved supporting discipline - in some cases that supporting credential is earned through another organization, such as a Nuclear Medicine Technology credential from the NMTCB - and candidates pursue it through ARRT's postprimary eligibility pathway. The work itself spans the whole body: some patients are being evaluated for disease or an acute condition, others arrive in an emergency so physicians can gauge the extent of injury, and the technologist balances image quality against radiation dose while informing and calming anxious patients. The exam draws on the topics listed in ARRT's CT Examination Content Specifications, while the CT Task Inventory describes the job responsibilities typically required of technologists working in CT; clinical experience and structured education requirements apply as well. To prepare, read all four discipline documents early, build an outline directly from the content specifications, then download the postprimary eligibility pathway application handbook before applying. This page is an independent study resource and is not affiliated with or endorsed by ARRT.

Common mistakes

Clearing a patient for IV iodinated contrast after asking only about allergies, without checking eGFR/creatinine or metformin and AKI history.

Candidates memorise 'iodinated contrast is safe' and the allergy question as the whole screening ritual, so the renal-function and medication portion of the checklist drops out under time pressure.

What to do instead

Before every contrast exam, run a fixed five-item verbal checklist in the same order every time: allergy type and reaction, renal function/eGFR value and date, metformin/other nephrotoxic meds, pregnancy/breastfeeding status, and prior contrast reaction. Rehearse the checklist aloud on practice scenarios until it is automatic.

Treating a vasovagal reaction (bradycardia, hypotension, diaphoresis, pallor) as an allergic reaction, or vice versa, and starting the wrong intervention.

Both present within minutes of injection and both involve a distressed patient, so candidates pattern-match on 'reaction after contrast' instead of checking pulse and blood pressure first.

What to do instead

Memorise the discriminating vitals: vasovagal = bradycardia plus hypotension; anaphylactoid = tachycardia plus hypotension with urticaria/bronchospasm. On any post-injection event, take a pulse and BP before deciding, and drill 5–10 contrasting vignettes until the vital-sign pattern drives the answer.

Detecting an extravasation but continuing the injection or pulling the cannula immediately without assessing volume, then failing to describe the correct post-care (elevation, cold/warm compress, documentation, physician notification).

Extravasation appears as a single 'stop the injection' fact in review material, so the sequence and follow-up care are under-learned relative to the recognition step.

What to do instead

Write out and rehearse the full ordered sequence: stop injection, leave cannula in place to aspirate if protocol allows, remove, elevate extremity, apply compress per departmental policy, notify radiologist, document volume/site/symptoms, and arrange follow-up. Recall it as a numbered list, not a single keyword.

Choosing the wrong acquisition delay for multiphase studies - e.g. using a fixed 70-second delay for all abdominal phases, or scanning a CTA too late to catch arterial enhancement.

Candidates learn that 'liver is portal venous' and 'CTA is arterial' as labels but never attach the timing, bolus-triggering method, or contrast volume/rate to each phase, so numbers get guessed.

What to do instead

Build a one-page timing table pairing each protocol with its delay or trigger threshold (arterial, portal venous, delayed/excretory, CT urography, CTA, PE). Practice by naming the phase first, then reciting the delay and trigger before checking the answer.

Setting the wrong scan extent or landmark - cutting off the lung apices on a PE study, missing the skull base on a sinus protocol, or scanning far beyond the region of interest and inflating dose.

Attention goes to mA/kV/contrast and the topogram is treated as a formality, so the reconstructed volume is never checked against the ordered anatomy.

What to do instead

Adopt a routine: after the topogram, mark the superior and inferior boundaries on the scout and verify them against a memorised landmark list for each protocol. For high-yield exams (PE, sinus, cervical spine, renal colic) memorise the required start and end anatomy and recite it before each practice scan.

Confusing patient preparation requirements - giving oral contrast where it is contraindicated or unnecessary, allowing food when fasting is required, or omitting bowel prep for CT colonography.

Prep details are taught as departmental habit rather than as exam-specific rules, so candidates assume 'CT prep' is uniform across protocols.

What to do instead

Make a protocol-by-protocol prep matrix (fasting, oral contrast, IV access, bowel prep/tagging, medication holds) and self-quiz by exam name only. Flag the exceptions explicitly - e.g. exams where positive oral contrast obscures the finding you are looking for.

Computing pitch incorrectly or assuming that raising pitch increases patient dose.

Pitch is defined as table feed per gantry rotation divided by total beam collimation, and candidates invert it, use the single-slice collimation instead of the total, or apply an intuitive 'more pitch = more dose' rule.

What to do instead

Write the formula on a card, then work 10 numerical problems where detector configuration varies (e.g. 64 × 0.625 mm). Pair each answer with the dose relationship: with mA held constant, higher pitch generally lowers dose and can increase noise/artefact.

Mixing up what automatic exposure control (mA modulation) changes versus what tube-voltage selection changes, and expecting AEC to alter kV.

Both are 'automatic technique' features and both affect dose, so their inputs and outputs blur together; candidates also forget that AEC modulates along the z-axis and angularly.

What to do instead

Memorise two clean statements: AEC adjusts mA (and thus tube current) rotation-by-rotation and along z based on the attenuation measured on the topogram; kV is chosen by the technologist based on patient size, contrast enhancement, and artefact considerations. Then practise predicting which parameter moves in a given scenario.

Attributing spatial resolution to the wrong factor - believing window width, contrast concentration, or kV controls spatial resolution, or thinking a thinner slice improves low-contrast detectability.

Spatial resolution, contrast resolution, and noise are taught as a cluster of 'image quality' terms, so candidates assign effects to the wrong variable under exam pressure.

What to do instead

Build a cause-effect table: slice thickness, matrix size, FOV/pixel size, focal spot, and reconstruction kernel drive spatial resolution; mAs, slice thickness, and iterative reconstruction drive noise and low-contrast detectability; window settings only change display. Drill by predicting the change from one variable at a time.

Confusing dose descriptors and their units - reporting CTDIvol in mGy·cm, treating DLP as the displayed scanner value, or skipping the conversion to effective dose.

CTDIvol, DLP, and effective dose appear together in dose discussions and the units look similar, so candidates attach the wrong unit or formula to the right concept.

What to do instead

Anchor three facts: CTDIvol is weighted/averaged dose for a single rotation in mGy; DLP = CTDIvol × scan length in mGy·cm; effective dose = DLP × a region-specific conversion coefficient in mSv. Practise by converting a given CTDIvol and scan length through to DLP and effective dose.

Exam requirements can change. Confirm current details with the exam provider.

ARRT CT practice

200 questions. Each one lists the choices, the correct answer, and an explanation. With JavaScript, this list opens one question at a time. The checker at the top of this page saves progress in this browser when it is available.

  1. Question 1Patient Care and Education

    Before beginning a CT examination, the technologist should confirm the patient's identity by using which method?

    1. The written requisition alone
    2. The patient's date of birth only
    3. The patient's room number
    4. Two independent identifiers Correct answer.

    Explanation

    Patient safety standards require verification with at least two independent identifiers, such as full name plus date of birth or medical record number. The identifiers must be checked against the patient's wristband and the request. Location or a single identifier alone is not acceptable.

  2. Question 2Patient Care and Education

    Informed consent for a CT procedure involving intravenous contrast is obtained by:

    1. A qualified provider Correct answer.
    2. The scheduling clerk
    3. The patient's spouse
    4. The transport aide

    Explanation

    Consent for a procedure with contrast is a medical act that must be obtained by a provider qualified to explain the risks, benefits, and alternatives. Clerical, transport, and family members cannot obtain consent. The technologist may witness or verify that consent was documented.

  3. Question 3Patient Care and Education

    A patient of childbearing age is scheduled for CT of the abdomen and pelvis. The technologist's first step is to:

    1. Reduce the mAs by half
    2. Proceed without asking about pregnancy
    3. Apply a lead apron over the pelvis
    4. Ask whether she may be pregnant Correct answer.

    Explanation

    Screening for pregnancy by direct questioning is required before examinations that irradiate the abdomen or pelvis. If the answer is uncertain, the radiologist is consulted before proceeding. Shielding does not replace pregnancy screening.

  4. Question 4Patient Care and Education

    The single most effective routine practice for preventing transmission of infection from one patient to the next is:

    1. Wearing a lead apron
    2. Wiping the gantry with alcohol
    3. Changing gloves once per shift
    4. Performing hand hygiene Correct answer.

    Explanation

    Hand hygiene before and after every patient contact is the cornerstone of infection control. Gloves do not replace hand washing, and equipment cleaning is complementary rather than primary. Hand hygiene applies to all patients regardless of known infection status.

  5. Question 5Patient Care and Education

    Which history finding is most important to establish before administering intravenous iodinated contrast?

    1. History of hypertension
    2. Prior reaction to contrast Correct answer.
    3. Recent dental surgery
    4. Family history of diabetes

    Explanation

    A previous reaction to iodinated contrast is the strongest predictor of a repeat reaction and determines whether premedication or an alternative study is appropriate. Hypertension, family history, and recent dental work do not alter acute contrast risk. The history is documented before the injection begins.

  6. Question 6Patient Care and Education

    When teaching a patient to hold their breath for a chest CT, the technologist should:

    1. Ask the patient to breathe rapidly first
    2. Tell the patient to exhale fully and hold
    3. Scan while the patient breathes quietly
    4. Explain and demonstrate the hold Correct answer.

    Explanation

    Breath-hold instructions should be explained and demonstrated, then practiced before the scan so the patient knows what to expect. Chest CT is typically acquired at end-inspiration, not after full exhalation. Motion during acquisition degrades diagnostic quality.

  7. Question 7Patient Care and Education

    A patient who is deaf and uses sign language needs instructions for a CT examination. The best way to ensure understanding is to:

    1. Speak more loudly
    2. Use a qualified interpreter Correct answer.
    3. Proceed without instructions
    4. Ask a nearby patient to help

    Explanation

    Effective communication for a deaf patient requires a qualified sign language interpreter, in person or by video, to convey safety instructions accurately. Speaking louder does not help a patient who cannot hear. Other patients must never be used as interpreters because of privacy and accuracy concerns.

  8. Question 8Patient Care and Education

    Which action best promotes comfort and cooperation during a CT examination?

    1. Leaving the patient alone
    2. Keeping the room brightly lit
    3. Explaining sensations beforehand Correct answer.
    4. Rushing the instructions

    Explanation

    Describing what the patient will feel, such as warmth or a metallic taste from contrast, reduces anxiety and unexpected movement. Dimming lights, staying in contact, and allowing time for questions further improve cooperation. Rushed instructions increase misunderstanding and repeat scanning.

  9. Question 9Patient Care and Education

    During an intravenous contrast injection, a patient reports burning at the cannula site and swelling appears around the vein. The technologist should:

    1. Continue at a slower rate
    2. Flush the line with saline
    3. Finish the scan then assess
    4. Stop the injection at once Correct answer.

    Explanation

    Pain with swelling during injection indicates extravasation, and the injection must be stopped immediately to limit the volume of contrast in the tissues. The technologist then assesses the site, elevates the limb, applies a cold compress, and documents and reports the event. Continuing the injection worsens tissue damage.

  10. Question 10Patient Care and Education

    Which laboratory result is most commonly reviewed before elective intravenous iodinated contrast administration?

    1. Serum potassium
    2. Serum creatinine Correct answer.
    3. Hemoglobin level
    4. Platelet count

    Explanation

    Serum creatinine is used to estimate glomerular filtration rate, which determines whether a patient is at increased risk for contrast-associated kidney injury. Potassium, hemoglobin, and platelets do not directly guide contrast decisions. Renal function is reviewed especially in patients with diabetes, hypertension, or known kidney disease.

  11. Question 11Patient Care and Education

    A patient who takes metformin is scheduled for an elective contrast-enhanced CT. Current guidance for a patient with reduced renal function generally supports:

    1. Withholding metformin after contrast Correct answer.
    2. Doubling the metformin dose
    3. No change in metformin dosing
    4. Stopping metformin one week before

    Explanation

    In at-risk patients, metformin is typically withheld at the time of contrast administration and resumed after renal function is rechecked, usually at 48 hours. This reduces the risk of lactic acidosis if kidney function declines. Metformin is not stopped a week in advance, and the dose is never increased.

  12. Question 12Patient Care and Education

    Which finding is the most concerning sign of a severe anaphylactoid reaction to iodinated contrast?

    1. Stridor with hypotension Correct answer.
    2. Mild nausea
    3. A metallic taste
    4. A transient warm flush

    Explanation

    Airway compromise with hypotension indicates a severe reaction requiring immediate epinephrine and emergency support. A metallic taste, flushing, and mild nausea are common, self-limited sensations after contrast injection. Treatment urgency escalates with respiratory and hemodynamic involvement.

  13. Question 13Patient Care and Education

    A patient becomes pale and diaphoretic with a falling heart rate immediately after intravenous cannulation. This presentation most suggests:

    1. Contrast extravasation
    2. Thyroid storm
    3. A vasovagal reaction Correct answer.
    4. An anaphylactoid reaction

    Explanation

    Pallor, diaphoresis, and bradycardia with hypotension after needle placement are characteristic of a vasovagal response. Anaphylaxis typically produces tachycardia, urticaria, and bronchospasm. Management includes lying the patient flat with the legs elevated and monitoring vital signs.

  14. Question 14Patient Care and Education

    For a contrast-enhanced CT performed with a power injector, the intravenous access should be:

    1. A 22-gauge foot cannula
    2. A 24-gauge hand cannula
    3. A 20-gauge antecubital cannula Correct answer.
    4. A butterfly in the wrist

    Explanation

    Power injection requires a short, large-bore cannula in a robust proximal vein, most often a 20-gauge or larger device in the antecubital fossa. Small-gauge or distal access increases the risk of extravasation and cannot tolerate high flow rates. Institutional policy specifies the minimum gauge and maximum pressure.

  15. Question 15Patient Care and Education

    Which approach best reduces anxiety in a young child undergoing a CT examination?

    1. Promise the child it cannot hurt
    2. Show the scanner and speak simply Correct answer.
    3. Give all instructions quickly
    4. Ask the parents to wait outside

    Explanation

    A brief tour of the equipment with short, concrete explanations gives the child a sense of control and reduces fear. A parent usually stays nearby for reassurance when permitted. Promises about pain and hurried instructions undermine trust and cooperation.

  16. Question 16Patient Care and Education

    A patient under contact precautions for a resistant organism requires a CT scan. The technologist should:

    1. Refuse to scan the patient
    2. Wear gown and gloves, then clean the scanner Correct answer.
    3. Remove the gown in the hallway
    4. Scan with no precautions

    Explanation

    Contact precautions require a gown and gloves for room entry, removal of contaminated PPE before leaving, and disinfection of the scanner and surfaces the patient contacted. The study is performed because the examination is medically indicated. Refusal or omission of precautions is unacceptable.

  17. Question 17Patient Care and Education

    To reduce the risk of contrast-associated kidney injury in a high-risk patient, the technologist should ensure:

    1. A low-potassium diet
    2. Adequate hydration Correct answer.
    3. Twelve hours of fasting
    4. Rapid bolus injection

    Explanation

    Intravascular volume depletion is a modifiable risk factor, and hydration before and after contrast is the main supportive measure. Limiting contrast volume and reviewing nephrotoxic medications also help. Potassium restriction and prolonged fasting do not protect the kidneys.

  18. Question 18Patient Care and Education

    Which modification is most appropriate when positioning an older adult with fragile skin and limited mobility?

    1. Have the patient climb on alone
    2. Tape the arms tightly to the table
    3. Pad bony areas and move slowly Correct answer.
    4. Move quickly with thin padding

    Explanation

    Fragile skin and stiff joints make older patients prone to pressure injury and skin tears, so generous padding and slow, assisted transfers are used. The patient should never be hurried or left to transfer without help. Tape and tight straps can damage thin skin and should be avoided.

  19. Question 19Patient Care and Education

    A patient develops a few hives on the chest shortly after intravenous contrast administration but has normal breathing and blood pressure. The appropriate initial management is:

    1. Immediate discharge home
    2. Intramuscular epinephrine
    3. Cardiopulmonary resuscitation
    4. Observation with an antihistamine Correct answer.

    Explanation

    Isolated mild urticaria is a mild reaction managed by observation and, if needed, an antihistamine, with monitoring for progression. Epinephrine and resuscitation are reserved for moderate to severe reactions with airway, respiratory, or hemodynamic involvement. The patient is not released until symptoms resolve and the radiologist approves.

  20. Question 20Patient Care and Education

    A patient scheduled for CT weighs approximately 200 kg. Which consideration is most important for safe scanning?

    1. Use smaller collimation
    2. Confirm the table weight limit Correct answer.
    3. Reduce contrast to 20 mL
    4. Increase the pitch

    Explanation

    Each CT table and its drive mechanism has a maximum patient weight, commonly in the range of 200 to 230 kg depending on the model, and exceeding it can damage the equipment or injure the patient. Scanning parameters and contrast dose are adjusted after weight capacity is verified. Underdosing contrast would reduce diagnostic quality.

  21. Question 21Patient Care and Education

    For an elective contrast-enhanced CT in a patient with a prior moderate reaction to iodinated contrast, standard premedication consists of:

    1. Antibiotic plus steroid
    2. Steroid plus antihistamine Correct answer.
    3. Antihistamine after the scan
    4. Saline plus mannitol

    Explanation

    A corticosteroid given over several hours before the study, often combined with an antihistamine such as diphenhydramine, is the standard prophylaxis regimen. Premedication reduces but does not eliminate the risk of breakthrough reactions. Antibiotics, mannitol, and post-scan antihistamines have no prophylactic role.

