NBRC CRT Practice Test

Certified Respiratory Therapist (CRT) - Therapist Multiple-Choice (TMC) Examination

NBRC CRT overview

  • 200 practice questions
  • 32 flashcards
  • 3 study guide topics
  • 37 key terms

What you'll study

  • Patient Data33%
  • Troubleshooting and Quality Control of Equipment and Infection Control33%
  • Initiation and Modification of Therapeutic Interventions34%

The Certified Respiratory Therapist (CRT) credential is awarded by the NBRC to candidates who pass the Therapist Multiple-Choice (TMC) Examination, which objectively measures the essential knowledge, skills, and abilities required of respiratory therapists at entry into practice. It is aimed at graduates of accredited respiratory therapy education programs and at credentialed therapists pursuing RRT eligibility, and it matters well beyond the exam room: all 49 states that regulate the practice of respiratory care use the CRT or RRT credential as the basis for state licensure. The exam is a single three-hour, multiple-choice test of 160 items, 140 of which are scored and 20 of which are pretest items, drawn from the NBRC Detailed Content Outline. Two cut scores apply; the low cut score earns the CRT credential, while the high cut score earns the CRT and makes you eligible for the Clinical Simulation Examination, provided you qualify. Preparation should follow the content outline section by section, supplemented by the free online practice examination and, if you want scoring feedback, the official Self-Assessment Examination. Candidates testing in 2027 or later should note that a new Respiratory Therapy Examination replaces the TMC.

Common mistakes

Reads the answer options first and picks the one containing a familiar keyword from the stem, instead of classifying the data before looking at choices.

Under time pressure, options act as a word-association cue; the candidate recognizes 'wheezing' or 'CO2' and stops thinking, so a plausible-sounding distractor wins.

What to do instead

Cover the options with your hand, write a one-line interpretation of the data in the stem (e.g., 'hypoxemia with normal PaCO2, no response to O2'), then uncover and eliminate every option not consistent with that line.

Skips or misreads the qualifier in the stem - 'initial,' 'most appropriate,' 'EXCEPT,' 'contraindicated,' 'least likely' - and answers the unqualified version of the question.

The qualifier is a single word in a long stem, and the candidate is already predicting the answer from the clinical scenario, so the reversed or priority-based question reads as a straightforward one.

What to do instead

Circle the qualifier before reading any option and rewrite the stem as a question in your own words ('What do I do FIRST?' vs. 'What should NOT be done?'). For EXCEPT items, work the list and mark each of the four true statements.

Interprets a blood gas on pH alone - labels a pH of 7.35-7.37 'normal' and misses a compensated or partially compensated acidosis, or misses a mixed disorder because only one abnormality is named.

Teaching emphasis on the 7.35-7.45 range makes a near-normal pH feel like a normal gas; candidates stop before checking whether PaCO2 and HCO3- move in compensating directions.

What to do instead

Always run a fixed four-step routine: pH (acidemia/alkalemia) → PaCO2 (respiratory component) → HCO3-/base excess (metabolic component) → compensation check. If both PaCO2 and HCO3- are abnormal in opposite directions, do not call it normal; name it as compensated or mixed.

Attributes a high-pressure ventilator alarm to a leak or disconnection, or blames the wrong component because peak and plateau pressures were not compared.

All alarms feel like 'the ventilator is unhappy,' and candidates memorize a flat list of causes without the peak-vs-plateau distinction that separates resistance problems from compliance problems.

What to do instead

Use a fixed differential: high peak with normal plateau = increased airway resistance (secretions, kink, biting, bronchospasm); high peak with high plateau = decreased compliance (pneumothorax, atelectasis, mainstem intubation, abdominal distension); low pressure = leak, cuff, or disconnection. Check the patient before the machine, then trace circuit → airway → lung.

Answers with a clinical intervention when the scenario is an equipment failure or QC failure - e.g., selects 'suction the patient' when the device is inoperative or uncalibrated, or never verifies oxygen analyzer calibration and pre-use checkout.

Candidates study disease management more than device function, so the respiratory-care answer feels more 'correct' than the equipment answer even when the equipment is the actual problem.

What to do instead

Build a one-page pre-use checklist (leak test, alarm limits, O2 analyzer calibration with room air and 100% O2, heated humidifier set point, circuit and valve function) and a matching 'alarm/error → first check' table. When a stem mentions a device alarm or failure, resolve the device before escalating therapy.

Skips the infection-control step in the scenario - no hand hygiene or PPE before suctioning, reuse of a single-use suction catheter, failure to drain circuit condensate away from the patient, or failure to isolate a suspected airborne-disease patient.

Infection control is treated as background rather than as a scored action, so the candidate's attention goes to the respiratory maneuver and a breach of standard precautions sits unnoticed in the option list.

What to do instead

Before answering any procedure item, scan each option for a precaution breach (gloves/hand hygiene, sterile vs. clean technique, single-use device, condensate handling, airborne/droplet/contact precautions). Any option containing a breach is eliminated regardless of how well it treats the lungs.

Selects an oxygen device that cannot deliver the ordered FiO2 or flow - nasal cannula for a prescribed 60%, nonrebreather for a stable patient ordered 28%, or assumes a cannula delivers a fixed FiO2 at any flow.

Devices are remembered as a list of names with approximate numbers rather than as low-flow vs. high-flow with different dependence on the patient's inspiratory demand.

What to do instead

Memorize a device table (approximate FiO2 per flow for cannula, simple mask, air-entrainment mask, partial and nonrebreather, high-flow) and answer from the target FiO2 plus the patient's minute ventilation, not from the device's reputation. Remember air-entrainment masks are the only common low-flow device that gives a fixed, prescribed FiO2.

Calculates tidal volume or drug/oxygen math from the weight printed in the stem instead of the ideal body weight, or miscomputes the air:oxygen ratio for an air-entrainment device.

The actual body weight is the visible number; the IBW formula is memorized but not triggered, and ratio questions are guessed from a remembered answer rather than derived.

What to do instead

Default to IBW for any lung-volume calculation: male 50 + 2.3 kg per inch over 60, female 45.5 + 2.3 per inch over 60, then 6-8 mL/kg IBW. Derive air:O2 from the formula (ratio = (100 - FiO2)/(FiO2 - 21)) and check that your answer falls between 1:1 and 1:4.

Initiates a modality without screening for contraindications - incentive spirometry or IPPB in an untreated pneumothorax or active hemoptysis, or noninvasive ventilation in a patient who cannot protect the airway or is deteriorating.

The stem emphasizes benefit ('postoperative, atelectasis, needs lung expansion'), and the contraindication is either implied by one hidden data point or absent, so the candidate commits to the therapy that fits the indication.

What to do instead

For every modality, rehearse a short contraindication list before the exam (pneumothorax, hemoptysis, unstable hemodynamics, inability to protect airway or clear secretions, facial trauma for NIV, untreated vomiting/ileus) and check the stem's data against it before choosing to initiate.

Changes therapy and never evaluates the response - keeps escalating FiO2 when SpO2 does not improve, or continues a protocol on a deteriorating patient instead of modifying based on objective response.

The candidate treats the initial order as the answer and does not recognize that the question is asking for the next modification; failure to improve with supplemental oxygen is not linked to shunt, dead-space, or a displaced/artifactual probe.

What to do instead

Adopt a rule: any change in therapy in a scenario must be followed by a named reassessment (SpO2, blood gas, work of breathing, vital signs) and a decision point. When oxygenation does not improve with increasing FiO2, stop escalating and consider intrapulmonary shunt, inadequate cardiac output, or a technical problem with the measurement.

Exam requirements can change. Confirm current details with the exam provider.

NBRC CRT practice

200 questions. Each one lists the choices, the correct answer, and an explanation. With JavaScript, this list opens one question at a time. The checker at the top of this page saves progress in this browser when it is available.

  1. Question 1Patient Data

    Which resting respiratory rate for a healthy adult is within the normal range?

    1. 4 breaths/min
    2. 36 breaths/min
    3. 28 breaths/min
    4. 12 breaths/min Correct answer.

    Explanation

    The accepted normal adult resting respiratory rate is roughly 12 to 20 breaths per minute. Values below 12 define bradypnea and values above 20 define tachypnea, and either finding requires further evaluation of the patient.

  2. Question 2Patient Data

    Which resting heart rate is within normal limits for a healthy adult?

    1. 112 beats/min
    2. 140 beats/min
    3. 38 beats/min
    4. 72 beats/min Correct answer.

    Explanation

    The normal adult resting heart rate is approximately 60 to 100 beats per minute. Rates outside this window are described as bradycardia or tachycardia and should be correlated with the patient's clinical status.

  3. Question 3Patient Data

    Which breath sound is most consistent with secretions in the larger airways?

    1. Vesicular sounds over the periphery
    2. A pleural friction rub
    3. Fine crackles at both bases
    4. Coarse rhonchi clearing with cough Correct answer.

    Explanation

    Coarse, low-pitched rhonchi arise from turbulent flow through secretions in the larger airways and typically change or clear after coughing. Vesicular sounds are normal, fine crackles suggest distal airway or alveolar fluid, and a friction rub arises from inflamed pleura.

  4. Question 4Patient Data

    Which SpO2 range is generally considered normal for a healthy adult breathing room air at sea level?

    1. 95% to 100% Correct answer.
    2. 80% to 84%
    3. 85% to 89%
    4. 70% to 79%

    Explanation

    A healthy adult breathing room air at sea level typically has an SpO2 of about 95% to 100%. Values below roughly 90% represent significant hypoxemia and warrant further assessment and possible oxygen therapy.

  5. Question 5Patient Data

    A patient reports shortness of breath that begins when lying flat and resolves on sitting upright. Which term describes this finding?

    1. Platypnea
    2. Orthopnea Correct answer.
    3. Paroxysmal nocturnal dyspnea
    4. Trepopnea

    Explanation

    Orthopnea is dyspnea produced by the supine position and relieved by sitting or standing upright, and it is commonly graded by the number of pillows required. Platypnea is the opposite pattern, and paroxysmal nocturnal dyspnea refers to episodes that wake the patient from sleep.

  6. Question 6Patient Data

    Pulse oximetry directly estimates which of the following?

    1. Arterial carbon dioxide tension
    2. Arterial hemoglobin oxygen saturation Correct answer.
    3. Plasma bicarbonate concentration
    4. Cardiac output

    Explanation

    A pulse oximeter uses differential light absorption to estimate the percentage of hemoglobin binding sites saturated with oxygen. It provides no information about carbon dioxide, acid-base status, or cardiac output.

  7. Question 7Patient Data

    A patient with a long-standing history of COPD typically presents with which chest configuration?

    1. Kyphoscoliosis
    2. Increased anterior-posterior diameter Correct answer.
    3. Flail chest
    4. Pectus excavatum

    Explanation

    Chronic air trapping in COPD leads to hyperinflation and a barrel chest, in which the anterior-posterior diameter approaches the lateral diameter. Pectus excavatum and kyphoscoliosis are structural deformities, and flail chest follows acute trauma.

  8. Question 8Patient Data

    Which oral temperature is within the normal adult range?

    1. 34.4 C (94.0 F)
    2. 35.0 C (95.0 F)
    3. 37.0 C (98.6 F) Correct answer.
    4. 40.0 C (104.0 F)

    Explanation

    Normal oral temperature is approximately 36.5 to 37.5 C (97.7 to 99.5 F), making 37.0 C (98.6 F) the normal value listed. Lower readings indicate hypothermia and higher readings indicate fever.

  9. Question 9Patient Data

    A patient's right chest wall segment moves inward during inspiration while the rest of the chest expands. This finding is most consistent with which condition?

    1. Flail chest Correct answer.
    2. Tension pneumothorax
    3. Atelectasis of the left lung
    4. Pulmonary embolism

    Explanation

    Paradoxical inward movement of a chest wall segment during inspiration occurs when multiple adjacent ribs are fractured in two places, creating a free-floating segment known as flail chest. The remainder of the chest expands normally while the unstable segment is drawn inward by negative intrathoracic pressure.

  10. Question 10Patient Data

    During auscultation the patient says "E" and the clinician hears "A" over the right lower lobe. This finding indicates which of the following?

    1. A normal finding over the trachea
    2. A pneumothorax on that side
    3. Consolidation of the underlying lung Correct answer.
    4. Retained secretions in the airways

    Explanation

    Egophony is the transformation of a spoken "E" into an "A" sound, produced when sound travels more efficiently through consolidated lung tissue. It is a sign of increased transmission through solid rather than air-filled parenchyma.

  11. Question 11Patient Data

    What diaphragmatic excursion is expected during deep breathing in a healthy adult?

    1. 3 to 5 cm Correct answer.
    2. 10 to 12 cm
    3. 1 to 2 cm
    4. 7 to 9 cm

    Explanation

    Percussion of the diaphragm during deep breathing normally shows about 3 to 5 cm of excursion in a healthy adult. Reduced excursion suggests hyperinflation, phrenic nerve dysfunction, or restrictive disease.

  12. Question 12Patient Data

    Digital clubbing is most commonly associated with which of the following?

    1. Simple pneumothorax
    2. Acute asthma exacerbation
    3. Pulmonary embolism
    4. Chronic hypoxemic lung disease Correct answer.

    Explanation

    Clubbing develops over months to years in association with chronic hypoxemia, most often from cystic fibrosis, bronchiectasis, lung cancer, or congenital heart disease. Acute processes such as asthma, pneumothorax, or embolism do not produce clubbing.

  13. Question 13Patient Data

    At what bed position should a patient be placed to assess jugular venous distention?

    1. Trendelenburg with the head low
    2. Prone with the head turned
    3. Supine and flat with legs elevated
    4. Semi-Fowler's at 30 to 45 degrees Correct answer.

    Explanation

    Jugular venous pressure is assessed with the patient reclined at roughly 30 to 45 degrees so the sternal angle serves as a reproducible reference point. The height of the venous column above the sternal angle estimates right atrial pressure.

  14. Question 14Patient Data

    A blood pressure cuff shows a 12 mm Hg fall in systolic pressure during inspiration. This finding is best described as which of the following?

    1. Pulsus alternans
    2. Pulsus paradoxus Correct answer.
    3. A narrowed pulse pressure
    4. A normal inspiratory variation

    Explanation

    A systolic decline greater than 10 mm Hg during inspiration is termed pulsus paradoxus and reflects impaired right ventricular filling or exaggerated ventricular interdependence. It is classically seen in severe asthma, pericardial tamponade, and constrictive pericarditis.

