NHA EKG Technician Practice Test

Certified EKG Technician (CET)

NHA EKG Technician overview

  • 200 practice questions
  • 32 flashcards
  • 4 study guide topics
  • 39 key terms

What you'll study

  • Patient Preparation, Safety, and Infection Control25%
  • Cardiovascular Anatomy, Physiology, and Electrophysiology25%
  • EKG Equipment, Lead Placement, and Tracing Acquisition25%
  • Rhythm Recognition, Interpretation, and Reporting25%

The Certified EKG Technician (CET) credential is one of the certifications offered by the National Healthcareer Association (NHA), an allied health certification body that states it has served allied health since 1989 and has awarded over 1 million nationally recognized certifications. NHA lists the EKG Technician role as one that administers a variety of cardiovascular tests, and describes its certifications as NCCA-accredited and recognized by employers nationwide. The credential is intended for people preparing to perform electrocardiograms and related cardiovascular testing in clinics, hospitals, physician offices, and other care settings, whether entering the field or adding a skill to an existing clinical role. This independent study page is not affiliated with or endorsed by NHA; it exists to help you organize preparation. Our practice questions are grouped into four study areas: patient preparation, safety, and infection control; cardiovascular anatomy, physiology, and electrophysiology; EKG equipment, lead placement, and tracing acquisition; and rhythm recognition, interpretation, and reporting. Because NHA does not publish exam length, timing, fee, or passing score on the pages we retrieved, confirm every logistical detail in NHA's Candidate Handbook before you schedule, and use this page for content review and self-testing rather than for official exam rules.

Common mistakes

Starts the 12-lead without confirming the patient's name and date of birth against two identifiers and without asking about adhesive or latex allergies.

Candidates memorize lead order and rush to place electrodes, treating patient identification as a formality.

What to do instead

Verify two identifiers, ask about allergies and skin conditions, and document before exposing the chest.

Applies electrodes directly over lotion, sweat, or chest hair without cleansing, drying, or clipping.

Time pressure and the belief that electrode gel will cut through interference.

What to do instead

Rub the skin with gauze or an alcohol pad, dry it, clip hair if needed, and reapply electrodes if baseline wander appears.

Moves from patient to patient without hand hygiene or disinfecting reusable cables and lead wires.

Focus is on the machine and tracing; equipment is not recognized as a fomite.

What to do instead

Perform hand hygiene before and after contact and disinfect cables per manufacturer instructions between patients.

Places limb or precordial leads by memorized color sequence alone, resulting in swapped RA/LA or V1/V2 in the wrong intercostal space.

Color codes vary and candidates do not landmark from anatomy.

What to do instead

Landmark from the sternal notch, count intercostal spaces, and confirm RA/LA placement before recording.

Records a tracing without checking that the machine is set to 25 mm/s and 10 mm/mV and that the calibration pulse is present.

Assumes default settings are intact, but a previous user may have changed them.

What to do instead

Verify paper speed, gain, and calibration pulse at the start of every recording and note any changes in documentation.

Labels somatic tremor, baseline wander, or 60-cycle interference as atrial fibrillation or another dysrhythmia.

Pattern recognition is applied without first assessing tracing quality.

What to do instead

Inspect for artifact first: check electrode adhesion, patient shivering, and nearby electrical equipment; correct the cause and re-record before interpreting.

Uses the 1500 small-box method to calculate heart rate on an irregular rhythm.

Only one formula is memorized and irregularity is ignored.

What to do instead

Use the 6-second strip count times 10 for irregular rhythms; use R-R averaging only when the rhythm is regular.

Fails to recognize pacemaker spikes or mislabels a paced beat as a native bundle branch block.

Spikes are small and candidates do not scan for them before analyzing QRS morphology.

What to do instead

Scan the full tracing for vertical spikes before each P wave or QRS and correlate each spike with capture.

Sees a wide-complex tachycardia, ST elevation, or another critical finding on the tracing and files it without immediately notifying the provider.

Uncertainty about scope of practice or fear of being wrong delays escalation.

What to do instead

Follow the critical-value policy: report immediately, document the time and recipient, and stay with an unstable patient.

Cannot map ECG waveform components to the conduction pathway, such as calling the PR segment the P wave or confusing the QT interval with the QRS.

Memorizes waveform shapes without linking them to SA node, AV node, and His-Purkinje activation.

What to do instead

Draw the conduction pathway and label each ECG component by its electrical event; practice on a normal tracing until the sequence is automatic.

Exam requirements can change. Confirm current details with the exam provider.

NHA EKG Technician practice

200 questions. Each one lists the choices, the correct answer, and an explanation. With JavaScript, this list opens one question at a time. The checker at the top of this page saves progress in this browser when it is available.

  1. Question 1Patient Preparation, Safety, and Infection Control

    What is the minimum recommended duration for washing hands with soap and water?

    1. 20 seconds Correct answer.
    2. 15 seconds
    3. 5 seconds
    4. 10 seconds

    Explanation

    Guidelines recommend scrubbing all surfaces of the hands and wrists with soap and water for at least 20 seconds, then rinsing and drying thoroughly. Shorter scrubs do not give the soap enough contact time to remove transient organisms. Hand hygiene is performed before and after every patient contact.

  2. Question 2Patient Preparation, Safety, and Infection Control

    Gloves should be worn by the EKG technician in which situation?

    1. Only during invasive procedures such as injections
    2. Whenever contact with blood or fluids is likely Correct answer.
    3. Only if the patient has a diagnosed infection
    4. Only when the patient requests that you do so

    Explanation

    Standard precautions require gloves whenever the task may bring the technician into contact with blood, body fluids, secretions, or non-intact skin. The decision is based on the anticipated exposure, not on a known diagnosis. Gloves never replace hand hygiene.

  3. Question 3Patient Preparation, Safety, and Infection Control

    Which two identifiers are acceptable when verifying a patient before an EKG?

    1. The patient's insurance number and home address
    2. The patient's room number and bed position
    3. The patient's full name and date of birth Correct answer.
    4. The patient's diagnosis and physician name

    Explanation

    Two independent identifiers, typically the patient's full name and date of birth, must be used and matched to the order or armband. Room numbers and bed assignments change and are not unique identifiers. Verification occurs before any tracing is obtained.

  4. Question 4Patient Preparation, Safety, and Infection Control

    How should the skin be prepared before electrodes are attached?

    1. Rub the site vigorously with dry gauze for a full minute
    2. Apply a thin layer of lotion to improve adhesion
    3. Cleanse the site with alcohol and let it air dry Correct answer.
    4. Cleanse the site with hydrogen peroxide and blot dry

    Explanation

    Alcohol removes oils and residue, and allowing it to air dry improves electrode adhesion and reduces impedance. Rubbing the skin aggressively can cause irritation and does not clean it. Lotions and damp skin both interfere with a stable tracing.

  5. Question 5Patient Preparation, Safety, and Infection Control

    When choosing chest electrode sites, the technician should place electrodes over which type of tissue?

    1. Areas with the largest muscle mass
    2. Skin folds beneath the breast
    3. Hairy areas for better conduction
    4. Firm bony areas with little muscle Correct answer.

    Explanation

    Electrodes placed over bone are less affected by muscle movement and produce a cleaner baseline. Large muscle masses generate electrical activity and somatic tremor artifact. Hairy and folded areas also degrade electrode contact.

  6. Question 6Patient Preparation, Safety, and Infection Control

    A patient reports a known latex allergy. How should the technician prepare?

    1. Ask the patient to bring their own supplies
    2. Use latex-free gloves and latex-free electrodes Correct answer.
    3. Use vinyl gloves but keep the standard latex electrodes
    4. Double the standard gloves for extra protection

    Explanation

    All latex-containing items that may contact the patient, including electrodes and blood pressure cuffs, must be replaced with latex-free alternatives. Doubling latex gloves does not prevent an allergic reaction. The allergy should also be documented and communicated to the care team.

  7. Question 7Patient Preparation, Safety, and Infection Control

    How should the technician protect a patient's modesty during a 12-lead EKG?

    1. Leave the door open so the patient does not feel confined
    2. Expose only the chest and cover the rest with a drape Correct answer.
    3. Complete the tracing quickly without using any covering
    4. Ask the patient to remove all clothing from the waist up

    Explanation

    Only the area being examined should be exposed, and the remainder of the body is kept covered with a drape or gown. Doors and curtains are closed to provide visual privacy. Explaining each step also helps the patient feel secure.

  8. Question 8Patient Preparation, Safety, and Infection Control

    Which action best reduces a patient's anxiety before an EKG?

    1. Describing the procedure only if the patient asks
    2. Waiting until the tracing is finished to answer questions
    3. Telling the patient that no explanation is necessary
    4. Explaining each step before it is performed Correct answer.

    Explanation

    Telling the patient what will happen, in advance and in plain language, reduces fear and improves cooperation. Questions should be invited and answered as they arise. A calm, unhurried approach also lowers heart rate and reduces artifact.

  9. Question 9Patient Preparation, Safety, and Infection Control

    During the tracing the patient keeps shifting position and the baseline becomes unreadable. What is the best first action?

    1. Increase the paper speed to override the artifact
    2. Reposition the limb leads onto the patient's ankles
    3. Continue and document the artifact in the report
    4. Ask the patient to lie still and breathe normally Correct answer.

    Explanation

    Movement artifact is corrected at its source by helping the patient relax, lie still, and breathe quietly. Changing machine settings does not remove the underlying interference. If artifact persists, electrode contact and cable placement are checked next.

  10. Question 10Patient Preparation, Safety, and Infection Control

    How should reusable electrodes be handled between patients?

    1. Disinfect them with an approved agent per policy Correct answer.
    2. Rinse them in water and let them air dry
    3. Store them in the patient's room until next use
    4. Wipe them with a dry paper towel and reuse them

    Explanation

    Reusable equipment is cleaned and then disinfected with a facility-approved product between patients. A dry wipe alone does not reduce pathogens. Manufacturer instructions determine the correct contact time and compatible agents.

  11. Question 11Patient Preparation, Safety, and Infection Control

    The technician is stuck by a contaminated needle left on the bed. What is the first action?

    1. Squeeze the wound and apply a tight bandage
    2. Clean the wound with alcohol and finish the shift first
    3. Wait to see whether symptoms develop before reporting
    4. Wash the site with soap and water and report immediately Correct answer.

    Explanation

    After a sharps injury the site is washed with soap and water, and the exposure is reported and evaluated right away so post-exposure care can begin. Time-sensitive prophylaxis may be needed. Delaying evaluation can reduce the effectiveness of treatment.

  12. Question 12Patient Preparation, Safety, and Infection Control

    A patient with a C. difficile infection is in contact precautions. How should the technician proceed?

    1. Use only gloves, since contact precautions do not require a gown
    2. Wear a respirator and move the patient to a negative-pressure room
    3. Perform the EKG in the hallway to avoid entering the room
    4. Don a gown and gloves and use dedicated equipment in the room Correct answer.

    Explanation

    Contact precautions require a gown and gloves for entry, with equipment dedicated to that patient or cleaned before it leaves the room. Alcohol-based rubs do not reliably kill C. difficile spores, so soap and water handwashing is used. The door may remain closed and the precaution sign is followed.

  13. Question 13Patient Preparation, Safety, and Infection Control

    Midway through the EKG the patient becomes pale, diaphoretic, and reports feeling faint. What should the technician do?

    1. Stop the test, lower the patient flat, and call for help Correct answer.
    2. Give the patient water and continue the procedure
    3. Finish the tracing quickly and then help the patient sit up
    4. Ask the patient to take several rapid deep breaths

    Explanation

    These signs suggest a vasovagal or hypotensive response, so the test stops and the patient is positioned safely with the head level or lowered while help is summoned. Continuing the tracing risks a fall or loss of consciousness. Vital signs and mental status are monitored until assistance arrives.

  14. Question 14Patient Preparation, Safety, and Infection Control

    Which practice supports electrical safety when using an EKG machine?

    1. Operating the machine with the case open to cool it
    2. Using extension cords when the wall outlet is far away
    3. Inspecting the power cord and plug before each use Correct answer.
    4. Routing cables across the floor for easy access

    Explanation

    Cords and plugs are checked for fraying, cracks, and damage before use, and faulty equipment is removed from service. Cables are kept clear of walkways and away from liquids. Only grounded outlets and facility-approved equipment are used.

  15. Question 15Patient Preparation, Safety, and Infection Control

    An adult patient has dense chest hair at the V1 and V2 electrode sites. What should the technician do?

    1. Apply extra gel and press the electrodes down firmly
    2. Clip the hair at the site and then apply the electrodes Correct answer.
    3. Cancel the test until the patient shaves the area
    4. Move the electrodes to the shoulders where hair is thinner

    Explanation

    Hair prevents the electrode from contacting the skin and causes artifact, so it is clipped at the site if needed. Electrode positions must not be moved, because lead placement determines what the tracing represents. Clipping rather than shaving avoids abrasion and is more comfortable.

  16. Question 16Patient Preparation, Safety, and Infection Control

    A patient who speaks limited English needs an EKG. What should the technician do?

    1. Proceed without explanation to avoid confusion
    2. Ask the patient's young child to translate the instructions
    3. Arrange a qualified medical interpreter before starting Correct answer.
    4. Speak more loudly while pointing to the equipment

    Explanation

    A qualified interpreter, in person or by phone, ensures that instructions and consent are understood accurately. Family members, especially children, should not be used as interpreters. Speaking loudly does not overcome a language barrier.

  17. Question 17Patient Preparation, Safety, and Infection Control

    Which action complies with patient privacy requirements during an EKG?

    1. Giving results to a caller who states the patient's name
    2. Posting the rhythm strip on the unit bulletin board
    3. Discussing the patient's results only with the care team Correct answer.
    4. Sharing the tracing with anyone who asks about the patient

    Explanation

    Protected health information may be shared only with those involved in the patient's care or as authorized by the patient. Identifying information should not be posted or given out over the phone without verification and authorization. Discussing findings in public areas should also be avoided.

  18. Question 18Patient Preparation, Safety, and Infection Control

    A competent adult tells the technician he does not want the ordered EKG performed. What should the technician do?

    1. Ask a family member to convince the patient
    2. Perform the test anyway because it was ordered
    3. Respect the refusal and notify the licensed provider Correct answer.
    4. Tell the patient a waiver must be signed before refusing

    Explanation

    A competent patient may refuse any procedure, and the technician should honor that decision while informing the provider and documenting the refusal. The technician does not coerce or pressure the patient. Any questions the patient has should be answered or referred.

  19. Question 19Patient Preparation, Safety, and Infection Control

    Standard precautions should be applied in which way?

    1. Only in the emergency department and intensive care
    2. To every patient regardless of diagnosis Correct answer.
    3. Only when the patient's history is unknown
    4. Only to patients with a known bloodborne infection

    Explanation

    Standard precautions treat all blood and body fluids as potentially infectious and are used with every patient in every setting. A known diagnosis is not required to trigger them. This approach protects both patients and staff when a diagnosis is unknown.

  20. Question 20Patient Preparation, Safety, and Infection Control

    An older adult with an unsteady gait needs to lie down for an EKG. What should the technician do?

    1. Provide a steadying hand and lower the table first Correct answer.
    2. Position the table at its highest height first
    3. Ask the patient to stand on a rolling stool
    4. Let the patient climb up alone to preserve independence

    Explanation

    The table is lowered before the patient gets on, and the technician offers a steadying hand or gait belt per policy, then raises the table to a comfortable working height. This reduces the risk of falling during transfer. Fall risk should be reassessed throughout the visit.

  21. Question 21Patient Preparation, Safety, and Infection Control

    A contaminated item that could puncture the skin should be discarded in which container?

    1. A rigid puncture-resistant sharps container Correct answer.
    2. A biohazard box lined with a plastic bag
    3. A sealed paper bag labeled with the room number
    4. A double-bagged plastic trash can

    Explanation

    Sharps go directly into a rigid, puncture-resistant, closable container that is not overfilled and is replaced when full. Recapping or bending sharps is avoided. Other biohazard waste is handled according to facility policy.

  22. Question 22Patient Preparation, Safety, and Infection Control

    After caring for a patient with C. difficile, which hand hygiene method is required?

    1. Rinsing the hands with water only
    2. Wearing gloves without any hand hygiene
    3. Washing with soap and water Correct answer.
    4. An alcohol-based hand rub alone

    Explanation

    Alcohol-based rubs do not reliably kill C. difficile spores, so soap and water handwashing is required after contact with affected patients. Mechanical washing helps remove the spores from the hands. Hand hygiene is still performed even when gloves were worn.

  23. Question 23Patient Preparation, Safety, and Infection Control

    How should contaminated gloves be removed?

    1. Turn the gloves inside out as they are removed Correct answer.
    2. Peel both gloves off by the fingertips simultaneously
    3. Wash the gloves with soap before taking them off
    4. Remove the gloves and skip hand hygiene if hands look clean

    Explanation

    Gloves are removed so that they turn inside out, keeping the contaminated outer surface contained, and hand hygiene follows immediately. Touching the skin with the contaminated surface spreads organisms. Gloves are never washed and reused.

  24. Question 24Patient Preparation, Safety, and Infection Control

    While attaching leads, the patient reports new crushing chest pain. What should the technician do?

    1. Give the patient an aspirin from the unit supply
    2. Reassure the patient that chest pain is common during EKG
    3. Complete the 12-lead tracing before doing anything else
    4. Stop, stay with the patient, and call for help Correct answer.

    Explanation

    New crushing chest pain may signal an acute cardiac event, so the technician stays with the patient, summons emergency help, and notifies licensed staff immediately. The technician does not administer medications or leave the patient alone. Monitoring and documentation continue until help arrives.

  25. Question 25Patient Preparation, Safety, and Infection Control

    Which skin condition at a proposed electrode site should be avoided?

    1. Skin on the lower legs above the ankles
    2. Skin over the sternum between the ribs
    3. Skin below the clavicle on either side
    4. Skin that is broken, irritated, or covered by a rash Correct answer.

    Explanation

    Electrodes should not be placed on broken, irritated, or inflamed skin because this increases discomfort and the risk of infection. Alternative sites are chosen and the condition is documented. Intact, dry skin is required for good adhesion.

  26. Question 26Patient Preparation, Safety, and Infection Control

    Before applying EKG electrodes, how should the technician confirm that the correct patient is being tested?

    1. Check the name on the door sign and proceed if it matches.
    2. Match the requisition to the armband and verify name and birth date. Correct answer.
    3. Ask the patient to confirm the room number and bed assignment.
    4. Use the name on the previous tracing in the chart.