  22. Question 22Patient Care and Education

    Which item is essential on the emergency cart for managing a severe contrast reaction?

    1. Oral rehydration solution
    2. Epinephrine for injection Correct answer.
    3. A handheld spirometer
    4. Topical hydrocortisone

    Explanation

    Intramuscular or intravenous epinephrine is the first-line drug for anaphylaxis and must be immediately available in the CT suite. Oxygen, suction, airway equipment, and a defibrillator are also stocked. Oral and topical preparations are of no value in an acute severe reaction.

  23. Question 23Patient Care and Education

    A breastfeeding mother asks whether she must stop nursing after receiving intravenous iodinated contrast. The correct advice is to:

    1. Pump and discard for 48 hours
    2. Stop nursing for two weeks
    3. Switch permanently to formula
    4. Continue breastfeeding normally Correct answer.

    Explanation

    The amount of iodinated contrast that reaches breast milk is very small and is poorly absorbed by the infant's gastrointestinal tract, so experts do not recommend interrupting breastfeeding. Temporary pumping and discarding is unnecessary. The mother may nurse without alteration of her routine.

  24. Question 24Patient Care and Education

    A pregnant patient asks about fetal risk from a medically necessary CT scan. The most appropriate response is to:

    1. Consult the radiologist about risk and benefit Correct answer.
    2. State that CT must never be done in pregnancy
    3. State that there is no fetal risk at any dose
    4. Offer pregnancy termination immediately

    Explanation

    Fetal risk depends on dose, gestational age, and the portion of the body irradiated, and the decision is made case by case by the radiologist with the referring clinician. At diagnostic doses, the absolute risk is very small, but the study should still be justified and optimized. Technologists do not counsel definitively on termination or absolute safety.

  25. Question 25Patient Care and Education

    Two hours after a contrast extravasation, a patient reports worsening pain, numbness, and a tense, swollen forearm. The technologist should:

    1. Arrange urgent medical evaluation Correct answer.
    2. Apply heat and reassure
    3. Schedule a repeat scan next week
    4. Massage the site firmly

    Explanation

    Progressive pain, numbness, and tense swelling suggest increasing compartment pressure, which requires prompt surgical or medical assessment. The limb should be elevated and monitored; heat, massage, and delay can worsen tissue injury. The event and follow-up are documented and reported.

  26. Question 26Patient Care and Education

    Before beginning a CT examination, the technologist confirms the patient's identity using which of the following?

    1. The name written on the patient's belongings bag
    2. The appointment slot on the scanner's printed daily schedule
    3. Full name and date of birth matched to the wristband Correct answer.
    4. The room number and time printed on the transport slip

    Explanation

    Accreditation standards require at least two patient identifiers, typically name plus date of birth or medical record number, verified verbally and against the identification band. Scheduling documents and personal belongings are not reliable identifiers.

  27. Question 27Patient Care and Education

    Who is responsible for obtaining informed consent for an elective contrast-enhanced CT?

    1. The referring physician who ordered the study
    2. The nurse who starts the intravenous line
    3. The radiologist supervising the examination Correct answer.
    4. The CT technologist assigned to the examination

    Explanation

    Informed consent is a physician responsibility; the radiologist responsible for the study discusses risks, benefits, and alternatives with the patient. Technologists and nurses may witness the signature but do not obtain consent.

  28. Question 28Patient Care and Education

    Before a CT examination of the abdomen and pelvis, which patient should be asked whether pregnancy is possible?

    1. Only patients younger than 18 years
    2. Every patient who is of childbearing age Correct answer.
    3. Only patients scheduled to receive intravenous contrast
    4. Only patients who mention a missed period

    Explanation

    Pregnancy status is screened for all patients of childbearing potential because the fetus is sensitive to ionizing radiation regardless of whether contrast is used. Relying on the patient to volunteer the information misses many at-risk individuals.

  29. Question 29Patient Care and Education

    A patient who speaks and reads little English arrives for a CT examination. Which approach best ensures the patient understands the instructions?

    1. Use a qualified medical interpreter Correct answer.
    2. Speak slowly and loudly while using hand gestures
    3. Ask an adult family member to translate the instructions
    4. Give the patient a printed English instruction sheet to read

    Explanation

    Accurate communication about radiation, contrast, and breath-holding requires a qualified medical interpreter, in person or by telephone. Untrained interpreters and written English materials risk misunderstanding and confidentiality problems.

  30. Question 30Patient Care and Education

    A patient is instructed to drink oral contrast before an abdominal CT. Which instruction is correct?

    1. Skip the contrast if nausea develops and proceed to the scan
    2. Drink the entire volume as quickly as possible on arrival
    3. Finish the full volume within the time specified before the scan Correct answer.
    4. Drink half the volume and discard the remainder

    Explanation

    Oral contrast must be ingested over a prescribed interval so it reaches and opacifies the bowel by the time of scanning. Drinking it all at once on arrival or taking only part of the volume results in inadequate opacification.

  31. Question 31Patient Care and Education

    A patient who uses a walker arrives for a CT scan. Which action best reduces the risk of a fall during transfer to the table?

    1. Let the patient climb onto the table alone to preserve independence
    2. Place the walker in the hallway so it does not block the scanner
    3. Raise the table to full height before the patient sits down
    4. Use a gait belt and keep the table at its lowest height during transfer Correct answer.

    Explanation

    Fall prevention relies on assisted transfer with a gait belt, a locked table at its lowest position, and the mobility aid kept within reach. Independent transfer and a raised table height both increase fall risk.

  32. Question 32Patient Care and Education

    A parent asks to remain in the scan room to keep a young child calm during a CT examination. The technologist should:

    1. Allow the parent to stay without providing any radiation protection
    2. Allow the parent to stay, provide a lead apron, and explain the small exposure Correct answer.
    3. Refuse the request, because only the patient may be in the scan room
    4. Ask the parent to leave and request sedation for the child instead

    Explanation

    A parent who assists cooperation may remain in the scan room; the technologist should explain the small scattered exposure and offer a lead apron. Sedation is not the first option when a cooperative adult can help the child stay still.

  33. Question 33Patient Care and Education

    Which accommodation is most helpful for a claustrophobic adult who wishes to attempt the scan without sedation?

    1. Place the patient prone on the table for the examination
    2. Ask the patient to keep both arms raised above the head
    3. Scan the patient feet first so the head remains near the bore opening Correct answer.
    4. Reduce the prescribed scan coverage to shorten the examination

    Explanation

    Feet-first positioning keeps the patient's head near the entrance of the gantry rather than deep inside the bore, which reduces the sense of confinement. The prescribed coverage is set by the radiologist and must not be reduced for anxiety.

  34. Question 34Patient Care and Education

    A patient receives moderate sedation for a CT examination. Which monitoring is required during the procedure?

    1. Visual observation from the control room window
    2. Blood pressure measurement every 30 minutes only
    3. Pulse oximetry recorded only at the start and end of the scan
    4. Continuous pulse oximetry plus periodic blood pressure and heart rate Correct answer.

    Explanation

    Sedated patients require continuous oxygenation monitoring with regularly documented blood pressure, heart rate, and respiratory status. Intermittent or remote observation can miss hypoxemia and hypoventilation.

  35. Question 35Patient Care and Education

    Which dietary instruction is given to a patient scheduled for a CT examination with moderate sedation?

    1. Only clear liquids are restricted, with no limit on solids
    2. No dietary restriction is needed when sedation is used
    3. A light breakfast is acceptable on the morning of the scan
    4. Solid food is withheld for the fasting interval set by facility policy Correct answer.

    Explanation

    Fasting before sedation reduces the risk of aspiration if the patient's airway reflexes are impaired. Policies typically restrict solids for a longer interval and clear liquids for a shorter one, and both categories are limited.

  36. Question 36Patient Care and Education

    A patient reports a severe allergy to latex. Which preparation is appropriate before the CT examination?

    1. Place the patient in a private waiting area and scan without other changes
    2. Stock the room with latex-free gloves, tubing, and blood pressure cuffs Correct answer.
    3. Proceed as usual and treat any reaction if it occurs
    4. Ask the patient to bring their own gloves for staff to wear

    Explanation

    Latex avoidance requires removing latex-containing items from the patient's environment, including gloves, tourniquets, tubing, and blood pressure cuffs. Staff must use facility-supplied latex-free equipment rather than waiting for a reaction.

  37. Question 37Patient Care and Education

    A patient with right-arm lymphedema after axillary lymph node surgery needs power-injected intravenous contrast. Access should be obtained:

    1. In either arm, because lymphedema does not affect injection
    2. In the unaffected left arm, in a vein suitable for power injection Correct answer.
    3. In a right forearm vein, with the tourniquet applied tightly
    4. In the right hand, using a small gauge catheter

    Explanation

    An arm with lymphedema or compromised lymphatic drainage has reduced venous return and a higher risk of extravasation and infection, so the unaffected limb is used. The site must also meet the gauge and pressure requirements of a power injector.

  38. Question 38Patient Care and Education

    A patient with an implanted cardiac pacemaker arrives for a CT examination of the chest. Which statement is correct?

    1. CT is generally safe; identify and document the device Correct answer.
    2. The scan may proceed without noting the device in the record
    3. CT is contraindicated for any patient with an implanted pacemaker
    4. The device must be reprogrammed before the scan is started

    Explanation

    CT does not use a strong magnetic field, so an implanted pacemaker is not a contraindication; the device should still be identified and documented for the patient record. Device reprogramming is an MRI consideration, not a routine CT step.

  39. Question 39Patient Care and Education

    During an intravenous contrast injection, a patient reports a warm flush and a metallic taste. The technologist should:

    1. Reassure the patient that these sensations are expected Correct answer.
    2. Stop the injection immediately and remove the cannula
    3. Call for emergency assistance and begin oxygen therapy
    4. Reduce the flow rate and restart the injection slowly

    Explanation

    A transient warm flush, metallic taste, and a sensation of urination are common and benign effects of iodinated contrast. The study can continue while the technologist provides brief reassurance.

  40. Question 40Patient Care and Education

    A patient who is blind is being positioned for a CT scan. Which approach best supports communication?

    1. Describe each step aloud and guide the patient's hand to the table Correct answer.
    2. Guide the hand to the table edge and leave the room
    3. Ask the escort to position the patient without any explanation
    4. Speak in a raised voice while moving the patient into position

    Explanation

    A patient who cannot see needs verbal description of each step and physical guidance to orient to the table and gantry. Speaking loudly does not improve understanding for someone with vision loss.

  41. Question 41Patient Care and Education

    Which instruction is appropriate when discharging a patient after a contrast-enhanced CT?

    1. Restrict fluid intake for 24 hours after the examination
    2. Return only if a rash appears within the first 24 hours
    3. Expect hives and treat them with an antihistamine at home
    4. Seek care promptly for hives, swelling, or difficulty breathing Correct answer.

    Explanation

    Delayed contrast reactions can occur hours after the injection, so patients are told to seek care for hives, swelling, wheezing, or breathing difficulty. Oral fluids are generally encouraged rather than restricted.

  42. Question 42Patient Care and Education

    A patient with a tracheostomy is scheduled for a CT examination of the chest. Which preparation is most important?

    1. Ask the patient to hold their breath for the entire examination
    2. Have suction and airway equipment available in the scan room Correct answer.
    3. Remove the tracheostomy tube before the patient enters the room
    4. Position the patient prone to protect the airway during scanning

    Explanation

    Patients with a tracheostomy are at risk for mucus plugging and airway obstruction, so suction and airway supplies must be immediately available. The tube is left in place and the patient is positioned supine for scanning.

  43. Question 43Patient Care and Education

    Before using an implanted venous access port for power-injected contrast, the technologist must confirm that:

    1. the port and needle are rated for the injection pressure Correct answer.
    2. the patient has no history of contrast allergy
    3. the port was placed more than one year ago
    4. the port is located on the side of the dominant hand

    Explanation

    Power injection through a port requires a device and needle approved for the flow rate and pressure used; non-power ports can rupture. The date of placement and the side of the body do not establish pressure tolerance.

  44. Question 44Patient Care and Education

    A patient scheduled for a CT examination of the head is wearing hairpins, a necklace, and a hearing aid. The technologist should:

    1. Tape the items firmly to the patient's head to prevent motion
    2. Leave all items in place, because they do not affect image quality
    3. Remove the metal and hearing aid and ask about implants Correct answer.
    4. Remove only the necklace, because it is closest to the skull

    Explanation

    Metal on or near the head produces streak artifact that can obscure brain tissue, so hairpins, jewelry, and hearing aids are removed before scanning. Asking about other implants is part of the same safety and artifact check.

  45. Question 45Patient Care and Education

    A patient reports a shellfish allergy and is scheduled for a contrast-enhanced CT. How should this history be interpreted?

    1. Shellfish allergy guarantees a severe reaction to iodinated contrast
    2. Shellfish allergy is an absolute contraindication to iodinated contrast
    3. Shellfish allergy does not predict a reaction to iodinated contrast Correct answer.
    4. Shellfish allergy requires premedication before every contrast study

    Explanation

    Shellfish allergy is a reaction to shellfish proteins, not to iodine, and it has not been shown to raise the risk of reaction to iodinated contrast. The history is still documented, but premedication is based on a prior reaction to contrast rather than on food allergy.

  46. Question 46Patient Care and Education

    A patient who receives maintenance hemodialysis needs an urgent contrast-enhanced CT. Which coordination is most appropriate?

    1. Give half the usual contrast dose and keep the usual dialysis time
    2. Cancel the examination because contrast is contraindicated in dialysis patients
    3. Delay dialysis for one week to allow the contrast to clear
    4. Arrange dialysis within the patient's planned schedule after the scan Correct answer.

    Explanation

    In patients with little or no renal function, contrast clearance depends on dialysis, so the study is coordinated with the dialysis team to fit the existing schedule. Emergent dialysis is generally not required for a single contrast dose.

  47. Question 47Patient Care and Education

    A patient with severe claustrophobia cannot remain still for the CT despite coaching and feet-first positioning. The most appropriate next step is to:

    1. repeat the coaching until the patient completes the scan
    2. physically restrain the patient for the duration of the scan
    3. perform the scan despite motion and accept the degraded images
    4. consult the radiologist about sedation or anesthesia assistance Correct answer.

    Explanation

    When non-pharmacologic measures fail, the radiologist should be consulted so sedation or anesthesia support can be arranged. Restraint and continued repetition are not acceptable substitutes for adequate anxiolysis.

  48. Question 48Patient Care and Education

    An adult with cognitive impairment arrives alone for an elective CT and cannot provide consent. No health care agent can be reached. The technologist should:

    1. Proceed, because an elective CT does not require consent
    2. Scan the patient because the referring physician ordered the study
    3. Ask a coworker to sign the consent form as a witness
    4. Postpone the elective study until a lawful surrogate can consent Correct answer.

    Explanation

    Elective contrast and radiation exposure require valid consent, which must come from the patient or a legally authorized surrogate. A coworker cannot consent, and a physician order is not a substitute for consent.

  49. Question 49Patient Care and Education

    Which precaution is most important when a neonate undergoes a CT examination?

    1. Restrict oral intake for 6 hours before the scan
    2. Keep the infant warm with blankets and minimize time in the cool room Correct answer.
    3. Increase the room temperature to 30 degrees Celsius (86 F)
    4. Position the infant in a prone position for the entire study

    Explanation

    Neonates lose body heat rapidly and are at risk of hypothermia in a cool scan room, so warming with blankets and an efficient examination are priorities. Fasting and prone positioning are not required for a non-sedated neonatal CT.

  50. Question 50Patient Care and Education

    A patient with well-controlled asthma is scheduled for a contrast-enhanced CT. Which action is appropriate?

    1. Premedicate with corticosteroids regardless of prior reactions
    2. Cancel the study, because asthma is a contraindication to contrast
    3. Document the asthma history and proceed if the patient is stable Correct answer.
    4. Withhold the patient's bronchodilator until after the scan

    Explanation

    Well-controlled asthma is not a contraindication to iodinated contrast; the history is documented and the patient is assessed for stability. Premedication is reserved for patients with a documented prior reaction to contrast, not for asthma alone.

  51. Question 51Patient Care and Education

    Before starting a CT examination, the technologist should confirm the patient's identity by:

    1. Comparing the patient's appearance with the previous scan
    2. Asking the patient to state the room number assigned
    3. Checking two identifiers, such as full name and date of birth Correct answer.
    4. Reviewing the requisition for the patient's medical record number

    Explanation

    Two identifiers, such as full name and date of birth, must match the requisition and patient wristband before any scanning. Room assignment and visual appearance are not reliable identifiers.

  52. Question 52Patient Care and Education

    For a CT examination of the chest that requires breath-holding, which instruction is best?

    1. Take a deep breath in, then hold it without breathing out Correct answer.
    2. Breathe normally and the scanner will correct for motion
    3. Hold your breath after exhaling completely
    4. Breathe rapidly during the scan so motion is consistent

    Explanation

    An inspiratory breath-hold expands the lungs and limits respiratory motion during image acquisition. Clear coaching before the scan helps the patient reproduce the same breath-hold.

  53. Question 53Patient Care and Education

    Which statement best describes informed consent for an intravenous contrast-enhanced CT?