  15. Question 15Patient Data

    Which instruction is most appropriate when collecting a sputum specimen for culture?

    1. Collect the sample immediately after a nebulizer treatment
    2. Collect the sample after the patient has eaten breakfast
    3. Collect saliva in the container and label it as sputum
    4. Rinse the mouth and collect the sample on arising Correct answer.

    Explanation

    A reliable sputum specimen is obtained on arising, before eating, after rinsing the mouth with water to reduce oral contamination. The patient should be instructed to cough deeply and expectorate material from the lower airway rather than saliva.

  16. Question 16Patient Data

    Which end-tidal CO2 value is expected in a healthy, spontaneously breathing adult?

    1. 50 to 55 mm Hg
    2. 35 to 45 mm Hg Correct answer.
    3. 20 to 25 mm Hg
    4. 10 to 15 mm Hg

    Explanation

    End-tidal CO2 in a healthy adult approximates the arterial CO2 tension at about 35 to 45 mm Hg. Values well below this range suggest hyperventilation, poor perfusion, or a sampling problem, while higher values suggest hypoventilation.

  17. Question 17Patient Data

    Which maximum inspiratory pressure (MIP) value is within normal limits for an adult?

    1. +10 cm H2O
    2. -80 cm H2O Correct answer.
    3. -5 cm H2O
    4. -15 cm H2O

    Explanation

    Normal adult MIP is roughly -60 to -100 cm H2O, and more negative values indicate greater inspiratory muscle strength. A value near -20 to -25 cm H2O or less negative suggests inspiratory muscle weakness.

  18. Question 18Patient Data

    Which tool is used to quantify a patient's perceived breathlessness at the bedside?

    1. Modified Borg scale Correct answer.
    2. APACHE II score
    3. Murray lung injury score
    4. Glasgow Coma Scale

    Explanation

    The modified Borg scale asks the patient to rate the intensity of dyspnea on a numbered categorical scale, allowing change over time or with intervention to be tracked. The other instruments grade consciousness, critical illness severity, and lung injury rather than perceived breathlessness.

  19. Question 19Patient Data

    Percussion over the posterior chest produces a dull note over the left base. This finding is most consistent with which of the following?

    1. A left-sided pneumothorax
    2. Fluid or solid tissue in the left pleural space Correct answer.
    3. Normal lung tissue
    4. Hyperinflation of the left lung

    Explanation

    Percussion over air-filled lung is resonant; dullness indicates that air has been replaced by fluid or solid tissue, as with a pleural effusion, consolidation, or atelectasis. Hyperinflation and pneumothorax instead produce hyperresonance.

  20. Question 20Patient Data

    Which assessment finding indicates increased work of breathing in an adult?

    1. Supraclavicular retractions with each breath Correct answer.
    2. Abdominal motion during quiet rest
    3. Symmetric chest expansion
    4. A respiratory rate of 14 breaths/min

    Explanation

    Retractions occur when accessory muscles pull the compliant chest wall inward to overcome increased resistance or reduced compliance, signaling elevated work of breathing. Normal resting breathing is unlabored, symmetric, and does not draw in the suprasternal or supraclavicular tissues.

  21. Question 21Patient Data

    A patient has smoked 1.5 packs per day for 24 years. What is the pack-year history?

    1. 24 pack-years
    2. 16 pack-years
    3. 36 pack-years Correct answer.
    4. 60 pack-years

    Explanation

    Pack-years are calculated by multiplying packs smoked per day by the number of years smoked, so 1.5 times 24 equals 36 pack-years. This value quantifies cumulative tobacco exposure and is used in risk assessment.

  22. Question 22Patient Data

    Deep, rapid respirations with a prolonged inspiratory phase and no pause in a patient with metabolic acidosis describes which pattern?

    1. Kussmaul breathing Correct answer.
    2. Apneustic breathing
    3. Biot's respiration
    4. Cheyne-Stokes respiration

    Explanation

    Kussmaul breathing is deep and rapid, driven by the respiratory center's attempt to blow off carbon dioxide in metabolic acidosis. It is most often associated with diabetic ketoacidosis and renal failure.

  23. Question 23Patient Data

    Which finding meets the criteria for orthostatic hypotension?

    1. Systolic rise of 15 mm Hg with standing
    2. Heart rate rise of 8 beats/min with standing
    3. Systolic drop of 25 mm Hg with standing Correct answer.
    4. Diastolic rise of 10 mm Hg with standing

    Explanation

    Orthostatic hypotension is defined as a fall in systolic pressure of at least 20 mm Hg or in diastolic pressure of at least 10 mm Hg within three minutes of standing. A compensatory heart rate increase often accompanies the change but is not part of the diagnostic criteria.

  24. Question 24Patient Data

    Central cyanosis generally becomes visible when which amount of deoxygenated hemoglobin is present?

    1. 1 g/dL
    2. 10 g/dL
    3. 5 g/dL Correct answer.
    4. 3 g/dL

    Explanation

    Cyanosis is detected when roughly 5 g/dL or more of hemoglobin is unsaturated, so it depends on the absolute amount of deoxygenated hemoglobin rather than saturation alone. This is why anemic patients may be profoundly hypoxemic without appearing cyanotic.

  25. Question 25Patient Data

    A patient with suspected carbon monoxide poisoning has an SpO2 of 99%. How should this reading be interpreted?

    1. Suggestive of device failure that needs repeat testing
    2. Falsely high; carboxyhemoglobin reads as oxyhemoglobin Correct answer.
    3. Reliable evidence of adequate tissue oxygen delivery
    4. Accurate, and it rules out significant hypoxemia

    Explanation

    Standard pulse oximeters cannot distinguish carboxyhemoglobin from oxyhemoglobin, so a normal reading does not exclude significant impairment of oxygen delivery in carbon monoxide poisoning. A co-oximeter measuring carboxyhemoglobin is required for accurate assessment.

  26. Question 26Patient Data

    What is the normal resting respiratory rate for a healthy adult?

    1. 30 to 36 breaths/min
    2. 22 to 28 breaths/min
    3. 12 to 20 breaths/min Correct answer.
    4. 8 to 10 breaths/min

    Explanation

    The normal adult resting respiratory rate is approximately 12 to 20 breaths/min. Rates below or above this range can reflect sedation, fatigue, pain, fever, or respiratory distress.

  27. Question 27Patient Data

    Which resting heart rate range is normal for an adult?

    1. 100 to 140 beats/min
    2. 60 to 100 beats/min Correct answer.
    3. 40 to 60 beats/min
    4. 80 to 120 beats/min

    Explanation

    Normal resting heart rate for an adult is about 60 to 100 beats/min. Bradycardia is generally below 60, and tachycardia is above 100.

  28. Question 28Patient Data

    Which SpO2 range is generally expected in a healthy adult breathing room air at sea level?

    1. 88% to 92%
    2. 80% to 85%
    3. 90% to 94%
    4. 95% to 100% Correct answer.

    Explanation

    A healthy adult breathing room air at sea level typically has an SpO2 of 95% to 100%. Values persistently below 90% indicate hypoxemia and warrant evaluation.

  29. Question 29Patient Data

    What is the total score range of the Glasgow Coma Scale?

    1. 5 to 20
    2. 0 to 10
    3. 3 to 15 Correct answer.
    4. 1 to 12

    Explanation

    The Glasgow Coma Scale sums eye (1-4), verbal (1-5), and motor (1-6) scores, giving a total range of 3 to 15. Lower scores indicate a lower level of consciousness.

  30. Question 30Patient Data

    Which arterial blood pH range is normal for an adult?

    1. 7.20 to 7.30
    2. 7.30 to 7.35
    3. 7.35 to 7.45 Correct answer.
    4. 7.45 to 7.55

    Explanation

    Normal arterial pH is 7.35 to 7.45. A pH below 7.35 indicates acidemia, and a pH above 7.45 indicates alkalemia.

  31. Question 31Patient Data

    Which PaO2 range is considered normal for a healthy adult breathing room air?

    1. 40 to 60 mm Hg
    2. 20 to 40 mm Hg
    3. 80 to 100 mm Hg Correct answer.
    4. 100 to 120 mm Hg

    Explanation

    A normal PaO2 for a healthy adult breathing room air is roughly 80 to 100 mm Hg. Values below 60 mm Hg indicate severe hypoxemia.

  32. Question 32Patient Data

    Which breath sound is normally heard over the trachea?

    1. Bronchial Correct answer.
    2. Vesicular
    3. Crackles
    4. Pleural friction rub

    Explanation

    Bronchial breath sounds are normally heard over the trachea because airflow is turbulent in the large central airway. Vesicular sounds are heard over the lung periphery, and crackles or rubs are abnormal.

  33. Question 33Patient Data

    Vesicular breath sounds are best heard over which area?

    1. Over the mainstem bronchi
    2. Over the sternum
    3. Over the lung periphery Correct answer.
    4. Over the trachea

    Explanation

    Vesicular breath sounds are soft, low-pitched, and heard over the lung periphery where airflow reaches small airways and alveoli. They are not the normal sound over the trachea or mainstem bronchi.

  34. Question 34Patient Data

    Fine crackles heard at the lung bases during inspiration most often result from which mechanism?

    1. Inflamed pleural surfaces
    2. Opening of collapsed alveoli Correct answer.
    3. Narrowed large airways
    4. Decreased pulmonary compliance

    Explanation

    Fine crackles occur when collapsed small airways and alveoli pop open during inspiration, often with fluid in the airspaces. They are not caused by pleural inflammation or large-airway narrowing.

  35. Question 35Patient Data

    Diffuse expiratory wheezing during auscultation most directly suggests which finding?

    1. Alveolar consolidation
    2. Reduced diaphragmatic excursion
    3. Lower airway narrowing Correct answer.
    4. Pleural fluid

    Explanation

    Diffuse expiratory wheezing reflects narrowing of lower airways, as in asthma or bronchospasm. Pleural fluid and consolidation produce different auscultatory findings.

  36. Question 36Patient Data

    A harsh, high-pitched inspiratory sound heard without a stethoscope most suggests which condition?

    1. Upper airway obstruction Correct answer.
    2. Pulmonary edema
    3. Pleural inflammation
    4. Peripheral airway collapse

    Explanation

    Stridor is a harsh, high-pitched inspiratory sound caused by obstruction of the upper airway, such as laryngeal edema or a foreign body. It is a sign of a potentially emergent airway problem.

  37. Question 37Patient Data

    A grating sound heard during both inspiration and expiration over the lateral chest wall most suggests which finding?

    1. Alveolar fluid
    2. Bronchial obstruction
    3. Pleural inflammation Correct answer.
    4. Air trapping

    Explanation

    A pleural friction rub is a grating sound heard during both inspiration and expiration when inflamed pleural surfaces rub together. It is not caused by airflow obstruction or alveolar fluid.

  38. Question 38Patient Data

    Tactile fremitus is typically increased over an area of lung affected by which process?

    1. Consolidation Correct answer.
    2. Pleural effusion
    3. Pneumothorax
    4. Hyperinflation

    Explanation

    Consolidated lung tissue transmits vocal and tactile vibrations more readily, increasing tactile fremitus. Air or fluid in the pleural space tends to reduce transmission.

  39. Question 39Patient Data

    Tracheal deviation toward the affected side is most consistent with which finding?

    1. Flail chest
    2. Large pleural effusion
    3. Atelectasis Correct answer.
    4. Tension pneumothorax

    Explanation

    Atelectasis causes volume loss in the affected lung, which pulls the mediastinum and trachea toward that side. Space-occupying processes such as tension pneumothorax or large effusion push the trachea away.

  40. Question 40Patient Data

    What bladder width is recommended for an appropriately sized blood pressure cuff?

    1. About 60% of the arm circumference
    2. About 40% of the arm circumference Correct answer.
    3. About 80% of the arm circumference
    4. About 20% of the arm circumference

    Explanation

    A blood pressure cuff bladder should be about 40% of the arm circumference in width and about 80% in length. A cuff that is too narrow or short can falsely elevate the reading.

  41. Question 41Patient Data

    A sputum specimen that is thick, yellow-green, and purulent most likely indicates which finding?

    1. Pulmonary thromboembolism
    2. Viral bronchospasm
    3. Bacterial infection Correct answer.
    4. Pleural effusion

    Explanation

    Thick, yellow-green sputum suggests the presence of neutrophils and bacteria, consistent with a bacterial respiratory infection. The specimen should still be sent for culture to identify the organism.

  42. Question 42Patient Data

    Which pain assessment tool is designed for nonverbal critically ill adults who cannot self-report?

    1. Numeric rating scale for adult self-report
    2. Wong-Baker FACES scale for pediatric self-report
    3. Critical-Care Pain Observation Tool Correct answer.
    4. Visual analog scale for adult self-report

    Explanation

    The Critical-Care Pain Observation Tool uses behavioral and physiologic indicators for patients who cannot self-report pain, such as intubated adults. Numeric and visual analog scales require self-report.

  43. Question 43Patient Data

    Bilateral pinpoint pupils in an unresponsive patient most suggest exposure to which substance?

    1. Amphetamines
    2. Salicylates
    3. Opioids Correct answer.
    4. Atropine

    Explanation

    Opioid toxicity classically produces pinpoint pupils along with depressed consciousness and respiratory depression. Anticholinergic and stimulant exposures tend to dilate the pupils.

  44. Question 44Patient Data

    When measuring peak expiratory flow, how many efforts should generally be obtained and what value is recorded?

    1. Three efforts; record the best value Correct answer.
    2. One effort; record the first value
    3. Five efforts; record the lowest value
    4. Two efforts; average them

    Explanation

    Peak expiratory flow is measured with up to three acceptable efforts, and the best value is recorded because it best reflects the patient's maximal effort. The patient should stand and seal the lips around the mouthpiece.

  45. Question 45Patient Data

    On a chest radiograph, how does air within the pleural space appear?

    1. Radiopaque and white
    2. Calcified and bright
    3. Radiolucent and dark Correct answer.
    4. Isodense with bone

    Explanation

    Air attenuates x-rays poorly, so it appears radiolucent and dark on a chest radiograph. Fluid, soft tissue, and bone appear progressively more radiopaque and white.

  46. Question 46Patient Data

    An arterial blood gas shows pH 7.28, PaCO2 60 mm Hg, and HCO3 26 mEq/L. How should this be interpreted?

    1. Metabolic alkalosis
    2. Compensated metabolic acidosis
    3. Respiratory alkalosis with compensation
    4. Uncompensated respiratory acidosis Correct answer.