    Explanation

    Patient identification requires at least two identifiers, such as name and date of birth, checked against the requisition and armband. Room numbers, door signs, and prior tracings are not reliable identifiers.

  27. Question 27Patient Preparation, Safety, and Infection Control

    The technician finishes an EKG and removes gloves before moving to the next patient. What should happen next?

    1. Perform hand hygiene before touching the next patient or equipment. Correct answer.
    2. Rinse the hands with water only and dry them.
    3. Apply alcohol-based rub to the gloved hands immediately before removing them.
    4. Wait until the end of the shift to wash the hands.

    Explanation

    Hand hygiene is required after glove removal and before contact with the next patient or clean equipment. Gloves do not replace hand hygiene.

  28. Question 28Patient Preparation, Safety, and Infection Control

    After identifying the patient, what is the best way for the technician to begin the EKG?

    1. Explain the steps and invite the patient's questions. Correct answer.
    2. Skip the explanation when the patient appears calm.
    3. Tell the patient to remain silent until the tracing is finished.
    4. Apply the limb leads first and explain the test afterward.

    Explanation

    Explaining the procedure and inviting questions supports cooperation and reduces anxiety. The explanation should occur before electrode placement, not afterward.

  29. Question 29Patient Preparation, Safety, and Infection Control

    How should an adult patient be positioned for a routine 12-lead EKG?

    1. Seated upright with both feet flat on the floor.
    2. Standing with the arms raised above the head.
    3. Supine, with arms at the sides and legs uncrossed. Correct answer.
    4. Lying on the side with the knees drawn to the chest.

    Explanation

    A routine EKG is usually obtained with the patient supine, arms resting at the sides, and legs uncrossed to reduce muscle tension and artifact. Positioning should also maintain comfort and privacy.

  30. Question 30Patient Preparation, Safety, and Infection Control

    A patient reports that adhesive electrodes leave a red, itchy rash. What should the technician do?

    1. Use hypoallergenic electrodes and monitor the skin. Correct answer.
    2. Cancel the EKG because electrodes cannot be used.
    3. Apply lotion before attaching the standard electrodes.
    4. Place the standard electrodes over the previous rash.

    Explanation

    A history of adhesive reaction calls for a hypoallergenic or alternative electrode and observation of the skin. Standard adhesive electrodes should not be placed over already irritated skin.

  31. Question 31Patient Preparation, Safety, and Infection Control

    A patient with suspected influenza is on droplet precautions. Which PPE should the technician use for the EKG?

    1. A gown and gloves only, without a mask.
    2. No PPE if the EKG takes less than five minutes.
    3. A fit-tested N95 respirator alone, without gloves or gown.
    4. A surgical mask, plus gloves and gown for contact. Correct answer.

    Explanation

    Droplet precautions require a surgical mask for close contact. Standard precautions also require gloves and a gown when contact with the patient or contaminated items is expected.

  32. Question 32Patient Preparation, Safety, and Infection Control

    A patient with suspected active tuberculosis is in an airborne-infection isolation room. What should the technician do before entering?

    1. Enter without PPE and finish the EKG quickly.
    2. Put on a surgical mask and leave the room door open.
    3. Perform hand hygiene and use a fit-tested N95. Correct answer.
    4. Wear gloves only and keep the door closed.

    Explanation

    Airborne precautions for tuberculosis require a fit-tested N95 respirator or equivalent. Hand hygiene and standard precautions are also part of safe practice.

  33. Question 33Patient Preparation, Safety, and Infection Control

    A patient with MRSA in a wound is on contact precautions. How should the technician prepare for the EKG?

    1. Use the shared EKG machine without cleaning it afterward.
    2. Put on gown and gloves and clean equipment after use. Correct answer.
    3. Wear a surgical mask and no gown or gloves.
    4. Ask the patient to come to the hallway for the tracing.

    Explanation

    Contact precautions require gown and gloves for entering the room and touching the patient or contaminated surfaces. Reusable equipment should be cleaned or disinfected according to policy after use.

  34. Question 34Patient Preparation, Safety, and Infection Control

    The technician must enter a contact-isolation room and may contact body fluids. What is the correct order for donning PPE?

    1. Mask, gloves, gown, eye protection, and hand hygiene last.
    2. Hand hygiene, gown, mask, eye protection, gloves. Correct answer.
    3. Gown, gloves, hand hygiene, mask, eye protection.
    4. Gloves first, then gown, mask, eye protection, and hand hygiene last.

    Explanation

    PPE is donned after hand hygiene, with gloves applied last to cover the cuffs of the gown. This sequence reduces the chance of contaminating the gloves during application.

  35. Question 35Patient Preparation, Safety, and Infection Control

    After completing an EKG in a contact-isolation room, what is the correct order for removing PPE?

    1. Gloves, eye protection, gown, mask; then hand hygiene. Correct answer.
    2. Remove mask, then gown, then gloves, then eye protection.
    3. Remove gown, gloves, mask, eye protection; wash hands first.
    4. Remove eye protection, mask, gloves, then gown.

    Explanation

    PPE is removed in a sequence that avoids contaminating the face, generally gloves first, then eye protection, gown, and mask, followed by hand hygiene. The exact sequence should follow facility policy.

  36. Question 36Patient Preparation, Safety, and Infection Control

    A small amount of blood spills on the floor beside the EKG table. What should the technician do?

    1. Don gloves, absorb the spill, then disinfect. Correct answer.
    2. Wipe it with a dry paper towel and continue the EKG.
    3. Leave it for housekeeping and warn the patient.
    4. Pour water on it and mop it toward the drain.

    Explanation

    Blood spills are cleaned while wearing appropriate PPE, absorbed, and then disinfected with an approved agent for the required contact time. The area should be secured until cleanup is complete.

  37. Question 37Patient Preparation, Safety, and Infection Control

    A patient has a pacemaker generator visible on the upper chest. How should the technician place chest electrodes?

    1. Place all chest electrodes directly over the generator.
    2. Omit all chest leads to avoid the device.
    3. Move the generator aside before applying electrodes.
    4. Avoid an electrode directly over the generator. Correct answer.

    Explanation

    Chest electrodes should be placed at standard positions while avoiding direct placement over an implanted device generator when possible. This helps prevent artifact and follows common device-safety practice.

  38. Question 38Patient Preparation, Safety, and Infection Control

    A patient has oily skin at the chest electrode sites. What should the technician do to improve electrode contact?

    1. Apply a thin layer of lotion before placement.
    2. Scrub the skin until it is red and raw.
    3. Attach electrodes while the skin is still wet.
    4. Cleanse with alcohol and let the skin dry. Correct answer.

    Explanation

    Oily skin can prevent electrodes from adhering and can increase artifact. Cleansing with alcohol and allowing the skin to dry improves contact without damaging the skin.

  39. Question 39Patient Preparation, Safety, and Infection Control

    During preparation, the patient is sweating heavily on the chest. What should the technician do?

    1. Dry the skin and use fresh electrodes. Correct answer.
    2. Apply powder and leave it under the electrodes.
    3. Place electrodes over the moisture to save time.
    4. Stop the EKG and send the patient home.

    Explanation

    Moisture prevents electrodes from adhering and can create artifact. Drying the skin and using fresh electrodes improves contact.

  40. Question 40Patient Preparation, Safety, and Infection Control

    A school-age child is anxious about an EKG. How should the technician prepare the child?

    1. Apply the electrodes without explaining the procedure.
    2. Promise the child that the test will not cause any discomfort.
    3. Use simple words and let a caregiver stay nearby. Correct answer.
    4. Ask the parent to leave the room immediately.

    Explanation

    Children benefit from simple, age-appropriate explanations and reassurance. Allowing a caregiver to remain nearby, when consistent with policy, can reduce anxiety.

  41. Question 41Patient Preparation, Safety, and Infection Control

    A patient is deaf and reads lips. How should the technician communicate during the EKG?

    1. Ask another patient to interpret the instructions.
    2. Speak very loudly from another room.
    3. Proceed without giving any instructions.
    4. Face the patient and use written instructions. Correct answer.

    Explanation

    The technician should face the patient, speak clearly, and use written or visual aids as needed. A qualified interpreter should be used according to facility policy when necessary.

  42. Question 42Patient Preparation, Safety, and Infection Control

    The technician sees an isolation sign on a patient's door. What should be done before entering?

    1. Remove the sign so the equipment can be brought in.
    2. Bring the EKG machine in before putting on PPE.
    3. Read the sign and don the required PPE outside the room. Correct answer.
    4. Enter first to ask the patient which precautions apply.

    Explanation

    Isolation signage tells staff which precautions are required. PPE is applied before entering the room, using the correct sequence and equipment.

  43. Question 43Patient Preparation, Safety, and Infection Control

    When does standard precautions require the technician to wear gloves during an EKG?

    1. When contact with blood, body fluids, or nonintact skin is likely. Correct answer.
    2. Only after the electrodes have been attached.
    3. Only when the patient asks the technician to wear them.
    4. For every patient, even when no body fluid contact is expected.

    Explanation

    Gloves are required when contact with blood, body fluids, secretions, excretions, nonintact skin, or contaminated surfaces is anticipated. Gloves are not automatically required for every intact-skin contact.

  44. Question 44Patient Preparation, Safety, and Infection Control

    After an EKG, the reusable lead cables are visibly clean but were in contact with the patient. What should the technician do?

    1. Disinfect the cables with an approved agent. Correct answer.
    2. Spray the cables with alcohol while they are plugged in.
    3. Store the cables immediately for the next patient.
    4. Rinse the cables in water and hang them to dry.

    Explanation

    Reusable equipment that contacts patients must be cleaned or disinfected between patients according to facility policy and manufacturer instructions. Visible cleanliness alone does not replace disinfection.

  45. Question 45Patient Preparation, Safety, and Infection Control

    The patient's identification band is missing before an EKG. What is the best action?

    1. Write a new band by hand and apply it.
    2. Stop and follow facility policy to verify identity. Correct answer.
    3. Ask the roommate to confirm the patient's identity.
    4. Use the name on the door and begin the tracing.

    Explanation

    The EKG should not proceed until the patient's identity is verified using approved identifiers. The technician should follow facility policy to obtain proper identification.

  46. Question 46Patient Preparation, Safety, and Infection Control

    Before plugging in the EKG machine, what should the technician check?

    1. The number of tracings left in the paper tray.
    2. Whether the machine has a recent battery charge.
    3. Power cord and lead wires for damage. Correct answer.
    4. The patient's age and insurance information.

    Explanation

    Damaged cords or lead wires can cause electrical hazards or poor signal quality. Equipment should be inspected before use and taken out of service if damaged.

  47. Question 47Patient Preparation, Safety, and Infection Control

    A patient has a new productive cough but is not on isolation precautions. What should the technician do?

    1. Wear a gown but no mask during the tracing.
    2. Ask the patient to suppress the cough throughout the test.
    3. Refuse to perform the EKG until the cough resolves.
    4. Offer a mask and perform hand hygiene before contact. Correct answer.

    Explanation

    Source control, such as offering a mask, can reduce the spread of respiratory secretions. Standard precautions and hand hygiene should be used, and isolation precautions should be followed if they are later ordered.

  48. Question 48Patient Preparation, Safety, and Infection Control

    The EKG room is cold, and the patient is shivering before the tracing begins. What should the technician do?

    1. Warm the room or cover the patient, then proceed. Correct answer.
    2. Begin the tracing and ignore the shivering.
    3. Ask the patient to hold still despite the shivering.
    4. Place electrodes over the patient's clothing.

    Explanation

    Shivering causes muscle artifact and can make the tracing unreadable. Warming the room or covering the patient improves comfort and reduces artifact.

  49. Question 49Patient Preparation, Safety, and Infection Control

    The technician's hands are visibly soiled with blood after removing gloves. What should be done?

    1. Use an alcohol-based hand rub only.
    2. Wash with soap and water before continuing. Correct answer.
    3. Put on new gloves without washing the hands.
    4. Wipe the hands with a dry paper towel.

    Explanation

    When hands are visibly soiled with blood or body fluids, soap and water are required. Alcohol-based hand rub is not sufficient for visibly contaminated hands.

  50. Question 50Patient Preparation, Safety, and Infection Control

    A patient reports a skin allergy to alcohol. What should the technician use to prepare intact electrode sites?

    1. Alcohol pads, but only on the chest.
    2. No cleaning, because allergies prevent preparation.
    3. Mild soap and water, then dry the skin. Correct answer.
    4. An abrasive pad until the skin bleeds.

    Explanation

    When alcohol is not tolerated, mild soap and water can clean intact skin, followed by thorough drying. The technician should avoid agents that cause a reaction and should not damage the skin.

  51. Question 51Cardiovascular Anatomy, Physiology, and Electrophysiology

    Which chamber of the heart receives deoxygenated blood returning from the body through the venae cavae?

    1. Right atrium Correct answer.
    2. Left ventricle
    3. Right ventricle
    4. Left atrium

    Explanation

    Systemic venous blood returns to the right atrium through the superior and inferior venae cavae. From the right atrium it passes through the tricuspid valve into the right ventricle before being pumped to the lungs. Oxygenated blood returning from the lungs enters the left atrium through the pulmonary veins.

  52. Question 52Cardiovascular Anatomy, Physiology, and Electrophysiology

    Which valve is located between the left atrium and the left ventricle?

    1. Aortic valve
    2. Tricuspid valve
    3. Mitral valve Correct answer.
    4. Pulmonic valve

    Explanation

    The mitral (bicuspid) valve guards the opening between the left atrium and the left ventricle and prevents backflow during ventricular systole. The tricuspid valve occupies the same position on the right side of the heart. The aortic and pulmonic valves sit at the outflow tracts of the ventricles.

  53. Question 53Cardiovascular Anatomy, Physiology, and Electrophysiology

    What is the normal intrinsic firing rate of the sinoatrial node in a resting adult?

    1. 100 to 120 beats per minute
    2. 60 to 100 beats per minute Correct answer.
    3. 20 to 40 beats per minute
    4. 40 to 60 beats per minute

    Explanation

    The SA node normally fires 60 to 100 impulses per minute and therefore sets the pace of the heart. Lower pacemakers fire more slowly and take over only when the SA node fails or conduction is blocked. This hierarchy of firing rates is why the SA node is called the primary pacemaker.

  54. Question 54Cardiovascular Anatomy, Physiology, and Electrophysiology

    The P wave on a normal ECG records which electrical event?

    1. Ventricular depolarization
    2. Atrial repolarization
    3. Atrial depolarization Correct answer.
    4. Ventricular repolarization

    Explanation

    The P wave is the first deflection of the cardiac cycle and reflects depolarization of the atria spreading outward from the SA node. Atrial repolarization is a low-voltage event usually buried within the QRS complex. Ventricular events are recorded by the QRS complex and the T wave.

  55. Question 55Cardiovascular Anatomy, Physiology, and Electrophysiology

    Which electrical event does the QRS complex represent?

    1. Ventricular depolarization Correct answer.
    2. Ventricular repolarization
    3. Atrial repolarization
    4. Atrial depolarization

    Explanation

    The QRS complex records depolarization of the ventricular myocardium, which immediately precedes ventricular contraction. It is normally narrow because conduction through the His-Purkinje system is rapid. Atrial depolarization produces the P wave and ventricular repolarization produces the T wave.

  56. Question 56Cardiovascular Anatomy, Physiology, and Electrophysiology

    The T wave of a normal ECG represents which event?

    1. Atrial depolarization
    2. Ventricular depolarization
    3. Conduction through the AV node
    4. Ventricular repolarization Correct answer.

    Explanation

    The T wave records the return of ventricular muscle to its resting electrical state after contraction. Repolarization proceeds in the opposite direction to depolarization, which is why the T wave is normally upright in most leads. Atrial and ventricular depolarization produce the P wave and QRS complex.

  57. Question 57Cardiovascular Anatomy, Physiology, and Electrophysiology

    Which vessel carries deoxygenated blood from the right ventricle to the lungs?

    1. Pulmonary vein
    2. Superior vena cava
    3. Aorta
    4. Pulmonary artery Correct answer.

    Explanation

    The pulmonary artery is the only artery in the body that carries deoxygenated blood; it divides into right and left branches that deliver blood to the lungs. Oxygenated blood returns to the left atrium through the pulmonary veins. The aorta carries oxygenated blood to the systemic circulation.

  58. Question 58Cardiovascular Anatomy, Physiology, and Electrophysiology

    Which structure is a fibrous sac that encloses the heart and helps anchor it within the thorax?

    1. Myocardium
    2. Endocardium
    3. Pericardium Correct answer.
    4. Epicardium

    Explanation

    The pericardium is a double-layered sac surrounding the heart; its tough fibrous outer layer anchors the heart and limits overfilling. The myocardium, endocardium, and epicardium are layers of the heart wall itself rather than the surrounding sac.

  59. Question 59Cardiovascular Anatomy, Physiology, and Electrophysiology

    What is the main purpose of the normal delay in impulse conduction at the AV node?

    1. To stop impulses from reaching the ventricles
    2. To accelerate the impulse as it passes to the ventricles
    3. To let the atria finish filling the ventricles Correct answer.
    4. To take over pacing when the SA node fails

    Explanation

    The AV node slows conduction by roughly 0.1 second, allowing atrial contraction to complete ventricular filling before the ventricles contract. This delay is reflected in the PR interval on the ECG. Faster conduction would reduce filling time and lower cardiac output.

  60. Question 60Cardiovascular Anatomy, Physiology, and Electrophysiology

    The electrical impulse travels from the AV node directly into which structure?

    1. Bachmann bundle
    2. Sinoatrial node
    3. Bundle of His Correct answer.
    4. Purkinje fibers

    Explanation

    The bundle of His carries the impulse from the AV node through the interventricular septum, where it divides into the right and left bundle branches. Purkinje fibers are the terminal branches that deliver the impulse to ventricular muscle. The Bachmann bundle conducts between the two atria.

  61. Question 61Cardiovascular Anatomy, Physiology, and Electrophysiology

    What is the intrinsic escape rate of the Purkinje fiber network?

    1. 60 to 100 beats per minute
    2. 100 to 120 beats per minute
    3. 20 to 40 beats per minute Correct answer.
    4. 40 to 60 beats per minute

    Explanation

    Purkinje fibers are the slowest of the backup pacemakers, firing at about 20 to 40 impulses per minute. The SA node fires fastest and normally overrides all lower pacemakers. The AV junction fires at about 40 to 60 per minute.