    1. Consent is implied when the patient arrives for the appointment
    2. Consent is required only for patients with a prior contrast reaction
    3. The patient understands the purpose, risks, benefits, and alternatives Correct answer.
    4. The referring physician's written order replaces the need for patient consent

    Explanation

    Informed consent requires that the patient receive and understand information about the purpose, risks, benefits, and alternatives of the contrast-enhanced examination. A signed order alone does not replace this discussion.

  54. Question 54Patient Care and Education

    Which question is most important to ask a patient before administering iodinated contrast?

    1. Have you had a reaction to contrast or a severe allergy? Correct answer.
    2. Do you have any history of kidney stones?
    3. Have you eaten any food in the past 2 hours?
    4. Are you currently taking any multivitamins or herbal supplements?

    Explanation

    A history of prior contrast reaction or severe allergy identifies a patient at increased risk and guides premedication or alternative planning. It should be obtained before any contrast is given.

  55. Question 55Patient Care and Education

    A patient who speaks limited English is scheduled for a contrast-enhanced CT. Which action is best?

    1. Ask a bilingual family member to interpret sensitive information
    2. Delay the scan until the patient learns enough English
    3. Proceed using hand gestures and written English instructions
    4. Use a qualified medical interpreter for the discussion Correct answer.

    Explanation

    A qualified medical interpreter ensures accurate understanding of instructions, risks, and consent for a patient with limited English proficiency. Family members should not be relied on for sensitive medical interpretation.

  56. Question 56Patient Care and Education

    A 28-year-old woman of childbearing age is scheduled for CT of the abdomen and pelvis. Which action is appropriate before scanning?

    1. Perform a pregnancy test on every woman in this age group
    2. Shield the pelvis routinely and proceed without asking about pregnancy
    3. Cancel the examination because of possible pregnancy risk
    4. Ask about pregnancy and last menstrual period, then document Correct answer.

    Explanation

    For a patient of childbearing age, pregnancy status and last menstrual period should be asked about and documented before abdominal or pelvic CT. This allows the team to consider whether the examination is justified and whether dose optimization is needed.

  57. Question 57Patient Care and Education

    During power injection, contrast extravasates into the soft tissues of the patient's arm. What should the technologist do first?

    1. Stop the injection immediately Correct answer.
    2. Continue the injection and monitor the site
    3. Apply warm compresses before stopping the injection
    4. Massage the site to help the contrast disperse

    Explanation

    The injection must be stopped as soon as extravasation is recognized to limit the volume of contrast in the soft tissues. The site is then assessed and managed according to department policy.

  58. Question 58Patient Care and Education

    A patient with type 2 diabetes taking metformin has chronic kidney disease and needs an elective contrast-enhanced CT. Which action is most appropriate?

    1. Proceed without checking renal function because metformin is not a concern
    2. Withhold metformin for 48 hours before the scan and proceed
    3. Cancel the scan because metformin is an absolute contraindication
    4. Check renal function and coordinate metformin use with the clinician Correct answer.

    Explanation

    Metformin management depends on renal function; current guidance generally allows continuation when eGFR is adequate but recommends withholding and coordination when renal function is impaired. Checking renal function and involving the referring clinician is the safe approach.

  59. Question 59Patient Care and Education

    Shortly after intravenous contrast administration, a patient becomes pale, diaphoretic, and bradycardic. Which action is most appropriate?

    1. Sit the patient upright and give oral fluids immediately
    2. Administer intramuscular epinephrine without delay
    3. Place the patient supine, elevate the legs, and monitor Correct answer.
    4. Continue the scan and reassess after the images are complete

    Explanation

    Pale, diaphoretic, and bradycardic findings suggest a vasovagal reaction. Lying the patient supine with legs elevated improves venous return and cerebral perfusion while vital signs are monitored.

  60. Question 60Patient Care and Education

    A patient reports a prior moderate allergic reaction to iodinated contrast and needs an elective contrast-enhanced CT. What is the best action?

    1. Contact the referring clinician to discuss premedication before the study Correct answer.
    2. Cancel all future contrast studies for this patient
    3. Use a lower dose of contrast to prevent another reaction
    4. Administer the contrast without premedication because reactions are rare

    Explanation

    A prior moderate allergic reaction increases the risk of another reaction, so the referring clinician and radiologist should discuss premedication or an alternative study before elective contrast administration. The decision is individualized.

  61. Question 61Patient Care and Education

    Which laboratory value is most useful for estimating renal function before iodinated contrast administration?

    1. Serum amylase level from the admission laboratory results
    2. Hemoglobin concentration from the complete blood count
    3. Serum potassium level from the most recent chemistry panel
    4. Estimated glomerular filtration rate Correct answer.

    Explanation

    eGFR is calculated from serum creatinine and patient factors and is the standard laboratory estimate of renal function used before iodinated contrast. It guides risk assessment and metformin management.

  62. Question 62Patient Care and Education

    A young child cannot hold still for a CT scan despite coaching and parental presence. Which action is most appropriate?

    1. Proceed and accept motion artifact on the images
    2. Ask the parent to physically restrain the child for the entire scan
    3. Use age-appropriate immobilization and limit repeat scans Correct answer.
    4. Increase the scan speed by reducing image quality

    Explanation

    Age-appropriate immobilization, such as a papoose or gentle positioning aids, helps a young child remain still while limiting radiation from repeat scans. Physical restraint by a parent is not appropriate for the entire study.

  63. Question 63Patient Care and Education

    A patient with active pulmonary tuberculosis is scheduled for a CT scan. Which precaution is most important?

    1. Clean the scanner with standard disinfectant after the scan
    2. Place the patient in the general waiting area until called
    3. Wear gloves and a gown only when touching the patient
    4. Use airborne precautions, including an N95 respirator Correct answer.

    Explanation

    Active pulmonary tuberculosis requires airborne precautions, including an N95 respirator and appropriate room ventilation, to prevent transmission. Standard gloves and gown alone do not protect against airborne droplet nuclei.

  64. Question 64Patient Care and Education

    A patient with a colostomy bag is scheduled for CT of the abdomen and pelvis. What should the technologist do?

    1. Empty or remove the bag before positioning Correct answer.
    2. Scan through the bag without any preparation
    3. Ask the patient to remove the bag after the scan
    4. Fill the bag with water to improve contrast

    Explanation

    A colostomy bag can contain air or material that produces artifact and may interfere with positioning. Emptying or removing it when possible improves image quality and patient comfort.

  65. Question 65Patient Care and Education

    Before power injection of contrast through a peripheral IV, which check is most important?

    1. Verify that the IV was placed within the last hour
    2. Check that the IV tubing is longer than 12 inches
    3. Confirm that the IV is at least 24 gauge in the hand
    4. Confirm blood return and easy flushing of the IV Correct answer.

    Explanation

    Before power injection, the IV must be confirmed to be in a suitable vein with blood return and easy flushing. This reduces the risk of extravasation during high-flow contrast administration.

  66. Question 66Patient Care and Education

    A patient develops stridor, hypotension, and urticaria after contrast injection. Which medication is the first-line treatment?

    1. Intravenous furosemide infusion
    2. Inhaled albuterol
    3. Oral diphenhydramine
    4. Intramuscular epinephrine Correct answer.

    Explanation

    Stridor, hypotension, and urticaria indicate anaphylaxis, for which intramuscular epinephrine is the first-line treatment. Supportive care and emergency response follow immediately.

  67. Question 67Patient Care and Education

    A patient with multiple myeloma and normal renal function needs iodinated contrast. Which precaution is most appropriate?

    1. Give a prophylactic antihistamine before contrast
    2. Withhold all fluids for 6 hours after the scan
    3. Reduce the contrast dose by half regardless of indication
    4. Ensure adequate hydration before and after contrast Correct answer.

    Explanation

    Patients with multiple myeloma are at increased risk of renal injury from iodinated contrast, and adequate hydration is the main preventive measure. Renal function should be assessed and the study performed only when indicated.

  68. Question 68Patient Care and Education

    A pregnant patient needs a CT scan for suspected pulmonary embolism. Which statement is correct?

    1. A pregnancy test must be negative before any CT can be performed
    2. The scan should be delayed until after delivery in all cases
    3. Radiation exposure always outweighs the benefit of diagnosis
    4. Perform the scan if medically necessary with dose optimization Correct answer.

    Explanation

    When a pregnant patient has a medically necessary indication such as suspected pulmonary embolism, the examination should not be withheld solely because of pregnancy. The protocol should be optimized to deliver the needed diagnostic information with the lowest reasonable dose.

  69. Question 69Imaging Procedures

    In a routine adult head CT, the scan plane is most commonly set parallel to which landmark?

    1. Orbitomeatal line Correct answer.
    2. A line joining the vertex and the chin
    3. A line parallel to the inferior border of the mandible
    4. A line parallel to the hard palate

    Explanation

    Routine head CT is acquired in an axial plane parallel to the orbitomeatal line, extending from the skull base to the vertex. This plane keeps the slice angle reproducible between patients and limits direct exposure of the lens.

  70. Question 70Imaging Procedures

    Which display setting best demonstrates gray-white differentiation within the brain parenchyma?

    1. WW 2000 / WL 500
    2. WW 1500 / WL -600
    3. WW 400 / WL 40
    4. WW 80 / WL 40 Correct answer.

    Explanation

    Brain tissue differs from cerebrospinal fluid by only a few Hounsfield units, so a narrow window width of about 80 HU centered near 40 HU is needed to display that contrast. Wider windows compress the small differences and make the parenchyma look uniform.

  71. Question 71Imaging Procedures

    Which window setting is used to evaluate a small pulmonary nodule on a chest CT?

    1. WW 1500 / WL -600 Correct answer.
    2. WW 400 / WL 40
    3. WW 200 / WL 80
    4. WW 2000 / WL 500

    Explanation

    Lung parenchyma and small nodules are assessed on a wide window of roughly 1500 HU centered around -600 HU. This setting allows air-filled lung to be displayed without saturating the soft tissue structures.

  72. Question 72Imaging Procedures

    A patient is positioned for a routine CT examination of the abdomen and pelvis. Which setup is standard?

    1. Supine, feet first Correct answer.
    2. Prone, head first
    3. Supine, head first
    4. Decubitus, feet first

    Explanation

    Body CT studies of the abdomen and pelvis are acquired supine with the patient entering the gantry feet first, which shortens the table travel relative to the operator. Prone or decubitus positions are reserved for specific indications such as biopsy or colonography.

  73. Question 73Imaging Procedures

    Which instruction should be given to a patient immediately before a CT examination of the chest?

    1. Exhale completely and hold during the scan
    2. Suspend respiration after a full inspiration Correct answer.
    3. Breathe rapidly throughout the scan
    4. Hum continuously during the acquisition

    Explanation

    Chest CT is acquired in suspended full inspiration so that the lungs are maximally aerated and the diaphragm is held in a reproducible position. Motion during acquisition degrades both lung and mediastinal detail.

  74. Question 74Imaging Procedures

    Which protocol best describes a routine CT of the paranasal sinuses?

    1. No IV contrast with a lung window and thick slices
    2. IV contrast with a soft tissue window and 5-mm slices
    3. No IV contrast with a bone window and thin slices Correct answer.
    4. IV contrast with a delayed phase and 3-mm slices

    Explanation

    Sinus CT is a non-contrast, thin-section study displayed in a bone window because the clinical question is mucosal thickening and bony ostial anatomy. Intravenous contrast is added only when a complication or tumor is suspected.

  75. Question 75Imaging Procedures

    What is the primary purpose of the scout (localizer) image obtained at the start of a CT examination?

    1. To plan the scan range and angle Correct answer.
    2. To measure the patient's radiation dose
    3. To set the contrast injection rate
    4. To reconstruct coronal images

    Explanation

    The scout image defines the patient's anatomy in the gantry so the technologist can prescribe the start and end of the scan volume and any required gantry angle. It is also used to check centering before dose is delivered to the planned volume.

  76. Question 76Imaging Procedures

    Coronal and sagittal reformations of a CT study are generated from which source data?

    1. The dose report
    2. The axial image stack Correct answer.
    3. The scout projection only
    4. The contrast injection log

    Explanation

    Multiplanar reformations are mathematically derived from the acquired axial volume, provided the slices are thin enough and overlap adequately. Thin axial acquisition allows high-quality coronal and sagittal images.

  77. Question 77Imaging Procedures

    During CT pulmonary angiography with bolus tracking, the monitoring region of interest is normally placed in the:

    1. Superior vena cava
    2. Main pulmonary artery Correct answer.
    3. Descending aorta
    4. Ascending aorta

    Explanation

    Triggering on the main pulmonary artery acquires the scan while the pulmonary arterial tree is maximally opacified and before contrast significantly fills the aorta. A typical threshold is around 100 HU over baseline.

  78. Question 78Imaging Procedures

    A multiphase liver CT is ordered for a suspected hypervascular tumor. Which phase best demonstrates arterial enhancement of the lesion?

    1. Portal venous phase
    2. Unenhanced phase
    3. Delayed phase
    4. Late arterial phase Correct answer.

    Explanation

    Hypervascular lesions such as hepatocellular carcinoma enhance maximally in the late arterial phase, roughly 35 to 40 seconds after injection. The portal venous phase is required for venous anatomy and washout assessment but shows less arterial peak enhancement.

  79. Question 79Imaging Procedures

    A patient presents with acute flank pain and suspected ureteral stone. Which study is most appropriate?

    1. Contrast-enhanced CT of the abdomen
    2. Unenhanced CT of the abdomen and pelvis Correct answer.
    3. Delayed phase CT of the abdomen only
    4. CT urography in the excretory phase

    Explanation

    Unenhanced thin-section CT of the abdomen and pelvis detects nearly all urinary calculi and avoids contrast, which can obscure small stones. It is fast and delivers less radiation than a multiphase study.

  80. Question 80Imaging Procedures

    For a CT study of the stomach and duodenum, which agent is commonly administered orally to act as a negative (neutral) contrast material?

    1. Dilute barium sulfate
    2. Iohexol 300 mg I/mL
    3. Effervescent granules alone
    4. Water Correct answer.

    Explanation

    Water distends the stomach and bowel while remaining near 0 HU, creating neutral contrast that makes enhancing wall and vessels stand out. It is inexpensive and is the standard neutral oral agent for gastric protocols.

  81. Question 81Imaging Procedures

    Why is intravenous contrast often injected into an antecubital vein on the patient's right side?

    1. It eliminates the risk of contrast extravasation
    2. It reduces the total volume of contrast that must be injected
    3. It shortens the duration of the arterial acquisition phase
    4. It avoids streak artifact in the left brachiocephalic vein Correct answer.

    Explanation

    Dense contrast in the left brachiocephalic vein produces streak artifact that can obscure the aortic arch and great vessels. A right-sided injection avoids this pathway and yields cleaner arterial images.

  82. Question 82Imaging Procedures

    Which acquisition technique is most appropriate for a CT examination of the temporal bones?

    1. 10-mm slices, head filter
    2. 5-mm slices, large field of view
    3. Sub-millimeter slices, small field of view Correct answer.
    4. 3-mm slices, soft tissue algorithm

    Explanation

    Temporal bone imaging requires the highest spatial resolution available, achieved with sub-millimeter collimation, a small reconstruction field of view, and a high-frequency kernel. Thin sections also permit reformation in any plane.

  83. Question 83Imaging Procedures

    For a CT angiography runoff study of the lower extremities, scan timing is best achieved by:

    1. A fixed 25-second delay after injection
    2. Waiting for the patient to report warmth
    3. Injecting contrast with no delay at all
    4. Bolus tracking with the ROI in the distal aorta Correct answer.

    Explanation

    Bolus tracking placed in the distal abdominal aorta triggers the table motion when systemic arterial contrast arrives, accommodating patient-to-patient circulation differences. A fixed delay may scan too early in patients with slow flow.

  84. Question 84Imaging Procedures

    Which preparation is commonly used before a coronary CTA to improve image quality?

    1. Caffeine to stabilize the cardiac rhythm
    2. Nitroglycerin to raise the heart rate
    3. A beta-blocker to lower the heart rate Correct answer.
    4. A full meal shortly before the scan

    Explanation

    Lower, steady heart rates reduce coronary motion and allow imaging within a single diastolic phase. Beta-blockers are given when necessary and nitroglycerin is used to dilate the coronaries, not to raise the heart rate.

  85. Question 85Imaging Procedures

    Which adjustment best reduces dose for a pediatric chest CT while maintaining diagnostic quality?

    1. Increasing the pitch to 0.5
    2. Lowering kVp according to patient size Correct answer.
    3. Adding a second acquisition in expiration
    4. Using 5-mm slices for all children

    Explanation

    Children have smaller cross-sections and lower attenuation, so reducing kVp according to size maintains contrast-to-noise while substantially lowering dose. Size-based protocols also adjust tube current to patient dimensions.

  86. Question 86Imaging Procedures

    In CT urography, the excretory phase is typically acquired how long after contrast injection?

    1. Immediately after the injection
    2. Approximately 60 seconds after injection
    3. Approximately 5 to 15 minutes after injection Correct answer.
    4. Approximately 30 seconds after injection

    Explanation

    The excretory phase is timed for opacification and distension of the renal collecting systems and ureters, usually between 5 and 15 minutes after injection. Earlier phases are used for corticomedullary and nephrographic assessment.

  87. Question 87Imaging Procedures

    A patient taking metformin is scheduled for a contrast-enhanced CT. What is the standard precaution?

    1. Double the oral contrast dose
    2. Withhold metformin if renal function is impaired Correct answer.
    3. No precaution is needed at any eGFR
    4. Give the contrast by slow infusion over 10 minutes

    Explanation

    Current guidance advises withholding metformin when renal function is reduced or acute kidney injury is present, because impaired clearance of the drug with contrast-induced nephropathy raises the risk of lactic acidosis. Patients with normal renal function generally do not need to stop the medication.