    Explanation

    The pH is acidemic, and the elevated PaCO2 identifies a respiratory cause. The near-normal HCO3 indicates that metabolic compensation has not yet occurred.

  47. Question 47Patient Data

    An arterial blood gas shows pH 7.25, PaCO2 30 mm Hg, and HCO3 15 mEq/L. Which interpretation is most accurate?

    1. Metabolic alkalosis with respiratory compensation
    2. Metabolic acidosis with respiratory compensation Correct answer.
    3. Uncompensated respiratory alkalosis
    4. Respiratory acidosis with full metabolic compensation

    Explanation

    The low pH and low HCO3 identify a primary metabolic acidosis. The low PaCO2 reflects compensatory hyperventilation, which lowers carbon dioxide to help restore pH.

  48. Question 48Patient Data

    Spirometry shows an FEV1/FVC ratio of 58% with a reduced FEV1. This pattern is most consistent with which defect?

    1. Fixed upper airway obstruction
    2. Obstructive defect Correct answer.
    3. Restrictive defect
    4. Normal spirometry

    Explanation

    An FEV1/FVC ratio below 70% after bronchodilator testing is the hallmark of an obstructive defect. Restrictive disease reduces FVC but usually preserves or increases the ratio.

  49. Question 49Patient Data

    Which set of findings most suggests tension pneumothorax?

    1. Tracheal deviation toward the affected side with dull percussion and egophony
    2. Unilateral wheezing with prolonged expiration
    3. Bilateral crackles with frothy sputum
    4. Tracheal deviation away from the affected side with absent breath sounds Correct answer.

    Explanation

    Tension pneumothorax raises intrathoracic pressure, collapsing the affected lung and pushing the mediastinum and trachea to the opposite side. Breath sounds are absent on the affected side and hypotension may develop.

  50. Question 50Patient Data

    A patient has a respiratory rate of 20 breaths/min and a tidal volume of 400 mL. What is the minute ventilation?

    1. 4 L/min
    2. 8 L/min Correct answer.
    3. 2 L/min
    4. 20 L/min

    Explanation

    Minute ventilation equals respiratory rate multiplied by tidal volume. With 20 breaths/min and 0.4 L per breath, minute ventilation is 8 L/min.

  51. Question 51Patient Data

    A patient reports smoking two packs of cigarettes per day for 25 years. How many pack-years should be documented in the history?

    1. 100 pack-years
    2. 75 pack-years
    3. 25 pack-years
    4. 50 pack-years Correct answer.

    Explanation

    Pack-years are calculated by multiplying the number of packs smoked per day by the number of years smoked. Here, 2 packs per day times 25 years equals 50 pack-years, a value used to quantify cumulative tobacco exposure and risk.

  52. Question 52Patient Data

    Which respiratory rate range is considered normal for a resting, healthy adult?

    1. 22 to 28 breaths/min
    2. 4 to 8 breaths/min
    3. 12 to 20 breaths/min Correct answer.
    4. 30 to 40 breaths/min

    Explanation

    A resting adult typically breathes 12 to 20 times per minute. Rates below this range indicate bradypnea, and rates above it indicate tachypnea, both of which warrant further assessment.

  53. Question 53Patient Data

    Central cyanosis is most reliably detected by inspecting which area?

    1. The earlobes
    2. The nail beds of the fingers
    3. The lips and oral mucosa Correct answer.
    4. The tips of the toes

    Explanation

    Central cyanosis reflects arterial oxygen desaturation and appears in well-perfused mucous membranes such as the lips, tongue, and oral mucosa. The extremities are more affected by vasoconstriction and cooling, so cyanosis there may be peripheral rather than central.

  54. Question 54Patient Data

    Which pain scale asks a young child to point to the drawing that matches how much hurt they feel?

    1. Numeric rating scale
    2. Visual analog scale
    3. CPOT
    4. Wong-Baker FACES scale Correct answer.

    Explanation

    The Wong-Baker FACES scale uses a series of simple faces ranging from a smile to a distressed expression, allowing children as young as about three years to indicate their pain level. Scales requiring a numerical rating or a mark on a line demand abstract reasoning that young children often lack.

  55. Question 55Patient Data

    A patient correctly states their own name, the name of the hospital, and today's date. How should this be documented?

    1. Alert but disoriented to time
    2. Oriented to person only
    3. Oriented to person, place, and time Correct answer.
    4. Oriented to person and place only

    Explanation

    Orientation is assessed in three spheres: person, place, and time. Correctly identifying self, location, and date demonstrates orientation to all three, commonly written as oriented times three.

  56. Question 56Patient Data

    During mechanical ventilation, the capnogram suddenly shows an end-tidal CO2 of 0 mm Hg with a flat waveform. Which cause is most likely?

    1. Mild hyperventilation
    2. A rising core body temperature
    3. Partial obstruction from secretions
    4. Complete circuit disconnection or an esophageal tube Correct answer.

    Explanation

    End-tidal CO2 falls to zero only when no exhaled carbon dioxide reaches the sensor, as occurs with disconnection, an obstructed sampling line, or placement of the tube in the esophagus. Partial obstruction and hyperventilation alter the waveform shape or amplitude but do not eliminate CO2 entirely.

  57. Question 57Patient Data

    In what position should the patient be placed to assess for jugular venous distention?

    1. Sitting bolt upright at 90 degrees
    2. Standing upright
    3. Semi-Fowler at roughly 45 degrees Correct answer.
    4. Supine and flat without elevation

    Explanation

    Jugular venous pressure is evaluated with the head of the bed elevated about 30 to 45 degrees and the head turned slightly away, so the pulsation can be seen in the neck. Height of the venous column more than about 3 to 4 cm above the sternal angle suggests elevated right-sided pressures.

  58. Question 58Patient Data

    Which finding on inspection of the fingers indicates digital clubbing?

    1. Blanching of the nail beds with pressure
    2. Splinter hemorrhages under the nails
    3. Thickened yellow nails with slow growth
    4. Loss of the normal angle between the nail and the nail bed Correct answer.

    Explanation

    Clubbing is characterized by softening of the nail bed, an increased nail-bed angle beyond 180 degrees, and loss of the normal diamond-shaped window when opposing fingers are pressed together. It is associated with chronic hypoxemia, chronic lung disease, and several nonpulmonary conditions.

  59. Question 59Patient Data

    The modified Medical Research Council (mMRC) scale is used to grade which symptom?

    1. Chest pain on exertion
    2. Cough severity
    3. Daily sputum volume
    4. Breathlessness with activity Correct answer.

    Explanation

    The mMRC scale grades dyspnea from 0 to 4 based on the activity level that provokes breathlessness, such as only with strenuous exercise versus when dressing. It is widely used in chronic obstructive pulmonary disease to characterize symptom burden.

  60. Question 60Patient Data

    A spontaneous sputum specimen is needed for bacterial culture. Which collection approach is best?

    1. Early morning, before antibiotics, after mouth rinse Correct answer.
    2. Right after the evening meal
    3. Late afternoon following vigorous exercise
    4. Only after nebulized saline

    Explanation

    An early-morning specimen contains pooled secretions and is collected before the first dose of antibiotics so that organisms are not suppressed. Rinsing the mouth with water first reduces contamination by oral flora, improving culture reliability.

  61. Question 61Patient Data

    An adult's chest shows an increased anterior-posterior diameter and widened intercostal spaces. This most suggests which finding?

    1. A large left pleural effusion
    2. Flail chest
    3. Chronic hyperinflation Correct answer.
    4. Pectus excavatum

    Explanation

    A barrel-shaped chest with an anterior-posterior diameter approaching the lateral diameter reflects chronic air trapping and hyperinflation, as seen in emphysema. The ribs become more horizontal and the intercostal spaces widen over time.

  62. Question 62Patient Data

    Dullness to percussion over a lower lung zone most suggests which process?

    1. Normal lung tissue
    2. Consolidation or pleural fluid Correct answer.
    3. Air trapping from emphysema
    4. A pneumothorax

    Explanation

    Percussion dullness occurs when air in the lung is replaced by fluid or solid tissue, as with pneumonia, atelectasis, or pleural effusion. Normal lung is resonant, while an air-filled pleural space or hyperinflated lung produces hyperresonance.

  63. Question 63Patient Data

    An apical pulse is 96 beats/min while the radial pulse is 78 beats/min. How should this be reported?

    1. A pulse deficit of 18 beats/min Correct answer.
    2. An expected 18 mm Hg rise in systolic pressure
    3. A normal finding needing no documentation
    4. A pulse deficit of 96 beats/min

    Explanation

    A pulse deficit is the difference between the apically auscultated rate and the peripherally palpated rate, calculated here as 96 minus 78, or 18 beats per minute. It occurs when some ventricular contractions eject too little blood to create a peripheral pulse, as in atrial fibrillation.

  64. Question 64Patient Data

    During blood pressure measurement, a patient's systolic pressure falls 14 mm Hg on inspiration. How should this be interpreted?

    1. Pulsus alternans from left ventricular failure
    2. A normal inspiratory variation
    3. Pulsus paradoxus, an exaggerated inspiratory decline Correct answer.
    4. A widened pulse pressure from aortic regurgitation

    Explanation

    A small inspiratory fall in systolic pressure of up to about 10 mm Hg is normal. A decline greater than 10 mm Hg defines pulsus paradoxus, which is seen in cardiac tamponade, severe asthma, and tension pneumothorax.

  65. Question 65Patient Data

    A patient with carbon monoxide poisoning has a pulse oximeter reading of 99%. Why is this value misleading?

    1. Carboxyhemoglobin absorbs light similarly to oxyhemoglobin Correct answer.
    2. Pulse oximetry samples only venous blood
    3. The device requires calibration at high altitude
    4. Motion artifact always elevates readings

    Explanation

    Standard pulse oximeters use two wavelengths of light and cannot distinguish carboxyhemoglobin from oxyhemoglobin, so saturation appears normal despite severely impaired oxygen delivery. Co-oximetry or measured arterial blood gas analysis is needed to detect the true abnormality.

  66. Question 66Patient Data

    After an inhaled bronchodilator treatment, which change in FEV1 is generally accepted as a significant response in an adult?

    1. Any increase of 50 mL
    2. A 5% increase from baseline
    3. A 12% and 200 mL increase from baseline Correct answer.
    4. A 30% fall from baseline

    Explanation

    Standard interpretation criteria define a positive bronchodilator response as an increase in FEV1 of at least 12% and at least 200 mL from the pre-bronchodilator value. Requiring both the percentage and the absolute volume prevents small baseline values from producing a falsely positive result.

  67. Question 67Troubleshooting and Quality Control of Equipment and Infection Control

    An RT is about to suction a patient's airway, and the hands are not visibly soiled. The preferred hand hygiene step before donning gloves is to:

    1. rub the hands with an alcohol-based product until dry Correct answer.
    2. wash with soap and water for at least 20 seconds
    3. put on gloves and clean the hands afterward
    4. use a disinfectant wipe on the gloves before contact

    Explanation

    Alcohol-based hand rub is the preferred routine hand hygiene method when hands are not visibly soiled because it is fast and effective. Soap and water is reserved for visibly soiled hands and for organisms such as C. difficile.

  68. Question 68Troubleshooting and Quality Control of Equipment and Infection Control

    An oxygen regulator will not attach to an E cylinder because the pins do not align. This safety system is designed to:

    1. prevent gas from flowing back into the cylinder
    2. limit the cylinder pressure to 50 psi
    3. prevent connection of a regulator intended for a different gas Correct answer.
    4. indicate the remaining cylinder volume

    Explanation

    The pin index safety system uses gas-specific pin positions so that a regulator for one gas cannot be connected to a cylinder of another gas. This prevents delivery of the wrong gas to the patient.

  69. Question 69Troubleshooting and Quality Control of Equipment and Infection Control

    A ventilator high-pressure alarm activates during volume-controlled ventilation. Which finding is the most likely cause?

    1. a disconnected patient circuit
    2. an empty oxygen cylinder
    3. a leak around the tracheostomy cuff
    4. kinked inspiratory tubing Correct answer.

    Explanation

    High-pressure alarms occur when resistance to gas flow increases, such as with a kink, obstruction, or decreased lung compliance. Disconnections and cuff leaks tend to produce low-pressure or low-volume alarms.

  70. Question 70Troubleshooting and Quality Control of Equipment and Infection Control

    After a patient is turned, the ventilator's low-pressure alarm sounds and exhaled tidal volume falls. The first action is to:

    1. suction the airway
    2. inspect the circuit for disconnection Correct answer.
    3. change the flow sensor
    4. increase the high-pressure limit

    Explanation

    A low-pressure alarm with a fall in exhaled volume most often indicates a leak or disconnection in the breathing circuit. The therapist should immediately inspect the patient and circuit.

  71. Question 71Troubleshooting and Quality Control of Equipment and Infection Control

    Before use, a galvanic oxygen analyzer is calibrated in room air and reads 21%. This indicates that the analyzer is:

    1. set for 100% oxygen calibration
    2. reading falsely low
    3. calibrated and ready for use Correct answer.
    4. in need of a new battery

    Explanation

    Room air contains approximately 21% oxygen, so a reading of 21% after calibration in room air is expected. The analyzer can be used if the reading is stable and within the acceptable calibration range.

  72. Question 72Troubleshooting and Quality Control of Equipment and Infection Control

    A pulse oximeter tracing is erratic and the SpO2 drops whenever the patient moves the hand. The most likely cause is:

    1. a low cardiac output state
    2. methemoglobinemia
    3. motion artifact Correct answer.
    4. carbon monoxide poisoning

    Explanation

    Motion artifact is a common cause of erratic pulse oximetry and false desaturation because the probe cannot reliably distinguish pulsatile arterial signal from movement. Securing the probe and minimizing motion usually improves the reading.

  73. Question 73Troubleshooting and Quality Control of Equipment and Infection Control

    For suctioning an adult's airway, the vacuum regulator is typically set to:

    1. 80 to 120 mm Hg Correct answer.
    2. 60 to 80 mm Hg
    3. 140 to 160 mm Hg
    4. 20 to 40 mm Hg

    Explanation

    Adult airway suction is commonly performed with vacuum pressures of about 80 to 120 mm Hg. Higher pressures increase the risk of mucosal trauma and hypoxemia.

  74. Question 74Troubleshooting and Quality Control of Equipment and Infection Control

    Which patient is the best candidate for a heated humidifier rather than a heat-moisture exchanger?

    1. a patient with a dry but patent airway
    2. a patient with normal secretions on short-term ventilation
    3. a patient with copious thick secretions Correct answer.
    4. a patient being transported for 30 minutes

    Explanation

    A heated humidifier provides more water vapor and is preferred when secretions are thick or copious. An HME may add resistance and may not provide enough humidity in that situation.