  62. Question 62Cardiovascular Anatomy, Physiology, and Electrophysiology

    A normal PR interval measures:

    1. Less than 0.04 second
    2. 0.04 to 0.10 second
    3. 0.12 to 0.20 second Correct answer.
    4. 0.24 to 0.32 second

    Explanation

    The PR interval is measured from the start of the P wave to the start of the QRS complex and normally lasts 0.12 to 0.20 second, or three to five small boxes. It reflects atrial depolarization plus the delay at the AV node. A value above 0.20 second suggests first-degree AV block.

  63. Question 63Cardiovascular Anatomy, Physiology, and Electrophysiology

    A normal QRS complex is:

    1. 0.12 to 0.20 second
    2. Greater than 0.28 second
    3. 0.20 to 0.28 second
    4. Less than 0.12 second Correct answer.

    Explanation

    Normal conduction through the His-Purkinje system depolarizes both ventricles in less than 0.12 second, which is three small boxes. Widening beyond 0.12 second suggests delayed ventricular conduction such as a bundle branch block. The QRS is measured from the first to the last deflection of the complex.

  64. Question 64Cardiovascular Anatomy, Physiology, and Electrophysiology

    Cardiac output is calculated by:

    1. Dividing stroke volume by heart rate
    2. Multiplying stroke volume by systemic vascular resistance
    3. Multiplying heart rate by stroke volume Correct answer.
    4. Adding stroke volume to heart rate

    Explanation

    Cardiac output is the volume of blood pumped by one ventricle each minute, equal to heart rate multiplied by stroke volume. A resting adult ejects roughly 70 mL per beat at 70 beats per minute, or about 5 L per minute. A change in either factor alters output.

  65. Question 65Cardiovascular Anatomy, Physiology, and Electrophysiology

    Which statement best describes depolarization of a cardiac muscle cell?

    1. The inside of the cell becomes more negative than at rest
    2. Positive ions enter and the inside becomes less negative Correct answer.
    3. Potassium ions rush into the cell through open channels
    4. The cell membrane becomes impermeable to all ions

    Explanation

    Depolarization occurs when fast sodium channels open and positive ions enter the cell, reversing the negative resting membrane potential. This electrical change spreads from cell to cell and generates the waveforms seen on the ECG. Repolarization later restores the negative resting state.

  66. Question 66Cardiovascular Anatomy, Physiology, and Electrophysiology

    Stimulation of the sympathetic nervous system has which effect on the heart?

    1. Increased heart rate and contractility Correct answer.
    2. Slower heart rate
    3. Reduced force of ventricular contraction
    4. Slower conduction through the AV node

    Explanation

    Sympathetic fibers release norepinephrine, which raises the firing rate of the SA node, speeds AV nodal conduction, and increases myocardial contractility. The net effect is greater cardiac output to meet increased demand. Parasympathetic activity produces the opposite effects.

  67. Question 67Cardiovascular Anatomy, Physiology, and Electrophysiology

    Stimulation of the vagus nerve to the heart produces which effect?

    1. Increased force of contraction
    2. Acceleration of AV nodal conduction
    3. Slowing of the heart rate Correct answer.
    4. Increased cardiac output during exercise

    Explanation

    Parasympathetic fibers in the vagus nerve release acetylcholine, which slows SA node firing and AV nodal conduction. The result is a lower heart rate and reduced cardiac output at rest. Sympathetic stimulation produces the opposite response.

  68. Question 68Cardiovascular Anatomy, Physiology, and Electrophysiology

    Stroke volume is best defined as the:

    1. Volume ejected by one ventricle per beat Correct answer.
    2. Volume ejected by the heart in one minute
    3. Volume of blood in the atria at the end of diastole
    4. Volume of blood remaining in the ventricle after ejection

    Explanation

    Stroke volume is the amount of blood pumped out of one ventricle with each beat, normally about 70 mL at rest. Multiplying stroke volume by heart rate gives cardiac output. The blood left behind after ejection is the end-systolic volume.

  69. Question 69Cardiovascular Anatomy, Physiology, and Electrophysiology

    The first heart sound, S1, is caused by closure of which valves?

    1. Aortic and pulmonic valves
    2. Pulmonic and tricuspid valves
    3. Mitral and tricuspid valves Correct answer.
    4. Aortic and mitral valves

    Explanation

    S1 occurs at the start of ventricular systole when the mitral and tricuspid valves close. Closure of the aortic and pulmonic valves produces the second heart sound, S2, at the end of systole. S1 coincides with the QRS complex on the ECG.

  70. Question 70Cardiovascular Anatomy, Physiology, and Electrophysiology

    The QT interval measured on an ECG represents:

    1. Ventricular depolarization and repolarization Correct answer.
    2. Atrial depolarization and atrial repolarization
    3. Ventricular depolarization only
    4. Conduction time through the AV node

    Explanation

    The QT interval runs from the start of the QRS complex to the end of the T wave and covers both ventricular depolarization and repolarization. It varies with heart rate, so a rate-corrected value is often calculated. A prolonged QT raises the risk of dangerous ventricular arrhythmias.

  71. Question 71Cardiovascular Anatomy, Physiology, and Electrophysiology

    The left anterior descending coronary artery supplies which area of the heart?

    1. Right atrium and right ventricle
    2. Lateral wall of the left ventricle
    3. Posterior wall of the left ventricle
    4. Anterior wall and interventricular septum Correct answer.

    Explanation

    The LAD runs in the anterior interventricular groove and supplies the anterior left ventricular wall, the anterior portion of the septum, and the apex. Occlusion commonly produces an anterior myocardial infarction. The circumflex supplies the lateral wall, while the right coronary artery usually supplies the right heart and inferior wall.

  72. Question 72Cardiovascular Anatomy, Physiology, and Electrophysiology

    A 6-second rhythm strip contains 8 QRS complexes. What is the estimated heart rate?

    1. 60 beats per minute
    2. 80 beats per minute Correct answer.
    3. 90 beats per minute
    4. 120 beats per minute

    Explanation

    The 6-second method multiplies the number of QRS complexes in 6 seconds by 10 to estimate the rate per minute. Eight complexes times 10 gives 80 beats per minute. This method is useful for irregular rhythms, where the small-box method is less reliable.

  73. Question 73Cardiovascular Anatomy, Physiology, and Electrophysiology

    Which statement describes the Frank-Starling law of the heart?

    1. Cardiac output stays constant regardless of venous return
    2. Greater ventricular stretch during filling increases contractile force Correct answer.
    3. Heart rate is set solely by the SA node
    4. Contractility depends only on circulating epinephrine

    Explanation

    The Frank-Starling law states that within physiologic limits, greater filling stretches ventricular muscle and produces a stronger contraction, so more blood is ejected. This links venous return to cardiac output. Excessive stretch, as in heart failure, eventually reduces effectiveness.

  74. Question 74Cardiovascular Anatomy, Physiology, and Electrophysiology

    Phase 0 of the ventricular action potential is produced by:

    1. Efflux of potassium ions
    2. Rapid influx of sodium ions Correct answer.
    3. Influx of calcium through L-type channels
    4. Efflux of chloride ions

    Explanation

    Phase 0 is the rapid upstroke caused by opening of fast sodium channels and a large inward sodium current. The calcium current sustains the plateau in phase 2. Potassium efflux drives repolarization in phase 3.

  75. Question 75Cardiovascular Anatomy, Physiology, and Electrophysiology

    During the absolute refractory period, a cardiac muscle cell:

    1. Is fully repolarized and ready to fire
    2. Cannot be excited by any stimulus Correct answer.
    3. Conducts impulses faster than during rest
    4. Can be excited by a very strong stimulus

    Explanation

    The absolute refractory period covers most of depolarization and the plateau, while sodium channels are inactivated; no stimulus, however strong, can produce a new action potential. This protects the heart from tetanic contraction and limits how quickly the ventricles can be re-excited. A relative refractory period follows.

  76. Question 76Cardiovascular Anatomy, Physiology, and Electrophysiology

    Where is the sinoatrial (SA) node located?

    1. In the upper left atrium near the pulmonary veins
    2. Near the opening of the coronary sinus
    3. In the upper right atrium near the superior vena cava Correct answer.
    4. In the interatrial septum near the tricuspid valve

    Explanation

    The SA node is a small cluster of specialized pacemaker cells in the upper wall of the right atrium, close to where the superior vena cava enters. Because it depolarizes faster than any other pacemaker tissue, it normally sets the resting heart rate.

  77. Question 77Cardiovascular Anatomy, Physiology, and Electrophysiology

    Which cardiac chamber has the thickest myocardial wall?

    1. Left atrium
    2. Right ventricle
    3. Left ventricle Correct answer.
    4. Right atrium

    Explanation

    The left ventricle ejects blood against systemic arterial pressure, so it performs the greatest workload and develops the thickest myocardium. Wall thickness in each chamber follows the pressure it must generate.

  78. Question 78Cardiovascular Anatomy, Physiology, and Electrophysiology

    Which valve separates the right atrium from the right ventricle?

    1. Mitral valve
    2. Aortic valve
    3. Pulmonary valve
    4. Tricuspid valve Correct answer.

    Explanation

    The tricuspid valve sits between the right atrium and right ventricle and prevents backflow into the atrium during ventricular systole. Its leaflets are tethered by chordae tendineae attached to papillary muscles.

  79. Question 79Cardiovascular Anatomy, Physiology, and Electrophysiology

    What is the normal intrinsic firing rate of the SA node in an adult?

    1. 40 to 60 beats per minute
    2. 60 to 100 beats per minute Correct answer.
    3. 20 to 40 beats per minute
    4. 100 to 120 beats per minute

    Explanation

    The SA node normally fires about 60 to 100 times per minute, which establishes the resting sinus rate. Lower pacemakers fire more slowly and only take over when the SA node fails or is suppressed.

  80. Question 80Cardiovascular Anatomy, Physiology, and Electrophysiology

    Which vessel returns deoxygenated blood from the upper body to the right atrium?

    1. Pulmonary trunk
    2. Coronary sinus
    3. Inferior vena cava
    4. Superior vena cava Correct answer.

    Explanation

    The superior vena cava drains the head, neck, and upper extremities into the right atrium. The inferior vena cava handles the lower body, and the coronary sinus drains the heart itself.

  81. Question 81Cardiovascular Anatomy, Physiology, and Electrophysiology

    Which layer of the heart wall generates the force of contraction?

    1. Epicardium
    2. Myocardium Correct answer.
    3. Endocardium
    4. Fibrous pericardium

    Explanation

    The myocardium is the middle muscular layer, and its contracting fibers create the pressure that propels blood. The other layers provide covering, lining, or a friction-reducing surface.

  82. Question 82Cardiovascular Anatomy, Physiology, and Electrophysiology

    What is the approximate resting cardiac output of a healthy adult?

    1. 5 L/min Correct answer.
    2. 0.5 L/min
    3. 10 L/min
    4. 2 L/min

    Explanation

    Resting cardiac output averages about 5 L/min, roughly a stroke volume of 70 mL multiplied by a heart rate of 70 beats per minute. It can rise several-fold during exercise.

  83. Question 83Cardiovascular Anatomy, Physiology, and Electrophysiology

    Blood leaving the left atrium enters the left ventricle through which valve?

    1. Aortic valve
    2. Tricuspid valve
    3. Pulmonary valve
    4. Mitral valve Correct answer.

    Explanation

    Oxygenated blood flows from the left atrium through the mitral (bicuspid) valve into the left ventricle. This two-leaflet valve closes during systole to prevent backflow into the atrium.

  84. Question 84Cardiovascular Anatomy, Physiology, and Electrophysiology

    What is the function of the papillary muscles and chordae tendineae?

    1. They conduct electrical impulses from atria to ventricles
    2. They hold the AV valves closed during ventricular systole Correct answer.
    3. They generate the pressure that drives blood into the atria
    4. They open the semilunar valves during ventricular ejection

    Explanation

    During systole the papillary muscles contract and tighten the chordae tendineae, preventing the AV valve leaflets from prolapsing into the atria. This keeps the valve competent without actively opening it.

  85. Question 85Cardiovascular Anatomy, Physiology, and Electrophysiology

    Into which chamber does the coronary sinus empty?

    1. Right atrium Correct answer.
    2. Left atrium
    3. Left ventricle
    4. Right ventricle

    Explanation

    The coronary sinus is a venous channel that collects blood from the coronary veins and empties into the right atrium near the inferior vena cava opening. From there the blood passes to the right ventricle and then to the lungs.

  86. Question 86Cardiovascular Anatomy, Physiology, and Electrophysiology

    The second heart sound (S2) is produced by closure of which valves?

    1. Aortic and pulmonic Correct answer.
    2. Mitral and aortic
    3. Tricuspid and pulmonic
    4. Mitral and tricuspid

    Explanation

    S2 occurs at the end of ventricular systole when the aortic and pulmonic valves close. S1, by contrast, results from closure of the mitral and tricuspid valves at the start of systole.

  87. Question 87Cardiovascular Anatomy, Physiology, and Electrophysiology

    Preload is best described as the:

    1. Pressure in the aorta during diastole
    2. Degree of ventricular stretch at the end of diastole Correct answer.
    3. Volume of blood ejected with each beat
    4. Resistance the ventricle must overcome to eject blood

    Explanation

    Preload is the stretch placed on ventricular muscle fibers at end diastole and is determined mainly by venous return. Within physiologic limits, greater stretch produces a stronger contraction, as described by the Frank-Starling relationship.

  88. Question 88Cardiovascular Anatomy, Physiology, and Electrophysiology

    Afterload refers to which of the following?

    1. The stretch of the atrial wall during filling
    2. The resistance the ventricle must overcome to eject blood Correct answer.
    3. The amount of blood ejected per minute
    4. The volume of blood in the ventricle before contraction

    Explanation

    Afterload is the load the ventricle must overcome to open the semilunar valve and eject blood, driven largely by systemic vascular resistance and arterial pressure. Increased afterload raises myocardial oxygen demand and can reduce stroke volume.

  89. Question 89Cardiovascular Anatomy, Physiology, and Electrophysiology

    The plateau phase (phase 2) of the ventricular action potential is maintained mainly by:

    1. Rapid influx of sodium ions
    2. Slow influx of calcium ions Correct answer.
    3. Chloride movement into the cell
    4. Efflux of potassium through gap junctions

    Explanation

    During phase 2, slow inward calcium current through L-type channels balances outward potassium current, holding the membrane potential near zero. This plateau lengthens the action potential and produces the long refractory period of ventricular muscle.

  90. Question 90Cardiovascular Anatomy, Physiology, and Electrophysiology

    Spontaneous depolarization during phase 4 of a pacemaker cell action potential is caused mainly by:

    1. A steadily increasing inward sodium current Correct answer.
    2. Rapid calcium release from the sarcoplasmic reticulum
    3. Closure of gap junctions between cells
    4. Opening of voltage-gated potassium channels

    Explanation

    Pacemaker cells have no stable resting potential; an inward sodium current (the funny current) together with declining potassium efflux slowly drifts the membrane toward threshold. This drift is the basis of automaticity.

  91. Question 91Cardiovascular Anatomy, Physiology, and Electrophysiology

    A drug that has a positive inotropic effect on the heart does which of the following?

    1. It increases the heart rate
    2. It reduces venous return to the heart
    3. It slows conduction through the AV node
    4. It increases the force of myocardial contraction Correct answer.

    Explanation

    Inotropy refers to contractile strength, so a positive inotropic agent increases the force of contraction, usually by raising intracellular calcium. Rate effects are called chronotropic and conduction effects are called dromotropic.

  92. Question 92Cardiovascular Anatomy, Physiology, and Electrophysiology

    Which sequence correctly traces blood through the right side of the heart and into the lungs?

    1. Right atrium, tricuspid valve, right ventricle, pulmonary artery, lungs Correct answer.
    2. Right atrium, pulmonary vein, right ventricle, pulmonary artery, lungs
    3. Right atrium, tricuspid valve, lungs, pulmonary artery, right ventricle
    4. Right ventricle, tricuspid valve, right atrium, pulmonary vein, lungs

    Explanation

    Deoxygenated blood enters the right atrium, crosses the tricuspid valve into the right ventricle, and is ejected through the pulmonic valve into the pulmonary artery toward the lungs. The pulmonary veins then return oxygenated blood to the left atrium.

  93. Question 93Cardiovascular Anatomy, Physiology, and Electrophysiology

    What is the role of gap junctions in cardiac muscle?

    1. They store calcium needed for contraction
    2. They insulate atrial cells from ventricular cells
    3. They anchor adjacent cells so they do not pull apart
    4. They allow electrical current to pass from cell to cell Correct answer.

    Explanation

    Gap junctions are low-resistance channels that let depolarization spread directly between adjacent cardiomyocytes, so the myocardium behaves as a functional syncytium. Mechanical attachment is instead provided by desmosomes.

  94. Question 94Cardiovascular Anatomy, Physiology, and Electrophysiology

    A normal left ventricular ejection fraction is approximately:

    1. 20% to 35%
    2. 55% to 70% Correct answer.
    3. 75% to 95%
    4. 35% to 50%

    Explanation

    Ejection fraction is stroke volume divided by end-diastolic volume, and a normal left ventricular value is roughly 55% to 70%. Values below this range suggest impaired systolic function.

  95. Question 95Cardiovascular Anatomy, Physiology, and Electrophysiology

    During isovolumetric ventricular contraction, which statement is true?

    1. Ventricular volume is decreasing rapidly
    2. Blood is flowing from the ventricles into the great arteries
    3. The mitral valve is open and the aortic valve is closed
    4. All four valves are closed and ventricular pressure is rising Correct answer.

    Explanation

    Isovolumetric contraction begins after the AV valves close and before the semilunar valves open, so all valves are closed while pressure rises sharply. Ejection starts only when ventricular pressure exceeds aortic and pulmonary pressures.

  96. Question 96Cardiovascular Anatomy, Physiology, and Electrophysiology

    In most people, the sinoatrial node receives its blood supply from which artery?

    1. Right coronary artery Correct answer.
    2. Left anterior descending artery
    3. Left circumflex artery
    4. Left main coronary artery

    Explanation

    In roughly 60% of people the SA node artery branches from the right coronary artery, with the left circumflex supplying it in most of the remainder. This explains why right coronary occlusion can produce sinus bradycardia or sinus arrest.

  97. Question 97Cardiovascular Anatomy, Physiology, and Electrophysiology

    Mean arterial pressure is estimated as the product of which two factors?