  88. Question 88Imaging Procedures

    Which reconstruction kernel is used to evaluate fine bony detail?

    1. Standard soft tissue kernel
    2. Smoothing kernel
    3. High-spatial-frequency bone kernel Correct answer.
    4. Lung kernel

    Explanation

    Bone kernels emphasize edges and high spatial frequencies, sharpening trabecular and cortical detail at the cost of increased noise. Soft tissue and smoothing kernels trade that sharpness for lower noise.

  89. Question 89Imaging Procedures

    A high-resolution CT of the chest is ordered for suspected interstitial lung disease. Which technique is characteristic of this study?

    1. Thick sections with a smooth kernel
    2. Contrast-enhanced 5-mm sections in inspiration
    3. Cine acquisition through the carina
    4. Thin sections with edge-enhancing reconstruction Correct answer.

    Explanation

    High-resolution chest CT uses thin collimation, a high-spatial-frequency reconstruction kernel, and often prone and expiratory sequences to show fine interstitial detail and air trapping. Intravenous contrast is generally not required.

  90. Question 90Imaging Procedures

    A coronary artery calcium score is acquired using which technique?

    1. Bolus-tracked acquisition in the arterial phase
    2. Retrospective gating with IV contrast
    3. Spiral acquisition with a pitch of 1.5
    4. Prospective ECG triggering without IV contrast Correct answer.

    Explanation

    Calcium scoring uses a non-contrast, prospectively ECG-triggered axial acquisition at a fixed phase of the cardiac cycle. This minimizes dose and motion while preserving calcium attenuation values for scoring.

  91. Question 91Imaging Procedures

    Which practice improves polyp detection during CT colonography?

    1. Imaging in both supine and prone positions Correct answer.
    2. Scanning only in the supine position
    3. Using IV contrast as the sole bowel preparation
    4. Using thick 10-mm sections for review

    Explanation

    Acquiring the colon in both supine and prone positions redistributes gas and residual fluid so that segments collapsed or obscured in one position are distended in the other. This dual positioning significantly improves polyp sensitivity.

  92. Question 92Imaging Procedures

    During a CT-guided core needle biopsy, needle tip position is best confirmed by:

    1. The patient's report of discomfort
    2. The pre-procedure scout image
    3. Fluoroscopic overlay without additional scanning
    4. Limited repeat CT sections through the needle tip Correct answer.

    Explanation

    Short limited scans through the needle tip provide direct visualization of the tip relative to the lesion and surrounding structures. These limited sections keep procedural dose low while confirming accurate placement before sampling.

  93. Question 93Imaging Procedures

    In CT myelography, patient positioning after intrathecal contrast administration is used to:

    1. Prevent seizure activity
    2. Speed systemic absorption of contrast
    3. Reduce the volume of contrast injected
    4. Direct contrast to the region of interest Correct answer.

    Explanation

    Because intrathecal contrast is subject to gravity, tilting the table or positioning the patient moves the contrast column toward the level of interest, such as the cervical or lumbar spine. This allows the required segments to be opacified with a smaller injected volume.

  94. Question 94Imaging Procedures

    During a routine head CT, why is the gantry commonly angled relative to the orbitomeatal line?

    1. To shorten the total examination time
    2. To improve gray-white matter contrast
    3. To reduce radiation exposure to the lenses Correct answer.
    4. To increase coverage of the posterior fossa

    Explanation

    Angling the gantry parallel to the skull base and away from the orbits keeps the primary beam from passing directly through the lenses. This reduces lens dose without sacrificing brain coverage, which is determined by the prescribed scan range.

  95. Question 95Imaging Procedures

    For a CT examination of the cervical spine, which positioning best reduces shoulder artifact over the lower cervical levels?

    1. Prone position with arms extended forward
    2. Arms down with shoulders pulled inferiorly Correct answer.
    3. Arms raised fully above the head
    4. Arms crossed over the chest

    Explanation

    Pulling the shoulders inferiorly moves the dense shoulder girdle out of the lateral projection through the lower cervical spine. This reduces streak artifact and improves visualization of the lower cervical levels.

  96. Question 96Imaging Procedures

    A routine CT of the chest is prescribed. Which breathing instruction is most appropriate?

    1. Breathe normally throughout the acquisition
    2. Take a deep breath and cough
    3. Exhale fully and hold
    4. Hold at full inspiration Correct answer.

    Explanation

    A full inspiratory breath hold maximizes lung volumes and reduces respiratory motion during the acquisition. It also improves the consistency of lung density and lesion position.

  97. Question 97Imaging Procedures

    Which oral preparation is preferred for CT enterography to distend the small bowel without masking mucosal enhancement?

    1. Water or low-concentration barium Correct answer.
    2. High-density barium suspension
    3. Effervescent granules alone
    4. Nothing by mouth

    Explanation

    Neutral or low-attenuation oral contrast distends the small bowel without creating high-density material that can obscure mucosal enhancement. Water and low-concentration barium are commonly used for this purpose.

  98. Question 98Imaging Procedures

    For CT angiography of the head and neck, where is the bolus-tracking region of interest usually placed?

    1. In the superior sagittal sinus
    2. In the external carotid artery
    3. In the internal jugular vein
    4. In the aortic arch Correct answer.

    Explanation

    The aortic arch is a large, central vessel that opacifies before the head and neck arteries. Tracking there allows the acquisition to begin as contrast reaches the cervical and intracranial circulation.

  99. Question 99Imaging Procedures

    After CT pulmonary angiography, CT venography of the lower extremities is timed to opacify which vessels?

    1. Lymphatic channels
    2. Lower extremity arteries
    3. Deep veins of the legs Correct answer.
    4. Portal vein

    Explanation

    CT venography is performed after a delay that allows contrast to return through the venous system. The goal is to opacify the deep veins of the legs to detect deep venous thrombosis.

  100. Question 100Imaging Procedures

    Sublingual nitroglycerin is administered before coronary CTA primarily to:

    1. Prevent ventricular arrhythmias
    2. Slow the heart rate
    3. Dilate the coronary arteries Correct answer.
    4. Reduce the volume of contrast needed

    Explanation

    Nitroglycerin produces coronary vasodilation, which improves visualization of the distal coronary arteries and small branches. Heart rate control is typically achieved with beta-blockers rather than nitroglycerin.

  101. Question 101Imaging Procedures

    A dual-energy CT of the abdomen is acquired after IV contrast. What does a virtual noncontrast reconstruction provide?

    1. A scan acquired with no radiation dose
    2. An iodine-subtracted precontrast-like image Correct answer.
    3. An image with improved temporal resolution
    4. A bone-selective image with soft tissue removed

    Explanation

    Dual-energy material decomposition can subtract iodine signal and create an image that resembles a true noncontrast acquisition. This can reduce the need for a separate precontrast phase.

  102. Question 102Imaging Procedures

    In CT perfusion of the brain, which region represents tissue that is hypoperfused but potentially salvageable?

    1. Area of old infarction with no metabolic activity
    2. Area with matched severe reduction in blood flow and blood volume
    3. Area of normal perfusion
    4. Area with prolonged transit time and preserved blood volume Correct answer.

    Explanation

    The ischemic penumbra is tissue with delayed transit, such as elevated MTT or Tmax, but preserved cerebral blood volume. The infarct core instead shows matched reductions in both blood flow and blood volume.

  103. Question 103Imaging Procedures

    What is the primary purpose of automatic exposure control in CT?

    1. To eliminate the need for a scout image
    2. To reduce the number of required reconstructions
    3. To shorten contrast injection duration
    4. To adjust tube current and lower dose Correct answer.

    Explanation

    Automatic exposure control modulates tube current based on patient attenuation so that diagnostic image quality is maintained at a lower radiation dose. It does not replace the scout image or alter contrast injection timing.

  104. Question 104Imaging Procedures

    In helical CT, increasing pitch above 1 generally produces which effect?

    1. Shorter scan time and lower patient dose Correct answer.
    2. Guaranteed improvement in low-contrast resolution
    3. Higher patient dose
    4. Longer scan time

    Explanation

    Higher pitch moves the table faster relative to tube rotation, reducing scan time and usually lowering dose. Low-contrast resolution may actually decrease if photon statistics become insufficient.

  105. Question 105Imaging Procedures

    A reconstruction field of view smaller than the scan field of view will:

    1. Improve spatial resolution of centered anatomy Correct answer.
    2. Reduce spatial resolution
    3. Change the window level automatically
    4. Increase patient dose

    Explanation

    A smaller reconstruction field of view places more pixels over the centered anatomy, improving spatial resolution in that region. It does not change the radiation dose delivered during acquisition.

  106. Question 106Imaging Procedures

    Which window setting is most appropriate for evaluating liver parenchyma on a contrast-enhanced abdominal CT?

    1. Width 350-400 HU, level 40-50 HU Correct answer.
    2. Width 80-100 HU, level 30-40 HU
    3. Width 1500-2000 HU, level 400-500 HU
    4. Width 1000-1500 HU, level -600 HU

    Explanation

    Soft tissue abdominal structures such as the liver are evaluated with a medium window width and level near soft tissue attenuation. A width of about 350-400 HU and level of about 40-50 HU provides appropriate contrast.

  107. Question 107Imaging Procedures

    In a hemodynamically stable blunt trauma patient, a whole-body CT protocol typically includes:

    1. Contrast-enhanced head and noncontrast chest only
    2. Noncontrast head only
    3. Noncontrast head plus contrast-enhanced torso Correct answer.
    4. Noncontrast chest and abdomen only

    Explanation

    A whole-body trauma protocol generally combines a noncontrast head CT with contrast-enhanced imaging of the neck, chest, abdomen, and pelvis. This detects intracranial hemorrhage and vascular or solid-organ injury.

  108. Question 108Imaging Procedures

    For a young child undergoing CT without sedation, which approach best reduces motion artifact?

    1. Increase the scan time to allow movement
    2. Perform the scan during crying
    3. Ask the child to hold still without preparation
    4. Feed-and-swaddle with a caregiver present Correct answer.

    Explanation

    Feeding, swaddling, and having a caregiver nearby help the child remain calm and still without sedation. This reduces motion and often avoids the need for pharmacologic sedation.

  109. Question 109Imaging Procedures

    Which eGFR value is commonly used as a threshold below which iodinated IV contrast requires careful risk-benefit review?

    1. 30 mL/min/1.73 m² Correct answer.
    2. 45 mL/min/1.73 m²
    3. 60 mL/min/1.73 m²
    4. 90 mL/min/1.73 m²

    Explanation

    An eGFR below 30 mL/min/1.73 m² is commonly used as the threshold for increased concern about contrast-associated acute kidney injury. At this level, the need for contrast should be reviewed against the diagnostic benefit.

  110. Question 110Imaging Procedures

    During contrast-enhanced CT, a large volume of contrast extravasates into the forearm. What is the appropriate initial management?

    1. Apply a warm compress and discharge immediately
    2. Restart the injection in the same vein
    3. Continue the injection and massage the site
    4. Stop injection, elevate the arm, and apply cold Correct answer.

    Explanation

    The injection should be stopped immediately, the limb elevated, and a cold compress applied to limit swelling and discomfort. The patient should be monitored and the event documented.

  111. Question 111Imaging Procedures

    For a patient with suspected small bowel obstruction, why is oral contrast often avoided?

    1. It causes immediate renal failure
    2. It improves bowel distention more than needed
    3. It may delay surgery and raise aspiration risk Correct answer.
    4. It obscures the bowel wall

    Explanation

    Oral contrast can delay definitive surgical management and increases the risk of aspiration if the patient vomits. CT without oral contrast is usually sufficient to identify obstruction and its complications.

  112. Question 112Imaging Procedures

    Rectal administration of contrast is most useful for evaluating which structure?

    1. Biliary tree
    2. Distal rectum and anal canal Correct answer.
    3. Urinary bladder
    4. Small bowel

    Explanation

    Rectal contrast distends and opacifies the distal rectum and anal canal, improving evaluation of those structures. It does not routinely reach the small bowel or biliary tree.

  113. Question 113Imaging Procedures

    When performing CT-guided percutaneous drainage of an abdominal abscess, which technique best confirms catheter tip position?

    1. Ultrasound of the flank
    2. Palpation of the catheter hub
    3. Repeat limited CT at the drainage site Correct answer.
    4. Fluoroscopy with a small amount of contrast

    Explanation

    A limited repeat CT through the drainage site directly visualizes the catheter tip within the collection. This confirms satisfactory placement before the procedure is concluded.

  114. Question 114Imaging Procedures

    A patient with bilateral hip replacements needs a CT of the pelvis. Which measure best reduces metal artifact?

    1. Increase the reconstructed slice thickness
    2. Reduce the field of view to the prostheses only
    3. Acquire images without any reconstruction filter
    4. Thin slices with metal artifact reduction Correct answer.

    Explanation

    Thin slices combined with a metal artifact reduction algorithm reduce photon starvation and streak artifact from prostheses. Thicker slices and limited fields of view do not address the underlying artifact.

  115. Question 115Imaging Procedures

    For a CT examination of the orbits, which practice most reduces radiation dose to the lens?

    1. Angle the gantry and limit the scan range Correct answer.
    2. Increase the tube current
    3. Increase the reconstructed slice thickness considerably
    4. Use a bone reconstruction kernel

    Explanation

    Angling the gantry away from the lenses and restricting the scan range to the orbits reduces direct lens exposure. Increasing tube current or using bone kernels does not reduce lens dose and may increase it.

  116. Question 116Imaging Procedures

    For CT angiography of the thoracic aorta to evaluate dissection, which timing is best?

    1. Venous phase with a 90-second delay
    2. Arterial phase with bolus tracking Correct answer.
    3. Noncontrast phase only
    4. Excretory phase with a 5-minute delay

    Explanation

    An arterial phase timed with bolus tracking opacifies the aortic lumen and helps identify the intimal flap and false lumen. Venous or excretory delays provide less consistent aortic enhancement.

  117. Question 117Imaging Procedures

    A renal mass is being evaluated with multiphase CT. Which phase best characterizes the mass's enhancement relative to the renal cortex?

    1. Corticomedullary phase Correct answer.
    2. Noncontrast phase with no iodine
    3. Nephrographic phase after a delay
    4. Excretory phase at five minutes

    Explanation

    During the corticomedullary phase, the renal cortex enhances strongly while the medulla is less enhanced, making it easier to compare mass enhancement with cortical enhancement. This phase is useful for characterizing hypervascular renal masses.

  118. Question 118Imaging Procedures

    CT cystography for suspected bladder rupture is performed by:

    1. Injecting contrast intravenously and imaging immediately
    2. Using only air to distend the bladder
    3. Administering oral contrast 2 hours before scanning
    4. Retrograde instillation of dilute iodinated contrast Correct answer.

    Explanation

    CT cystography requires retrograde filling of the bladder with dilute iodinated contrast to detect leakage. Intravenous or oral contrast does not provide the controlled bladder distention needed for this diagnosis.

  119. Question 119Imaging Procedures

    What is the primary purpose of acquiring a scout (topogram) image before a helical CT acquisition?

    1. To reconstruct coronal and sagittal reformats of the imaged volume
    2. To confirm that intravenous access is patent before injection
    3. To measure renal function before intravenous contrast administration
    4. To plan the scan range and supply attenuation data for automatic exposure control Correct answer.

    Explanation

    The scout is a low-dose projection radiograph used to prescribe the start and end of the scan and to give the scanner attenuation information for tube current modulation. It also serves as a reference image on which technologists can mark ranges. It does not provide reconstructed cross-sectional data or functional information.

  120. Question 120Imaging Procedures

    Increasing the window width on a CT display while leaving the window level unchanged will produce which effect?

    1. A change in the measured CT numbers within a region of interest
    2. Increased spatial resolution
    3. Decreased displayed image contrast Correct answer.
    4. Increased displayed image contrast

    Explanation

    Window width defines the range of Hounsfield units mapped to the available gray scale. Widening this range assigns more gray shades and reduces apparent contrast, while the window level sets the center of that range. Window settings alter display only and never change the underlying attenuation values.

  121. Question 121Imaging Procedures

    A reconstruction is changed from 5 mm to 1 mm slice thickness with all other parameters held constant. What is the primary result?

    1. Increased contrast-to-noise ratio
    2. Reduced image noise
    3. Reduced radiation dose to the patient
    4. Improved spatial resolution along the z-axis Correct answer.

    Explanation

    Thinner sections sample the patient volume more finely along the longitudinal axis, improving z-axis spatial resolution and reformat quality. The trade-off is that fewer photons contribute to each voxel, so noise rises and contrast-to-noise ratio falls. Dose and noise do not decrease when thinner slices are reconstructed.

  122. Question 122Imaging Procedures

    For a routine CT of the abdomen and pelvis using positive oral contrast, when should the patient begin drinking the contrast?

    1. Immediately before entering the scan room
    2. The evening before the examination
    3. About 10 minutes before scanning
    4. About 45 to 60 minutes before scanning Correct answer.

    Explanation

    Positive oral contrast must transit the stomach and proximal small bowel to opacify distal small bowel loops that could otherwise be mistaken for pathology. Divided doses given over roughly 45 to 60 minutes achieve adequate filling, with longer lead times used when colonic opacification is required. Immediate or very short delays opacify only the stomach and duodenum.

  123. Question 123Imaging Procedures

    How is a patient typically positioned for a routine CT examination of the head?