  75. Question 75Troubleshooting and Quality Control of Equipment and Infection Control

    During a pre-use ventilator circuit check, the measured tidal volume is 400 mL while the set volume is 500 mL and the pressure waveform shows a slow rise. The most appropriate next step is to:

    1. recalibrate the oxygen sensor
    2. increase the set tidal volume to 600 mL
    3. check the circuit and humidifier connections for leaks Correct answer.
    4. lower the high-pressure alarm limit

    Explanation

    A delivered volume that is consistently below the set volume suggests gas loss from the circuit or humidifier. Checking connections and performing a leak test is the appropriate first step.

  76. Question 76Troubleshooting and Quality Control of Equipment and Infection Control

    A small-volume nebulizer produces little mist and the patient's bronchodilator response is poor. The device is powered by 6 L/min oxygen. Which action is most appropriate?

    1. place the nebulizer in line with the ventilator
    2. check the tubing for kinks and the jet for obstruction Correct answer.
    3. add more medication to the cup
    4. increase the oxygen flow to 15 L/min

    Explanation

    A gas flow of 6 L/min is generally adequate for a small-volume nebulizer, so poor output usually suggests an obstruction, kink, or faulty jet. The therapist should inspect the delivery system before changing the setup.

  77. Question 77Troubleshooting and Quality Control of Equipment and Infection Control

    A blood gas analyzer's daily quality control result falls outside 2 standard deviations on the Levey-Jennings chart. The therapist should first:

    1. calibrate the analyzer to the patient's sample
    2. report patient results and document the deviation
    3. switch to a different control level
    4. repeat the control with a new ampule and inspect reagents and electrodes Correct answer.

    Explanation

    A single control value outside 2 standard deviations may be random error, so the first step is to repeat the control and check reagents and electrodes. Patient results should not be reported until the analyzer is shown to be in control.

  78. Question 78Troubleshooting and Quality Control of Equipment and Infection Control

    On a Levey-Jennings chart, six consecutive quality control values fall on one side of the mean but within control limits. This pattern most likely indicates:

    1. normal variation requiring no action
    2. random error
    3. systematic error such as a drifting electrode Correct answer.
    4. a transcription error only

    Explanation

    A shift of multiple consecutive values to one side of the mean is a systematic pattern and suggests calibration drift, reagent problems, or electrode deterioration. Random error produces scatter without such a consistent shift.

  79. Question 79Troubleshooting and Quality Control of Equipment and Infection Control

    During mechanical ventilation, the capnography waveform suddenly falls from 38 to 12 mm Hg with no change in the ventilator settings. Which cause should be suspected first?

    1. a circuit leak or disconnection Correct answer.
    2. a malfunctioning oxygen analyzer
    3. increased cardiac output
    4. a rising body temperature

    Explanation

    A sudden fall in end-tidal CO2 can result from loss of exhaled gas from the sampling site, such as a leak or disconnection. It can also occur with a sudden drop in pulmonary blood flow, but the circuit should be checked first.

  80. Question 80Troubleshooting and Quality Control of Equipment and Infection Control

    Condensate has collected in the expiratory limb of a heated humidifier circuit and the patient's airway pressure is fluctuating. The appropriate action is to:

    1. replace the oxygen sensor
    2. drain the water trap and reposition the tubing Correct answer.
    3. increase the bias flow
    4. raise the humidifier temperature

    Explanation

    Condensate in the circuit can obstruct gas flow and cause pressure fluctuations or auto-triggering. Draining the water trap and positioning the tubing so condensate drains away from the patient corrects the problem.

  81. Question 81Troubleshooting and Quality Control of Equipment and Infection Control

    A ventilator's three-prong plug is connected to a cheater adapter that leaves the ground prong disconnected. The main hazard is that:

    1. the ventilator will deliver too much tidal volume
    2. the oxygen sensor will drift
    3. the chassis may become energized and shock the patient or staff Correct answer.
    4. the circuit will develop a leak

    Explanation

    The ground prong provides a low-resistance path for fault current. If the ground is defeated, a fault can energize the chassis and create a shock hazard.

  82. Question 82Troubleshooting and Quality Control of Equipment and Infection Control

    During volume-controlled ventilation, peak inspiratory pressure rises from 25 to 45 cm H2O while plateau pressure remains 20 cm H2O. This pattern indicates an increase in:

    1. lung compliance
    2. alveolar pressure
    3. chest wall compliance
    4. airway resistance Correct answer.

    Explanation

    The difference between peak and plateau pressure reflects the pressure needed to overcome airway resistance. A widening peak-to-plateau gradient with an unchanged plateau indicates increased resistance, such as from secretions or a kink.

  83. Question 83Troubleshooting and Quality Control of Equipment and Infection Control

    An air-entrainment mask is set to deliver 28% oxygen. If the air-entrainment ports become partially occluded, the delivered oxygen concentration will:

    1. fluctuate with the patient's tidal volume but average 28%
    2. decrease below 28%
    3. remain at 28%
    4. increase above 28% Correct answer.

    Explanation

    Air-entrainment devices dilute oxygen with room air through the entrainment ports. If those ports are occluded, less room air is entrained and the delivered oxygen concentration rises.

  84. Question 84Troubleshooting and Quality Control of Equipment and Infection Control

    After a bronchoscopy on a patient without known infection, the reusable bronchoscope should receive:

    1. wiping the insertion tube with alcohol only
    2. high-level disinfection after thorough cleaning Correct answer.
    3. rinsing with tap water and hanging to dry
    4. sterilization by dry heat

    Explanation

    Flexible bronchoscopes are semicritical items that require thorough cleaning followed by high-level disinfection, or sterilization if indicated. Dry heat would damage the instrument.

  85. Question 85Troubleshooting and Quality Control of Equipment and Infection Control

    A patient is admitted with a wound infected by methicillin-resistant Staphylococcus aureus. Which infection control measure is required?

    1. contact precautions with gloves and gown for room entry Correct answer.
    2. airborne precautions with a negative-pressure room
    3. droplet precautions with a surgical mask within 3 feet
    4. standard precautions only, with no additional barrier

    Explanation

    MRSA is spread primarily by direct and indirect contact, so contact precautions with gloves and gown are required for room entry. Airborne and droplet precautions are used for organisms spread by those routes.

  86. Question 86Troubleshooting and Quality Control of Equipment and Infection Control

    A patient with suspected active pulmonary tuberculosis is being transported from the emergency department. The RT should wear:

    1. an N95 respirator Correct answer.
    2. a surgical mask
    3. a face shield only
    4. a gown and gloves only

    Explanation

    Pulmonary tuberculosis is transmitted by airborne droplet nuclei, so an N95 respirator is required for respiratory protection. A surgical mask on the patient also helps contain droplets during transport.

  87. Question 87Troubleshooting and Quality Control of Equipment and Infection Control

    Which action best reduces the risk of ventilator-associated infection when condensate is present in the breathing circuit?

    1. drain the condensate away from the patient and discard it as infectious waste Correct answer.
    2. empty the condensate back into the humidifier
    3. leave the condensate in the tubing until the circuit is changed
    4. rinse the tubing with tap water

    Explanation

    Circuit condensate can become contaminated and should be drained away from the patient and discarded as infectious waste. Keeping the tubing positioned so condensate drains away from the airway reduces the risk of aspiration into the patient.

  88. Question 88Troubleshooting and Quality Control of Equipment and Infection Control

    During oxygen therapy from an H cylinder, frost forms on the regulator. The most likely cause is:

    1. a malfunctioning low-pressure alarm
    2. a cylinder leak at the valve stem
    3. rapid expansion of gas as it leaves the cylinder Correct answer.
    4. contamination of the oxygen supply

    Explanation

    Frost or condensation on a regulator is commonly caused by cooling as compressed gas expands rapidly during use. This is an expected physical effect and does not by itself indicate contamination.

  89. Question 89Troubleshooting and Quality Control of Equipment and Infection Control

    Before spirometry testing, a 3-L calibration syringe is used and the spirometer consistently reads 2.7 L. The appropriate response is to:

    1. test the patient and note the discrepancy
    2. recalibrate or repair the spirometer before testing Correct answer.
    3. use a smaller syringe to compensate
    4. accept the result because 10% error is allowed

    Explanation

    A 3-L syringe should produce a reading within about 3% of 3 L, so 2.7 L represents a 10% error and is unacceptable. The spirometer must be recalibrated or repaired before patient testing.

  90. Question 90Troubleshooting and Quality Control of Equipment and Infection Control

    Quality control results show alternating high and low values that are all within the control limits. This pattern most suggests:

    1. random error Correct answer.
    2. calibration drift
    3. systematic error
    4. a shift in the mean

    Explanation

    Random error produces scatter with values on both sides of the mean and no consistent pattern. Systematic error more often appears as a shift, trend, or values consistently on one side of the mean.

  91. Question 91Troubleshooting and Quality Control of Equipment and Infection Control

    After manual ventilation of a patient, a reusable bag-valve device is visibly contaminated with blood. The correct reprocessing step is to:

    1. discard it in regular trash without further handling
    2. wipe it with an alcohol pad and return it to the shelf
    3. rinse it with tap water and dry it
    4. clean it with detergent, then high-level disinfect or sterilize according to the manufacturer's instructions Correct answer.

    Explanation

    Visible blood contamination requires thorough cleaning before high-level disinfection or sterilization, following the manufacturer's instructions. Cleaning removes organic material that can prevent the disinfectant from working.

  92. Question 92Troubleshooting and Quality Control of Equipment and Infection Control

    A medical gas cylinder is marked with a green shoulder in the United States. This cylinder most likely contains:

    1. Oxygen Correct answer.
    2. Yellow
    3. Blue
    4. Gray

    Explanation

    In the United States, the cylinder color code uses green for oxygen, yellow for air, blue for nitrous oxide, and gray for carbon dioxide. Color is only a secondary check because the pin-index system is the primary safety feature.

  93. Question 93Troubleshooting and Quality Control of Equipment and Infection Control

    When should a respiratory therapist perform hand hygiene during patient care?

    1. Only before contact
    2. Before and after contact Correct answer.
    3. Only when visibly soiled
    4. Only after removing gloves

    Explanation

    Hand hygiene is required before and after every patient contact and after removing gloves. It also is required after contact with blood, body fluids, or contaminated equipment.

  94. Question 94Troubleshooting and Quality Control of Equipment and Infection Control

    A suction catheter is being selected for a patient with a 7.0-mm internal diameter endotracheal tube. The catheter's outer diameter should be no larger than:

    1. 5.0 mm
    2. 7.0 mm
    3. 1.75 mm
    4. 3.5 mm Correct answer.

    Explanation

    The outer diameter of a suction catheter should not exceed half the internal diameter of the endotracheal tube. This limits airway occlusion and mucosal trauma during suctioning. For a 7.0-mm tube, the maximum catheter outer diameter is 3.5 mm.

  95. Question 95Troubleshooting and Quality Control of Equipment and Infection Control

    An E cylinder contains 660 L of oxygen at 2000 psi. The cylinder gauge reads 1000 psi and the flowmeter is set at 6 L/min. The approximate duration of flow is:

    1. 55 minutes Correct answer.
    2. 20 minutes
    3. 45 minutes
    4. 30 minutes

    Explanation

    At 1000 psi, the remaining volume is half of 660 L, or 330 L. Dividing 330 L by 6 L/min gives about 55 minutes of flow.

  96. Question 96Troubleshooting and Quality Control of Equipment and Infection Control

    When reading a Thorpe tube flowmeter with a ball float, the flow should be read at the:

    1. Any point on the scale
    2. Top edge of the float
    3. Center of the float Correct answer.
    4. Bottom edge of the float

    Explanation

    For a ball float, the flow is read at the center of the ball. For other float designs, the manufacturer's instructions identify the reference point.

  97. Question 97Troubleshooting and Quality Control of Equipment and Infection Control

    A small-volume nebulizer is being filled for a patient. Which fluid is appropriate?

    1. Distilled water from an open container
    2. Bottled drinking water
    3. Tap water
    4. Sterile water Correct answer.

    Explanation

    Sterile water or sterile saline should be used in nebulizers to reduce the risk of introducing microorganisms into the airway. Tap water and opened containers are not sterile.

  98. Question 98Troubleshooting and Quality Control of Equipment and Infection Control

    Standard precautions should be applied to:

    1. All patients regardless of diagnosis Correct answer.
    2. Only patients with a known infection
    3. Only patients in isolation
    4. Only patients with bloodborne pathogens

    Explanation

    Standard precautions apply to all patients because infection status may be unknown. They include hand hygiene, gloves, gowns, masks, and safe handling of sharps.

  99. Question 99Troubleshooting and Quality Control of Equipment and Infection Control

    A pulse oximeter reading is unexpectedly low, and the patient has thick nail polish on the monitored finger. The most appropriate action is to:

    1. Remove polish or use an alternate site Correct answer.
    2. Ignore because polish does not affect reading
    3. Increase the alarm sensitivity
    4. Apply the probe more tightly

    Explanation

    Nail polish and artificial nails can interfere with light transmission and produce an inaccurate reading. Removing the polish or using an alternate site improves accuracy.

  100. Question 100Troubleshooting and Quality Control of Equipment and Infection Control

    During volume-controlled ventilation, the high-pressure alarm sounds and the peak inspiratory pressure is 45 cm H2O. The patient is biting the endotracheal tube. The appropriate initial action is to:

    1. Suction the airway
    2. Increase the tidal volume
    3. Decrease the alarm limit
    4. Insert a bite block Correct answer.

    Explanation

    Biting occludes the endotracheal tube and raises peak pressure. Inserting an oral airway or bite block relieves the obstruction; the alarm limit should not be changed to silence a real problem.

  101. Question 101Troubleshooting and Quality Control of Equipment and Infection Control

    A ventilator's low-pressure alarm sounds. Which of the following is the most likely cause?

    1. Circuit disconnect Correct answer.
    2. Retained secretions
    3. Bronchospasm
    4. Patient biting

    Explanation

    A circuit disconnect allows gas to escape and causes loss of airway pressure, triggering the low-pressure alarm. Secretions, bronchospasm, and biting increase resistance and typically trigger the high-pressure alarm.