    1. Heart rate and ejection fraction
    2. Cardiac output and heart rate
    3. Cardiac output and systemic vascular resistance Correct answer.
    4. Stroke volume and preload

    Explanation

    Mean arterial pressure approximates cardiac output multiplied by systemic vascular resistance, with right atrial pressure treated as negligible. It represents the average driving pressure for organ perfusion.

  98. Question 98Cardiovascular Anatomy, Physiology, and Electrophysiology

    Stretching of the atrial walls by increased venous return triggers which reflex?

    1. Cushing reflex, which decreases heart rate
    2. Bainbridge reflex, which increases heart rate Correct answer.
    3. Chemoreceptor reflex, which decreases heart rate
    4. Baroreceptor reflex, which increases heart rate

    Explanation

    The Bainbridge reflex responds to atrial stretch from increased venous return by raising heart rate so the extra volume can be moved forward. It is mediated by vagal afferents and increased sympathetic outflow to the SA node.

  99. Question 99Cardiovascular Anatomy, Physiology, and Electrophysiology

    The upstroke (phase 0) of the SA node action potential is produced mainly by:

    1. Sodium efflux through the sodium-potassium pump
    2. Calcium influx through slow channels Correct answer.
    3. Rapid sodium influx through fast channels
    4. Potassium influx through inward rectifier channels

    Explanation

    SA nodal cells lack fast sodium channels, so their upstroke depends on calcium entering through slow L-type channels. This slower upstroke helps explain why nodal conduction is slower than conduction in Purkinje fibers.

  100. Question 100Cardiovascular Anatomy, Physiology, and Electrophysiology

    Which coronary artery runs along the left atrioventricular groove and supplies the lateral wall of the left ventricle?

    1. Left circumflex artery Correct answer.
    2. Left anterior descending artery
    3. Right coronary artery
    4. Left main coronary artery

    Explanation

    The left circumflex artery travels in the left atrioventricular groove and supplies the lateral, and often posterior, left ventricular wall. The left anterior descending artery instead runs in the anterior interventricular groove.

  101. Question 101EKG Equipment, Lead Placement, and Tracing Acquisition

    At which landmark should the V2 electrode be placed for a standard 12-lead EKG?

    1. Fourth intercostal space, right sternal border
    2. Fifth intercostal space, left midclavicular line
    3. Fifth intercostal space, left anterior axillary line
    4. Fourth intercostal space, left sternal border Correct answer.

    Explanation

    V2 sits in the fourth intercostal space directly beside the left edge of the sternum, mirroring V1 on the right. The fourth and fifth intercostal spaces are counted down from the second intercostal space, which is located just below the angle of Louis.

  102. Question 102EKG Equipment, Lead Placement, and Tracing Acquisition

    What is the standard calibration used when recording a 12-lead EKG on paper?

    1. 5 mm/mV at 50 mm/s
    2. 10 mm/mV at 25 mm/s Correct answer.
    3. 10 mm/mV at 50 mm/s
    4. 20 mm/mV at 25 mm/s

    Explanation

    Standard calibration is 10 mm of vertical deflection per millivolt and a paper speed of 25 mm per second, so one small box equals 0.04 second horizontally. A calibration mark of 10 mm is printed at the start of the tracing to confirm these settings.

  103. Question 103EKG Equipment, Lead Placement, and Tracing Acquisition

    Which lead is most often recorded as the continuous rhythm strip at the bottom of a 12-lead tracing?

    1. Lead aVR
    2. Lead V1
    3. Lead V5
    4. Lead II Correct answer.

    Explanation

    Lead II is aligned with the heart's general axis, so it usually shows tall, clearly defined P waves and QRS complexes that are easy to measure. A continuous lead II strip allows rhythm changes to be tracked across the full recording.

  104. Question 104EKG Equipment, Lead Placement, and Tracing Acquisition

    A patient has dry, flaky skin at the electrode sites. Which action best improves signal quality?

    1. Press each electrode firmly for at least 30 seconds
    2. Apply lotion to the sites before attaching electrodes
    3. Gently abrade the skin with gauze or a rough pad Correct answer.
    4. Wipe the sites once with alcohol and apply immediately

    Explanation

    Dead, dry skin cells create high electrical resistance between the electrode and the body. Light abrasion removes the outer layer and lowers impedance so the signal is cleaner.

  105. Question 105EKG Equipment, Lead Placement, and Tracing Acquisition

    Using AHA color coding, which limb electrode is green?

    1. Right leg Correct answer.
    2. Left arm
    3. Right arm
    4. Left leg

    Explanation

    In the AHA system the right leg electrode is green, the right arm is white, the left arm is black, and the left leg is red. The right leg electrode serves as the electrical ground for the recording.

  106. Question 106EKG Equipment, Lead Placement, and Tracing Acquisition

    The V1 electrode is correctly placed at which location?

    1. Fourth intercostal space, right sternal border Correct answer.
    2. Second intercostal space, right sternal border
    3. Fifth intercostal space, right midclavicular line
    4. Fourth intercostal space, left sternal border

    Explanation

    V1 is placed in the fourth intercostal space at the right sternal border, and V2 mirrors it on the left. Placing V1 any higher or lower distorts the R-wave progression across the precordium.

  107. Question 107EKG Equipment, Lead Placement, and Tracing Acquisition

    A patient with a thick mat of chest hair has persistent artifact in leads V1 through V3. What is the best action?

    1. Clip or shave the hair at the electrode sites Correct answer.
    2. Move the chest leads to the opposite side of the chest
    3. Apply extra conductive gel over the hair
    4. Increase the paper speed to 50 mm/s

    Explanation

    Hair lifts electrodes off the skin and traps air, raising impedance and producing artifact. Clipping or shaving only the electrode sites restores reliable skin contact without changing lead position.

  108. Question 108EKG Equipment, Lead Placement, and Tracing Acquisition

    Where is the V6 electrode placed?

    1. Fifth intercostal space, left parasternal line
    2. Fifth intercostal space, left midaxillary line Correct answer.
    3. Fourth intercostal space, left midclavicular line
    4. Fifth intercostal space, left anterior axillary line

    Explanation

    V6 sits in the fifth intercostal space at the midaxillary line, at the same horizontal level as V4 and V5. It is the last of the six standard precordial positions.

  109. Question 109EKG Equipment, Lead Placement, and Tracing Acquisition

    Lead I displays the voltage difference between which two electrodes?

    1. Right arm positive, left arm negative
    2. Left arm positive, right arm negative Correct answer.
    3. Left leg positive, right arm negative
    4. Left leg positive, left arm negative

    Explanation

    Lead I is a bipolar limb lead that records the potential at the left arm relative to the right arm. Because the left arm is the positive input, an impulse traveling toward the left arm produces an upright deflection in lead I.

  110. Question 110EKG Equipment, Lead Placement, and Tracing Acquisition

    In lead aVR, which electrode acts as the positive exploring electrode?

    1. Left arm
    2. Left leg
    3. Right arm Correct answer.
    4. Right leg

    Explanation

    aVR is an augmented lead that uses the right arm as its positive electrode and averages the left arm and left leg as the negative reference. Because the normal wave of depolarization travels away from the right shoulder, aVR normally shows negative P, QRS, and T deflections.

  111. Question 111EKG Equipment, Lead Placement, and Tracing Acquisition

    A tracing shows a thick, fuzzy baseline in every lead caused by 60-Hz electrical interference. What is the most appropriate first step?

    1. Increase the gain to 20 mm/mV
    2. Ask the patient to hold their breath
    3. Check electrode contact and move cables away from electrical equipment Correct answer.
    4. Reorder the chest leads on the patient

    Explanation

    AC interference usually enters through poor electrode contact or from nearby electrical devices and unshielded cables. Verifying secure electrodes and relocating the cables away from power sources corrects most cases.

  112. Question 112EKG Equipment, Lead Placement, and Tracing Acquisition

    A slow, undulating rise and fall of the baseline in all leads that matches the patient's breathing rate is caused by what?

    1. Chest movement altering electrode-skin contact during respiration Correct answer.
    2. 60-Hz electrical interference
    3. Skeletal muscle tremor
    4. A broken lead wire

    Explanation

    Baseline wander during respiration results from the chest wall moving and from changes in skin impedance as the chest expands and relaxes. Helping the patient relax and breathe quietly, and ensuring flexible lead slack, minimizes the drift.

  113. Question 113EKG Equipment, Lead Placement, and Tracing Acquisition

    For a right-sided EKG, where is V4R placed?

    1. Fourth intercostal space, left midclavicular line
    2. Fourth intercostal space, right sternal border
    3. Fifth intercostal space, right midclavicular line Correct answer.
    4. Fifth intercostal space, right anterior axillary line

    Explanation

    Right-sided leads mirror the standard positions across the sternum, so V4R sits in the fifth intercostal space at the right midclavicular line. V4R is the lead most often used when assessing right ventricular involvement.

  114. Question 114EKG Equipment, Lead Placement, and Tracing Acquisition

    Where is lead V7 placed when posterior leads are recorded?

    1. Fifth intercostal space, left midaxillary line
    2. Fifth intercostal space, left posterior axillary line Correct answer.
    3. Fifth intercostal space, left anterior axillary line
    4. Fourth intercostal space, left paraspinal line

    Explanation

    Posterior leads continue around the back at the same horizontal level as V4 through V6, so V7 is placed in the fifth intercostal space at the posterior axillary line. V8 and V9 continue medially toward the spine.

  115. Question 115EKG Equipment, Lead Placement, and Tracing Acquisition

    At a paper speed of 25 mm/s, an R-R interval spanning 4 large boxes corresponds to which heart rate?

    1. 100 bpm
    2. 150 bpm
    3. 60 bpm
    4. 75 bpm Correct answer.

    Explanation

    At 25 mm/s each large box represents 0.20 second, and 4 large boxes equal 0.80 second. Dividing 60 seconds by 0.80 second gives 75 beats per minute, which also matches the 300-divided-by-large-boxes shortcut.

  116. Question 116EKG Equipment, Lead Placement, and Tracing Acquisition

    The QRS complexes in all leads measure only 3 mm in height and are hard to evaluate. Which adjustment should the technician make?

    1. Decrease the gain to 5 mm/mV
    2. Switch the rhythm strip to lead V1
    3. Increase the paper speed to 50 mm/s
    4. Increase the gain to 20 mm/mV Correct answer.

    Explanation

    Changing the gain to 20 mm/mV doubles the vertical deflection, so a 3-mm complex becomes 6 mm and is easier to measure. The altered calibration must be noted on the tracing so amplitudes are not misread.

  117. Question 117EKG Equipment, Lead Placement, and Tracing Acquisition

    Which finding indicates that the left arm and right arm electrodes have been interchanged?

    1. A flat line in lead aVL with normal limb leads
    2. Complete inversion of lead I, including a negative P wave Correct answer.
    3. Loss of R-wave progression across leads V1 through V6
    4. Inversion of the QRS complexes in leads II, III, and aVF

    Explanation

    Reversing the arm electrodes inverts the polarity of lead I, so its P wave, QRS complex, and T wave all point downward. Lead aVR and aVL also exchange places, while the precordial leads remain unaffected.

  118. Question 118EKG Equipment, Lead Placement, and Tracing Acquisition

    Fine, irregular oscillations obscure the baseline while a patient is shivering. What is the best way to correct this artifact?

    1. Warm the patient and encourage relaxation of the muscles Correct answer.
    2. Turn the notch filter up to remove all frequencies
    3. Move the limb electrodes onto the chest
    4. Record at 50 mm/s paper speed

    Explanation

    Somatic tremor is produced by involuntary skeletal muscle activity, so the tracing improves only when the muscles relax. Warming the room, supporting the limbs, and reassuring the patient reduce shivering.

  119. Question 119EKG Equipment, Lead Placement, and Tracing Acquisition

    How should the technician place V4 and V5 on a patient with large breasts?

    1. On the chest wall beneath the breast tissue Correct answer.
    2. One intercostal space lower than usual
    3. On top of the breast tissue at the standard intercostal level
    4. Replaced with right-sided leads V4R and V5R

    Explanation

    Chest leads must rest on the rib cage so the electrode sits at a consistent distance from the heart. Placing V4 and V5 beneath the breast tissue keeps the standard intercostal landmarks while avoiding the added distance and variable tissue of the breast.

  120. Question 120EKG Equipment, Lead Placement, and Tracing Acquisition

    All leads record normally except aVL, which shows a completely flat line. What is the most likely cause?

    1. The paper speed is set incorrectly
    2. The gain is set too high
    3. 60-Hz interference from nearby equipment
    4. A disconnected or broken left arm lead wire Correct answer.

    Explanation

    A flat line limited to leads that depend on one electrode points to a fault in that electrode or its wire. Lead aVL uses the left arm as its positive electrode, so a failed left arm connection abolishes that lead while others still record.

  121. Question 121EKG Equipment, Lead Placement, and Tracing Acquisition

    A tracing shows an inverted P wave and inverted QRS in lead I, with R-wave amplitude that decreases from V1 to V6. What should the technician do next?

    1. Repeat the tracing with the chest leads placed on the right chest Correct answer.
    2. Record at 50 mm/s and recalculate the rate
    3. Repeat the tracing with the arm electrodes reversed
    4. Increase the gain to 20 mm/mV

    Explanation

    Together, a negative lead I and reverse R-wave progression indicate the heart may lie on the right side, as in dextrocardia or arm lead reversal. When true dextrocardia is suspected, right-sided precordial leads are recorded to show the true orientation of the ventricles.

  122. Question 122EKG Equipment, Lead Placement, and Tracing Acquisition

    Which statement about the 50/60-Hz notch filter on an EKG machine is accurate?

    1. It corrects artifact caused by a reversed limb lead
    2. It removes baseline drift caused by respiration
    3. It raises the amplitude of low-voltage complexes
    4. It reduces AC interference but may blunt narrow pacemaker spikes Correct answer.

    Explanation

    The notch filter is tuned to reject the frequency of the local power supply, which cleans up interference from nearby electrical sources. Because pacemaker spikes contain high-frequency content, filtering can flatten or hide them.

  123. Question 123EKG Equipment, Lead Placement, and Tracing Acquisition

    Which pattern suggests that the right arm and left leg electrodes have been interchanged?

    1. Complete inversion of lead I with a negative P wave
    2. Inverted QRS complexes in leads II, III, and aVF Correct answer.
    3. Loss of R-wave progression across the precordium
    4. A flat line in lead aVL with otherwise normal limb leads

    Explanation

    Swapping the right arm and left leg electrodes reverses the polarity of the inferior leads, so leads II, III, and aVF appear inverted along with their P waves. Lead I remains upright but is replaced by an inverted lead III.

  124. Question 124EKG Equipment, Lead Placement, and Tracing Acquisition

    An EKG is recorded at a paper speed of 50 mm/s, and the R-R interval measures 30 small boxes. What is the heart rate?

    1. 100 bpm Correct answer.
    2. 50 bpm
    3. 75 bpm
    4. 150 bpm

    Explanation

    At 50 mm/s each small box equals 0.02 second, so 30 small boxes equal 0.60 second. Sixty seconds divided by 0.60 second gives 100 beats per minute.

  125. Question 125EKG Equipment, Lead Placement, and Tracing Acquisition

    What effect can placing V1 and V2 one intercostal space too high have on the tracing?

    1. It produces 60-Hz interference in the precordial leads
    2. It doubles the amplitude of the P wave
    3. It can create a pseudoinfarct pattern with poor R-wave progression or small q waves Correct answer.
    4. It reverses the polarity of lead I

    Explanation

    Too-high chest leads record electrical activity from a higher, more basal portion of the heart, which can mimic loss of anterior forces. The resulting small q waves and poor R-wave progression may falsely suggest an anteroseptal infarct.

  126. Question 126EKG Equipment, Lead Placement, and Tracing Acquisition

    Which electrode is placed on the right leg for a standard 12-lead EKG?

    1. Exploring electrode for lead V4
    2. Ground electrode Correct answer.
    3. Negative electrode for lead aVL
    4. Positive electrode for lead II

    Explanation

    The right leg electrode is the neutral ground. It helps the machine reject electrical interference and is not part of any bipolar or augmented limb lead.

  127. Question 127EKG Equipment, Lead Placement, and Tracing Acquisition

    What should the technician do before applying electrodes to a diaphoretic patient?

    1. Lower the machine gain to 5 mm/mV
    2. Place all chest electrodes over the sternum
    3. Wipe the skin dry and use fresh adhesive electrodes Correct answer.
    4. Apply lotion to improve adhesion

    Explanation

    Moisture raises skin-electrode impedance and promotes artifact. Drying the skin and using fresh adhesive electrodes gives a stable tracing.

  128. Question 128EKG Equipment, Lead Placement, and Tracing Acquisition

    Where is electrode V3 placed?

    1. Fifth intercostal space at the left midaxillary line
    2. Fifth intercostal space at the left anterior axillary line
    3. Fourth intercostal space at the left sternal border
    4. Midway between V2 and V4 Correct answer.

    Explanation

    V3 is placed halfway between V2 and V4. This places it over the anterior chest between the parasternal and midclavicular positions.

  129. Question 129EKG Equipment, Lead Placement, and Tracing Acquisition

    At 25 mm/s, one small box horizontally represents which duration?

    1. 0.04 second Correct answer.
    2. 0.20 second
    3. 0.08 second
    4. 0.40 second

    Explanation

    At 25 mm/s, each small box (1 mm) equals 0.04 second. Five small boxes make one large box, which equals 0.20 second.

  130. Question 130EKG Equipment, Lead Placement, and Tracing Acquisition

    What does a standard EKG calibration of 10 mm/mV indicate?

    1. A 10-mV signal produces a 1-mm deflection
    2. The paper moves 10 mm each second
    3. A 1-mV signal produces a 10-mm deflection Correct answer.
    4. Each large box represents 10 mV

    Explanation

    At 10 mm/mV, a 1-mV electrical signal moves the trace 10 mm vertically. This standard lets providers compare wave heights between tracings.

  131. Question 131EKG Equipment, Lead Placement, and Tracing Acquisition

    Which lead is usually chosen for a continuous rhythm strip during a 12-lead EKG?

    1. Lead aVR
    2. Lead II Correct answer.
    3. Lead V1
    4. Lead V6

    Explanation

    Lead II is commonly used because its axis usually aligns with atrial depolarization, giving a clear positive P wave. It also provides a stable view of the QRS for rhythm analysis.

  132. Question 132EKG Equipment, Lead Placement, and Tracing Acquisition

    Where is electrode V4 placed?