    1. Lateral decubitus with the head elevated 30 degrees
    2. Supine with the head rotated 45 degrees to the right
    3. Supine with the head in a head holder and centered at gantry isocenter Correct answer.
    4. Prone with the forehead resting on the table

    Explanation

    Routine head CT is performed with the patient supine, the head supported in a holder, and the head centered at isocenter so that the beam passes symmetrically and dose to the orbits is limited. Slight chin tuck keeps the orbits out of the primary beam. Rotation or off-centering degrades image quality and increases dose.

  124. Question 124Imaging Procedures

    In helical CT, pitch is calculated as which ratio?

    1. Reconstructed slice thickness divided by detector row width
    2. Table travel per gantry rotation divided by the total collimated beam width Correct answer.
    3. Tube current during helical scanning divided by tube current during axial scanning
    4. Gantry rotation time divided by total scan time

    Explanation

    Pitch compares the distance the table moves during one gantry rotation with the total width of the collimated beam. A pitch below 1 means overlapping acquisitions, while values above 1 leave gaps in the sampled volume and can degrade image quality if not compensated. Pitch strongly influences dose and scan time in helical mode.

  125. Question 125Imaging Procedures

    Which parameter most directly improves the temporal resolution of a cardiac CT acquisition?

    1. Increasing the reconstructed slice thickness
    2. Reducing tube potential from 120 kVp to 100 kVp
    3. Reducing the gantry rotation time Correct answer.
    4. Increasing pitch to 1.5

    Explanation

    Temporal resolution for a half-scan reconstruction is approximately half the gantry rotation time, so faster rotation freezes cardiac motion more effectively. Thicker slices, higher pitch, and lower tube potential affect noise, coverage, and dose but not temporal resolution. Beta-blockade and multisegment reconstruction are other strategies for motion suppression.

  126. Question 126Imaging Procedures

    In CT urography, at approximately what delay after intravenous contrast injection is the excretory phase acquired?

    1. 90 seconds
    2. 40 seconds
    3. 5 to 10 minutes Correct answer.
    4. 15 seconds

    Explanation

    The excretory phase depends on glomerular filtration and peristaltic transport of opacified urine into the collecting systems and ureters, which typically requires 5 to 10 minutes. Earlier delays capture the corticomedullary and nephrographic phases of the kidney. Additional delayed images or prone views may be added when a ureteral segment is not distended.

  127. Question 127Imaging Procedures

    Automated bolus-tracking software initiates a CT acquisition when which condition is met?

    1. A preset attenuation threshold is reached in a monitoring ROI Correct answer.
    2. The patient's heart rate exceeds a preset value
    3. A predetermined volume of contrast has been injected
    4. A fixed time has elapsed since the start of injection

    Explanation

    Bolus tracking places a monitoring region of interest over a target vessel and triggers the scan once the attenuation in that region crosses a defined threshold. This accounts for variations in cardiac output and injection rate better than fixed delays. A post-threshold diagnostic delay can be added to allow optimal vessel or organ enhancement.

  128. Question 128Imaging Procedures

    Why is CT colonography performed with the patient imaged in both the supine and prone positions?

    1. To redistribute gas and fluid so lesions hidden in one view are seen in the other Correct answer.
    2. To reduce radiation dose by splitting the acquisition into two halves
    3. To shorten the examination by covering the colon twice as quickly
    4. To improve enhancement of the colonic wall

    Explanation

    Changing position moves residual fluid and distends different segments, so a polyp obscured by fluid or an underdistended fold in one view may be visible in the other. This improves sensitivity for small lesions without additional contrast. The trade-off is roughly double the radiation dose compared with a single pass.

  129. Question 129Imaging Procedures

    Which acquisition approach best supports high-quality coronal and sagittal reformations of an abdominal CT?

    1. Thick slices with a large reconstruction interval
    2. Thick slices reconstructed with a bone kernel
    3. Thin slices reconstructed with 50% overlap Correct answer.
    4. Axial acquisition with 10 mm slice thickness

    Explanation

    Multiplanar reformats are built from stacked axial images, so thin sections with overlapping reconstruction intervals minimize stair-step artifacts and yield near-isotropic data. Thick sections degrade reformats severely regardless of kernel. Overlap does not increase patient dose because it occurs only at reconstruction.

  130. Question 130Imaging Procedures

    Which breathing instruction best limits respiratory motion artifact during a routine chest CT?

    1. Hold the breath at deep inspiration Correct answer.
    2. Cough forcefully just before the acquisition
    3. Breathe rapidly in and out throughout the scan
    4. Hold the breath at end-expiration

    Explanation

    A reproducible maximal inspiration (or quiet inspiration, depending on protocol) suspends diaphragmatic motion during the acquisition and gives consistent anatomy between phases. End-expiration is less reproducible and lowers lung volumes. Coaching and practice before the scan reduce the chance of a failed breath-hold.

  131. Question 131Imaging Procedures

    How should tube potential and tube current be selected for a pediatric abdominal CT compared with an adult protocol?

    1. Lower kVp and lower mA, scaled to patient size Correct answer.
    2. A higher kVp only, with unchanged mA
    3. The same kVp and mA as adults to avoid noise
    4. A higher mA with a shorter rotation time

    Explanation

    Children have smaller body diameters, so lower tube potential and current maintain adequate photon flux at the detector while substantially reducing dose. Size-based or weight-based protocols, often guided by automatic exposure control, are standard practice. Adult settings applied to a child cause unnecessary dose and offer no diagnostic benefit.

  132. Question 132Imaging Procedures

    A helical acquisition uses a CTDIvol of 10 mGy over a scan length of 30 cm. What is the dose-length product?

    1. 3000 mGy·cm
    2. 300 mGy·cm Correct answer.
    3. 0.33 mGy·cm
    4. 10 mGy·cm

    Explanation

    Dose-length product equals CTDIvol multiplied by the scanned length, so 10 mGy times 30 cm gives 300 mGy·cm. DLP captures both the intensity and extent of exposure and is used with conversion coefficients to estimate effective dose. CTDIvol alone describes only the dose per unit length.

  133. Question 133Imaging Procedures

    A dual-source scanner has two X-ray tubes mounted at 90 degrees to each other, and each tube completes a rotation in 0.28 seconds. What is the approximate temporal resolution?

    1. 35 ms
    2. 140 ms
    3. 70 ms Correct answer.
    4. 280 ms

    Explanation

    With the two tubes offset by 90 degrees, the dataset needed for a half-scan reconstruction is acquired in one quarter of a rotation. A 0.28-second rotation therefore yields about 70 ms of temporal resolution. Single-source scanners with the same rotation time achieve roughly 140 ms.

  134. Question 134Imaging Procedures

    An abdominal CT is reconstructed with a sharp (high-frequency) kernel instead of a smooth kernel. What is the expected result?

    1. Higher image noise with sharper edge definition Correct answer.
    2. Reduced spatial resolution with blurred tissue edges
    3. Lower CT numbers within soft tissue
    4. Lower image noise with improved low-contrast detectability

    Explanation

    Sharp kernels emphasize high spatial frequencies, which improves edge and bone detail but amplifies noise and can worsen low-contrast detectability. Smooth kernels suppress noise at the cost of spatial resolution and are preferred for soft-tissue evaluation. Kernel choice alters noise texture and resolution but does not meaningfully shift CT numbers.

  135. Question 135Physics and Instrumentation

    On the Hounsfield scale used in CT, water is assigned a CT number of:

    1. 0 HU Correct answer.
    2. -1000 HU
    3. +100 HU
    4. +1000 HU

    Explanation

    The Hounsfield scale is defined with water as the reference material at 0 HU, with the linear attenuation coefficient of water serving as the divisor. Air and dense bone anchor the extremes of the scale at approximately -1000 HU and +1000 HU.

  136. Question 136Physics and Instrumentation

    The primary function of a slip ring in a CT gantry is to:

    1. Transfer power and data to a continuously rotating gantry Correct answer.
    2. Remove low-energy photons from the beam
    3. Align the detector array with the focal spot
    4. Cool the x-ray tube during long helical scans

    Explanation

    Slip rings are conductive brushes and rings that carry electrical power and data between the stationary frame and the continuously rotating gantry. This eliminates the need to unwind cables, making helical and rapid sequential scanning possible.

  137. Question 137Physics and Instrumentation

    The bowtie filter in a CT scanner is designed chiefly to:

    1. Reduce scatter reaching the detector array
    2. Reduce beam intensity toward the fan periphery Correct answer.
    3. Remove high-energy photons to increase subject contrast
    4. Collimate the beam to the selected slice width

    Explanation

    The bowtie filter is thicker at its edges, so it attenuates the beam more strongly toward the periphery of the fan where the patient is thinner. This compensates for the cylindrical patient shape, reducing peripheral dose and helping equalize detector signal.

  138. Question 138Physics and Instrumentation

    In CT image formation, a pixel represents:

    1. A two-dimensional picture element Correct answer.
    2. The width of a single detector row
    3. The reconstruction field of view
    4. A three-dimensional volume element

    Explanation

    A pixel is a single two-dimensional picture element in the reconstructed image matrix, and each pixel carries a CT number. Multiplying the pixel area by the slice thickness gives the corresponding voxel volume.

  139. Question 139Physics and Instrumentation

    Increasing the window width on a displayed CT image will:

    1. Improve the spatial resolution
    2. Increase the displayed contrast
    3. Change the brightness of the image
    4. Decrease the displayed contrast Correct answer.

    Explanation

    Window width defines the range of CT numbers mapped to the full gray scale, so widening it compresses that range and lowers displayed contrast. Window level, by contrast, sets the center of that range and therefore brightness.

  140. Question 140Physics and Instrumentation

    Which parameter most directly determines the temporal resolution of a single-source CT scanner?

    1. The displayed field of view
    2. The reconstruction kernel selected
    3. The gantry rotation time Correct answer.
    4. The tube current-time product

    Explanation

    Temporal resolution in CT is governed by how long the gantry takes to complete the data acquisition needed for a reconstruction. Shorter rotation times shorten that acquisition window and reduce motion blur from a beating heart or moving patient.

  141. Question 141Physics and Instrumentation

    Increasing the tube current-time product (mAs) while all other factors are held constant primarily:

    1. Increases spatial resolution
    2. Raises the CT number of bone
    3. Widens the reconstruction field of view
    4. Reduces image noise Correct answer.

    Explanation

    Tube current-time product determines the number of photons reaching the detectors, and image noise from quantum statistics varies inversely with the square root of that photon count. Raising mAs therefore lowers noise without shifting CT numbers.

  142. Question 142Physics and Instrumentation

    Which component of a CT scanner converts the transmitted x-ray beam into an electrical signal?

    1. The collimator
    2. The slip ring
    3. The bowtie filter
    4. The detector array Correct answer.

    Explanation

    The detector array absorbs transmitted photons and produces an electrical signal proportional to the measured intensity. Scintillation detectors do this via light plus a photodiode, while gas detectors ionize xenon directly.

  143. Question 143Physics and Instrumentation

    A helical scan uses a table feed of 15 mm per gantry rotation with a total collimated beam width of 10 mm. The pitch is:

    1. 0.67
    2. 0.15
    3. 1.5 Correct answer.
    4. 15

    Explanation

    Pitch equals the table travel per gantry rotation divided by the total collimated beam width. Here 15 mm divided by 10 mm gives a pitch of 1.5, which corresponds to overlapping helical paths.

  144. Question 144Physics and Instrumentation

    A helical acquisition is performed at 200 mA with a 0.5 s rotation time and a pitch of 1.0. If the pitch is increased to 2.0 with mA and rotation time unchanged, the effective mAs is:

    1. 100 mAs
    2. 25 mAs
    3. 50 mAs Correct answer.
    4. 200 mAs

    Explanation

    Effective mAs equals tube current times rotation time divided by pitch, so 200 mA x 0.5 s divided by 2.0 gives 50 mAs. Increasing pitch spreads the same tube output over a longer volume, lowering the effective mAs per slice.

  145. Question 145Physics and Instrumentation

    Beam hardening artifact typically appears in a CT image as:

    1. Cupping or dark bands between dense structures Correct answer.
    2. Streaks radiating outward from a dense metallic implant
    3. Concentric rings centred on the isocentre
    4. Uniformly increased noise across the image

    Explanation

    As a polychromatic beam traverses dense material, lower-energy photons are preferentially absorbed so the beam becomes harder and more penetrating. Reconstruction assumes a single energy, so thick dense regions reconstruct artificially low, producing cupping or dark bands between dense structures.

  146. Question 146Physics and Instrumentation

    Concentric ring artifacts on a CT image most commonly indicate:

    1. Photon starvation through the shoulders
    2. Patient motion during the acquisition
    3. An incorrect window level setting
    4. A miscalibrated or defective detector channel Correct answer.

    Explanation

    Each detector channel contributes to every projection at a fixed angle in the fan, so an error in one channel traces a circle about the isocentre. Calibration drift or failure of a single detector element therefore produces a ring.

  147. Question 147Physics and Instrumentation

    Partial volume averaging has the greatest effect on which of the following?

    1. A large homogeneous abdominal organ
    2. A structure scanned with a 0.5 mm slice
    3. A structure lying outside the scan field of view
    4. An object similar in size to the slice thickness Correct answer.

    Explanation

    Partial volume averaging occurs when a voxel contains more than one tissue type, so the reported CT number is an average of the materials present. This is most pronounced when object size is comparable to or smaller than the slice thickness.

  148. Question 148Physics and Instrumentation

    Which reconstruction kernel is most appropriate for demonstrating fine bony detail of the temporal bone?

    1. A strongly smoothing noise-reducing kernel
    2. A low-spatial-frequency kernel
    3. A sharp, high-spatial-frequency kernel Correct answer.
    4. A smooth soft-tissue kernel

    Explanation

    Sharp or bone kernels emphasize high spatial frequencies, increasing edge sharpness and detail visibility at the cost of higher image noise. Smooth kernels do the opposite, favoring low-contrast detectability in soft tissue.

  149. Question 149Physics and Instrumentation

    A 350 mm field of view is reconstructed into a 512 x 512 image matrix. The resulting pixel size is approximately:

    1. 0.14 mm
    2. 1.37 mm
    3. 0.68 mm Correct answer.
    4. 0.35 mm

    Explanation

    Pixel size equals the reconstruction field of view divided by the matrix dimension, so 350 mm divided by 512 gives about 0.68 mm. Reducing the field of view or enlarging the matrix decreases pixel size and improves in-plane detail.

  150. Question 150Physics and Instrumentation

    In a multidetector-row CT scanner, the number of images reconstructed per gantry rotation depends primarily on:

    1. The anode rotation speed
    2. Detector configuration and slice width Correct answer.
    3. The focal spot size
    4. The reconstruction field of view

    Explanation

    How many slices can be produced per rotation is set by the number and width of detector rows in use and by the reconstructed slice width chosen. Wider detector coverage or thinner reconstructed slices yield more images per rotation.

  151. Question 151Physics and Instrumentation

    The CTDIvol reported on a scanner console represents the:

    1. Total dose-length product for the entire series
    2. Effective dose in millisieverts
    3. Peak skin dose at the isocentre
    4. Volume-averaged dose index for the protocol Correct answer.

    Explanation

    CTDIvol is the weighted CTDI divided by pitch, giving a volume-averaged dose index for the selected protocol in milligrays. Multiplying it by scan length yields the dose-length product, which is then converted to effective dose using body-region coefficients.

  152. Question 152Physics and Instrumentation

    The primary purpose of automatic exposure control (tube current modulation) in CT is to:

    1. Improve the spatial resolution of the reconstruction
    2. Eliminate beam-hardening artifacts
    3. Maintain consistent image noise with lower dose Correct answer.
    4. Shorten the total scan time

    Explanation

    Tube current modulation adjusts mA along the scan based on the attenuation of the region being imaged, so photon flux at the detector stays near the level needed for the prescribed noise. This avoids overexposing thin or low-attenuation regions and lowers total dose.

  153. Question 153Physics and Instrumentation

    Increasing pitch above 1 during a helical acquisition, with all other parameters unchanged, generally:

    1. Leaves dose and noise essentially unchanged
    2. Lowers dose while increasing image noise Correct answer.
    3. Raises dose in direct proportion to pitch
    4. Lowers noise while raising patient dose

    Explanation

    Higher pitch moves the table farther per rotation, so the same tube output is distributed over a longer volume of tissue, reducing dose per slice. Because fewer photons are available per reconstructed slice, image noise increases.

  154. Question 154Physics and Instrumentation

    Lowering the tube voltage from 120 kVp to 80 kVp for a contrast-enhanced CT acquisition generally:

    1. Leaves iodine attenuation essentially unchanged
    2. Reduces photoelectric interactions in iodine
    3. Increases iodine attenuation and improves contrast Correct answer.
    4. Reduces iodine attenuation and lowers contrast

    Explanation

    Iodine's k-edge lies near 33 keV, so lowering the effective beam energy moves it closer to that edge and increases photoelectric interaction probability. The result is stronger iodine attenuation and greater contrast enhancement per unit of iodine.

  155. Question 155Physics and Instrumentation

    Insufficient sampling of projection data during a CT acquisition can produce which artifact?

    1. A step artifact at the start of a helical scan
    2. Cupping of central CT numbers
    3. Streaks extending from high-contrast boundaries Correct answer.
    4. Concentric rings about the isocentre

    Explanation

    When projections or ray samples are too few for the object's frequency content, the reconstruction undersamples sharp changes in attenuation, an effect called aliasing. It appears as fine streaks emanating from high-contrast edges such as bone or air interfaces.