  102. Question 102Troubleshooting and Quality Control of Equipment and Infection Control

    A patient receiving volume-controlled ventilation has an inspired tidal volume of 500 mL and an exhaled tidal volume of 350 mL. Peak inspiratory pressure is normal. The most likely cause is:

    1. Decreased lung compliance
    2. Retained secretions
    3. Auto-PEEP
    4. Circuit leak Correct answer.

    Explanation

    A leak in the ventilator circuit or around the endotracheal tube cuff allows gas to escape, so exhaled volume is less than delivered volume. Secretions and decreased compliance raise pressure rather than reduce exhaled volume.

  103. Question 103Troubleshooting and Quality Control of Equipment and Infection Control

    To reduce contamination of the ventilator and the environment, a HEPA filter is commonly placed on the:

    1. Between the humidifier and the patient
    2. At the oxygen inlet
    3. Expiratory limb Correct answer.
    4. Inspiratory limb

    Explanation

    An expiratory-limb HEPA filter captures microorganisms exhaled by the patient before gas returns to the ventilator or room. An inspiratory filter protects the patient from contaminated gas but does not serve the same environmental purpose.

  104. Question 104Troubleshooting and Quality Control of Equipment and Infection Control

    Water accumulates in the water trap of an air compressor supplying a ventilator. The appropriate action is to:

    1. Replace the compressor motor
    2. Add lubricating oil
    3. Increase driving pressure
    4. Drain the water trap Correct answer.

    Explanation

    Condensate must be drained from the water trap to prevent moisture from reaching the ventilator and to maintain gas flow. Oil should never be added to a medical air compressor system.

  105. Question 105Troubleshooting and Quality Control of Equipment and Infection Control

    An oxygen concentrator's low-oxygen alarm sounds and the delivered oxygen concentration is 70% instead of the expected 90% or higher. The most appropriate action is to:

    1. Ignore because 70% is adequate
    2. Check the sieve beds Correct answer.
    3. Increase the flow setting
    4. Add a humidifier

    Explanation

    A low oxygen concentration from a concentrator suggests a problem with the sieve beds, connections, or internal components. The patient should be placed on a backup oxygen source while the device is evaluated.

  106. Question 106Troubleshooting and Quality Control of Equipment and Infection Control

    A colorimetric carbon dioxide detector changes from purple to yellow after endotracheal intubation. This indicates:

    1. No CO2 is present
    2. Exhaled CO2 is present Correct answer.
    3. The patient has a pneumothorax
    4. The detector is expired

    Explanation

    The color change from purple to yellow indicates the presence of exhaled carbon dioxide, supporting tracheal tube placement. Absence of color change suggests esophageal placement or absent pulmonary perfusion.

  107. Question 107Troubleshooting and Quality Control of Equipment and Infection Control

    An oxygen analyzer is being calibrated before use. The two-point calibration should use:

    1. 21% and 100% Correct answer.
    2. 0% and 100%
    3. 50% and 100%
    4. 21% and 50%

    Explanation

    Oxygen analyzers are typically calibrated at room air, approximately 21%, and at 100% oxygen. This verifies accuracy across the clinically relevant range.

  108. Question 108Troubleshooting and Quality Control of Equipment and Infection Control

    The proximal airway temperature of a heated humidifier reads 41°C. The appropriate action is to:

    1. Add water to the chamber
    2. Check the probe and heater Correct answer.
    3. Ignore because 41°C is normal
    4. Increase inspiratory flow

    Explanation

    A proximal airway temperature of 41°C is above the usual target of about 37°C and can injure the airway. The temperature probe and heater should be checked, and the heater setting reduced.

  109. Question 109Troubleshooting and Quality Control of Equipment and Infection Control

    Seven consecutive quality control results show a progressive rise but remain within control limits. This pattern most likely represents:

    1. Systematic drift Correct answer.
    2. Random error
    3. A transcription error
    4. Acceptable precision

    Explanation

    A progressive rise across consecutive control results indicates a trend or drift, which is a systematic error. The cause should be investigated even though individual values remain within limits.

  110. Question 110Troubleshooting and Quality Control of Equipment and Infection Control

    After replacing an electrode in a blood gas analyzer, the technologist should first:

    1. Run only a one-point QC
    2. Run a patient sample
    3. Change the electrode again
    4. Calibrate, then run QC Correct answer.

    Explanation

    A new electrode must be calibrated before quality control is evaluated. After calibration and acceptable QC, patient samples may be analyzed.

  111. Question 111Troubleshooting and Quality Control of Equipment and Infection Control

    A reusable ventilator circuit is being processed between patients. The most appropriate method is:

    1. Wipe with alcohol and reuse immediately
    2. Rinse with tap water and hang to dry
    3. High-level disinfection per manufacturer Correct answer.
    4. Store in a closed cabinet without processing

    Explanation

    Reusable ventilator circuits require high-level disinfection or sterilization according to the manufacturer's instructions. Rinsing with tap water or wiping with alcohol does not provide adequate reprocessing.

  112. Question 112Troubleshooting and Quality Control of Equipment and Infection Control

    A non-compensated Thorpe tube flowmeter is delivering oxygen through a nebulizer with a partial downstream obstruction. The flow indicated on the flowmeter will be:

    1. Equal to the actual flow
    2. Unaffected by the obstruction
    3. Higher than the actual flow Correct answer.
    4. Lower than the actual flow

    Explanation

    A non-compensated Thorpe tube is calibrated at atmospheric pressure. Back pressure from the obstruction reduces actual flow, so the indicated flow is higher than the flow actually delivered.

  113. Question 113Troubleshooting and Quality Control of Equipment and Infection Control

    During a pre-use check of a manual resuscitator, the bag fails to refill after being squeezed and the patient valve appears intact. The most likely cause is:

    1. Normal function
    2. A stiff patient lung
    3. A faulty inlet valve Correct answer.
    4. A full oxygen reservoir

    Explanation

    The bag refills when gas enters through the inlet valve. If that valve sticks closed or malfunctions, the bag cannot refill and the device should be removed from service.

  114. Question 114Troubleshooting and Quality Control of Equipment and Infection Control

    A spirometer passes its 3-L syringe calibration check, but the biological control shows an FVC 15% lower than the previous value. The most appropriate action is to:

    1. Report the value as a patient result
    2. Recalibrate with a 1-L syringe
    3. Investigate and repeat the control Correct answer.
    4. Accept because the syringe check passed

    Explanation

    A change in the biological control suggests a problem that the syringe check may not detect, such as a leak or software issue. The equipment should be investigated and the control repeated before patient testing.

  115. Question 115Troubleshooting and Quality Control of Equipment and Infection Control

    Before extubation, a cuff leak test shows no audible leak when the endotracheal tube cuff is deflated. This finding most likely indicates:

    1. The cuff is ruptured
    2. Ready for immediate extubation
    3. Laryngeal edema Correct answer.
    4. The tube is too small

    Explanation

    Absence of a cuff leak may indicate laryngeal edema or a tube that is too large for the airway. This increases the risk of post-extubation stridor and requires further assessment.

  116. Question 116Troubleshooting and Quality Control of Equipment and Infection Control

    Endotracheal tube cuff pressure should generally be maintained at:

    1. 10 to 15 cm H2O
    2. 30 to 40 cm H2O
    3. 5 to 10 cm H2O
    4. 20 to 30 cm H2O Correct answer.

    Explanation

    Cuff pressure should be high enough to seal the airway but below about 30 cm H2O to avoid compromising tracheal mucosal blood flow. Pressures of 20 to 30 cm H2O are commonly targeted.

  117. Question 117Troubleshooting and Quality Control of Equipment and Infection Control

    A respiratory therapist moves from one patient to the next in a busy unit. According to standard precautions, hand hygiene with an alcohol-based rub or soap and water is required:

    1. only when the hands are visibly soiled with blood or body fluids
    2. before and after contact with each patient Correct answer.
    3. at the start of each shift and after work breaks
    4. only after contact with a patient who has a known infection

    Explanation

    Hand hygiene must be performed before and after every patient contact, regardless of whether gloves were worn, because transient organisms picked up from one patient can be carried to the next. Gloves reduce but do not eliminate hand contamination, so they never replace hand hygiene.

  118. Question 118Troubleshooting and Quality Control of Equipment and Infection Control

    A patient with suspected pulmonary tuberculosis is being admitted to a respiratory care unit. Which room placement is appropriate?

    1. A private room with the door left open to the hallway
    2. A semiprivate room with a curtain drawn between the beds
    3. A positive-pressure room with HEPA-filtered supply air
    4. A negative-pressure room with at least 6 air changes per hour Correct answer.

    Explanation

    Suspected or confirmed pulmonary tuberculosis requires airborne precautions, which means an airborne infection isolation room with the door closed, negative pressure relative to the corridor, and a defined number of air changes per hour (at least 6 in existing rooms). Air is exhausted or HEPA-filtered before recirculation, and caregivers wear a fit-tested N95 or higher respirator.

  119. Question 119Troubleshooting and Quality Control of Equipment and Infection Control

    A flexible bronchoscope has been used for a procedure and will be reprocessed for another patient. Because the device contacts mucous membranes, the minimum acceptable level of reprocessing is:

    1. steam sterilization at 121°C in a gravity displacement autoclave
    2. cleaning with an enzymatic detergent only
    3. low-level disinfection with a quaternary ammonium compound
    4. high-level disinfection Correct answer.

    Explanation

    Items that contact intact mucous membranes without entering sterile tissue are classified as semicritical and require high-level disinfection after thorough cleaning. High-level disinfection destroys all vegetative bacteria, mycobacteria, fungi, and most viruses but does not necessarily kill bacterial spores.

  120. Question 120Troubleshooting and Quality Control of Equipment and Infection Control

    A respiratory therapist is placing a newly delivered ventilator at the bedside. Which practice is appropriate when making the electrical connection?

    1. Using a two-prong cheater adapter when no grounded outlet is free
    2. Routing the power cord across the floor under the patient's bed
    3. Sharing one extension cord with a refrigerator to reduce cord clutter
    4. Plugging the power cord directly into a properly grounded receptacle Correct answer.

    Explanation

    Equipment must be connected to a properly grounded three-wire receptacle so that any fault current is diverted to ground rather than through the patient or caregiver. Adapters that defeat the ground, overloaded extension cords, and cords that can be crushed or tripped over increase the risk of shock and fire.

  121. Question 121Troubleshooting and Quality Control of Equipment and Infection Control

    Which practice is required when storing and handling oxygen cylinders in a respiratory care department?

    1. Securing the cylinder upright and keeping it away from heat and grease Correct answer.
    2. Leaving the cylinder valve partially open between patient uses
    3. Applying petroleum jelly to the regulator threads before attaching it
    4. Storing cylinders lying flat in a closed closet near the furnace room

    Explanation

    Cylinders must be secured upright to prevent them from falling and shearing the valve, and they must be kept away from heat, open flame, and any oil or grease. Oxygen supports combustion, and hydrocarbons combined with high-pressure oxygen can ignite.

  122. Question 122Troubleshooting and Quality Control of Equipment and Infection Control

    A department disinfects reusable respiratory therapy equipment by pasteurization. The correct exposure parameters are:

    1. 70°C for 30 minutes Correct answer.
    2. 121°C at 15 psi for 15 minutes
    3. 100°C for 5 minutes
    4. 60°C for 10 minutes

    Explanation

    Pasteurization is a high-level disinfection process that exposes equipment to water at 70°C (158°F) for 30 minutes. Treated items must then be dried and stored in a way that prevents recontamination, because the process does not destroy bacterial spores.

  123. Question 123Troubleshooting and Quality Control of Equipment and Infection Control

    Six consecutive quality control values for a blood gas analyzer fall on the same side of the mean but remain within the ±2 SD limits. This pattern should be interpreted as:

    1. a trend caused by deterioration of the control material
    2. a systematic shift that requires investigation before reporting results Correct answer.
    3. proof that the analyzer is in control because no point exceeds limits
    4. random error that can be ignored if the values are within limits

    Explanation

    Six or more consecutive points on one side of the mean describe a shift, which signals systematic error such as calibration drift, a deteriorating electrode, or a change in reagent. Because the bias is real even though individual points are within limits, the cause must be found before patient results are reported.

  124. Question 124Troubleshooting and Quality Control of Equipment and Infection Control

    Before analyzing patient samples, a blood gas analyzer performs a two-point calibration. This step uses:

    1. two gases with known, different CO2 and O2 concentrations Correct answer.
    2. room air and one high-oxygen gas
    3. three control materials at low, normal, and high levels
    4. a single gas mixture chosen by the operator

    Explanation

    A two-point calibration establishes the response curve of the electrodes using two gases that bracket the expected patient range, one containing little or no CO2 with a low PO2 and one with higher CO2 and PO2. Control materials are analyzed after calibration to verify performance rather than to set the calibration.

  125. Question 125Troubleshooting and Quality Control of Equipment and Infection Control

    A heparinized arterial blood sample is found to contain a visible air bubble when it arrives in the laboratory. Compared with the patient's true values, the result will most likely show:

    1. decreased PCO2 and decreased PO2
    2. increased PCO2 and decreased PO2
    3. decreased PCO2 and increased PO2 Correct answer.
    4. no change in PCO2 or PO2 with a falsely low pH

    Explanation

    Gas in the bubble equilibrates with the blood: carbon dioxide leaves the sample and oxygen enters it, so PCO2 falls and PO2 rises. This preanalytical error also tends to raise the measured pH.

  126. Question 126Troubleshooting and Quality Control of Equipment and Infection Control

    An air-oxygen blender supplies a ventilator. The pipeline air source fails while the oxygen source remains at normal pressure. The blender will most likely:

    1. deliver close to 100% oxygen and activate an alarm Correct answer.
    2. stop all gas flow to the patient until air pressure returns
    3. continue at the set FiO2 until the oxygen supply is depleted
    4. deliver 21% oxygen and sound a low-pressure alarm

    Explanation

    When the air supply is lost, the blender's balance mechanism defaults so that oxygen passes through, and the delivered concentration rises toward 100% with a simultaneous alarm. The therapist must recognize this fail-safe behavior and monitor the patient for oxygen toxicity while the air source is restored.

  127. Question 127Troubleshooting and Quality Control of Equipment and Infection Control

    During suctioning, vacuum at the catheter tip suddenly drops. The canister is nearly full of secretions. The most appropriate immediate action is:

    1. instill sterile water through the catheter and continue suctioning
    2. switch to a larger-diameter suction catheter
    3. replace the full canister with an empty one and recheck vacuum Correct answer.
    4. increase the regulator setting to its maximum

    Explanation

    Suction canisters contain a float or shut-off valve that rises when the canister is full and blocks the vacuum, which causes the sudden loss of suction. Emptying or replacing the canister restores vacuum without exposing the patient to excessive negative pressure.