    1. Fourth intercostal space at the left sternal border
    2. Fifth intercostal space at the left midaxillary line
    3. Fifth intercostal space at the left anterior axillary line
    4. Fifth intercostal space at the left midclavicular line Correct answer.

    Explanation

    V4 is placed in the fifth intercostal space at the left midclavicular line. It sits at the same horizontal level as V5 and V6.

  133. Question 133EKG Equipment, Lead Placement, and Tracing Acquisition

    What is the standard paper speed for a resting 12-lead EKG in the United States?

    1. 10 mm/s
    2. 5 mm/s
    3. 25 mm/s Correct answer.
    4. 50 mm/s

    Explanation

    The standard is 25 mm/s, at which one small box equals 0.04 second. Some rhythm or pediatric recordings may use 50 mm/s, but 25 mm/s is the resting standard.

  134. Question 134EKG Equipment, Lead Placement, and Tracing Acquisition

    Lead III records the voltage difference between which two electrodes?

    1. Left leg and right arm
    2. Right arm and left arm
    3. Left leg and left arm Correct answer.
    4. Left arm and right leg

    Explanation

    Lead III compares the left leg (positive) with the left arm (negative). Leads I and II use different limb pairs.

  135. Question 135EKG Equipment, Lead Placement, and Tracing Acquisition

    Which group lists only augmented unipolar limb leads?

    1. V1, V2, and V3
    2. V4, V5, and V6
    3. aVR, aVL, and aVF Correct answer.
    4. I, II, and III

    Explanation

    The augmented limb leads are aVR, aVL, and aVF. They use one limb as the exploring electrode and combine the other two as the reference.

  136. Question 136EKG Equipment, Lead Placement, and Tracing Acquisition

    At 25 mm/s, an R-R interval of 15 small boxes corresponds to which heart rate?

    1. 75 bpm
    2. 60 bpm
    3. 150 bpm
    4. 100 bpm Correct answer.

    Explanation

    At 25 mm/s, heart rate can be estimated by dividing 1500 by the number of small boxes between R waves. 1500 divided by 15 equals 100 bpm.

  137. Question 137EKG Equipment, Lead Placement, and Tracing Acquisition

    At 25 mm/s, how long is a 10-second EKG recording on paper?

    1. 100 mm
    2. 250 mm Correct answer.
    3. 25 mm
    4. 500 mm

    Explanation

    At 25 mm/s, 10 seconds of recording uses 25 mm per second times 10 seconds, or 250 mm. This is the usual width of a standard 12-lead page.

  138. Question 138EKG Equipment, Lead Placement, and Tracing Acquisition

    If the gain is set to 5 mm/mV, how tall will a 1-mV calibration signal appear?

    1. 2 mm
    2. 20 mm
    3. 5 mm Correct answer.
    4. 10 mm

    Explanation

    Gain expresses how many millimeters the trace moves per millivolt. At 5 mm/mV, a 1-mV signal produces a 5-mm deflection, which is half the standard height.

  139. Question 139EKG Equipment, Lead Placement, and Tracing Acquisition

    Which filter is used to reduce artifact caused by skeletal muscle tremor?

    1. 60-Hz notch filter
    2. Low-frequency filter
    3. Muscle tremor (EMG) filter Correct answer.
    4. Calibration pulse filter

    Explanation

    Skeletal muscle activity produces high-frequency artifact, so a muscle tremor or EMG filter is used. The notch filter targets 60-Hz electrical interference instead.

  140. Question 140EKG Equipment, Lead Placement, and Tracing Acquisition

    Where should chest electrodes be placed on a patient with an implanted pacemaker generator in the left infraclavicular area?

    1. On the abdomen instead of the chest
    2. Away from the generator while following normal sites as closely as possible Correct answer.
    3. Only on the right side of the chest
    4. Directly over the generator

    Explanation

    Chest electrodes should avoid the pacemaker generator and leads while staying as close to standard positions as possible. This reduces the risk of interference and discomfort.

  141. Question 141EKG Equipment, Lead Placement, and Tracing Acquisition

    Why should limb electrodes be placed on fleshy areas rather than over bony prominences?

    1. Bone tissue produces a calibration pulse
    2. Bony areas increase the paper speed
    3. Bone provides poorer skin contact and more artifact Correct answer.
    4. Bone blocks all electrical signal from the heart

    Explanation

    Fleshy areas give better skin-electrode contact and lower impedance. Bony prominences have less soft tissue and tend to produce more artifact.

  142. Question 142EKG Equipment, Lead Placement, and Tracing Acquisition

    How does recording at 50 mm/s instead of 25 mm/s change the tracing?

    1. It doubles the height of the QRS complexes
    2. It automatically removes baseline artifact
    3. It spreads waveforms farther apart horizontally Correct answer.
    4. It halves the displayed heart rate

    Explanation

    Increasing paper speed moves the paper faster, so each waveform occupies more horizontal space. Vertical amplitude is unchanged because gain controls height.

  143. Question 143EKG Equipment, Lead Placement, and Tracing Acquisition

    During recording, lead V2 shows intermittent sharp spikes while all other leads are clean. What is the most likely cause?

    1. 60-Hz interference from the room
    2. Incorrect paper speed
    3. Patient respiration
    4. Poor contact at the V2 electrode Correct answer.

    Explanation

    Artifact confined to one lead usually points to a problem at that electrode, such as poor adhesion or dried gel. Replacing or reseating the V2 electrode usually resolves it.

  144. Question 144EKG Equipment, Lead Placement, and Tracing Acquisition

    What is the purpose of the standardization mark at the start of an EKG?

    1. It displays the patient's heart rate
    2. It marks the start of the rhythm strip
    3. It confirms the voltage calibration of the machine Correct answer.
    4. It shows the paper speed in millimeters per second

    Explanation

    The standardization mark is a known 1-mV calibration pulse, usually 10 mm tall at standard gain. It verifies that the machine's voltage scale is accurate.

  145. Question 145EKG Equipment, Lead Placement, and Tracing Acquisition

    In lead II, which electrode is positive and which is negative?

    1. Left leg positive, right arm negative Correct answer.
    2. Left arm positive, right arm negative
    3. Left leg positive, left arm negative
    4. Right arm positive, left leg negative

    Explanation

    Lead II uses the left leg as the positive exploring electrode and the right arm as the negative reference. This orientation usually produces a positive P wave.

  146. Question 146EKG Equipment, Lead Placement, and Tracing Acquisition

    Which statement describes correct placement of posterior leads V8 and V9?

    1. V8 at the left midscapular line; V9 at the left paraspinal border, at the V6 level Correct answer.
    2. V8 at the left paraspinal border; V9 at the right paraspinal border, at the scapular tip
    3. V8 on the right midclavicular line; V9 on the right sternal border, at the fourth intercostal space
    4. V8 at the left anterior axillary line; V9 at the left midclavicular line, both in the fifth intercostal space

    Explanation

    Posterior leads are placed on the back at the same horizontal level as V6. V8 sits at the left midscapular line and V9 at the left paraspinal border.

  147. Question 147EKG Equipment, Lead Placement, and Tracing Acquisition

    Which pattern suggests that the left arm and left leg electrodes were interchanged?

    1. Lead I is inverted while leads II and III remain unchanged and chest R-wave progression is normal
    2. Lead aVR is flat while all chest leads remain normal
    3. The R wave fails to progress from V1 to V6
    4. Leads I and II are swapped, lead III is inverted, and aVL/aVF are exchanged Correct answer.

    Explanation

    Swapping the left arm and left leg exchanges the inputs to leads I and II, so those leads appear swapped. Lead III becomes inverted, and the augmented leads aVL and aVF also trade places.

  148. Question 148EKG Equipment, Lead Placement, and Tracing Acquisition

    A calibration pulse is 20 mm tall when the machine is set to 10 mm/mV. What voltage does this represent?

    1. 1 mV
    2. 0.5 mV
    3. 2 mV Correct answer.
    4. 20 mV

    Explanation

    At 10 mm/mV, every 10 mm of vertical deflection represents 1 mV. A 20-mm pulse therefore represents 2 mV.

  149. Question 149EKG Equipment, Lead Placement, and Tracing Acquisition

    What happens if the right leg electrode loses contact during a 12-lead EKG?

    1. Artifact may appear in multiple leads because the ground reference is lost Correct answer.
    2. The heart rate display will double
    3. Only lead V6 will show artifact
    4. The paper speed will change to 50 mm/s

    Explanation

    The right leg electrode serves as the neutral ground. If it loses contact, common-mode interference rejection worsens and artifact can affect several leads.

  150. Question 150EKG Equipment, Lead Placement, and Tracing Acquisition

    At 50 mm/s, one large box (5 mm) represents what duration?

    1. 0.50 second
    2. 0.04 second
    3. 0.10 second Correct answer.
    4. 0.20 second

    Explanation

    At 50 mm/s, the paper moves 50 mm each second, so 5 mm represents 0.10 second. This is half the duration of a large box at 25 mm/s.

  151. Question 151Rhythm Recognition, Interpretation, and Reporting

    Which rate range defines a normal sinus rhythm in a resting adult?

    1. 20 to 40 beats per minute
    2. 150 to 220 beats per minute
    3. 60 to 100 beats per minute Correct answer.
    4. 100 to 150 beats per minute

    Explanation

    Normal sinus rhythm originates in the SA node and discharges at 60 to 100 times per minute in a resting adult. Rates outside this range are described by modifiers such as bradycardia or tachycardia. The rhythm must also show upright P waves in lead II with one P wave per QRS.

  152. Question 152Rhythm Recognition, Interpretation, and Reporting

    A rhythm shows an upright P wave before every QRS, a PR interval of 0.16 second, and a ventricular rate of 48/min. This rhythm is best identified as:

    1. Sinus tachycardia
    2. Junctional rhythm
    3. Normal sinus rhythm
    4. Sinus bradycardia Correct answer.

    Explanation

    The rhythm is sinus in origin because each QRS is preceded by a consistent, upright P wave with a normal PR interval. The only abnormality is the rate, which falls below 60/min. A sinus rhythm slower than 60/min is termed sinus bradycardia.

  153. Question 153Rhythm Recognition, Interpretation, and Reporting

    When using the small-box method at standard paper speed, the ventricular rate is calculated by dividing 1500 by which value?

    1. the number of small boxes between two consecutive R waves Correct answer.
    2. the number of R waves in a 6-second strip and multiplying by 2
    3. the number of large boxes between two consecutive R waves
    4. the number of P waves in a 10-second strip

    Explanation

    At 25 mm/s each small box represents 0.04 second, so 1500 small boxes pass in one minute. Dividing 1500 by the number of small boxes between two R waves gives the rate in beats per minute. This method is most accurate for regular rhythms.

  154. Question 154Rhythm Recognition, Interpretation, and Reporting

    Which description best matches ventricular fibrillation?

    1. Regular narrow complexes at 180/min
    2. Sawtooth atrial waves with a regular ventricular response and narrow QRS
    3. Wide regular complexes at 30/min with visible P waves throughout the strip
    4. Chaotic undulations with no identifiable QRS complexes Correct answer.

    Explanation

    Ventricular fibrillation results from disorganized ventricular depolarization, producing a chaotic, irregular baseline without true QRS complexes. No effective cardiac output occurs, and it is a shockable pulseless arrest rhythm. Organized ventricular activity is absent by definition.

  155. Question 155Rhythm Recognition, Interpretation, and Reporting

    A tracing shows a flat line with no QRS complexes and only very low-amplitude undulations. This rhythm is:

    1. Asystole Correct answer.
    2. Agonal idioventricular rhythm
    3. Coarse ventricular fibrillation
    4. Sinus arrest with junctional escape

    Explanation

    Asystole is the absence of ventricular electrical activity, appearing as a flat or nearly flat line. Coarse fibrillatory waves are larger and chaotic rather than flat. Any organized QRS complexes, even slow ones, rule out asystole.

  156. Question 156Rhythm Recognition, Interpretation, and Reporting

    Which set of features identifies a premature ventricular complex?

    1. Narrow QRS with a rate above 150/min and no visible P waves
    2. Wide QRS preceded by a normal P wave with a shortening PR interval
    3. Narrow QRS preceded by an early P wave and a noncompensatory pause
    4. Wide, bizarre QRS with no preceding P wave and a compensatory pause Correct answer.

    Explanation

    A PVC arises from an ectopic ventricular focus, so depolarization spreads cell to cell and produces a wide, bizarre QRS without a preceding P wave. The pause that follows is usually fully compensatory because the SA node is not reset. A narrow early beat with a P wave indicates atrial origin instead.

  157. Question 157Rhythm Recognition, Interpretation, and Reporting

    At the standard EKG paper speed, one small box represents how much time?

    1. 0.20 second
    2. 0.12 second
    3. 0.04 second Correct answer.
    4. 0.4 second

    Explanation

    Standard paper speed is 25 mm/s, so each 1 mm small box equals 0.04 second. Five small boxes make one large box, which equals 0.20 second. These intervals are the basis for measuring PR, QRS, and QT durations.

  158. Question 158Rhythm Recognition, Interpretation, and Reporting

    Sinus tachycardia in an adult is characterized by which finding?

    1. A rate above 100/min with one upright P wave per QRS Correct answer.
    2. An irregularly irregular rate with absent P waves
    3. A rate of 40 to 60/min with inverted P waves in lead II
    4. A rate below 60/min with a normal P-wave axis

    Explanation

    Sinus tachycardia is a sinus rhythm discharging faster than 100/min, so every QRS is preceded by a normal upright P wave. The rhythm remains regular and the PR interval is usually normal. It is a physiologic response to fever, pain, anxiety, hypovolemia, or other stress.

  159. Question 159Rhythm Recognition, Interpretation, and Reporting

    An irregularly irregular rhythm with no discernible P waves and a ventricular rate of 130/min is most consistent with:

    1. Atrial fibrillation Correct answer.
    2. Multifocal atrial tachycardia
    3. Sinus tachycardia with frequent PACs
    4. Atrial flutter with 2:1 conduction

    Explanation

    Atrial fibrillation produces chaotic atrial activity, so no organized P waves are seen and the ventricular response is irregularly irregular. The rate depends on AV node conduction and may be fast, controlled, or slow. The absence of P waves distinguishes it from multifocal atrial tachycardia.

  160. Question 160Rhythm Recognition, Interpretation, and Reporting

    Which feature is characteristic of atrial flutter?

    1. P waves of at least three different shapes with an irregular ventricular response
    2. Absent atrial activity with a regular junctional escape rhythm
    3. Fine, chaotic baseline activity between QRS complexes
    4. Sawtooth flutter waves at an atrial rate of about 250 to 350/min Correct answer.

    Explanation

    Atrial flutter is a macroreentrant atrial rhythm producing continuous sawtooth waves at roughly 250 to 350/min. The AV node conducts only some of these impulses, most commonly in a 2:1, 3:1, or 4:1 pattern. Sawtooth waves in the inferior leads are the classic marker.

  161. Question 161Rhythm Recognition, Interpretation, and Reporting

    A rhythm shows a P wave before every QRS, a constant PR interval of 0.28 second, and a rate of 72/min. This is:

    1. First-degree AV block Correct answer.
    2. Second-degree AV block, type I
    3. Normal sinus rhythm
    4. Second-degree AV block, type II

    Explanation

    Every P wave is conducted, so no beats are dropped, which excludes second-degree block. The only abnormality is a PR interval exceeding 0.20 second, which defines first-degree AV block. The rhythm itself remains regular sinus.

  162. Question 162Rhythm Recognition, Interpretation, and Reporting

    Progressive lengthening of the PR interval until a P wave is not followed by a QRS, followed by a reset of the PR interval, describes which block?

    1. Second-degree AV block, type II
    2. Third-degree AV block
    3. First-degree AV block
    4. Second-degree AV block, type I Correct answer.

    Explanation

    Wenckebach (type I) second-degree block shows gradual PR prolongation as conduction through the AV node fatigues, ending in a dropped QRS. The cycle then resets and repeats, often with group beating. First-degree block never drops beats and type II block has a constant PR.

  163. Question 163Rhythm Recognition, Interpretation, and Reporting

    A rhythm has a constant PR interval of 0.18 second, with every third P wave not followed by a QRS complex. Which interpretation is correct?

    1. First-degree AV block with premature atrial complexes
    2. Second-degree AV block, type II Correct answer.
    3. Second-degree AV block, type I
    4. Third-degree AV block

    Explanation

    A dropped QRS with a constant PR interval in the conducted beats defines type II second-degree AV block. The conduction failure occurs below the AV node, so the PR does not progressively lengthen. This pattern carries a higher risk of progressing to complete heart block.

  164. Question 164Rhythm Recognition, Interpretation, and Reporting

    Which set of findings best describes a junctional escape rhythm?

    1. Flutter waves with a 4:1 ventricular response
    2. Upright P waves in lead II with a rate of 110/min and a normal PR interval
    3. Absent or inverted P waves with a narrow QRS and a rate of 40 to 60/min Correct answer.
    4. Wide QRS at 25/min with no atrial activity

    Explanation

    A junctional escape rhythm arises in the AV junction when the SA node fails, so the impulse travels retrogradely to the atria and anterogradely to the ventricles. P waves may be absent, inverted, or follow the QRS, and the QRS is typically narrow. The intrinsic junctional rate is 40 to 60/min.

  165. Question 165Rhythm Recognition, Interpretation, and Reporting

    A strip shows a normal sinus beat followed by a wide, bizarre beat, repeating in a 1:1 pattern. This pattern is:

    1. Ventricular bigeminy Correct answer.
    2. Ventricular couplet
    3. Ventricular tachycardia
    4. Ventricular trigeminy

    Explanation

    Bigeminy means every other beat is ectopic, producing a repeating one normal to one PVC pattern. A couplet is two consecutive PVCs without an intervening normal beat. Trigeminy describes every third beat being ectopic.

  166. Question 166Rhythm Recognition, Interpretation, and Reporting

    Supraventricular tachycardia typically presents with which findings?

    1. Sawtooth waves at 300/min with a 3:1 ventricular response
    2. Irregular rhythm with a fibrillatory baseline
    3. Narrow QRS at 150 to 250/min, often with hidden P waves Correct answer.
    4. Wide QRS at 120/min with AV dissociation

    Explanation

    SVT originates above the ventricles, so the QRS is narrow unless aberrant conduction is present. Rates commonly fall between 150 and 250/min, and P waves are frequently buried in the preceding T wave. The rhythm is usually remarkably regular.