  156. Question 156Physics and Instrumentation

    If all other factors remain constant, increasing mAs by a factor of 4 reduces the standard deviation of image noise by a factor of approximately:

    1. 2 Correct answer.
    2. 4
    3. 1.4
    4. 16

    Explanation

    Quantum noise is proportional to the reciprocal of the square root of the number of detected photons, and photon count scales with mAs. Quadrupling mAs therefore halves the noise standard deviation.

  157. Question 157Physics and Instrumentation

    Which change would most improve longitudinal (z-axis) spatial resolution in a multidetector-row CT scan?

    1. Increasing pitch beyond 2
    2. Decreasing the reconstructed slice thickness Correct answer.
    3. Increasing the reconstruction field of view
    4. Increasing the reconstructed slice thickness

    Explanation

    Longitudinal resolution is governed by the slice sensitivity profile, which broadens as reconstructed slice thickness increases. Thinner reconstructions sharpen the profile in the z direction, though noise rises because fewer photons contribute to each slice.

  158. Question 158Physics and Instrumentation

    The modulation transfer function of a CT system describes:

    1. Contrast reproduction as a function of spatial frequency Correct answer.
    2. How x-ray photons are converted to light in the detector
    3. The relationship between tube current and patient dose
    4. The ratio of scatter to primary radiation at the detector

    Explanation

    The modulation transfer function plots how faithfully the imaging chain preserves object contrast at each spatial frequency, declining as frequency increases. It is a standard descriptor of spatial resolution performance for the whole system.

  159. Question 159Physics and Instrumentation

    Compared with a xenon gas detector, a solid-state scintillation detector in CT provides:

    1. Slower response time, limiting rotation speed
    2. Better detection efficiency and dose use Correct answer.
    3. Lower detection efficiency, requiring more dose
    4. Poorer spatial resolution at the isocentre

    Explanation

    Solid-state detectors use scintillating crystals coupled to photodiodes and absorb a larger fraction of incident photons than gas detectors do. Higher capture efficiency means more signal per unit dose, allowing lower dose or lower noise for the same exposure.

  160. Question 160Physics and Instrumentation

    On the Hounsfield scale, water is assigned a CT number of:

    1. -1000
    2. +100
    3. +1000
    4. 0 Correct answer.

    Explanation

    The Hounsfield scale is anchored with water at 0 and air at -1000, with dense bone near +1000. CT numbers are derived from linear attenuation coefficients relative to water, so water maps to 0 by definition.

  161. Question 161Physics and Instrumentation

    The CT number of air on the Hounsfield scale is approximately:

    1. -100 HU
    2. -1000 HU Correct answer.
    3. +1000 HU
    4. 0 HU

    Explanation

    Air attenuates x-rays almost not at all, so it occupies the bottom of the Hounsfield scale at -1000 HU. Water is fixed at 0 HU and dense bone near +1000 HU.

  162. Question 162Physics and Instrumentation

    Window width primarily controls which image display characteristic?

    1. Spatial resolution
    2. Displayed contrast Correct answer.
    3. Image brightness
    4. Image noise

    Explanation

    Window width defines how many CT numbers are mapped across the available gray shades, so a narrow width produces a high-contrast image. Window level, not width, governs brightness, and noise is set during acquisition.

  163. Question 163Physics and Instrumentation

    Increasing the window level (center) when viewing a CT image will make the image appear:

    1. More noisy
    2. Darker Correct answer.
    3. Higher in contrast
    4. Brighter

    Explanation

    Window level sets the CT number displayed as mid-gray; raising it places more tissue values below the window, so the image darkens. Contrast is set by window width, not level.

  164. Question 164Physics and Instrumentation

    The volume CT dose index (CTDIvol) is expressed in which unit?

    1. mSv
    2. mGy Correct answer.
    3. mAs
    4. mGy·cm

    Explanation

    CTDIvol is a dose index and is reported in milligray. Milligray-centimeter is the unit of dose-length product, and millisievert is the unit of effective dose.

  165. Question 165Physics and Instrumentation

    Pitch is calculated as table travel per gantry rotation divided by:

    1. The total collimated beam width Correct answer.
    2. The scan field of view
    3. The detector row width
    4. The reconstruction interval

    Explanation

    Pitch equals table feed per rotation divided by the total collimated beam width, so a pitch of 1 means the table advances exactly one beam width per rotation. Detector row width and field of view do not enter the definition.

  166. Question 166Physics and Instrumentation

    The purpose of the scout (localizer) image is to:

    1. Measure patient dose
    2. Reconstruct coronal images
    3. Plan the scan range Correct answer.
    4. Calibrate the detector

    Explanation

    The scout is a projection radiograph used to define the start and end of the scanned volume and to set the exposure technique. It is not a dose measurement or calibration procedure.

  167. Question 167Physics and Instrumentation

    Which component of the CT gantry produces x-ray photons?

    1. Data acquisition system
    2. Detector array
    3. X-ray tube Correct answer.
    4. Collimator

    Explanation

    X-rays are generated inside the tube when electrons from the cathode strike the anode target. The detector array and data acquisition system only measure the transmitted beam, and the collimator shapes it.

  168. Question 168Physics and Instrumentation

    In filtered backprojection, the ramp (high-pass) filter is applied mainly to:

    1. Normalize detector gain
    2. Correct beam hardening
    3. Remove scatter from projection data
    4. Reduce backprojection blurring Correct answer.

    Explanation

    Simple backprojection smears each projection back across the image, producing a blurred result; the ramp filter suppresses low spatial frequencies before backprojection. Scatter rejection and beam-hardening correction are handled by other steps.

  169. Question 169Physics and Instrumentation

    Compared with filtered backprojection, iterative reconstruction primarily:

    1. Improves temporal resolution
    2. Increases slice thickness
    3. Eliminates motion artifact
    4. Lowers noise at a fixed dose Correct answer.

    Explanation

    Iterative reconstruction compares forward projections of an estimated image with the measured data and refines the estimate, allowing noise to be suppressed at a given dose. It does not shorten gantry rotation or remove patient motion.

  170. Question 170Physics and Instrumentation

    The quarter-detector offset (flying focal spot) technique improves image quality by:

    1. Shortening reconstruction time
    2. Reducing beam hardening
    3. Reducing patient dose
    4. Increasing projection sampling Correct answer.

    Explanation

    Shifting the focal spot between readings moves the sampling positions by a quarter detector element, which doubles the number of samples per rotation. The added sampling improves spatial resolution without changing dose.

  171. Question 171Physics and Instrumentation

    Detector geometric efficiency is the fraction of the collimated beam that:

    1. Is converted to light
    2. Reaches the reconstruction computer
    3. Is absorbed by the patient
    4. Strikes the active detector area Correct answer.

    Explanation

    Geometric efficiency compares the active detector area with the total area exposed by the collimated beam, accounting for dead space between elements. It describes how much of the beam is actually used for measurement.

  172. Question 172Physics and Instrumentation

    For a helical scan, CTDIvol is calculated as CTDIw divided by:

    1. Pitch Correct answer.
    2. Rotation time
    3. Slice thickness
    4. mAs

    Explanation

    Because pitch spreads the dose over a longer volume, CTDIvol equals CTDIw divided by pitch. Rotation time and slice thickness do not appear directly in this relationship.

  173. Question 173Physics and Instrumentation

    The dose-length product (DLP) is calculated by multiplying CTDIvol by:

    1. The rotation time
    2. Pitch
    3. The scanned length Correct answer.
    4. The number of detector rows

    Explanation

    DLP is the product of CTDIvol and the scanned length in centimeters, giving units of mGy·cm. It represents the dose index integrated over the imaged volume.

  174. Question 174Physics and Instrumentation

    Using a smaller focal spot generally:

    1. Increases heat capacity
    2. Reduces scatter
    3. Improves spatial resolution Correct answer.
    4. Increases maximum mA

    Explanation

    A smaller focal spot reduces geometric unsharpness, which improves spatial resolution. The trade-off is that the smaller area limits the tube current that can be applied.

  175. Question 175Physics and Instrumentation

    In helical CT, z-axis interpolation broadens the:

    1. Reconstruction matrix
    2. Detector aperture
    3. Field of view
    4. Slice sensitivity profile Correct answer.

    Explanation

    Helical data must be interpolated along z between adjacent rotations, which spreads each reconstructed slice over a greater z extent. The result is a wider slice sensitivity profile than the nominal collimation.

  176. Question 176Physics and Instrumentation

    Photon starvation artifact is most likely when imaging:

    1. A thin pediatric patient
    2. A large patient's shoulders Correct answer.
    3. The lungs at full inspiration
    4. A uniform water phantom

    Explanation

    When the beam is heavily attenuated, as through the shoulders of a large patient, few photons reach the detector and noise rises sharply in those projections. Low-attenuation regions do not starve the detector.

  177. Question 177Physics and Instrumentation

    Increased scattered radiation reaching the detector primarily:

    1. Increases CT number of bone
    2. Reduces reconstruction time
    3. Reduces image contrast Correct answer.
    4. Increases spatial resolution

    Explanation

    Scatter adds a low-frequency signal that carries no anatomic information, so differences between tissues are reduced and contrast falls. Collimation and bowtie filtration are used to limit scatter.

  178. Question 178Physics and Instrumentation

    A voxel differs from a pixel in that a voxel includes:

    1. Only two dimensions
    2. The display window
    3. The slice thickness dimension Correct answer.
    4. The reconstruction kernel

    Explanation

    A pixel is a two-dimensional picture element of the display matrix, whereas a voxel is the three-dimensional volume element whose depth equals the slice thickness. Voxel dimensions therefore combine pixel size and slice thickness.

  179. Question 179Physics and Instrumentation

    Anode heat loading in CT is most commonly expressed in:

    1. kVp
    2. Heat units Correct answer.
    3. mAs
    4. mGy

    Explanation

    Heat units incorporate kVp, mAs, and a generator-specific waveform factor to estimate the heat deposited in the anode. Milligray describes dose, while mAs and kVp describe exposure technique.

  180. Question 180Physics and Instrumentation

    The Nyquist theorem states that to avoid aliasing, sampling frequency must be at least:

    1. Twice the highest signal frequency Correct answer.
    2. Four times the highest signal frequency
    3. Equal to the highest signal frequency
    4. Half the highest signal frequency

    Explanation

    The sampling frequency must exceed twice the highest frequency present in the signal, otherwise the data are undersampled and aliasing occurs. Sampling at exactly the highest frequency provides only one sample per cycle, which is insufficient.

  181. Question 181Physics and Instrumentation

    CTDI100 is measured using which device?

    1. A solid-state point probe
    2. A 100 mm pencil chamber Correct answer.
    3. Thermoluminescent dosimeter chips
    4. An optically stimulated badge

    Explanation

    CTDI100 is defined as the integral of the dose profile over a 100 mm length, which requires a 100 mm pencil ionization chamber positioned in a standard phantom. Point or chip dosimeters sample only individual locations and cannot integrate the whole profile.

  182. Question 182Physics and Instrumentation

    For a fixed detector configuration, decreasing the reconstruction interval (increment) primarily:

    1. Improves z-axis resolution
    2. Reduces patient dose
    3. Shortens reconstruction time
    4. Increases image count Correct answer.

    Explanation

    The reconstruction interval is independent of acquisition, so smaller increments yield more overlapping images from the same data without additional dose. Spatial resolution is set by collimation and interpolation, not by image spacing.

  183. Question 183Physics and Instrumentation

    Which statement about effective dose is correct?

    1. It reflects organ radiosensitivity Correct answer.
    2. It equals CTDIvol times pitch
    3. It is measured by an ion chamber
    4. It is expressed in units of mGy

    Explanation

    Effective dose multiplies absorbed dose in each irradiated organ by a tissue weighting factor and sums over the body, giving a risk-related quantity in mSv. It cannot be measured directly and is not the same as CTDIvol.

  184. Question 184Physics and Instrumentation

    Compared with a bone kernel, a soft-tissue kernel produces images with:

    1. Higher noise, lower spatial resolution
    2. Lower noise, lower spatial resolution Correct answer.
    3. Higher noise, higher spatial resolution
    4. Lower noise, higher spatial resolution

    Explanation

    Kernel choice trades noise against resolution: soft kernels suppress high spatial frequencies, which lowers noise but blurs fine detail. Bone kernels emphasize high frequencies to sharpen edges, at the cost of more noise.

  185. Question 185Physics and Instrumentation

    On the Hounsfield scale used in CT, water is assigned a value of:

    1. +1000 HU
    2. -1000 HU
    3. 0 HU Correct answer.
    4. 1 HU

    Explanation

    CT numbers are defined relative to water, which is set at 0 HU. Air is approximately -1000 HU, and dense bone can approach or exceed +1000 HU.

  186. Question 186Physics and Instrumentation

    The window level (center) on a CT display primarily determines the:

    1. midpoint CT number of the displayed gray scale Correct answer.
    2. maximum tube current used for the scan
    3. range of CT numbers displayed as gray shades
    4. spatial resolution of the image

    Explanation

    Window level sets the center CT number of the displayed gray scale, while window width sets the range of CT numbers shown. Changing level shifts which tissues appear mid-gray.

  187. Question 187Physics and Instrumentation

    For a fixed reconstruction matrix, increasing the reconstruction field of view will:

    1. increase pixel size and improve spatial resolution
    2. decrease pixel size and improve spatial resolution
    3. increase pixel size and lower spatial resolution Correct answer.
    4. decrease pixel size and lower spatial resolution

    Explanation

    Pixel size equals reconstruction field of view divided by matrix size. A larger field of view with the same matrix produces larger pixels, which lowers spatial resolution.

  188. Question 188Physics and Instrumentation

    Which factor is the primary determinant of temporal resolution in a modern CT scanner?

    1. Tube current
    2. Reconstruction kernel
    3. Gantry rotation time Correct answer.
    4. Slice thickness

    Explanation

    Temporal resolution is limited mainly by the time needed to acquire sufficient projection data, which depends on gantry rotation speed. Faster rotation shortens the acquisition time per image.

  189. Question 189Physics and Instrumentation

    Increasing reconstructed slice thickness while keeping other parameters constant will generally:

    1. eliminate partial volume averaging in small structures
    2. decrease partial volume averaging and increase noise
    3. increase partial volume averaging and lower noise Correct answer.
    4. improve z-axis spatial resolution without affecting noise

    Explanation

    A thicker slice averages attenuation over a larger volume, so partial volume averaging increases. It also includes more photons per reconstructed slice, which generally lowers image noise.

  190. Question 190Physics and Instrumentation

    Noise is reduced to approximately what fraction when mAs is quadrupled?

    1. 1/4
    2. 1/8
    3. 1/16
    4. 1/2 Correct answer.

    Explanation

    CT image noise is inversely proportional to the square root of the number of detected photons. Quadrupling mAs approximately quadruples photons, so noise falls by a factor of two.

  191. Question 191Physics and Instrumentation

    Increasing tube potential (kVp) in CT generally:

    1. decreases photon energy and raises soft-tissue contrast
    2. raises photon penetration and lowers tissue contrast Correct answer.
    3. has no effect on dose or image contrast
    4. increases beam hardening and reduces penetration

    Explanation

    Higher kVp increases the mean photon energy, so the beam penetrates more effectively. Because photoelectric interactions decrease relative to Compton interactions, soft-tissue contrast generally decreases.

  192. Question 192Physics and Instrumentation

    The bowtie filter in a CT scanner is used mainly to:

    1. shape the beam profile and reduce peripheral dose Correct answer.
    2. equalize detector gain across the detector row
    3. reduce scatter generated in the gantry housing
    4. increase the number of photons reaching the detector periphery

    Explanation

    A bowtie filter attenuates the beam more at its edges and less centrally. This shapes the beam for the patient's cross-section and reduces dose to superficial tissues.

  193. Question 193Physics and Instrumentation

    Automatic exposure control (AEC) in CT adjusts tube current primarily to:

    1. reduce the number of detector rows used for each slice
    2. keep the CT number of water fixed at zero for all scans
    3. maintain a selected image noise level across the scan Correct answer.
    4. prevent aliasing artifacts in the reconstructed image

    Explanation

    AEC modulates tube current according to patient attenuation so that a target image noise level is maintained. It does not change the CT number calibration or detector row count.

  194. Question 194Physics and Instrumentation

    Beam hardening artifact in CT most typically appears as:

    1. bright streaks radiating from dense bone
    2. dark bands or streaks between dense objects Correct answer.
    3. a ring around the isocenter
    4. fine grain mottle in low-attenuation regions

    Explanation

    Beam hardening occurs because lower-energy photons are preferentially absorbed, so the beam becomes harder as it passes through dense material. This can produce dark bands or streaks between dense objects unless corrected.

  195. Question 195Physics and Instrumentation

    A reconstruction with isotropic voxels is most important for:

    1. high-quality coronal and sagittal reformats Correct answer.
    2. shortening gantry rotation time
    3. increasing the displayed matrix size
    4. reducing radiation dose

    Explanation

    Isotropic voxels have equal dimensions in all three directions, so reformats in coronal, sagittal, or oblique planes retain spatial resolution. Anisotropic voxels produce poorer reformats.

  196. Question 196Physics and Instrumentation

    In a solid-state CT detector, the scintillator material primarily:

    1. rotates the anode
    2. stores image data
    3. converts x-ray photons to light Correct answer.
    4. collimates the x-ray beam

    Explanation

    The scintillator absorbs x-ray photons and emits light, which is then converted to an electrical signal by a photodiode. Collimation and anode rotation are performed by other components.