  128. Question 128Troubleshooting and Quality Control of Equipment and Infection Control

    A capnograph suddenly displays no waveform, although the patient is clinically stable and the ventilator readings are unchanged. Moisture is visible in the sample tubing. The most likely cause is:

    1. an obstructed sample line caused by condensation Correct answer.
    2. hyperventilation by the patient
    3. cardiac oscillation artifact on the tracing
    4. a leak around the endotracheal tube cuff

    Explanation

    Condensation or secretions can block the sampling line or the water trap, so the analyzer receives no gas and the tracing disappears even though ventilation is adequate. The line or trap should be cleared or replaced while the patient's oxygenation and ventilation are assessed.

  129. Question 129Troubleshooting and Quality Control of Equipment and Infection Control

    Condensate has collected in the inspiratory limb of a heated ventilator circuit. The appropriate action is:

    1. drain the fluid away from the patient and discard it Correct answer.
    2. raise the humidifier temperature until the fluid evaporates
    3. drain the fluid back into the humidifier chamber
    4. leave the fluid in the tubing until the next circuit change

    Explanation

    Condensate should be drained through the water traps so that it flows away from the patient, and the fluid is discarded because it is a contaminated reservoir. Returning it to the humidifier or leaving it in the circuit risks delivery of contaminated water into the airway and can cause a sudden obstruction or drowning of the tubing.

  130. Question 130Troubleshooting and Quality Control of Equipment and Infection Control

    To protect a patient with an indwelling intracardiac catheter from microshock, the maximum allowable leakage current for equipment connected to that patient is:

    1. 500 microamperes
    2. 100 microamperes
    3. 1 milliampere
    4. 10 microamperes Correct answer.

    Explanation

    Conductive pathways that reach the heart, such as fluid-filled catheters or pacing leads, lower the fibrillation threshold dramatically, so leakage current for patient-connected equipment is limited to about 10 microamperes. Chassis leakage for ordinary equipment is allowed to be higher, around 100 microamperes.

  131. Question 131Troubleshooting and Quality Control of Equipment and Infection Control

    Equipment sterilized with ethylene oxide must be aerated before use because:

    1. aeration removes moisture that would promote bacterial growth
    2. air exposure completes the sporicidal action of the gas
    3. absorbed ethylene oxide can injure the patient's tissues Correct answer.
    4. aeration restores the electrical conductivity of the device

    Explanation

    Ethylene oxide is a toxic, mutagenic gas that is absorbed by plastics, rubber, and other porous materials and then slowly desorbs. Aeration removes the residual gas so that the device does not release irritating or toxic amounts into the patient's tissues.

  132. Question 132Troubleshooting and Quality Control of Equipment and Infection Control

    A heat-and-moisture exchanger (HME) is in place on a patient receiving continuous nebulized bronchodilator therapy through the ventilator circuit. The therapist should remove the HME because:

    1. the HME will dry the inspired gas excessively
    2. the HME will add excessive heat to the inspired gas
    3. the aerosol can clog the HME and increase resistance to breathing Correct answer.
    4. the nebulizer cannot generate an aerosol against HME resistance

    Explanation

    Aerosol particles and added water can saturate and occlude the HME media, raising inspiratory resistance and delivering an unpredictable dose of medication. Continuous nebulization therefore calls for an active heated humidifier or removal of the HME during therapy, with resistance monitored.

  133. Question 133Initiation and Modification of Therapeutic Interventions

    Which arterial blood gas result most clearly indicates that supplemental oxygen should be started?

    1. PaO2 of 78 mm Hg
    2. PaO2 of 55 mm Hg Correct answer.
    3. PaO2 of 92 mm Hg
    4. PaO2 of 66 mm Hg

    Explanation

    Oxygen therapy is indicated when PaO2 falls below 60 mm Hg or SpO2 falls below 90%, which corresponds to the steep portion of the oxyhemoglobin dissociation curve where saturation drops rapidly.

  134. Question 134Initiation and Modification of Therapeutic Interventions

    A patient using a metered-dose inhaler without a spacer should be instructed to:

    1. actuate at the start of a slow, deep breath and hold it 10 seconds Correct answer.
    2. actuate the canister, then inhale as rapidly as possible
    3. actuate the canister and exhale fully through the mouthpiece
    4. actuate the canister 5 seconds before starting to inhale

    Explanation

    Proper MDI technique coordinates actuation with the beginning of a slow, deep inspiration followed by an approximately 10-second breath hold so particles can deposit in the lower airways.

  135. Question 135Initiation and Modification of Therapeutic Interventions

    Which device can deliver gas at 37 degrees C with 100% relative humidity?

    1. Unheated large-volume nebulizer
    2. Heat-and-moisture exchanger
    3. Heated passover humidifier Correct answer.
    4. Unheated bubble humidifier

    Explanation

    A heated passover humidifier adds both heat and water vapor, allowing it to reach body temperature with 100% relative humidity, which is the definition of body humidity.

  136. Question 136Initiation and Modification of Therapeutic Interventions

    When suctioning an adult's artificial airway, each pass of the catheter should last no longer than:

    1. 5 seconds
    2. 30 seconds
    3. 20 seconds
    4. 10 seconds Correct answer.

    Explanation

    Suctioning is limited to about 10 seconds per pass in adults because longer periods promote hypoxemia, atelectasis, and vagally mediated bradycardia.

  137. Question 137Initiation and Modification of Therapeutic Interventions

    The primary goal of incentive spirometry is to:

    1. increase forced expiratory flow rates
    2. strengthen the diaphragm against resistance
    3. mobilize secretions out of the airways
    4. sustain a maximal inspiration with a breath hold Correct answer.

    Explanation

    Incentive spirometry is a sustained maximal inspiration maneuver designed to prevent or reverse atelectasis by re-expanding alveoli and holding them open for several seconds.

  138. Question 138Initiation and Modification of Therapeutic Interventions

    Which maximal inspiratory pressure (MIP) value is consistent with readiness to wean?

    1. +15 cm H2O
    2. -10 cm H2O
    3. -5 cm H2O
    4. -25 cm H2O Correct answer.

    Explanation

    A MIP more negative than about -20 to -25 cm H2O indicates adequate inspiratory muscle strength for weaning, while values closer to zero reflect weakness.

  139. Question 139Initiation and Modification of Therapeutic Interventions

    Which order represents bland aerosol therapy?

    1. Racemic epinephrine by hand-held nebulizer
    2. Albuterol 2.5 mg by small-volume nebulizer
    3. Budesonide by metered-dose inhaler
    4. 0.9% sodium chloride by large-volume nebulizer Correct answer.

    Explanation

    Bland aerosol therapy delivers sterile water or saline without a pharmacologic agent, most often through a large-volume nebulizer, to humidify the airway and loosen secretions.

  140. Question 140Initiation and Modification of Therapeutic Interventions

    Which oxygen delivery device provides the most predictable fraction of inspired oxygen?

    1. Air-entrainment mask set at 35% Correct answer.
    2. Simple mask at 8 L/min
    3. Nonrebreather mask at 12 L/min
    4. Nasal cannula at 4 L/min

    Explanation

    Air-entrainment (Venturi) masks use a fixed jet-and-port design that entrains a constant ratio of room air, so the delivered oxygen concentration remains stable despite changes in flow or the patient's breathing pattern.

  141. Question 141Initiation and Modification of Therapeutic Interventions

    A patient with COPD has an SpO2 of 84%, and the protocol target range is 88% to 92%. What should you do first?

    1. Start nasal cannula at 1 to 2 L/min and titrate to target Correct answer.
    2. Start oxygen at 6 L/min by nasal cannula
    3. Withhold oxygen until an arterial blood gas is drawn
    4. Apply a nonrebreather mask at 15 L/min

    Explanation

    In patients with chronic hypercapnia, oxygen is titrated cautiously to an SpO2 of 88% to 92%, beginning with a low nasal cannula flow and increasing until the target is reached.

  142. Question 142Initiation and Modification of Therapeutic Interventions

    During a continuous albuterol nebulization, which finding should prompt you to modify the therapy?

    1. Peak flow improving by 15%
    2. SpO2 rising from 90% to 94%
    3. Cough during the first 10 minutes
    4. Heart rate rising from 92 to 128 beats/min Correct answer.

    Explanation

    Beta-2 agonists cause dose-related tachycardia and tremor; a marked heart rate increase (commonly beyond 120 beats/min or a rise of 20 beats/min) warrants slowing, interrupting, or changing the treatment and notifying the provider.

  143. Question 143Initiation and Modification of Therapeutic Interventions

    A ventilated patient on FiO2 0.40 has a PaO2 of 52 mm Hg and SpO2 of 86%. What is the most appropriate initial change?

    1. Decrease the inspiratory time
    2. Decrease the FiO2 to 0.35
    3. Increase the FiO2 to 0.50 Correct answer.
    4. Increase PEEP to 15 cm H2O

    Explanation

    With significant hypoxemia on a moderate FiO2, the first step is a modest increase in FiO2 to raise alveolar oxygen tension, then reassess with a repeat blood gas before making larger changes.

  144. Question 144Initiation and Modification of Therapeutic Interventions

    A patient on volume-control ventilation has a pH of 7.52 and a PaCO2 of 28 mm Hg. Which change is most appropriate?

    1. Increase the tidal volume by 100 mL
    2. Decrease the set respiratory rate Correct answer.
    3. Add 5 cm H2O of PEEP
    4. Increase the set respiratory rate

    Explanation

    The blood gas shows respiratory alkalosis from excessive alveolar ventilation, so reducing the set rate lowers minute ventilation and allows PaCO2 to rise back toward normal.

  145. Question 145Initiation and Modification of Therapeutic Interventions

    A patient on pressure support has a spontaneous rate of 32 breaths/min and an average tidal volume of 0.30 L. What is the rapid shallow breathing index and what does it indicate?

    1. About 96, suggesting weaning success is likely
    2. About 32, suggesting weaning success is likely
    3. About 107, suggesting weaning failure is likely Correct answer.
    4. About 10.7, suggesting weaning failure is likely

    Explanation

    The RSBI is the spontaneous respiratory rate divided by tidal volume in liters (32 divided by 0.30), which equals about 107; a value above 105 predicts weaning failure.

  146. Question 146Initiation and Modification of Therapeutic Interventions

    A patient with severe obstructive sleep apnea is 2 hours postoperative, drowsy, and having recurrent desaturations. CPAP is prescribed. What should you do?

    1. Substitute a simple mask at 6 L/min
    2. Wait until the patient is fully awake to apply therapy
    3. Apply CPAP at the prescribed pressure and monitor closely Correct answer.
    4. Substitute hourly incentive spirometry

    Explanation

    Early postoperative CPAP maintains upper airway patency and treats the obstruction causing desaturation; delaying therapy in a drowsy patient with recurrent hypoxemia risks worsening hypercapnia and airway obstruction.

  147. Question 147Initiation and Modification of Therapeutic Interventions

    Tracheostomy tube cuff pressure should generally be maintained at approximately:

    1. 5 to 10 cm H2O
    2. 20 to 25 cm H2O Correct answer.
    3. 40 to 50 cm H2O
    4. 60 to 70 cm H2O

    Explanation

    Cuff pressure is kept at the lowest level that seals the airway, generally about 20 to 25 cm H2O, to prevent aspiration while avoiding tracheal mucosal ischemia.

  148. Question 148Initiation and Modification of Therapeutic Interventions

    Which set of settings is typical when starting high-flow nasal cannula therapy in an adult?

    1. Flow 15 L/min, FiO2 1.00, temperature 31 degrees C
    2. Flow 5 L/min, FiO2 0.21, temperature 34 degrees C
    3. Flow 40 L/min, FiO2 titrated, 34 to 37 degrees C Correct answer.
    4. Flow 60 L/min, FiO2 0.21, temperature 37 degrees C

    Explanation

    High-flow nasal cannula is typically started at flows of about 30 to 60 L/min with the FiO2 titrated to the saturation target and the temperature set between 34 and 37 degrees C for comfort and humidification.

  149. Question 149Initiation and Modification of Therapeutic Interventions

    Which position is used for postural drainage of the right middle lobe?

    1. Left side lying with the head down about 15 degrees Correct answer.
    2. Sitting upright and leaning forward
    3. Right side lying with the head down about 30 degrees
    4. Prone with the foot of the bed elevated

    Explanation

    The right middle lobe bronchus arises anteriorly, so drainage is achieved by lying on the left side with the head elevated only slightly downward, allowing gravity to move secretions toward the central airway.

  150. Question 150Initiation and Modification of Therapeutic Interventions

    During suctioning, a patient's heart rate falls from 82 to 44 beats/min and SpO2 drops. What is the best action?

    1. Increase the suction pressure and reinsert
    2. Insert the catheter deeper to reach secretions
    3. Continue for the remaining 5 seconds to finish clearing
    4. Stop suctioning, oxygenate the patient, and monitor Correct answer.

    Explanation

    Bradycardia during suctioning reflects vagal stimulation and hypoxemia; the procedure must be stopped immediately, the patient oxygenated and hyperoxygenated, and vital signs rechecked before any further attempt.

  151. Question 151Initiation and Modification of Therapeutic Interventions

    A patient on volume-control ventilation shows air hunger and accessory muscle use, with the airway pressure dropping below baseline early in each inspiration. What change is most appropriate?

    1. Decrease the set respiratory rate
    2. Decrease the inspiratory flow rate
    3. Increase the inspiratory flow rate Correct answer.
    4. Increase the set tidal volume

    Explanation

    These findings indicate flow starvation, in which the patient's inspiratory demand exceeds the set flow; increasing the peak flow or changing the flow waveform better matches demand and relieves the asynchrony.

  152. Question 152Initiation and Modification of Therapeutic Interventions

    A patient with severe arthritis cannot coordinate actuation and inhalation with a metered-dose inhaler. What is the best modification?

    1. Have the patient inhale through the nose instead
    2. Switch to a small-volume nebulizer with the same drug
    3. Increase the dose to two puffs per treatment
    4. Add a valved holding chamber to the inhaler Correct answer.

    Explanation

    A valved holding chamber removes the need to coordinate actuation with inhalation, so the patient can breathe slowly from the chamber and still receive adequate lung deposition.

  153. Question 153Initiation and Modification of Therapeutic Interventions

    A patient with ARDS on volume-control ventilation has FiO2 0.80, PEEP 8 cm H2O, PaO2 58 mm Hg, and a plateau pressure of 28 cm H2O. What is the best next intervention?