  167. Question 167Rhythm Recognition, Interpretation, and Reporting

    A beat occurs early, has a narrow QRS, and is preceded by a P wave whose shape differs from the sinus P waves. This beat is a:

    1. Premature ventricular complex
    2. Premature atrial complex Correct answer.
    3. Ventricular escape beat
    4. Junctional escape beat

    Explanation

    An ectopic focus in the atria fires early, producing a premature P wave of different morphology that conducts normally, giving a narrow QRS. The pause afterward is usually noncompensatory because the SA node is reset. Wide QRS without a P wave would indicate ventricular origin.

  168. Question 168Rhythm Recognition, Interpretation, and Reporting

    A tracing shows regular, high-frequency spiked deflections that appear in all leads while the underlying rhythm stays regular and the patient is awake and talking. The most appropriate action is to:

    1. Begin CPR and call a code while preparing to intubate
    2. Check lead placement and reduce patient movement Correct answer.
    3. Administer atropine 1 mg for symptomatic bradycardia
    4. Defibrillate the patient immediately at 200 joules

    Explanation

    Artifact from muscle tremor or a loose electrode can mimic a dangerous rhythm, but the presence of an organized underlying rhythm and a conversant patient confirms a technical problem. The technologist should verify electrode contact, check cable connections, and minimize movement. Treatment decisions follow the patient's clinical status, not a distorted tracing.

  169. Question 169Rhythm Recognition, Interpretation, and Reporting

    A QRS complex measuring 0.14 second should be interpreted as:

    1. Prolonged, suggesting aberrant ventricular conduction Correct answer.
    2. Uninterpretable because of baseline artifact
    3. Within normal limits for an adult at rest
    4. Normal, since QRS duration varies widely with heart rate and age

    Explanation

    A normal QRS is less than 0.12 second because ventricular depolarization through the His-Purkinje system is rapid. A duration of 0.12 second or more indicates delayed ventricular activation from a bundle branch block, aberrancy, or a ventricular origin. Duration does not normally fluctuate enough with rate to account for this measurement.

  170. Question 170Rhythm Recognition, Interpretation, and Reporting

    A 6-second strip contains 9 QRS complexes. What is the approximate ventricular rate?

    1. 90/min Correct answer.
    2. 54/min
    3. 72/min
    4. 36/min

    Explanation

    The 6-second method multiplies the number of QRS complexes in the strip by 10 to estimate the rate for one minute. Nine complexes multiplied by 10 equals approximately 90/min. This method is useful for irregular rhythms where R-R intervals vary.

  171. Question 171Rhythm Recognition, Interpretation, and Reporting

    An EKG shows a ventricular rate of 38/min with wide QRS complexes while P waves march through at 90/min with no consistent PR interval. This is:

    1. Third-degree AV block Correct answer.
    2. Second-degree AV block, type II
    3. Accelerated idioventricular rhythm
    4. Sinus bradycardia with first-degree AV block

    Explanation

    Complete AV block produces independent atrial and ventricular rhythms, so the PR interval is random and the ventricular rate is slower than the atrial rate. A wide QRS at about 38/min indicates a ventricular escape focus. The absence of any relationship between P waves and QRS complexes is the key finding.

  172. Question 172Rhythm Recognition, Interpretation, and Reporting

    A polymorphic ventricular rhythm whose QRS complexes twist around the isoelectric baseline in a patient with a prolonged QT interval is:

    1. Torsades de pointes Correct answer.
    2. Atrial flutter with aberrant conduction
    3. Monomorphic ventricular tachycardia
    4. Ventricular fibrillation

    Explanation

    Torsades de pointes is a polymorphic ventricular tachycardia characterized by shifting QRS axis and a prolonged QT interval. It can degenerate into ventricular fibrillation and is often treated with magnesium and correction of the underlying cause. Monomorphic VT has a constant QRS shape.

  173. Question 173Rhythm Recognition, Interpretation, and Reporting

    A paced rhythm shows regular pacing spikes, but some spikes are not followed by a QRS complex. This finding represents:

    1. Oversensing of intrinsic beats
    2. Failure to capture Correct answer.
    3. Failure to pace (output failure)
    4. Failure to sense

    Explanation

    Failure to capture means the pacing stimulus is delivered but the myocardium does not depolarize, so no QRS follows the spike. It may result from lead displacement, insufficient output, or poor myocardial excitability. Failure to pace produces no spike at all.

  174. Question 174Rhythm Recognition, Interpretation, and Reporting

    After a long sinus pause, a wide QRS rhythm at 32/min appears. This is best described as:

    1. Ventricular escape rhythm Correct answer.
    2. Complete heart block with a junctional escape
    3. Accelerated idioventricular rhythm
    4. Junctional escape rhythm

    Explanation

    When higher pacemakers fail, a ventricular focus can rescue the heart at its intrinsic rate of 20 to 40/min, producing wide QRS complexes. The slow rate and wide morphology identify a ventricular rather than junctional escape. Junctional escape is faster and narrow, and accelerated idioventricular rhythm is faster than 40/min.

  175. Question 175Rhythm Recognition, Interpretation, and Reporting

    A premature ventricular complex that falls on the T wave of the preceding beat (R-on-T) is clinically important mainly because it:

    1. It may precipitate ventricular tachycardia or fibrillation Correct answer.
    2. It indicates that the atria are fibrillating abnormally
    3. It confirms a diagnosis of first-degree AV block
    4. It shows that a pacemaker has failed to capture

    Explanation

    The T wave represents the relative refractory period of ventricular repolarization. An ectopic impulse delivered during this vulnerable window can initiate ventricular tachycardia or fibrillation. This is why R-on-T PVCs are reported promptly to the care team.

  176. Question 176Rhythm Recognition, Interpretation, and Reporting

    What is the normal duration of the PR interval in an adult?

    1. 0.12 to 0.20 second Correct answer.
    2. 0.04 to 0.10 second
    3. 0.20 to 0.28 second
    4. 0.28 to 0.36 second

    Explanation

    The PR interval is measured from the start of the P wave to the start of the QRS complex, and it normally lasts 0.12 to 0.20 second (three to five small boxes). This interval reflects atrial depolarization plus conduction delay through the AV node.

  177. Question 177Rhythm Recognition, Interpretation, and Reporting

    Which lead is most commonly used for continuous rhythm monitoring because it usually displays upright, clearly visible P waves?

    1. aVR
    2. aVL
    3. V6
    4. Lead II Correct answer.

    Explanation

    Lead II lies nearly parallel to the heart's mean electrical axis, so atrial depolarization normally produces a prominent upright P wave in this lead. That is why lead II is the standard choice for rhythm strips and continuous monitoring.

  178. Question 178Rhythm Recognition, Interpretation, and Reporting

    The R-R interval on a regular rhythm measures 4 large boxes. Using the 300 method, what is the ventricular rate?

    1. 75/min Correct answer.
    2. 60/min
    3. 100/min
    4. 150/min

    Explanation

    In the 300 method, 300 is divided by the number of large boxes between two consecutive R waves. With 4 large boxes separating the R waves, 300 divided by 4 equals 75/min.

  179. Question 179Rhythm Recognition, Interpretation, and Reporting

    Which description is characteristic of ventricular fibrillation?

    1. Chaotic, irregular undulations with no identifiable QRS complexes Correct answer.
    2. A narrow-complex rhythm at about 150/min with no visible P waves
    3. A slow, wide-complex rhythm at about 30/min without P waves
    4. Regular sawtooth atrial waves at about 300/min

    Explanation

    Ventricular fibrillation produces disorganized, rapid electrical activity in the ventricles, so the tracing shows irregular, continuously changing waves with no true QRS complexes and no measurable rate. It is a pulseless emergency rhythm requiring immediate defibrillation.

  180. Question 180Rhythm Recognition, Interpretation, and Reporting

    A monitor shows an apparent flat line in lead II. What is the most appropriate action before documenting the rhythm as asystole?

    1. Increase the paper speed to 50 mm/s and print another strip
    2. Confirm the tracing in a second lead and check electrode and cable connections Correct answer.
    3. Record the rhythm as ventricular fibrillation
    4. Document the finding as artifact and continue routine monitoring

    Explanation

    True asystole must be confirmed in more than one lead while the patient is assessed, because a disconnected lead, loose electrode, or low gain can mimic a flat line. Verifying the tracing in a second lead and checking the cables prevents a false report of asystole.

  181. Question 181Rhythm Recognition, Interpretation, and Reporting

    The QT interval represents which electrical event?

    1. Ventricular repolarization alone
    2. Atrial depolarization
    3. Conduction time through the AV node
    4. Total ventricular depolarization and repolarization Correct answer.

    Explanation

    The QT interval extends from the beginning of the QRS complex to the end of the T wave, so it covers both ventricular depolarization and ventricular repolarization. Because it varies with heart rate, it is usually corrected to a QTc value.

  182. Question 182Rhythm Recognition, Interpretation, and Reporting

    Which waveform on the EKG represents ventricular repolarization?

    1. Atrial repolarization wave
    2. T wave Correct answer.
    3. QRS complex
    4. PR segment

    Explanation

    The T wave is produced as the ventricular muscle fibers repolarize and recover their resting electrical state. Changes in T wave shape, such as inversion or peaking, can signal ischemia or electrolyte imbalance.

  183. Question 183Rhythm Recognition, Interpretation, and Reporting

    Using the 1500 method, what is the ventricular rate when 22 small boxes separate two consecutive R waves?

    1. 94/min
    2. 68/min Correct answer.
    3. 55/min
    4. 75/min

    Explanation

    The 1500 method divides 1500 by the number of small boxes between consecutive R waves. Dividing 1500 by 22 gives approximately 68/min.

  184. Question 184Rhythm Recognition, Interpretation, and Reporting

    An irregular rhythm at 78/min shows P waves that change shape from beat to beat, with at least three different P wave morphologies. What is this rhythm?

    1. Sinus arrhythmia
    2. Atrial flutter with variable block
    3. Multifocal atrial tachycardia
    4. Wandering atrial pacemaker Correct answer.

    Explanation

    Wandering atrial pacemaker is defined by shifting pacemaker sites within the atria, producing at least three different P wave shapes with an irregular rhythm at a rate under 100/min. When the same pattern occurs at a rate above 100/min, it is called multifocal atrial tachycardia.

  185. Question 185Rhythm Recognition, Interpretation, and Reporting

    Which finding separates multifocal atrial tachycardia from wandering atrial pacemaker?

    1. Irregular R-R intervals
    2. Presence of wide QRS complexes
    3. Absence of visible P waves
    4. A ventricular rate greater than 100/min Correct answer.

    Explanation

    Both rhythms show at least three different P wave morphologies and irregular R-R intervals, so the distinguishing feature is rate. A rate above 100/min classifies the rhythm as multifocal atrial tachycardia, while a rate below 100/min is wandering atrial pacemaker.

  186. Question 186Rhythm Recognition, Interpretation, and Reporting

    Two wide, bizarre QRS complexes occur back to back with no normal beat between them and no preceding P waves. What is this called?

    1. Ventricular bigeminy
    2. Ventricular trigeminy
    3. Ventricular couplet Correct answer.
    4. Ventricular escape rhythm

    Explanation

    A ventricular couplet is two consecutive premature ventricular complexes occurring without an intervening sinus beat. Couplets are more clinically significant than isolated PVCs because they suggest a higher level of ventricular irritability.

  187. Question 187Rhythm Recognition, Interpretation, and Reporting

    Three or more consecutive ventricular ectopic beats occurring at a rate greater than 100/min define which rhythm?

    1. Idioventricular rhythm
    2. Ventricular tachycardia Correct answer.
    3. Accelerated idioventricular rhythm
    4. Ventricular escape rhythm

    Explanation

    Ventricular tachycardia is defined by three or more consecutive ventricular beats at a rate above 100/min, usually with wide QRS complexes and no consistent relationship to P waves. It is a potentially unstable rhythm that requires prompt evaluation.

  188. Question 188Rhythm Recognition, Interpretation, and Reporting

    A wide-complex rhythm at 78/min with no visible P waves appears after a period of sinus bradycardia. Which interpretation fits this tracing?

    1. Junctional rhythm with aberrant conduction
    2. Third-degree AV block
    3. Accelerated idioventricular rhythm Correct answer.
    4. Ventricular tachycardia

    Explanation

    A ventricular origin rhythm with wide QRS complexes and a rate between about 40 and 100/min is an accelerated idioventricular rhythm. It commonly appears after reperfusion or during recovery from bradycardia and is usually hemodynamically tolerated.

  189. Question 189Rhythm Recognition, Interpretation, and Reporting

    P waves appear regularly at 80/min, but no QRS complex follows any of them. Which term describes this rhythm?

    1. Third-degree AV block
    2. Asystole
    3. Ventricular standstill Correct answer.
    4. Fine ventricular fibrillation

    Explanation

    Ventricular standstill occurs when the atria continue to generate P waves but no ventricular activity follows, so no QRS complexes are produced. It represents complete failure of the ventricles to respond and is a pulseless emergency.

  190. Question 190Rhythm Recognition, Interpretation, and Reporting

    In an otherwise regular sinus rhythm, a pause occurs that equals exactly twice the normal P-P interval. This finding is most consistent with which rhythm disturbance?

    1. Sinus arrest
    2. Sinoatrial exit block Correct answer.
    3. Premature atrial complex
    4. Sinus arrhythmia

    Explanation

    In sinoatrial exit block, the sinus node fires but the impulse fails to leave the node, so the pause is an exact multiple of the normal P-P interval. Sinus arrest, by contrast, produces a pause that is not a clean multiple of the basic cycle.

  191. Question 191Rhythm Recognition, Interpretation, and Reporting

    A QRS complex appears earlier than expected, has a shape between that of the sinus beats and a known PVC, and is preceded by a sinus P wave. This beat is best identified as which type?

    1. Premature atrial complex with aberrancy
    2. Fusion beat Correct answer.
    3. Interpolated premature ventricular complex
    4. Ventricular escape beat

    Explanation

    A fusion beat results when a supraventricular impulse and a ventricular ectopic impulse activate the ventricles at nearly the same moment. The resulting QRS is a hybrid of the two morphologies and is typically preceded by a sinus P wave.

  192. Question 192Rhythm Recognition, Interpretation, and Reporting

    A premature wide QRS complex is preceded by an early P wave of different shape, and the QRS resembles a right bundle branch block pattern. How should this beat be interpreted?

    1. Ventricular escape beat
    2. Premature atrial complex conducted with aberrancy Correct answer.
    3. Paced beat
    4. Premature ventricular complex

    Explanation

    The early, abnormally shaped P wave shows that the impulse originated above the ventricles, and the wide QRS results from one bundle branch still being refractory when the impulse arrives. This produces an aberrantly conducted premature atrial complex that can mimic a PVC.

  193. Question 193Rhythm Recognition, Interpretation, and Reporting

    A demand pacemaker is set at 60/min, but when the patient's intrinsic rate falls to 45/min no pacing spikes appear on the tracing. Which malfunction does this represent?

    1. Failure to pace (failure to fire) Correct answer.
    2. Failure to capture
    3. Failure to sense
    4. Pacemaker-mediated tachycardia

    Explanation

    Failure to pace means the generator does not deliver an electrical stimulus when the intrinsic rate falls below the programmed rate. It differs from failure to capture, in which a pacing spike is present but no QRS follows it.

  194. Question 194Rhythm Recognition, Interpretation, and Reporting

    A tracing shows a PR interval of 0.10 second, a slurred upstroke of the QRS, and QRS duration of 0.14 second. These findings indicate which pattern?

    1. Left bundle branch block
    2. First-degree AV block
    3. Junctional rhythm
    4. Wolff-Parkinson-White pattern Correct answer.

    Explanation

    A short PR interval combined with a slurred initial QRS upstroke (delta wave) and wide QRS is the hallmark of the Wolff-Parkinson-White pattern. It occurs when an accessory pathway bypasses the AV node and pre-excites part of the ventricle.

  195. Question 195Rhythm Recognition, Interpretation, and Reporting

    During a routine 12-lead EKG, the patient's rhythm changes to a wide-complex tachycardia at 180/min and the patient reports chest pain. What should the technician do first?

    1. Finish acquiring the remaining leads before disturbing the patient
    2. Complete the tracing and note the change for the next shift
    3. Allow the patient to rest and repeat the EKG in 15 minutes
    4. Stop and immediately notify the supervising clinician Correct answer.

    Explanation

    A new, fast wide-complex rhythm accompanied by chest pain indicates a potentially life-threatening event that requires immediate clinical attention. The technician should stop the procedure and alert the supervising clinician without delay.

  196. Question 196Rhythm Recognition, Interpretation, and Reporting

    A tracing shows two P waves for every QRS complex, and the PR interval of the conducted beats is constant at 0.16 second. Which statement about this rhythm is correct?

    1. It may be either Mobitz I or Mobitz II, so a longer strip is needed to distinguish them Correct answer.
    2. It is complete AV block because not every P wave conducts
    3. It is first-degree AV block with blocked premature atrial complexes
    4. It is Mobitz II because the PR interval of the conducted beats is constant

    Explanation

    With 2:1 AV block there are never two consecutive conducted beats, so the PR interval cannot be observed to lengthen or stay fixed across successive beats. Type I and type II therefore cannot be separated from a 2:1 strip alone, and a longer recording is needed.

  197. Question 197Rhythm Recognition, Interpretation, and Reporting

    Which finding on a wide-complex tachycardia most strongly supports ventricular tachycardia rather than supraventricular tachycardia with aberrancy?

    1. A QRS duration of 0.14 second
    2. Presence of capture and fusion beats Correct answer.
    3. A ventricular rate of 165/min
    4. Perfectly regular R-R intervals

    Explanation

    Capture beats and fusion beats occur only when the atria and ventricles are activating independently, which is a hallmark of ventricular tachycardia. Their presence is strong evidence against a supraventricular origin with aberrant conduction.

  198. Question 198Rhythm Recognition, Interpretation, and Reporting

    A patient's QT interval measures 0.36 second and the heart rate is 100/min (R-R interval 0.60 second). Using Bazett's formula (QTc = QT divided by the square root of the R-R interval), what is the QTc?

    1. 0.46 second Correct answer.
    2. 0.40 second
    3. 0.36 second
    4. 0.58 second

    Explanation

    Bazett's formula divides the measured QT by the square root of the R-R interval in seconds. The square root of 0.60 is about 0.775, and 0.36 divided by 0.775 is approximately 0.46 second, which is a prolonged QTc.