  197. Question 197Physics and Instrumentation

    Partial volume averaging is most likely to cause an inaccurate CT number when:

    1. the reconstruction matrix is increased to 512
    2. the gantry rotates faster than one second
    3. the tube current is doubled during the scan
    4. a small structure fills only part of a voxel Correct answer.

    Explanation

    Each voxel represents an average attenuation of all materials within it. When a small structure occupies only part of a voxel, its CT number is averaged with surrounding tissue and may be inaccurate.

  198. Question 198Physics and Instrumentation

    In a dual-source CT scanner with two x-ray tubes mounted at 90 degrees, the temporal resolution for a single acquisition is approximately:

    1. one quarter of a gantry rotation Correct answer.
    2. one full gantry rotation time
    3. one half of a gantry rotation
    4. twice the gantry rotation time

    Explanation

    A single-source system typically requires about 180 degrees of rotation for reconstruction, giving half-rotation temporal resolution. With two sources offset by 90 degrees, complementary data can be acquired in about one quarter of a rotation.

  199. Question 199Physics and Instrumentation

    In a single-detector-row CT scanner, the minimum slice thickness is determined primarily by:

    1. tube current and exposure time
    2. collimation and detector width Correct answer.
    3. gantry rotation speed and pitch
    4. reconstruction matrix size

    Explanation

    Slice thickness is limited by the width of the collimated x-ray beam and the detector aperture. Reconstruction cannot create a slice thinner than the acquired beam profile allows.

  200. Question 200Physics and Instrumentation

    For a helical scan, increasing pitch from 1 to 2 while holding mAs and collimation constant will generally:

    1. decrease patient dose and improve z-axis resolution
    2. increase patient dose and improve z-axis resolution
    3. leave dose unchanged and increase slice thickness
    4. reduce patient dose and broaden the slice profile Correct answer.

    Explanation

    Higher pitch moves the table faster, so fewer photons are applied per unit length and patient dose generally decreases. The slice sensitivity profile typically broadens, and image noise may increase.

ARRT CT flashcards

32 cards. Read the term and the definition here. The deck at the top of this page is optional.

Informed consent for contrast
Obtained before iodinated IV contrast to document allergy history, renal function, prior reactions, and the risk/benefit discussion, allowing the patient to accept or refuse the injection.
Metformin and iodinated contrast
Hold metformin for 48 hours after contrast only when acute kidney injury or eGFR below 30 mL/min/1.73 m² is present; restart after renal function is rechecked.
Extravasation first response
Stop the injection immediately, remove the cannula, elevate the limb, apply a cold compress, and document the volume, site, and patient symptoms with follow-up instructions.
Anaphylactoid reaction treatment
Bronchospasm, laryngeal edema, or hypotension after contrast requires IM epinephrine 1:1000 at 0.3–0.5 mg in adults, plus oxygen, IV fluids, and emergency support.
Breath-hold coaching
Instruct the patient to take a full inspiration and hold still; having the patient hyperventilate beforehand lengthens the achievable breath-hold and reduces motion artifact.
Pediatric CT dose principle
Use the lowest kVp and mAs that produce a diagnostic image, weight-based contrast volumes near 1–2 mL/kg, and immobilization instead of sedation when possible.
eGFR threshold for contrast
An eGFR of 30 mL/min/1.73 m² or higher is generally acceptable for iodinated contrast; lower values require radiologist risk/benefit review and hydration planning.
Expected contrast sensations
A warm flush, metallic taste, and transient nausea are normal during injection; the patient should report pain, burning, or swelling at the IV site immediately.
Pregnancy and CT
CT is performed when clinically indicated regardless of pregnancy; justification is documented, shielding is used when feasible, and no single dose threshold defines fetal injury.
IV cannula size for CTA
Use a 20-gauge or larger cannula in an antecubital vein for flow rates of 4–5 mL/s; smaller or distal veins limit flow and degrade arterial opacification.
Saline flush purpose
A saline chaser after contrast pushes the column out of the tubing, reduces streak artifact from dense contrast in the right heart, and lowers total contrast volume needed.
Portal venous phase timing
Approximately 60–70 seconds after the start of IV contrast injection at 3–5 mL/s; hepatic and portal veins are opacified and liver parenchyma is enhanced.
Late arterial phase
About 35–40 seconds after injection, opacifying the hepatic artery and hypervascular tumors while portal vein enhancement remains incomplete.
Bolus tracking technique
Place a region of interest in a target vessel, set a trigger threshold near 100–150 HU, and start the scan after the threshold plus a short post-trigger delay.
Excretory phase CT urography
Imaging roughly 7–10 minutes after injection opacifies the renal collecting systems and ureters for evaluation of urothelial lesions or obstruction.
Prospective cardiac gating
Step-and-shoot acquisition triggered at 70–80% of the R-R interval lowers dose compared with retrospective helical scanning but requires a low, regular heart rate.
CT colonography prerequisites
Requires bowel cleansing, gas insufflation with CO2 to patient tolerance, and imaging in both supine and prone positions to redistribute stool and fluid.
Lung window settings
Window width about 1500 HU and window level about −600 HU display lung parenchyma; soft tissue windows would obscure fine interstitial detail.
Brain window settings
Window width about 80 HU and level about 40 HU; the narrow width maximizes gray-white differentiation in noncontrast head CT.
Scan range reduction
Restricting the scanned z-axis to the anatomy of interest is one of the most effective dose-reduction steps and does not degrade diagnostic image quality.
Test bolus versus tracking
A small test bolus measures time to peak enhancement before the main scan, while bolus tracking monitors enhancement in real time and triggers the scan automatically.
Hounsfield unit formula
HU = (μ_tissue − μ_water) ÷ μ_water × 1000, giving water a value of 0, air about −1000, and dense cortical bone 1000 or higher.
Pitch definition
Table travel per gantry rotation divided by the total detector beam width; pitch greater than 1 reduces dose but increases noise and slice broadening.
CTDIvol and DLP
CTDIvol equals CTDIw divided by pitch; DLP equals CTDIvol multiplied by scan length in centimeters, and effective dose is DLP times a body-region k factor.
Noise versus mAs
Image noise is inversely proportional to the square root of mAs, so quadrupling mAs halves noise while doubling mAs reduces it by about 30–40%.
kVp and iodine contrast
Lowering kVp moves the beam closer to iodine's 33 keV k-edge, increasing iodine attenuation and contrast while raising noise and requiring higher mAs.
Bowtie filter function
Shaping the beam so fewer photons pass through the thin patient periphery reduces surface dose and improves dose efficiency across the field of view.
In-plane spatial resolution
Best achieved with a small focal spot, thin slices, sharp high-frequency kernels, and small reconstructed pixel size; it is ultimately limited by detector aperture.
Beam hardening artifact
Appears as cupping or dark streaks between dense structures; it is reduced by beam-hardening correction software, higher kVp, and thinner collimation.
Detector configuration and pitch
A configuration such as 64 × 0.625 mm sets the minimum slice thickness and the total beam width that enters the pitch calculation.
Photon starvation artifact
Occurs when very few photons reach the detectors through thick body parts, producing horizontal streaks; tube current modulation and thicker slices reduce it.
Ring artifact cause
Caused by a miscalibrated or failed detector element that produces a circular ring centered on the rotation axis in every reconstructed slice.

ARRT CT study guide

Patient Care and Education

Core concepts

CT patient care questions test whether you can prepare a patient safely and communicate clearly before, during, and after the scan. Know how to obtain a focused history: allergies, prior contrast reactions, renal disease, diabetes and metformin use, pregnancy status, asthma, heart failure, and current medications. Understand contrast screening and informed consent, IV access and gauge selection, extravasation recognition and management, and premedication principles. Also review vital-sign assessment, NPO status, sedation precautions, pediatric immobilization, and radiation-risk explanations in plain language.

Traps

Questions often confuse creatinine with eGFR, or ask you to decide definitively whether contrast is safe. The technologist screens and reports; the radiologist or protocol determines whether iodinated contrast is given. Do not assume breastfeeding must be permanently stopped after contrast-current guidance generally supports continuing without interruption, though some patients may pump and discard for a short period per local policy. Know that premedication reduces, but does not eliminate, reaction risk and follows a timed regimen, not a single dose at scan time. Oral contrast does not require the same allergy premedication as IV contrast, but aspiration risk still matters.

Worked example / rule of thumb

A common premedication regimen is prednisone 50 mg orally at 13, 7, and 1 hour before contrast, plus diphenhydramine 50 mg orally 1 hour before, with local protocol and emergency coverage. If a patient reports hives and wheezing after a prior iodinated contrast injection, treat that as a significant reaction: stop, assess airway and vital signs, call for help, and document. Rule of thumb: screen, verify, and escalate-never independently override a contrast contraindication.

Communication and education

Use short, concrete explanations: what will happen, how long it takes, when contrast may cause flushing or warmth, and how to signal the technologist. Validate understanding and address claustrophobia or anxiety before positioning.

Imaging Procedures

Core concepts

Procedure questions emphasize protocol selection, patient positioning, contrast timing, and image review. Know common CT protocols: noncontrast head, CTA head and neck, chest without and with contrast, CT pulmonary angiography, abdomen/pelvis in arterial, portal venous, and delayed phases, and spine or musculoskeletal protocols. Understand scan direction, breath-hold instructions, field of view, reconstruction thickness, multiplanar reformats, and when oral or rectal contrast is used. Familiarity with bolus tracking and test-bolus timing is essential for vascular studies.

Traps

Many questions hinge on phase timing. Portal venous abdomen is typically about 70–80 seconds after IV contrast; arterial is about 35–40 seconds; delayed phases are often 5–10 minutes. CT pulmonary angiography is timed to the pulmonary trunk, not the aorta. A noncontrast head is generally acquired before a contrast-enhanced head when both are requested. Do not confuse oral contrast with IV contrast timing. Also watch for pitfalls in breath-hold coaching: scanning the chest during inspiration but the abdomen often during expiration or quiet breathing per protocol.

Worked example / rule of thumb

For a CTA chest to evaluate pulmonary embolism, place the region of interest in the pulmonary trunk and use bolus tracking with a threshold around 100 HU, then trigger the scan. If bolus tracking fails, a test bolus or fixed delay per protocol may be used. Rule of thumb for routine abdomen/pelvis: portal venous phase at roughly 70–80 seconds gives good hepatic and venous enhancement, while arterial phase highlights hypervascular lesions and arteries.

Image review

Check coverage, motion, contrast opacification, and artifacts before the patient leaves. Repeat only when clinically necessary and justified.

Physics and Instrumentation

Core concepts

CT physics questions test the x-ray tube, filtration, collimation, detector arrays, data acquisition, image reconstruction, and dose metrics. Understand how kVp and mAs affect penetration, noise, contrast, and dose; how pitch relates table speed to beam width; and how voxel size, reconstruction kernel, and slice thickness influence spatial and contrast resolution. Know Hounsfield units, window width and level, helical versus axial scanning, multidetector geometry, and the purpose of iterative reconstruction. Also review CTDIvol, dose-length product, and the relationship between pitch and radiation dose.

Traps

Higher kVp generally increases penetration and reduces noise but lowers soft-tissue contrast and raises dose. Increasing mAs raises dose and reduces noise, with noise changing approximately as the inverse square root of mAs. Pitch greater than 1 reduces dose but can increase noise and artifact; pitch less than 1 increases dose. Window width controls displayed contrast; window level controls brightness. Do not confuse spatial resolution with contrast resolution, or CTDIvol with patient dose. Isocenter positioning matters because off-center patients can receive higher surface dose and suffer out-of-field artifacts.

Worked example / rule of thumb

Pitch = table feed per gantry rotation divided by total beam collimation. If the table moves 30 mm per rotation and the collimation is 40 mm, pitch = 30/40 = 0.75. Because pitch is below 1, slices overlap and dose increases relative to pitch 1. For Hounsfield units, HU = [(μ tissue − μ water) / μ water] × 1000; water is 0 HU and air is approximately −1000 HU.

Dose and quality

Optimize rather than simply minimize: use appropriate kVp, automatic exposure control, and iterative reconstruction while preserving diagnostic quality.

ARRT CT cheat sheet

Quick reference

Patient Care and Education

  • Informed consent for iodinated IV contrast documents allergy history, renal function (eGFR), prior contrast reactions, and the risk/benefit discussion before injection.

  • An eGFR of 30 mL/min/1.73 m² or higher is generally acceptable for iodinated contrast; values below 30 require radiologist risk/benefit review.

  • Metformin is withheld for 48 hours after iodinated contrast only when acute kidney injury or eGFR below 30 mL/min/1.73 m² is present, then resumed after renal function is rechecked.

  • Mild reactions (nausea, limited urticaria) are managed with observation and symptomatic treatment; anaphylactoid reactions (bronchospasm, laryngeal edema, hypotension) require IM epinephrine 1:1000, 0.3–0.5 mg in adults, oxygen, and IV fluids.

  • Extravasation response: stop the injection, remove the cannula, elevate the limb, apply a cold compress, document volume and site, and give follow-up instructions.

  • Breath-hold coaching: full inspiration for chest and abdomen; hyperventilating the patient before the hold lengthens achievable breath-hold time and reduces motion artifact.

  • Pregnancy is not an absolute contraindication to CT; the ACR position is that the study is performed when clinically indicated, with documented justification and shielding when feasible.

  • Warm flush, metallic taste, and transient nausea are expected during injection; the patient must report pain, burning, or swelling at the IV site immediately.

  • Pediatric care: lowest kVp and mAs consistent with diagnosis, weight-based contrast near 1–2 mL/kg, and immobilization preferred over sedation.

Quick reference

Imaging Procedures

  • Portal venous phase abdomen: approximately 60–70 seconds after start of injection at 3–5 mL/s; late arterial phase is approximately 35–40 seconds.

  • Bolus tracking: place the ROI in the target vessel, set a trigger near 100–150 HU, and begin the scan after the threshold plus a short post-trigger delay.

  • CT pulmonary angiogram: ROI in the pulmonary trunk with a threshold near 100 HU and a short post-threshold delay, or a timing test bolus.

  • CT urography excretory phase is acquired roughly 7–10 minutes after injection to opacify collecting systems and ureters.

  • Cardiac CT: target heart rate 60 bpm or below; prospective ECG-triggered step-and-shoot at 70–80% of the R-R interval lowers dose versus retrospective helical acquisition.

  • CT colonography requires bowel cleansing, CO2 insufflation to patient tolerance, and imaging supine and prone so stool and fluid redistribute.

  • Standard window settings: soft tissue W 350–400 / L 40–50; lung W ~1500 / L ~−600; bone W ~2000 / L 300–500; brain W ~80 / L ~40.

  • Restricting the scanned z-axis to the anatomy of interest and using automatic tube current modulation are the most reliable dose-reduction steps in routine protocols.

Quick reference

Physics and Instrumentation

  • HU = (μ_tissue − μ_water) ÷ μ_water × 1000; water is 0, air about −1000, and dense cortical bone 1000 or greater.

  • Helical pitch = table travel per gantry rotation ÷ total detector beam width; pitch above 1 lowers dose and raises noise, pitch below 1 raises dose.

  • CTDIvol = CTDIw ÷ pitch for helical scans; DLP = CTDIvol × scan length in cm; effective dose ≈ DLP × body-region k factor (mSv/mGy·cm).

  • Noise is inversely proportional to the square root of mAs: quadrupling mAs halves noise, and doubling mAs reduces it by roughly 30–40%.

  • Lowering kVp moves the beam nearer iodine's 33 keV k-edge, increasing iodine attenuation and contrast while raising noise, so mAs must rise to compensate.

  • The bowtie filter shapes the beam so fewer photons traverse the thin patient periphery, reducing surface dose and improving dose efficiency.

  • Spatial resolution improves with a small focal spot, thin slices, sharp high-frequency kernels, and small reconstructed pixel size; it is limited by detector aperture.

  • Beam hardening produces cupping and dark streaks between dense structures and is reduced by correction software, higher kVp, and thinner collimation.

  • Detector configuration (e.g., 64 × 0.625 mm) sets the minimum slice thickness and the total beam width used in the pitch calculation.

ARRT CT key terms

Informed consent

The process of explaining a procedure's purpose, risks, benefits, and alternatives to a patient, confirming understanding, and obtaining voluntary permission before the examination begins. It is documented before contrast is given or an invasive step is performed.

Related: IV contrast extravasation, Post-contrast acute kidney injury
IV contrast extravasation

Leakage of iodinated contrast out of a vein into surrounding soft tissue during a power injection. It causes pain and swelling and requires stopping the injection, removing the cannula, and documenting and monitoring the site.

Related: Power injector IV access requirements
Post-contrast acute kidney injury

A rise in serum creatinine occurring within a few days after iodinated contrast administration, reflecting a temporary decline in kidney function. Risk is higher in patients with existing renal impairment, diabetes, or dehydration.

Related: Estimated glomerular filtration rate (eGFR), Informed consent
Estimated glomerular filtration rate (eGFR)

A calculated estimate of how well the kidneys filter blood, derived from serum creatinine plus age and sex. It is used to screen patients before iodinated contrast and to guide hydration or alternative-imaging decisions.

Related: Post-contrast acute kidney injury
Contrast premedication

A corticosteroid regimen, sometimes combined with an antihistamine, given hours before contrast to reduce the severity of allergic-type reactions in patients with a prior reaction. It lowers but does not eliminate risk.