    1. Increase PEEP while monitoring plateau pressure Correct answer.
    2. Increase FiO2 to 1.00 and keep it there
    3. Decrease PEEP to 5 cm H2O to protect the lung
    4. Increase tidal volume to 8 mL/kg predicted body weight

    Explanation

    With hypoxemia persisting despite a high FiO2, the appropriate step is to raise PEEP to recruit collapsed alveoli while keeping plateau pressure within a lung-protective limit, generally at or below 30 cm H2O.

  154. Question 154Initiation and Modification of Therapeutic Interventions

    Twenty minutes into a spontaneous breathing trial the patient has a respiratory rate of 38 breaths/min, diaphoresis, and SpO2 of 86%. What is the best action?

    1. Return to the previous ventilator settings and investigate the cause Correct answer.
    2. Continue the trial to complete the full 30 minutes
    3. Increase pressure support to 20 cm H2O and continue
    4. Extubate and apply a nasal cannula at 2 L/min

    Explanation

    Tachypnea, diaphoresis, and desaturation are signs of SBT failure; the trial should be stopped and ventilatory support restored while the cause (secretions, fluid overload, weakness, pain) is identified.

  155. Question 155Initiation and Modification of Therapeutic Interventions

    A ventilated patient with severe asthma has a measured total PEEP of 12 cm H2O, a set PEEP of 5 cm H2O, and new hypotension. Which change is most appropriate?

    1. Increase the respiratory rate to lower PaCO2
    2. Decrease the respiratory rate to allow longer exhalation Correct answer.
    3. Increase the tidal volume to improve ventilation
    4. Add another 5 cm H2O of PEEP

    Explanation

    The difference between total and set PEEP indicates dynamic hyperinflation; slowing the rate lengthens expiratory time, reduces air trapping, and improves venous return and blood pressure.

  156. Question 156Initiation and Modification of Therapeutic Interventions

    A patient has received FiO2 1.00 for 30 hours and now has a PaO2 of 150 mm Hg with stable hemodynamics and SpO2 of 99%. What is the best action?

    1. Maintain FiO2 1.00 and recheck the gas in 12 hours
    2. Keep FiO2 at 1.00 so PaO2 stays above 100 mm Hg
    3. Increase PEEP to 20 cm H2O
    4. Titrate FiO2 down to keep PaO2 near 60 mm Hg Correct answer.

    Explanation

    Prolonged exposure to a high FiO2 causes oxygen toxicity and absorption atelectasis, so the FiO2 should be reduced to the lowest level that maintains adequate oxygenation, generally a PaO2 of about 60 mm Hg or an SpO2 of 88% to 95%.

  157. Question 157Initiation and Modification of Therapeutic Interventions

    Thirty minutes after extubation, a patient develops inspiratory stridor and increased work of breathing. What is the best initial action?

    1. Begin hourly incentive spirometry and continue monitoring
    2. Provide cool humidified oxygen with racemic epinephrine and notify the provider Correct answer.
    3. Apply a nonrebreather at 15 L/min and reassess in 1 hour
    4. Reintubate immediately without any other intervention

    Explanation

    Post-extubation stridor usually reflects laryngeal edema; cool humidified oxygen plus racemic epinephrine reduces mucosal swelling, and the provider should be notified so airway readiness for reintubation can be assessed.

  158. Question 158Initiation and Modification of Therapeutic Interventions

    A patient is receiving oxygen by nasal cannula at 4 L/min. Which fraction of inspired oxygen does this flow most closely provide?

    1. 44%
    2. 28%
    3. 36% Correct answer.
    4. 24%

    Explanation

    A rough clinical estimate is about 24% at 1 L/min with an increase of roughly 4% for each additional liter per minute, so 4 L/min corresponds to about 36% (a realistic range of 33% to 40%). The actual value varies with the patient's inspiratory flow and breathing pattern.

  159. Question 159Initiation and Modification of Therapeutic Interventions

    Which mass median aerodynamic diameter (MMAD) produces the greatest deposition in the lower respiratory tract?

    1. 12 micrometers
    2. 25 micrometers
    3. 0.2 micrometers
    4. 3 micrometers Correct answer.

    Explanation

    Particles in the 1 to 5 micrometer range are small enough to pass the upper airway but large enough to settle by sedimentation in the bronchi and alveoli. Particles below about 0.5 micrometer are largely exhaled again, and particles above 10 micrometers impact in the oropharynx and large airways.

  160. Question 160Initiation and Modification of Therapeutic Interventions

    What is the primary therapeutic goal of incentive spirometry?

    1. To mobilize secretions by generating high expiratory flows
    2. To strengthen the diaphragm against a resistive load
    3. To deliver bronchodilator medication to the lower airways
    4. To prevent or reverse atelectasis through sustained maximal inspiration Correct answer.

    Explanation

    Incentive spirometry encourages a slow, sustained maximal inspiration that re-expands collapsed alveoli and helps prevent postoperative atelectasis. It is not a drug delivery device, a muscle-strengthening device, or a secretion clearance technique.

  161. Question 161Initiation and Modification of Therapeutic Interventions

    During manual ventilation with a bag-valve-mask, which observation best indicates that an adequate tidal volume is being delivered?

    1. The patient's pupils remain equal and reactive
    2. Visible chest rise occurs with each squeeze Correct answer.
    3. The mask seals without an audible leak
    4. The bag refills rapidly between breaths

    Explanation

    Chest rise is the most reliable bedside indicator that gas is actually entering the lungs during bag-valve-mask ventilation. Bag refill and mask seal reflect the equipment, and pupillary findings reflect neurologic status rather than ventilation.

  162. Question 162Initiation and Modification of Therapeutic Interventions

    A patient receiving oxygen by nasal cannula at 6 L/min reports nasal dryness and has a small amount of epistaxis. Which action is most appropriate?

    1. Add a bubble humidifier to the oxygen system Correct answer.
    2. Switch the patient to a nonrebreather mask at 15 L/min
    3. Increase the flow to 8 L/min to overcome the resistance
    4. Discontinue the oxygen and reassess in 30 minutes

    Explanation

    Dryness and mucosal irritation are common when low-flow oxygen exceeds about 4 L/min, and adding a bubble humidifier moistens the gas and relieves the symptoms. Increasing the flow or escalating to a high-FiO2 device would worsen the drying, and stopping oxygen is unsafe.

  163. Question 163Initiation and Modification of Therapeutic Interventions

    Which condition can cause a pulse oximeter to display a falsely low saturation?

    1. Poor peripheral perfusion Correct answer.
    2. Elevated carboxyhemoglobin
    3. Bright ambient light
    4. Elevated fetal hemoglobin

    Explanation

    Poor perfusion, motion, and venous congestion reduce signal quality and commonly produce falsely low readings. Carboxyhemoglobin typically produces falsely high readings, and fetal hemoglobin shifts the curve without producing a clinically important false reading at usual saturations.

  164. Question 164Initiation and Modification of Therapeutic Interventions

    A patient with right-sided pneumonia and severe hypoxemia is being positioned to improve oxygenation. Which position is preferred?

    1. Left lateral decubitus, unaffected lung down Correct answer.
    2. Prone, head turned to the right
    3. Supine, head of bed flat
    4. Right lateral decubitus, affected lung down

    Explanation

    Positioning the healthy lung in the dependent position improves matching of perfusion to ventilation because the consolidated lung contributes little ventilation regardless of position. Placing the diseased lung down increases shunt through the nonventilated region and can worsen hypoxemia.

  165. Question 165Initiation and Modification of Therapeutic Interventions

    Which item should be kept at the bedside of a patient with a newly placed tracheostomy?

    1. A chest tube insertion tray
    2. A bottle of sterile saline for routine instillation
    3. A tracheostomy tube one size smaller with an obturator Correct answer.
    4. A spare cuffed endotracheal tube of the same size

    Explanation

    A replacement tube of the same or one smaller size plus an obturator allows rapid re-establishment of the airway if the tube is dislodged or obstructed. Routine saline instillation is no longer recommended, and an endotracheal tube is not the appropriate backup device for a stoma.

  166. Question 166Initiation and Modification of Therapeutic Interventions

    A patient on volume-control ventilation has a peak airway pressure of 48 cm H2O, up from a baseline of 28 cm H2O, with an unchanged plateau pressure of 20 cm H2O. Which action is most appropriate?

    1. Increase the set PEEP by 5 cm H2O
    2. Reduce the set tidal volume by 100 mL
    3. Suction the airway and assess for bronchospasm Correct answer.
    4. Obtain a chest radiograph to rule out pneumothorax

    Explanation

    A rising peak pressure with a normal plateau pressure indicates an increase in resistive load, such as secretions, bronchospasm, biting, or a kinked circuit. Suctioning and bronchodilator assessment address that resistive component. Processes that stiffen the lung or chest wall raise the plateau pressure as well.

  167. Question 167Initiation and Modification of Therapeutic Interventions

    A patient with an acute exacerbation of COPD has a pH of 7.26, a PaCO2 of 68 mm Hg, and is alert and cooperative. Which intervention is most appropriate?

    1. Intubate and begin volume-control ventilation
    2. Place the patient on a 40% air-entrainment mask
    3. Start noninvasive positive-pressure ventilation (BiPAP) Correct answer.
    4. Begin continuous nebulized albuterol at 10 mg/h

    Explanation

    Hypercapnic respiratory acidosis with an alert, cooperative patient is the classic indication for noninvasive positive-pressure ventilation, which reduces work of breathing and intubation rates in COPD exacerbation. Intubation is reserved for failure of noninvasive support or contraindications such as inability to protect the airway.

  168. Question 168Initiation and Modification of Therapeutic Interventions

    A patient using a metered-dose inhaler with a valved holding chamber should be instructed to:

    1. Actuate, then inhale slowly and deeply and hold up to 10 seconds Correct answer.
    2. Actuate two puffs at once to shorten the treatment time
    3. Actuate the canister, then exhale fully before inhaling
    4. Inhale rapidly and forcefully as soon as the canister is actuated

    Explanation

    A slow, deep inhalation followed by a breath hold allows the aerosol to travel past the upper airway and deposit in the lower respiratory tract. A holding chamber removes the need for precise coordination, but the inhalation maneuver still matters.

  169. Question 169Initiation and Modification of Therapeutic Interventions

    A mechanically ventilated patient using a heat-and-moisture exchanger has thick, tenacious secretions and a core temperature of 39.2 degrees C. Which change is most appropriate?

    1. Decrease the ventilator inspiratory flow rate
    2. Increase the heat-and-moisture exchanger temperature setting by 3 degrees
    3. Instill 5 mL of saline into the airway every 2 hours
    4. Swap the heat-and-moisture exchanger for a heated humidifier Correct answer.

    Explanation

    Passive heat-and-moisture exchangers provide limited humidification and are a poor choice with thick secretions, hypothermia, or high fever; an active heated humidifier delivers more water vapor. Routine saline instillation is not recommended, and an HME has no temperature control.

  170. Question 170Initiation and Modification of Therapeutic Interventions

    Continuous bubbling is noted in the water-seal chamber of a patient's chest drainage system. Which action is most appropriate?

    1. Clamp the chest tube immediately
    2. Check the tubing connections and insertion site for an air leak Correct answer.
    3. Milk the tubing toward the collection chamber
    4. Add sterile water until the bubbling stops

    Explanation

    Bubbling in the water-seal chamber that persists beyond the first minutes indicates air entering the system, most often from a loose connection, a leak at the insertion site, or a bronchopleural fistula. The therapist should locate and correct the source rather than clamp the tube, which risks a tension pneumothorax.

  171. Question 171Initiation and Modification of Therapeutic Interventions

    Which suction catheter size is appropriate for an 8.0-mm inner-diameter tracheostomy tube?

    1. 14 Fr Correct answer.
    2. 20 Fr
    3. 10 Fr
    4. 18 Fr

    Explanation

    A common rule is to use a French size no larger than about twice the tube's inner diameter in millimeters minus two, which gives 14 Fr for an 8.0-mm tube. The catheter should also occupy no more than about half of the tube's cross-sectional area to avoid excessive negative pressure and hypoxemia.

  172. Question 172Initiation and Modification of Therapeutic Interventions

    The capnogram of an intubated patient suddenly falls to zero. Which action should the therapist take first?

    1. Increase the set respiratory rate
    2. Assess the patient and check the tube for disconnection Correct answer.
    3. Obtain an arterial blood gas sample
    4. Increase the FiO2 to 1.00

    Explanation

    An abrupt loss of the capnogram most often means the endotracheal tube is dislodged or disconnected, or that pulmonary blood flow has ceased. The immediate priority is to look at the patient and the airway and restore the circuit, not to change ventilator settings or draw blood.

  173. Question 173Initiation and Modification of Therapeutic Interventions

    Which rapid shallow breathing index (RSBI) value is most predictive of weaning success?

    1. 60 breaths/min/L Correct answer.
    2. 160 breaths/min/L
    3. 130 breaths/min/L
    4. 105 breaths/min/L

    Explanation

    The RSBI is the spontaneous respiratory rate divided by the average spontaneous tidal volume in liters, and values below 105 predict a successful wean. Lower values, such as 60, reflect a slower, deeper breathing pattern and predict success even more strongly.

  174. Question 174Initiation and Modification of Therapeutic Interventions

    Which patient is the most appropriate candidate for intermittent positive-pressure breathing (IPPB) therapy?

    1. A patient with hemoptysis and a low platelet count
    2. A postoperative patient with atelectasis who cannot breathe deeply Correct answer.
    3. An alert patient with a normal chest radiograph
    4. A patient with a pneumothorax and a chest tube

    Explanation

    IPPB is indicated for patients who cannot achieve a deep breath on their own, such as a postoperative patient with atelectasis limited by incisional pain. Untreated pneumothorax and active hemoptysis are contraindications because positive pressure and airway irritation can worsen them.

  175. Question 175Initiation and Modification of Therapeutic Interventions

    At what gas flow should a small-volume nebulizer typically be driven to produce an optimal aerosol?

    1. 2 L/min
    2. 20 L/min
    3. 12 to 15 L/min
    4. 6 to 8 L/min Correct answer.

    Explanation

    Driving a small-volume nebulizer at 6 to 8 L/min produces an output near 0.3 mL/min with particles predominantly in the respirable range. Higher flows increase particle size and waste medication as well as gas, while very low flows deliver an inadequate dose.

  176. Question 176Initiation and Modification of Therapeutic Interventions

    A patient is being transported with an E cylinder that reads 1500 psi and is delivering oxygen at 10 L/min. Approximately how long will the cylinder last?