  199. Question 199Rhythm Recognition, Interpretation, and Reporting

    A dying patient's tracing shows very slow, wide, irregular complexes at about 12/min with no P waves and a continuously changing morphology. How should this rhythm be described?

    1. Ventricular escape rhythm
    2. Agonal rhythm Correct answer.
    3. Ventricular fibrillation
    4. Idioventricular rhythm

    Explanation

    An agonal rhythm is a terminal rhythm with extremely slow, irregular, wide complexes that lack organized atrial activity and carry a very poor prognosis. It reflects dying myocardium rather than a stable escape mechanism.

  200. Question 200Rhythm Recognition, Interpretation, and Reporting

    In a patient with atrial fibrillation and no known bundle branch block, a wide QRS complex follows a short R-R interval that itself came after a long R-R interval. What does this most likely represent?

    1. Ventricular tachycardia
    2. A paced ventricular beat
    3. A premature ventricular complex
    4. Ashman phenomenon with aberrant ventricular conduction Correct answer.

    Explanation

    Ashman phenomenon is aberrant conduction, most often with a right bundle branch block pattern, occurring when an early beat follows a long cycle. The long cycle prolongs refractoriness in the bundle branches, so the next early impulse conducts aberrantly.

NHA EKG Technician flashcards

32 cards. Read the term and the definition here. The deck at the top of this page is optional.

Soap and water hand hygiene
Indicated when hands are visibly soiled and after contact with spore-forming organisms such as Clostridioides difficile, because alcohol-based rubs do not reliably kill spores.
Alcohol-based hand rub
Preferred for routine hand decontamination when hands are not visibly soiled; apply enough product to keep hands wet for at least 20 seconds, then rub until dry.
Two patient identifiers
Verify identity with two independent identifiers, such as full name plus date of birth or medical record number, before acquiring any EKG tracing.
Electrode site preparation
Clean skin with alcohol and let it dry, then abrade lightly if needed; removing oils and dead cells lowers impedance and reduces tracing artifact.
Clipping chest hair
Clip excessive chest hair with scissors or clippers instead of shaving, because shaving creates micro-abrasions that raise infection risk and impair electrode contact.
Equipment grounding
Use three-prong grounded plugs and avoid daisy-chained extension cords; proper grounding prevents macroshock and microshock hazards during EKG recording.
Somatic tremor artifact
High-frequency spiky baseline interference caused by shivering or voluntary muscle movement; warming the patient and supporting the limbs reduces it.
Standard precautions
Applied to every patient regardless of diagnosis; blood and all body fluids are treated as potentially infectious and gloves are worn when contact is likely.
Sinoatrial node firing rate
The primary pacemaker sits at the junction of the superior vena cava and right atrium and fires at an intrinsic rate of 60 to 100 beats per minute.
AV node escape rate
The secondary pacemaker has an intrinsic rate of 40 to 60 beats per minute and delays impulses about 0.1 second before ventricular activation.
Normal PR interval
Measured from the start of the P wave to the start of the QRS; normally 0.12 to 0.20 seconds, or three to five small boxes at 25 mm/s.
Normal QRS duration
Less than 0.12 seconds, or three small boxes; it represents ventricular depolarization and lengthens with bundle branch block or ventricular rhythms.
Bazett QT correction
QTc equals the measured QT interval divided by the square root of the RR interval in seconds, correcting the QT interval for heart rate.
P wave depolarization
Represents atrial depolarization initiated at the SA node; normally upright in lead II and inverted in lead aVR.
Normal electrical axis
Between -30 and +90 degrees; values outside this range indicate left or right axis deviation from conduction disease or chamber enlargement.
Coronary territory lead mapping
Right coronary ischemia appears in leads II, III and aVF; left anterior descending in V1-V4; circumflex in I, aVL, V5 and V6.
V1 electrode placement
Fourth intercostal space at the right sternal border; V2 is placed at the same level on the left sternal border.
V4 electrode placement
Fifth intercostal space at the midclavicular line; V3 is placed halfway between V2 and V4.
Limb lead color codes
In the United States: right arm white, left arm black, left leg red, right leg green; the right leg electrode acts as the ground.
Standard paper speed
At 25 mm/s one small box equals 0.04 second and one large box equals 0.20 second; 30 large boxes equal 6 seconds.
Standard calibration 10 mm/mV
A 1-millivolt signal produces 10 millimeters of deflection, or two large boxes; any change in gain must be noted on the tracing.
Arm lead reversal sign
Right arm and left arm reversal produces a negative P wave and negative QRS in lead I, with an upright P wave in aVR.
60-cycle interference
Thick fuzzy baseline caused by nearby electrical equipment; improving electrode contact, cable routing and grounding reduces this artifact.
Six-second strip method
Count the QRS complexes in a 6-second strip, then multiply by 10 to estimate the ventricular rate per minute.
Sinus rhythm criteria
Regular rhythm at 60 to 100 beats per minute, upright P wave in lead II before every QRS, and a PR interval of 0.12 to 0.20 seconds.
Atrial fibrillation hallmark
Irregularly irregular ventricular rhythm with no identifiable P waves; the baseline shows chaotic fibrillatory activity instead of discrete atrial deflections.
Atrial flutter waves
Sawtooth flutter waves with an atrial rate near 250 to 350 per minute; 2:1 AV conduction yields a ventricular rate near 150.
Premature ventricular complex
Wide bizarre QRS complex longer than 0.12 seconds with no preceding P wave, usually followed by a full compensatory pause.
Ventricular fibrillation
Chaotic undulating waveform with no discernible QRS complexes; the patient is pulseless and needs immediate CPR and defibrillation.
First-degree AV block
PR interval longer than 0.20 seconds that remains constant, with every P wave followed by a QRS complex.
Wenckebach block pattern
Second-degree type I AV block in which the PR interval progressively lengthens until one QRS complex is dropped, then the cycle resets.
STEMI elevation thresholds
New ST elevation of at least 1 mm in two contiguous limb leads, or at least 2 mm in V2-V3 in men and 1.5 mm in women.

NHA EKG Technician study guide

Patient Preparation, Safety, and Infection Control

Preparing the patient

Confirm identity with two identifiers (full name plus date of birth or medical record number) before you touch the patient or the machine. Explain the procedure in plain language, obtain consent per facility policy, provide privacy, and position the patient supine with arms at the sides and legs uncrossed. Expose only the chest area needed. Keep the room warm and the patient covered - shivering produces somatic tremor artifact that can mimic arrhythmia.

Skin preparation

Clean, dry, hair-free skin gives the cleanest tracing. Clip excessive hair rather than shaving (shaving can abrade skin and create irritation). Cleanse with soap and water or alcohol and allow it to dry completely before applying electrodes; gently abrade oily skin with gauze. Lotions, powders, and sweat raise impedance and cause baseline wander and 60-cycle interference.

Electrical and physical safety

Use a properly grounded machine and a hospital-grade outlet; inspect cords and clips for damage and report defects. Never touch the patient during defibrillation or cardioversion, and follow policy about disconnecting leads. Raise and lock the bed, keep the floor dry, and route cables so they are not a trip hazard.

Infection control

Perform hand hygiene before and after every patient contact. Follow standard precautions: gloves whenever contact with blood, body fluids, non-intact skin, or contaminated equipment is possible. Disinfect reusable electrodes and cables between patients; single-use electrodes are never reused.

Traps

Questions test clip-versus-shave, alcohol drying time, and whether the technologist may interpret the tracing (technicians report, they do not diagnose). Also expect mastectomy or amputation items - adjust placement and document.

Rule of thumb: two identifiers, warm room, dry skin, clean hands.

Cardiovascular Anatomy, Physiology, and Electrophysiology

Anatomy and circulation

Four chambers and four valves move blood in one direction: superior and inferior vena cava to right atrium, tricuspid valve to right ventricle, pulmonary valve to the lungs, pulmonary veins to left atrium, mitral valve to left ventricle, aortic valve to the aorta. The right heart handles deoxygenated blood; the left heart pumps oxygenated blood systemically. Coronary supply: the right coronary artery feeds the right atrium, right ventricle, and inferior wall and often the SA or AV node; the left main divides into the LAD (anterior wall and septum) and circumflex (lateral wall). These territories explain which leads show ST changes.

Conduction system

SA node (intrinsic 60-100 bpm) fires first and dominates, traveling through internodal tracts to the AV node (40-60 bpm), which delays the impulse about 0.1 second so the atria can empty. Then bundle of His, right and left bundle branches, and Purkinje fibers (20-40 bpm). The fastest pacemaker controls the heart.

Cellular electrophysiology

Resting cells are negative inside (about -90 mV). Depolarization is sodium influx (fast fibers) or calcium influx (slow SA/AV nodal fibers); repolarization is potassium efflux, with the sodium-potassium pump restoring gradients. On the tracing: P wave = atrial depolarization; QRS = ventricular depolarization (atrial repolarization is buried inside it); T wave = ventricular repolarization. The PR segment reflects AV nodal delay; an isoelectric ST segment reflects the plateau phase.

Physiology and electrolytes

Cardiac output = heart rate × stroke volume. Sympathetic stimulation raises rate, contractility, and conduction velocity; vagal tone slows the SA and AV nodes. Hyperkalemia peaks T waves, hypokalemia flattens T waves and produces U waves, and hypocalcemia prolongs the QT interval.

Traps

Calling the T wave "depolarization," naming the AV node as the primary pacemaker, and confusing pulmonary artery with pulmonary vein are classic distractors.

Rule of thumb: 60-100, 40-60, 20-40 - SA, AV, Purkinje.

EKG Equipment, Lead Placement, and Tracing Acquisition

Machine settings

Standard 12-lead EKGs run at 25 mm/s paper speed and 10 mm/mV gain; the standardization mark at the start of each row is 10 mm tall and 2 mm wide (0.2 s). Verify calibration before you measure intervals - changing gain alters amplitude but not duration.

Limb and augmented leads

Electrodes go on the right arm (RA), left arm (LA), left leg (LL), and right leg (RL, used as ground). Lead I compares LA to RA, lead II compares LL to RA, and lead III compares LL to LA. The augmented leads aVR, aVL, and aVF view the same vectors from different angles.

Precordial placement

The six chest leads follow a predictable march: V1 at the 4th intercostal space, right sternal border; V2 at the 4th intercostal space, left sternal border; V3 halfway between V2 and V4; V4 at the 5th intercostal space, midclavicular line; V5 at the 5th intercostal space, anterior axillary line; V6 at the 5th intercostal space, midaxillary line. Place electrodes on bare skin, avoiding bone, dense muscle, and breast tissue; clip hair as needed.

Acquisition

Ask the patient to lie still, breathe normally, and avoid talking during the recording. Acquire all leads, check each for artifact and loose electrodes, and repeat the tracing if quality is poor. Label the tracing, document symptoms and events, and keep the patient in view.

Traps

Placing V1 and V2 too high is the most common error and can mimic or hide infarction. Reversing RA and LA inverts lead I and swaps aVR and aVL, giving a negative P and QRS in lead I. Electrode colors differ between AHA and IEC conventions, so identify leads by name under facility policy rather than color alone.

Rule of thumb: 4th intercostal space for V1-V2, 5th for V4-V6 - walk down and around the chest.

Rhythm Recognition, Interpretation, and Reporting

Systematic approach

Read every tracing the same way: rate, regularity, P waves, PR interval, QRS width, then ST-T changes and comparison with prior EKGs. Rate by the large-box method (300 divided by large boxes between R waves gives 300, 150, 100, 75, 60, 50, 43) or by 1500 divided by small boxes. For irregular rhythms, count QRS complexes in a 6-second strip and multiply by 10. Normal PR is 0.12-0.20 s (3-5 small boxes); normal QRS is under 0.12 s (3 small boxes).

Common rhythms

Sinus rhythm requires an upright P in lead II, one P per QRS, and a rate of 60-100. Sinus bradycardia is under 60, sinus tachycardia over 100. Atrial fibrillation is irregularly irregular with no discernible P waves; atrial flutter shows sawtooth flutter waves. PVCs are wide, bizarre, premature, and lack a preceding P wave, usually followed by a compensatory pause. SVT is narrow, fast, and regular; ventricular fibrillation is chaotic; asystole is a flat line. Blocks: first degree has a prolonged PR; Mobitz I shows progressive PR lengthening before a dropped QRS; Mobitz II shows a constant PR with dropped QRS complexes; third degree shows AV dissociation with an escape rhythm.

Ischemia and infarction

ST elevation in contiguous leads suggests injury, often with reciprocal depression elsewhere; ST depression and T-wave inversion suggest ischemia; Q waves suggest older infarction. Territory groups: inferior II, III, aVF; anterior V1-V4; lateral I, aVL, V5-V6.

Reporting

Technicians do not diagnose. Recognize critical findings - rate below 40 or above 150, chest pain with ST elevation, ventricular fibrillation, asystole - notify the responsible provider per policy, document the notification, and stay with the patient.

Traps

The 300 method applied to an irregular rhythm, artifact mistaken for ventricular fibrillation, and PVCs mislabeled as heart block are frequent distractors.

Rule of thumb: rate, regularity, P, PR, QRS, ST-T - and always compare to the prior tracing.

NHA EKG Technician cheat sheet

Quick reference

Patient Preparation, Safety, and Infection Control

  • Standard precautions apply to every patient regardless of diagnosis: blood and all body fluids are treated as potentially infectious, and gloves are worn whenever contact with them is possible.

  • Hand hygiene decision rule: alcohol-based rub when hands are not visibly soiled; soap and water when visibly soiled and after care of patients with C. difficile or norovirus, because alcohol does not reliably kill spores.

  • Identify the patient with two independent identifiers (full name plus date of birth or medical record number) before applying electrodes or acquiring any tracing.

  • Skin preparation sequence: clean with alcohol, allow to dry fully, abrade lightly if impedance is high; oily, moist, or hairy skin raises impedance and increases artifact.

  • Excess chest hair is clipped with clippers or scissors per policy rather than shaved; shaving creates micro-abrasions that increase infection risk and degrade electrode contact.

  • Electrical safety rule: equipment must be grounded through a three-prong plug, extension cords are not daisy-chained, and cables are kept away from wet surfaces and heat sources.

  • Artifact control: keep the patient warm to prevent shivering, support the limbs, and instruct quiet normal breathing; somatic tremor produces high-frequency spiky baseline interference.

  • For a resting 12-lead EKG the patient lies supine with arms at the sides and legs uncrossed; exercise, smoking, and caffeine are avoided for roughly 30 minutes before the test per facility policy.

Quick reference

Cardiovascular Anatomy, Physiology, and Electrophysiology

  • Normal conduction sequence: SA node → atrial and internodal pathways → AV node (delay about 0.1 s) → bundle of His → right and left bundle branches → Purkinje fibers.

  • Intrinsic pacemaker rates: SA node 60-100 bpm, AV junction 40-60 bpm, ventricular Purkinje system 20-40 bpm; the fastest pacemaker normally dominates.

  • Normal intervals at 25 mm/s: PR 0.12-0.20 s (3-5 small boxes); QRS less than 0.12 s (under 3 small boxes); QT varies with rate and is corrected as QTc = QT ÷ √RR (Bazett).

  • Waveform meanings: P wave = atrial depolarization, QRS = ventricular depolarization, T wave = ventricular repolarization; atrial repolarization is hidden within the QRS.

  • A depolarization wave traveling toward a positive electrode produces an upward (positive) deflection; traveling away produces a downward deflection.

  • Normal frontal plane electrical axis is -30° to +90°; more negative indicates left axis deviation, more positive indicates right axis deviation.

  • Cardiac output = heart rate × stroke volume; normal adult resting output is about 4-8 L/min.

  • Ischemia territory by lead: right coronary artery → II, III, aVF; left anterior descending → V1-V4; circumflex → I, aVL, V5, V6.

Quick reference

EKG Equipment, Lead Placement, and Tracing Acquisition

  • Precordial placement: V1 = 4th intercostal space right sternal border; V2 = 4th ICS left sternal border; V3 = midway between V2 and V4; V4 = 5th ICS midclavicular line; V5 = anterior axillary line at V4 level; V6 = midaxillary line at V4 level.

  • US limb lead colors: right arm white, left arm black, left leg red, right leg green (ground); European coding differs and must be confirmed before use.

  • Paper speed 25 mm/s: 1 small box (1 mm) = 0.04 s; 1 large box (5 mm) = 0.20 s; 30 large boxes = 6 seconds.

  • Standard calibration is 10 mm/mV, so a 1 mV signal produces 10 mm (two large boxes) of deflection; any gain change (for example 20 mm/mV) must be documented on the tracing.

  • Right arm/left arm reversal produces a negative P wave and negative QRS in lead I with an upright aVR; arm/leg reversals produce other characteristic patterns that must be caught before reporting.

  • Artifact patterns: 60 Hz electrical interference = thick fuzzy baseline; baseline wander = slow sway from respiration or movement; somatic tremor = spiky irregular baseline.

  • A continuous artifact confined to one lead most often indicates a loose or dried electrode for that specific lead rather than a patient-wide problem.

  • Additional leads: right-sided V4R for suspected right ventricular infarction and posterior leads V7-V9 for suspected posterior myocardial infarction.

  • Each tracing is labeled with patient identifiers, date and time of acquisition, lead configuration or gain changes, and any symptoms present during recording.

Quick reference

Rhythm Recognition, Interpretation, and Reporting

  • Rate rules: 300 ÷ number of large boxes between R waves for regular rhythms; count QRS complexes in a 6-second strip × 10 for irregular rhythms.

  • Sinus rhythm criteria: rate 60-100, upright P in lead II before every QRS, PR 0.12-0.20 s, constant PP and RR intervals. Sinus bradycardia is under 60; sinus tachycardia is over 100.

  • Atrial fibrillation: irregularly irregular ventricular response, absent P waves, fibrillatory baseline. Atrial flutter: sawtooth waves at about 250-350/min, often 2:1 conduction giving a ventricular rate near 150.

  • AV block rule: first degree = PR over 0.20 s and constant; second degree type I = progressive PR lengthening until a QRS drops; type II = constant PR with sudden dropped QRS; third degree = complete AV dissociation.

  • PVC: wide QRS over 0.12 s, bizarre shape, no preceding P wave, usually a full compensatory pause; three or more consecutive PVCs at over 100 bpm define ventricular tachycardia.

  • Lethal rhythm responses: ventricular fibrillation (chaotic, no QRS) and pulseless ventricular tachycardia are shockable; asystole (flat line confirmed in two leads) is not shockable and is treated with CPR and epinephrine.