Related: Anaphylactoid reaction
Anaphylactoid reaction

A sudden immune-like reaction to contrast that can include hives, bronchospasm, hypotension, and airway swelling. It is managed promptly with epinephrine, oxygen, intravenous fluids, and antihistamines following department protocol.

Related: Contrast premedication
ALARA principle

As Low As Reasonably Achievable: the practice of keeping radiation dose to patients and staff as low as practical while still producing diagnostic images, using technique selection, shielding, and protocol optimization.

Related: Automatic tube current modulation, CTDIvol
CT pregnancy screening

A required inquiry about pregnancy or the possibility of pregnancy before scanning the abdomen or pelvis. If pregnancy is possible, the radiologist is consulted to confirm the examination is justified or to adjust the protocol.

Related: ALARA principle
Power injector IV access requirements

Rules for selecting a vein and cannula able to withstand rapid contrast injection, typically a large forearm vein with an adequately sized catheter, checked for patency and blood return before connection.

Related: IV contrast extravasation
Pediatric immobilization

Methods such as swaddling, positioning aids, or parental presence used to keep a child still during CT, reducing motion artifact and the need for repeat scanning or sedation.

Related: ALARA principle
Bolus tracking

A technique in which repeated low-dose images monitor contrast arrival in a target vessel; the scan starts automatically once a preset enhancement threshold is reached, timing the acquisition to peak contrast.

Related: Test bolus, CT angiography
Test bolus

A small contrast injection followed by rapid low-dose imaging at a fixed level to measure how long contrast takes to reach the vessel of interest, so the main scan can be timed accordingly.

Related: Bolus tracking
Multiphasic CT

An examination that images the same anatomy at several time points after contrast injection, such as unenhanced, arterial, portal venous, and delayed phases, to characterize vessels and lesions.

Related: Bolus tracking, CT urography
CT angiography

A contrast-enhanced study timed to opacify arteries, using thin slices and fast helical acquisition, then post-processed with reformats or projections to display vessels clearly.

Related: Bolus tracking, Maximum intensity projection (MIP)
CT urography

A multiphase study of the urinary tract combining unenhanced, nephrographic, and excretory phases, often with thin-slice reformats, to evaluate stones, masses, and collecting-system anatomy.

Related: Multiphasic CT
High-resolution CT (HRCT) of the chest

A lung protocol using thin collimation, a high-spatial-frequency reconstruction kernel, and often reduced dose to show fine parenchymal detail such as interlobular septa and honeycombing.

Related: Multiplanar reformation (MPR)
Multiplanar reformation (MPR)

Two-dimensional images reconstructed from a volumetric dataset in planes other than the original acquisition plane, such as coronal, sagittal, or oblique, without additional patient dose.

Related: Isotropic voxel, Maximum intensity projection (MIP)
Maximum intensity projection (MIP)

A post-processing method that displays only the brightest voxel along each viewing ray, making contrast-filled vessels and bone stand out across a slab or volume.

Related: CT angiography, Volume rendering
Volume rendering

A three-dimensional display technique that assigns color and opacity to voxel values, producing a rotatable image that shows surface and internal anatomy together.

Related: Maximum intensity projection (MIP)
CT-guided biopsy

Using CT images to plan and confirm needle placement for tissue sampling, often with limited or intermittent CT fluoroscopic exposure to keep staff and patient dose low.

Related: Multiplanar reformation (MPR)
CT colonography

A low-dose study of the cleansed, gas-distended colon, with images reviewed in two and three dimensions to detect polyps and masses; preparation and insufflation quality strongly affect accuracy.

Related: Multiplanar reformation (MPR)
ECG-gated cardiac CT

Cardiac imaging in which the ECG signal is used to acquire or reconstruct data during a consistent phase of the cardiac cycle, reducing motion blur caused by heartbeats.

Related: Coronary calcium scoring, Pitch
Coronary calcium scoring

A non-contrast, low-dose CT of the heart that quantifies calcified plaque in the coronary arteries; the score is calculated from calcification area and density to estimate cardiovascular risk.

Related: ECG-gated cardiac CT, Hounsfield unit
Isotropic voxel

A voxel with equal dimensions along all three axes, so reformats in any plane keep the same spatial resolution; thin-slice helical acquisition is used to create them.

Related: Multiplanar reformation (MPR)
Hounsfield unit

A scaled CT number expressing tissue attenuation relative to water, where water is 0 and air is about -1000. It lets observers compare tissue density across scanners and examinations.

Related: Linear attenuation coefficient, Beam hardening artifact
Linear attenuation coefficient

A measure of how much a beam's intensity is reduced per unit thickness of material. In CT it depends on photon energy and tissue composition and underlies the reconstructed CT number.

Related: Hounsfield unit, Photoelectric effect, Compton scattering
Photoelectric effect

A photon is completely absorbed by an inner-shell electron, which is ejected. It dominates at lower energies and in higher-atomic-number materials such as bone and iodine, producing strong contrast.

Related: Compton scattering, Linear attenuation coefficient
Compton scattering

A photon interacts with an outer-shell electron, transfers part of its energy, and is deflected. It dominates at higher energies and in soft tissue, adding scatter and noise rather than contrast.

Related: Photoelectric effect
Pitch

For helical scanning, table travel per gantry rotation divided by the total collimated beam width. Higher pitch shortens scan time and dose but can raise noise and artifacts if set too high.

Related: Overranging, Automatic tube current modulation
Automatic tube current modulation

The scanner adjusts tube current along the scan or around the patient based on measured attenuation, maintaining image quality while lowering dose in thinner or less dense regions.

Related: ALARA principle, Pitch
Iterative reconstruction

An image reconstruction approach that repeatedly compares calculated projections with measured data to reduce noise, allowing lower dose while preserving diagnostic image quality.

Related: Automatic tube current modulation
CTDIvol

Volume computed tomography dose index: the average absorbed dose to a standard phantom from one rotation divided by pitch, reported in milligray and used to compare protocol dose.

Related: Dose-length product, Size-specific dose estimate
Dose-length product

The product of CTDIvol and scan length in centimeters, expressed in mGy·cm; it estimates the total radiation output for a scan series and is used to derive effective dose.

Related: CTDIvol, Size-specific dose estimate
Size-specific dose estimate

A CTDIvol-based value corrected for patient or body-part thickness, giving a closer approximation of dose for an individual than the fixed phantom index alone.

Related: CTDIvol, Dose-length product
Beam hardening artifact

Dark streaks or bands caused when lower-energy photons are absorbed preferentially as the beam passes through dense material, so the beam hardens and reconstruction assumes nonuniform attenuation.

Related: Hounsfield unit, Photoelectric effect
Partial volume averaging

A voxel containing a mixture of tissues receives a CT number reflecting the average, so small objects or edges may appear falsely low or high in density.

Related: Hounsfield unit, Isotropic voxel
Bowtie filter

A shaped pre-patient filter that is thin at the center and thick at the edges, reducing dose to peripheral tissue and shaping the beam to the patient's cross-section.

Related: Automatic tube current modulation
Overranging

Extra rotations at the start and end of a helical scan needed to reconstruct the first and last images, adding dose beyond the imaged volume; it grows with wider collimation and higher pitch.

Related: Pitch

ARRT CT study plan

8 weeks · About 7 hours per week

Week 1

Patient Care and Education

  • Map the patient care and education domain into a checklist of communication, screening, consent, and education tasks.

  • Practice explaining CT preparations and common instructions in plain language for five patient scenarios.

  • Identify contrast, medication, allergy, and renal-function precautions and state the technologist's action for each.

  • Demonstrate safe transfer, positioning, and immobilization decisions for patients with varied mobility needs.

Your checkpoint

Score at least 80% on a 25-question patient care self-quiz and correct every missed item in writing.

Week 2

Patient Care and Education & Imaging Procedures

  • Apply infection control and patient identification steps to simulated CT workflows.

  • Outline response steps for mild, moderate, and severe contrast reactions.

  • Match ten common CT examinations to patient preparation, contrast use, and education points.

  • Explain how to adapt communication for pediatric, geriatric, and anxious patients.

Your checkpoint

Create a one-page patient preparation and communication quick-reference covering ten CT exams, checked against at least 90% accuracy on a peer or self-review.

Week 3

Imaging Procedures

  • List scanning protocols for neuro, chest, abdomen, pelvis, and musculoskeletal CT examinations.

  • Adjust protocol choices for trauma, pediatric, and renal-compromise scenarios.

  • Sequence contrast phases and timing for CTA and multiphase abdominal studies.

  • Select artifact-reduction strategies for motion, metal, and beam-hardening cases.

Your checkpoint

Build a protocol table for 15 CT examinations with contrast, phase, oral preparation, and patient-positioning notes.

Week 4

Imaging Procedures & Physics and Instrumentation

  • Connect procedure choices to attenuation, Hounsfield units, window width, and window level.

  • Compare axial, helical, and volumetric acquisition modes for common clinical indications.

  • Calculate and interpret basic dose descriptors such as CTDIvol and DLP in practice scenarios.

  • Review missed procedure questions and state the reasoning for each corrected answer.

Your checkpoint

Score at least 80% on a 40-question mixed procedures-and-physics quiz and log corrections for every missed item.

Week 5

Physics and Instrumentation

  • Describe x-ray tube, detector, and data-acquisition system components and their functions.

  • Explain filtered back projection and iterative reconstruction in terms of image quality and workflow.

  • Apply pitch, collimation, and reconstruction interval relationships to scanning examples.

  • Solve calculation problems involving dose, pitch, and scan time.

Your checkpoint

Complete a formula sheet plus 20 calculation problems with at least 85% accuracy.

Week 6

Patient Care and Education & Physics and Instrumentation

  • Explain radiation dose and risk to patients using accurate, calm, plain-language statements.

  • Match quality-control tests to the equipment problem each test detects.

  • Diagnose common CT artifacts by cause, appearance, and corrective action.

  • Integrate dose-optimization choices with patient education and comfort needs.

Your checkpoint

Produce a 12-entry artifact and QC troubleshooting matrix with cause, recognition clue, and corrective action for each entry.

Week 7

Imaging Procedures & Physics and Instrumentation

  • Re-scan weak procedure and physics objectives identified by prior quiz results.

  • Compare protocols across at least three body regions using image-quality and dose tradeoffs.

  • Practice timing, reconstruction, and parameter decisions in timed case scenarios.

  • Explain each selected protocol parameter aloud without notes.

Your checkpoint

Complete a timed 30-question weak-area set and raise the score by at least 10 percentage points over the Week 4 quiz.

Week 8

Patient Care and Education & Imaging Procedures

  • Take a full-length mixed mock exam under timed conditions.

  • Review every missed item and classify it by domain and error type.

  • Rehearse patient education and safety responses that integrate procedure and dose knowledge.

  • Build a final one-page summary of high-risk facts, formulas, and protocol reminders.

Your checkpoint

Score at least 85% on a full-length mock exam and submit a correction log covering all missed questions.

Milestones

Week 4: Mixed procedures-and-physics quiz score is at least 80%, with corrections completed for all missed items.

Week 6: Artifact/QC matrix and patient-communication quick-reference are complete and self-reviewed for accuracy.

Week 8: Full-length mock exam score is at least 85%, and every missed question is classified and corrected.

ARRT CT exam day

Your checklist

Appointment confirmation

Print or save the scheduling confirmation from the test vendor showing your name, exam title (ARRT Computed Tomography), date, time, and test-center address.

Primary photo ID

A valid, unexpired government-issued photo ID with your signature (driver's license, state ID, passport, or military ID). The name must match your name exactly as it appears on your ARRT record and appointment - confirm the exact ID requirements and whether a second form of ID is required in the ARRT Candidate Handbook and with the test vendor.

Secondary ID

Some testing programs require a second signature-bearing form of ID (such as a signed credit card or signed Social Security card). needs_review - verify with the test vendor which secondary IDs are accepted before test day.

Names consistent on all documents

If your ID shows a different name (maiden vs. married, middle initial, hyphenation) than your ARRT record, contact ARRT and the test vendor in advance to correct it - mismatches can prevent admission.

Arrival plan

Know the route, parking, and building/floor of the test center. Plan to arrive well before your appointment time (many centers ask for about 30 minutes early for check-in) - confirm the recommended arrival time on your confirmation.

Leave prohibited items behind

Do not bring study notes, textbooks, phones, smartwatches, fitness trackers, earbuds, or any recording device into the testing room. Plan where your personal items will go - most centers provide a small locker, but confirm.

Layered clothing

Dress comfortably in layers; testing rooms are often cool. Avoid loose sleeves, bulky pockets, hats, and jewelry that may prompt extra security checks or need to be removed.

Approved accommodations

If you need extra time or other accommodations, it must have been requested from ARRT in advance with documentation. Accommodations are not granted on test day - confirm your approval status is on file.

Light-review materials only

Bring a one- or two-page summary of heavily weighted content (patient care and safety, image production, procedures, and physics/instrumentation) for a quick glance before check-in - expect to hand off or store all materials before entering the room.

Water and a light snack

Eat a normal breakfast; carry water and a snack for before or after the exam. Most centers do not allow food or drink in the testing room - confirm the center's policy on accessibility during any break.

Eligibility window check

Confirm your exam eligibility window and that your appointment falls inside it; missed windows may require re-application. needs_review - verify current window rules with ARRT.

Rest and logistics

Protect your sleep for the two nights before the exam rather than adding late-night cramming; fatigue costs more points than a final hour of review gains.

Plan the day

72 hours before - confirm logistics

Re-read your appointment confirmation and the ARRT Candidate Handbook sections on ID, prohibited items, arrival time, and scoring. Confirm the test-center address and drive time, and decide your parking and backup route. Recheck that your ID is unexpired and names match.

72 hours before - triage content

Stop trying to relearn everything. Identify your three weakest content areas from practice tests and spend focused review time only on those, using your own notes and a published content specification outline.

72 hours before - practice under timing

Take one timed practice set of roughly exam length so you know your per-question pace and can decide in advance how you will handle long calculation or image-based items.

72 hours before - reset your clock

Shift your sleep schedule so you will be alert at your appointment time. If you have an early slot, practice waking at that hour.

24 hours before - light review only

Spend at most a couple of hours skimming your own summary sheet: scan parameters, radiation dose and protection terms, contrast reactions, and common procedures. Then stop, and do not start a new topic you have never studied.

24 hours before - pack tonight

Place your IDs, appointment confirmation, and directions in one place near the door. Set two alarms. Lay out your clothing.

24 hours before - protect the night

Eat a normal dinner, avoid alcohol and heavy caffeine late in the day, and go to bed at your usual time. Confirm the weather forecast and adjust your departure time if needed.

Morning of - routine, not cramming

Eat breakfast, hydrate moderately, take your IDs and confirmation, and leave with a buffer. Do not study in the car - arriving anxious and overloaded hurts more than it helps.

At the center - check-in

Arrive early, present your ID(s), complete any signature or biometric check-in, store personal items as directed, and use the restroom before you are seated. Follow staff instructions exactly.

During the test - pacing

Read each question completely and watch for qualifiers such as 'best,' 'first,' and 'except.' Answer every item - there is normally no penalty for guessing, so never leave a blank. If the delivery system offers a mark-for-review and review screen, use it once at the end rather than second-guessing every item as you go.

During the test - strategy

For calculations, estimate first so you can recognize an implausible answer. For protocol or patient-care questions, eliminate options that would increase dose unnecessarily or compromise patient safety, then choose the best remaining answer.

After the test

Follow center procedures for completing the exam and receiving your score report; keep any printed confirmation. Confirm with the test vendor and ARRT how and when official results are released and what the retake policy is before you leave the site.

Rules to check

  • Bring valid, unexpired identification with a signature and photo, with the name matching your appointment and ARRT record exactly; you may be refused admission otherwise. Confirm the accepted ID types and whether two forms are required with the test vendor before test day.

  • Do not bring phones, smartwatches, wearable devices, notes, books, or any recording device into the testing room. Unauthorized items in the testing area can result in your exam being voided; use the provided storage and confirm the center's rules at check-in.

  • You will likely be asked to accept a confidentiality agreement covering exam content; reproducing, discussing, or sharing specific exam questions is prohibited and may carry consequences from ARRT.

  • Follow all test-center staff directions, including any clothing, pocket-emptying, or security-screening procedures. Challenges to proctor instructions are handled after the exam, not during it.

  • If you need to leave the room, raise your hand and wait for staff; in most testing programs the clock continues to run during unscheduled breaks. Confirm the break policy for your appointment with the provider.

  • Scoring is reported as pass/fail with a scaled score; ARRT's scale runs from 1 to 99 with 75 as the minimum passing scaled score - verify the current passing standard in the ARRT Candidate Handbook, as standards can change.

  • Accommodations and any rescheduling must be arranged with ARRT and the test vendor in advance; they are not granted at the test center on the day of the exam.

  • If you do not pass, a waiting period applies before you may retest, and additional requirements may apply. Confirm the current retake policy with ARRT before scheduling again.

ARRT CT FAQ

How many ARRT CT practice questions are available?

The practice set has 200 ARRT CT questions. Each one includes the choices, the correct answer, and an explanation, and the set is free to read with no signup.

How many ARRT CT flashcards are available?

The flashcard set has 32 ARRT CT cards. Each card shows the term and its definition.

Which topics does the ARRT CT study material cover?

The ARRT CT study material covers Patient Care and Education, Imaging Procedures, and Physics and Instrumentation.

What format facts does the catalog list for the ARRT CT exam?

The catalog lists these item types: multiple choice for the ARRT CT exam.