  • Acute injury markers: new ST elevation of at least 1 mm in two contiguous limb leads, or at least 2 mm in V2-V3 in men (1.5 mm in women), suggests STEMI; reciprocal depression supports the finding.

  • Torsades de pointes is polymorphic ventricular tachycardia with a twisting axis around the baseline and is associated with a prolonged QT interval.

  • Any critical finding is reported to the responsible provider immediately and the notification, time, and person contacted are documented.

NHA EKG Technician key terms

Standard precautions

Infection-control steps taken with every patient because any blood or body fluid may carry disease; includes hand hygiene, gloves and other barriers, clean equipment, and careful handling of sharps and spills.

Related: Hand hygiene, Personal protective equipment (PPE), Isolation precautions
Hand hygiene

Cleaning the hands with soap and water or an alcohol-based rub before and after patient contact and after removing gloves; the most effective single action for preventing infection spread in health care.

Related: Standard precautions, Personal protective equipment (PPE)
Personal protective equipment (PPE)

Barriers such as gloves, gown, mask, and eye protection worn to keep blood, body fluids, and droplets off the skin and mucous membranes; the items chosen depend on the task and the patient's precautions.

Related: Standard precautions, Isolation precautions
Isolation precautions

Extra transmission-based precautions, contact, droplet, or airborne, used for patients with known or suspected contagious illness; they may require a mask, gown, dedicated equipment, or a private room.

Related: Standard precautions, Personal protective equipment (PPE)
Two-identifier verification

Confirming who the patient is using two independent facts, typically full name and date of birth, before any procedure; required before placing leads or attaching a monitor to the wrong person.

Related: Informed consent
Informed consent

A patient's voluntary agreement to a procedure after being told what will be done, why, and what risks exist; the technician confirms consent was given and stays within their scope when answering questions.

Related: Two-identifier verification
Medical asepsis

Clean technique that reduces the number and spread of microorganisms, using disinfected equipment, clean gloves, and hand hygiene; it is not the same as surgical asepsis, which aims for sterility.

Related: Hand hygiene, Standard precautions
Syncope precautions

Steps that reduce the chance a patient will faint during a recording, such as having them lie down, staying at their side, and noticing pale skin, sweating, or complaints of dizziness early.

Related: Two-identifier verification
Sinoatrial (SA) node

The heart's natural pacemaker, a small group of cells in the upper right atrium that fires about 60 to 100 times a minute and normally starts the impulse for each heartbeat.

Related: Atrioventricular (AV) node, Automaticity
Atrioventricular (AV) node

A structure between the atria and ventricles that slows the electrical impulse briefly so the atria can empty before the ventricles contract, and that limits how many fast atrial impulses get through.

Related: Sinoatrial (SA) node, Purkinje fibers
Purkinje fibers

Specialized conducting fibers that carry the impulse quickly through the ventricular walls so the ventricles contract together, normally from the apex toward the base of the heart.

Related: Atrioventricular (AV) node, Depolarization
Depolarization

The electrical change in which a heart cell's inside becomes positive as ions cross its membrane; in the atria it produces the P wave, and in the ventricles it produces the QRS complex.

Related: Repolarization, Refractory period
Repolarization

The return of a heart cell's charge to its resting state after depolarization; ventricular repolarization appears on the EKG as the T wave and falls within the QT interval.

Related: Depolarization, QT interval
Automaticity

The ability of certain heart cells, especially those in the SA node and other pacemaker sites, to create an electrical impulse on their own without a signal from nerves.

Related: Sinoatrial (SA) node, Depolarization
Refractory period

The brief time after a heart cell fires when it cannot be excited again; this protects the heart from excessively rapid re-excitation and sets a limit on how fast a rhythm can go.

Related: Depolarization, Repolarization
Cardiac output

The amount of blood the heart pumps each minute, equal to heart rate multiplied by stroke volume; it shows whether the heart is delivering enough blood for the body's needs.

Coronary arteries

Vessels on the heart's outer surface that supply the heart muscle with oxygen and nutrients; when narrowed or blocked they cause ischemia, which shows up as ST-segment and T-wave changes.

Related: Depolarization, ST segment
Electrode

A conductive pad, usually adhesive and gel-backed, attached to the skin to pick up the heart's electrical signal and send it through a cable to the EKG machine.

Related: Lead, Skin preparation for electrodes
Lead

The view of the heart's electrical activity produced by a specific pair or combination of electrodes; a 12-lead EKG records twelve of these views at the same time.

Related: Electrode, 12-lead EKG
12-lead EKG

A recording made with ten electrodes that produces twelve different views of the heart, including six limb leads and six chest leads; used to look for rhythm problems, ischemia, and chamber enlargement.

Related: Lead, Precordial leads
Limb leads

Leads I, II, III, aVR, aVL, and aVF, which are derived from electrodes placed on the arms and legs and view the heart in the frontal plane.

Related: Lead, Precordial leads
Precordial leads

The six chest leads, V1 through V6, placed across the front of the chest; they view the heart in the horizontal plane and help detect changes in specific regions of the ventricles.

Related: Lead, Limb leads
Skin preparation for electrodes

Cleaning the electrode sites, clipping excess hair if needed, and lightly rubbing the skin to remove oils and dead cells so the pads stick well and artifact from poor contact is reduced.

Related: Electrode, Artifact
Artifact

Any signal on the tracing that does not come from the heart, such as movement, loose electrodes, or electrical interference; it can mimic or hide a real rhythm and should be corrected before interpreting.

Related: Somatic tremor, Wandering baseline
Somatic tremor

Jagged, irregular artifact caused by the patient's muscles trembling, shivering, or moving; it blurs the baseline and can imitate atrial fibrillation or fine ventricular activity.

Related: Artifact, Wandering baseline
Wandering baseline

A slow, drifting up-and-down movement of the tracing caused by poor electrode contact, sweating, breathing, or patient motion; it makes measuring amplitudes and ST segments unreliable.

Related: Artifact, Electrode
Standardization mark

The rectangular calibration mark placed at the start of a tracing; at standard settings it is 10 mm tall and shows that the machine is recording voltage and paper speed correctly.

Related: Paper speed, Artifact
Paper speed

How fast the recording paper moves, usually 25 mm per second; at that speed one small box equals 0.04 second and one large box equals 0.20 second, which is used for measuring intervals.

Related: Standardization mark, PR interval
P wave

The first small upward deflection of a normal complex, representing atrial depolarization; its presence, shape, and relation to the QRS help identify sinus rhythms and atrial enlargement.

Related: PR interval, Sinus rhythm
PR interval

The time from the start of the P wave to the start of the QRS complex, normally 0.12 to 0.20 second; a longer interval suggests a conduction delay between the atria and ventricles.

Related: P wave, QRS complex
QRS complex

The deflection representing ventricular depolarization, normally narrow and under 0.12 second; a wide QRS suggests the impulse is traveling through the ventricles abnormally or from a ventricular source.

Related: PR interval, QT interval
ST segment

The flat section between the end of the QRS complex and the start of the T wave; elevation or depression here can signal myocardial injury or ischemia and is a key finding to report.

Related: QT interval, Coronary arteries
QT interval

The time from the start of the QRS complex to the end of the T wave, covering ventricular depolarization and repolarization; it varies with heart rate, and a prolonged QT raises the risk of dangerous rhythms.

Related: QRS complex, Repolarization
Sinus rhythm

A normal rhythm that starts in the SA node, with a P wave before every QRS, a steady rate between 60 and 100, and consistent intervals; it is the reference pattern other rhythms are compared to.

Related: P wave, Sinus bradycardia
Sinus bradycardia

A sinus rhythm with a rate slower than 60 beats per minute; it may be normal in athletes or during sleep, but can also cause dizziness or low blood pressure and should be reported.

Related: Sinus rhythm, Sinus tachycardia
Sinus tachycardia

A sinus rhythm faster than 100 beats per minute, often caused by exercise, fever, pain, anxiety, or blood loss; P waves are present but may be hidden in the preceding T wave at very fast rates.

Related: Sinus rhythm, Sinus bradycardia
Atrial fibrillation

An irregular rhythm with no clear P waves, a wavy baseline, and an irregularly irregular ventricular rate; the atria quiver instead of contracting, so clots can form and the pulse must be checked carefully.

Related: P wave, Artifact
Premature ventricular contraction (PVC)

An early beat that starts in the ventricles, producing a wide, odd-looking QRS with no preceding P wave and usually a pause afterward; frequent or grouped PVCs are reported to the provider.

Related: QRS complex, Sinus rhythm
Asystole

A flat line with no electrical activity, meaning the heart is not generating any impulse; it is a cardiac arrest rhythm, so check leads and the patient, then call for emergency help immediately.

Related: Artifact

NHA EKG Technician study plan

8 weeks · About 7 hours per week

Week 1

Cardiovascular Anatomy, Physiology, and Electrophysiology

  • Label the four chambers, four valves, great vessels, and major coronary arteries on a blank heart diagram from memory

  • Trace the impulse pathway from the SA node through the internodal tracts, AV node, bundle of His, bundle branches, and Purkinje fibers

  • Explain how each phase of the cardiac cycle corresponds to electrical and mechanical events

  • Define depolarization and repolarization and state which ion movements drive each phase of the myocardial action potential

Your checkpoint

Hand-drawn conduction-system and cardiac-anatomy diagram with every structure labeled and a one-page written explanation of normal impulse timing, self-checked against course notes

Week 2

Cardiovascular Anatomy, Physiology, and Electrophysiology & EKG Equipment, Lead Placement, and Tracing Acquisition

  • Measure PR, QRS, and QT intervals on 10 practice strips using the small-box method and state the normal range for each

  • Calculate heart rate on 10 strips using both the 1500 method and the 6-second method

  • Identify the P wave, QRS complex, T wave, ST segment, and U wave and name the lead that best displays each

  • Set paper speed to 25 mm/s and standardization to 10 mm/mV and explain what each setting controls

Your checkpoint

Completed measurement worksheet covering 10 strips with rate, PR, QRS, and QT recorded for each, scoring at least 90% against an answer key

Week 3

EKG Equipment, Lead Placement, and Tracing Acquisition

  • Position the four limb leads and precordial leads V1 through V6 at the correct anatomical landmarks on a partner or manikin

  • Explain what view of the heart each precordial lead provides and why lead placement errors change the tracing

  • Perform proper skin preparation and electrode application to reduce artifact

  • Identify and correct somatic tremor, AC interference, baseline wander, and loose-electrode artifact on sample tracings

Your checkpoint

Full 12-lead setup performed on a partner or manikin within 5 minutes, verified against a step-by-step placement checklist by a peer or instructor

Week 4

EKG Equipment, Lead Placement, and Tracing Acquisition & Rhythm Recognition, Interpretation, and Reporting

  • Apply a five-step interpretation method (rate, regularity, P waves, PR interval, QRS width) to every strip encountered

  • Differentiate normal sinus rhythm, sinus bradycardia, and sinus tachycardia across 12 strips

  • Troubleshoot three technical problems that mimic arrhythmia: reversed arm leads, misplaced V1/V2, and a loose electrode

  • Document findings using a standardized rate, rhythm, and interval reporting format

Your checkpoint

Interpretation log of 15 strips worked with the five-step method, scoring at least 80% agreement with an answer key

Week 5

Rhythm Recognition, Interpretation, and Reporting

  • Identify atrial premature complexes, atrial flutter, atrial fibrillation, and supraventricular tachycardia and describe the defining strip features of each

  • Distinguish junctional rhythms from sinus rhythms using P-wave morphology, rate, and P-to-QRS relationship

  • Compare atrial rhythms by rate, regularity, and P-wave presentation in a structured comparison table

  • Write a complete report entry for each rhythm using the standard rate, rhythm, and interval format

Your checkpoint

Rhythm reference table covering 10 rhythms with rate, regularity, P-wave description, PR interval, and QRS width columns completed and self-checked

Week 6

Rhythm Recognition, Interpretation, and Reporting

  • Differentiate first-degree, second-degree type I, second-degree type II, and third-degree AV block by PR interval and dropped beats

  • Identify premature ventricular complexes, ventricular tachycardia, ventricular fibrillation, and idioventricular rhythm on strips

  • Recognize lethal rhythms that require immediate escalation and state the reporting action an EKG technician takes

  • Measure and record intervals on ventricular rhythms where measurement is possible

Your checkpoint

Twenty-strip quiz scored at 85% or higher, including five written escalation statements for lethal-rhythm findings

Week 7

Patient Preparation, Safety, and Infection Control & Rhythm Recognition, Interpretation, and Reporting

  • List the standard precautions and transmission-based precautions that apply during an EKG procedure

  • Describe cleaning and disinfection steps for the machine, cables, and reusable electrodes between patients

  • Identify the patient-identification, privacy, and consent steps completed before recording a tracing

  • Describe technique modifications for pediatric, older adult, and mobility-impaired patients

  • Re-interpret ten strips missed on earlier quizzes and write the correct rationale for each

Your checkpoint

Patient-safety and infection-control checklist plus a remediation log of ten previously missed strips with corrected interpretations

Week 8

Patient Preparation, Safety, and Infection Control & Cardiovascular Anatomy, Physiology, and Electrophysiology & EKG Equipment, Lead Placement, and Tracing Acquisition & Rhythm Recognition, Interpretation, and Reporting

  • Complete two full-length timed practice exams covering all four domains and score 85% or higher on each

  • Write the correct rationale for every missed item and group misses by domain

  • Re-demonstrate the 12-lead setup and a five-rhythm rapid-read drill under time pressure

  • State the final weak-area list and the specific review actions to take before test day

Your checkpoint

Two scored practice exams with a complete error log and a one-page readiness self-assessment naming remaining weak areas

Milestones

Week 2: Score 90% or higher on the interval and rate calculation worksheet and correctly label the full conduction system without notes

Week 4: Score 80% or higher on a 25-question mixed quiz covering domains 2 and 3 and complete a timed 12-lead setup in under 5 minutes

Week 6: Score 85% or higher on the 20-strip rhythm quiz and correctly write escalation statements for all five lethal rhythms

Week 8: Score 85% or higher on both full-length practice exams and show a declining trend in domain-level error counts

NHA EKG Technician exam day

Your checklist

Government-issued photo ID

Bring an unexpired, signed photo ID (driver's license, state ID, passport, or military ID). The name on it must match your registration exactly. Confirm the accepted ID list with the provider before test day.

Appointment confirmation / authorization to test

Bring the confirmation email or authorization document you received when you scheduled. Confirm with the provider whether a printed copy is required, since some centers restrict phone use in the testing room.

Confirm testing center location, arrival time, and parking

Look up the address, transit or parking options, and the check-in time stated on your confirmation. Do a dry run or map review the day before so morning delays do not cost you your seat.

Confirm exam format and passing standard

Before test day, verify the number of scored items, pretest items, time limit, and passing score from the provider's official candidate handbook. Do not rely on secondhand numbers.

Plan for security screening and item storage

Leave jewelry, watches, and anything that may set off screening or be barred from the room at home. Confirm with the provider whether lockers are available for keys, wallet, and coat.

Light content review only

Skim only high-yield EKG material: lead placement, rate calculation methods, interval norms, basic rhythm recognition, and common artifacts. Stop studying new material the night before.

Rest, food, and hydration plan

Sleep on a normal schedule, eat a normal meal, and limit caffeine if it makes you jittery. Use the restroom before check-in; unscheduled breaks may count against your time.

Simple layered clothing

Dress in comfortable layers and flat shoes. Avoid clothing with metal that could slow screening and anything that makes you uncomfortable for a multi-hour session.

Backup plan for the morning

Set two alarms, arrange transportation in advance, and save the testing center's phone number so you can call if something goes wrong.

Plan the day

Final 72 hours

Re-read the provider's candidate handbook for check-in rules, ID requirements, prohibited items, and scoring. Confirm your appointment date, time, and address. Do one or two short review sessions on lead placement, rate calculation, intervals, and rhythm identification; then stop adding new material.

Final 72 hours

Do a practice run of the route to the center and note parking or transit costs. Decide what you will carry in and what stays home.

24 hours before

Pack your ID, confirmation document, and a small snack for afterward. Lay out clothes. Get a normal night's sleep rather than cramming; fatigue hurts performance on rhythm-strip questions more than one more hour of review helps.

24 hours before

Do a final 30-45 minute review of your weakest area only, then put materials away. Confirm alarms and transportation.

Morning of

Eat a normal meal, limit fluids right before you leave, and arrive earlier than the stated check-in time. Call the center if you are delayed or cannot find the room.

At check-in

Present your ID and confirmation, follow the proctor's instructions for storing personal items, and ask the proctor to clarify any rule you are unsure about before the clock starts.

During the test

Read each item fully, including whether it asks for the best, first, or most likely answer. Answer the items you know first; on rhythm questions, systematically check rate, regularity, P waves, PR interval, and QRS width before choosing. Track your remaining time and leave nothing blank unless the format penalizes guessing - confirm that with the provider.

After the test

Ask the proctor how and when results will be released, and keep your score report for your records.

Rules to check

  • Bring valid, unexpired, signed photo ID. The name must match your registration exactly; if it does not, contact the provider before test day.

  • Do not bring phones, smartwatches, notes, or study materials into the testing room. Assume all personal items must be stored; confirm locker availability with the provider.

  • Follow every instruction from the testing center staff. Talking, looking at others' screens, or accessing unauthorized materials can void your score.

  • Use the restroom before check-in. If you leave the testing room mid-exam, the time may keep running or you may not be allowed to resume - confirm the center's policy with the provider.

  • Read and accept the confidentiality agreement honestly. Do not discuss, reproduce, or share specific exam content afterward.

  • Scoring is determined by the provider, not the proctor. Confirm the passing standard and retake policy in the official candidate handbook rather than estimating from the number of questions you think you missed.

  • If equipment or the testing environment causes a problem, raise your hand and tell the proctor immediately rather than trying to work around it.

NHA EKG Technician FAQ

How many NHA EKG Technician practice questions are available?

The practice set has 200 NHA EKG Technician questions. Each one includes the choices, the correct answer, and an explanation, and the set is free to read with no signup.

How many NHA EKG Technician flashcards are available?

The flashcard set has 32 NHA EKG Technician cards. Each card shows the term and its definition.

Which topics does the NHA EKG Technician study material cover?

The NHA EKG Technician study material has 4 sections, including Patient Preparation, Safety, and Infection Control, Cardiovascular Anatomy, Physiology, and Electrophysiology, and EKG Equipment, Lead Placement, and Tracing Acquisition.