    1. About 120 minutes
    2. About 90 minutes
    3. About 42 minutes Correct answer.
    4. About 15 minutes

    Explanation

    Cylinder duration equals the gauge pressure multiplied by the cylinder factor, divided by the flow. For an E cylinder the factor is about 0.28, so (1500 x 0.28) / 10 is approximately 42 minutes.

  177. Question 177Initiation and Modification of Therapeutic Interventions

    What is the approximate arterial oxygen content for a patient with a hemoglobin of 10 g/dL, an SaO2 of 90%, and a PaO2 of 60 mm Hg?

    1. 15.5 mL/dL
    2. 11.0 mL/dL
    3. 9.8 mL/dL
    4. 12.2 mL/dL Correct answer.

    Explanation

    Arterial oxygen content is calculated as (1.34 x hemoglobin x SaO2) + (0.003 x PaO2). Here that is (1.34 x 10 x 0.90) + (0.003 x 60), or 12.06 + 0.18, which is approximately 12.2 mL/dL.

  178. Question 178Initiation and Modification of Therapeutic Interventions

    A patient with ARDS on volume-control ventilation has a plateau pressure of 30 cm H2O and a total PEEP of 12 cm H2O. Which change best reduces the risk of ventilator-induced lung injury?

    1. Switch to pressure support at 20 cm H2O
    2. Reduce the set tidal volume Correct answer.
    3. Increase the set PEEP to 18 cm H2O
    4. Increase the inspiratory flow rate

    Explanation

    Driving pressure is the plateau pressure minus total PEEP, which here is 18 cm H2O, above the commonly targeted 15 cm H2O. Lowering the tidal volume reduces the driving pressure and cyclic strain on the lung, whereas raising PEEP further would raise the plateau pressure.

  179. Question 179Initiation and Modification of Therapeutic Interventions

    A patient with a COPD exacerbation has been on BiPAP for 2 hours. The pH is now 7.22, the PaCO2 is 75 mm Hg, and the patient is increasingly drowsy. Which action is most appropriate?

    1. Give a sodium bicarbonate bolus and reassess in 1 hour
    2. Prepare for endotracheal intubation Correct answer.
    3. Switch to high-flow nasal cannula at 60 L/min
    4. Increase the inspiratory positive airway pressure and continue BiPAP

    Explanation

    Worsening acidosis with decreasing consciousness despite an adequate trial of noninvasive ventilation indicates failure of that therapy and the need for invasive ventilatory support. Delay increases the risk of aspiration and cardiopulmonary arrest during an emergency intubation.

  180. Question 180Initiation and Modification of Therapeutic Interventions

    A ventilated patient with a pulmonary embolism has a PaCO2 of 60 mm Hg and an end-tidal CO2 of 30 mm Hg. Which finding best explains this difference?

    1. Reduced functional residual capacity
    2. Increased pulmonary blood flow
    3. Hypermetabolism
    4. Increased physiologic dead space Correct answer.

    Explanation

    A widened PaCO2 to end-tidal CO2 gradient reflects ventilation of lung units that are not perfused, so CO2 is not excreted and the exhaled concentration falls. Pulmonary embolism creates exactly this kind of dead space by obstructing pulmonary blood flow.

  181. Question 181Initiation and Modification of Therapeutic Interventions

    Heliox is administered to a patient with severe upper airway obstruction. Which property primarily accounts for the improvement in gas flow?

    1. Low gas density reduces turbulent flow and resistive work Correct answer.
    2. Higher gas viscosity reduces airway resistance
    3. High oxygen concentration improves alveolar oxygenation
    4. Cooling of the airway reduces mucosal edema

    Explanation

    Helium is much less dense than nitrogen, which lowers the Reynolds number and converts turbulent flow in narrowed airways to more efficient laminar flow. The result is reduced resistive work of breathing. Heliox blends usually contain less oxygen than the patient was previously receiving.

  182. Question 182Initiation and Modification of Therapeutic Interventions

    What is the minimum oxygen flow rate at which a simple face mask should be operated?

    1. 5 L/min Correct answer.
    2. 15 L/min
    3. 10 L/min
    4. 2 L/min

    Explanation

    A simple face mask must be driven at a minimum of about 5 L/min so that exhaled carbon dioxide is flushed out of the mask between breaths. At lower flows the patient rebreathes CO2, and the delivered oxygen concentration also becomes unreliable.

  183. Question 183Initiation and Modification of Therapeutic Interventions

    A patient with a severe asthma exacerbation cannot coordinate inhaler actuation with inhalation and has a weak inspiratory effort. Which delivery method is most appropriate for a bronchodilator?

    1. Small-volume nebulizer with a mouthpiece Correct answer.
    2. Dry-powder inhaler
    3. Metered-dose inhaler with a valved holding chamber
    4. Metered-dose inhaler used without a holding chamber

    Explanation

    A small-volume nebulizer generates the aerosol independently of the patient's inspiratory effort, so it does not require coordination or a strong breath. Devices that depend on the patient's inspiratory flow or on timed actuation are unreliable in this setting.

  184. Question 184Initiation and Modification of Therapeutic Interventions

    Which complication is most closely associated with inadequate humidification of inspired gas during mechanical ventilation?

    1. Retained secretions and endotracheal tube occlusion Correct answer.
    2. Air trapping from incomplete exhalation
    3. Intrapulmonary shunting from alveolar collapse
    4. Hypercapnia from increased dead space

    Explanation

    When inspired gas is under-humidified, the airway mucosa loses heat and water, mucus becomes thick and viscous, and mucociliary clearance fails. The result is secretion retention, mucus plugging, and potential obstruction of the artificial airway.

  185. Question 185Initiation and Modification of Therapeutic Interventions

    How should a patient be instructed to use an incentive spirometer?

    1. Inhale slowly to maximal capacity and hold for 3 to 5 seconds Correct answer.
    2. Breathe rapidly in and out through the mouthpiece for one full minute
    3. Inhale in short puffs, then cough forcefully at the end of the maneuver
    4. Exhale forcefully into the mouthpiece, then inhale as quickly as possible

    Explanation

    Incentive spirometry is a sustained maximal inspiration maneuver: a slow, deep breath to total lung capacity followed by a 3- to 5-second breath hold. The hold sustains alveolar recruitment, and the maneuver is repeated about 10 times per hour while awake.

  186. Question 186Initiation and Modification of Therapeutic Interventions

    Which finding is a contraindication to placing a patient in the Trendelenburg position for postural drainage?

    1. Chronic bronchitis with copious secretions
    2. Cystic fibrosis with bilateral lower lobe disease
    3. Recent head injury with elevated intracranial pressure Correct answer.
    4. Neuromuscular weakness with an ineffective cough

    Explanation

    Head-down positioning raises intracranial pressure by increasing cerebral venous and arterial pressure, so elevated ICP makes Trendelenburg positioning unsafe. Copious secretions and weak cough are indications for clearance therapy, not contraindications to positioning alone.

  187. Question 187Initiation and Modification of Therapeutic Interventions

    Which initial tidal volume is recommended when volume-control ventilation is begun for a patient with no known lung disease?

    1. 4 to 5 mL/kg of actual body weight
    2. 10 to 12 mL/kg of actual body weight
    3. 6 to 8 mL/kg of predicted body weight Correct answer.
    4. 12 to 15 mL/kg of predicted body weight

    Explanation

    Initial tidal volume is set at 6 to 8 mL/kg of predicted body weight in patients with healthy lungs, and lower (about 6 mL/kg) when lung injury is present. Predicted body weight based on height is used because actual weight overestimates the aerated lung and can lead to injurious volumes.

  188. Question 188Initiation and Modification of Therapeutic Interventions

    A patient with severe asthma on volume-control ventilation has a set PEEP of 5 cm H2O, a measured total PEEP of 10 cm H2O, and a flow-time curve in which expiratory flow does not return to zero before the next breath. Which change is most appropriate?

    1. Increase the tidal volume
    2. Increase the set respiratory rate
    3. Decrease the set respiratory rate Correct answer.
    4. Increase the applied PEEP to 10 cm H2O

    Explanation

    Expiratory flow that fails to reach zero, together with a total PEEP higher than the set PEEP, indicates dynamic hyperinflation and auto-PEEP. Lowering the respiratory rate lengthens expiratory time so that the next breath begins after exhalation is complete.

  189. Question 189Initiation and Modification of Therapeutic Interventions

    Which finding is a contraindication to initiating noninvasive positive-pressure ventilation?

    1. Respiratory rate of 30 breaths/min
    2. PaCO2 of 65 mm Hg
    3. Arterial pH of 7.28
    4. Copious secretions with an absent gag reflex Correct answer.

    Explanation

    Noninvasive ventilation depends on the patient's ability to protect the airway and clear secretions; absent airway reflexes with copious secretions risk aspiration and delay needed intubation. Hypercapnia, tachypnea, and mild acidosis are typical indications rather than contraindications.

  190. Question 190Initiation and Modification of Therapeutic Interventions

    Which finding during a spontaneous breathing trial indicates that the trial should be stopped?

    1. Spontaneous tidal volume of 450 mL
    2. Respiratory rate of 22 breaths/min
    3. SpO2 falls to 86% with accessory muscle use Correct answer.
    4. Heart rate of 100 beats/min

    Explanation

    Desaturation below 90% accompanied by increased work of breathing signals failure of the trial and the need to return the patient to full ventilatory support. Stable rates, heart rates near baseline, and adequate tidal volumes are signs of tolerance.

  191. Question 191Initiation and Modification of Therapeutic Interventions

    Which cuff pressure range should be maintained for a tracheostomy tube?

    1. 20 to 30 cm H2O Correct answer.
    2. 50 to 60 cm H2O
    3. 5 to 10 cm H2O
    4. 35 to 45 cm H2O

    Explanation

    Cuff pressure is kept between about 20 and 30 cm H2O, which seals the airway against aspiration while remaining below tracheal capillary perfusion pressure. Higher pressures risk mucosal ischemia, and lower pressures permit leak and aspiration.

  192. Question 192Initiation and Modification of Therapeutic Interventions

    Suction applied through an artificial airway should be limited to no more than how long per pass?

    1. 10 to 15 seconds Correct answer.
    2. 5 seconds
    3. 2 to 3 seconds
    4. 30 seconds

    Explanation

    Each suction pass is limited to about 10 to 15 seconds to reduce hypoxemia, vagal stimulation, and mucosal trauma. The patient should be hyperoxygenated before and after suctioning, with the catheter advanced only as far as needed.

  193. Question 193Initiation and Modification of Therapeutic Interventions

    A patient is receiving oxygen by nasal cannula at 4 L/min. Approximately what oxygen concentration is being delivered?

    1. 28%
    2. 36% Correct answer.
    3. 24%
    4. 32%

    Explanation

    With a nasal cannula, the first liter per minute provides roughly 24% and each additional liter adds about 4%. Four liters per minute therefore delivers approximately 36%, although the actual value varies with the patient's minute ventilation and breathing pattern.

  194. Question 194Initiation and Modification of Therapeutic Interventions

    Thirty minutes after a nebulized albuterol treatment, a patient's heart rate has risen from 84 to 132 beats/min and the patient reports palpitations. Which action is most appropriate?

    1. Withhold further bronchodilator doses and notify the provider Correct answer.
    2. Increase the albuterol dose for the next treatment
    3. Repeat the treatment with the same dose
    4. Document the findings and continue the ordered schedule unchanged

    Explanation

    A heart rate increase of more than about 20 beats/min with palpitations is a significant beta-agonist adverse effect, so further doses should be held and the provider notified. The order may be revised, for example to a lower dose or a more beta-2-selective agent.

  195. Question 195Initiation and Modification of Therapeutic Interventions

    Which device is designed to apply positive expiratory pressure to help mobilize secretions?

    1. Simple oxygen mask
    2. Flutter or PEP valve Correct answer.
    3. Intermittent positive-pressure breathing device
    4. Incentive spirometer

    Explanation

    Flutter and PEP valves create positive pressure during exhalation, which splints airways open and moves secretions proximally toward the large airways. They are used as part of an airway clearance regimen, often with huff coughing.

  196. Question 196Initiation and Modification of Therapeutic Interventions

    Which oxygen saturation target is recommended for a patient with ARDS receiving mechanical ventilation?

    1. 96% to 100%
    2. 88% to 95% Correct answer.
    3. 100% at all times
    4. 80% to 85%

    Explanation

    Lung-protective ventilation in ARDS targets an SpO2 of about 88% to 95%, accepting some hypoxemia in exchange for lower FiO2 and PEEP exposure. This reduces the risk of oxygen toxicity and ventilator-induced lung injury while maintaining adequate oxygen delivery.

  197. Question 197Initiation and Modification of Therapeutic Interventions

    A ventilated patient has a PaCO2 of 30 mm Hg and a pH of 7.52 with a set respiratory rate of 18 breaths/min and a tidal volume of 500 mL. Which change is most appropriate?

    1. Decrease the set respiratory rate Correct answer.
    2. Add 5 cm H2O of PEEP
    3. Increase the tidal volume to 600 mL
    4. Increase the respiratory rate to 22 breaths/min

    Explanation

    The high pH with a low PaCO2 indicates respiratory alkalosis caused by excessive alveolar ventilation. Reducing the respiratory rate lowers minute ventilation and allows the PaCO2 to rise back toward the target range.

  198. Question 198Initiation and Modification of Therapeutic Interventions

    A patient requires a precise inspired oxygen fraction of 0.40 but has an irregular respiratory pattern and variable minute ventilation. Which device is most appropriate?

    1. Air-entrainment (Venturi) mask set at 40% Correct answer.
    2. Nasal cannula at 4 L/min
    3. Partial nonrebreather mask at 10 L/min
    4. Simple face mask at 8 L/min

    Explanation

    An air-entrainment mask uses a fixed orifice to blend oxygen with room air and delivers a constant FiO2 regardless of the patient's breathing pattern. Low-flow devices vary in the oxygen concentration they produce as minute ventilation changes.

  199. Question 199Initiation and Modification of Therapeutic Interventions

    A low-pressure alarm sounds on a patient receiving volume-control ventilation. Which cause is most likely?

    1. Circuit disconnection Correct answer.
    2. Bronchospasm
    3. Retained airway secretions
    4. The patient biting on the endotracheal tube

    Explanation

    A low-pressure alarm indicates that the ventilator cannot generate the expected pressure, which typically means a leak somewhere in the patient-ventilator system. Disconnection, a deflated cuff, or a loose humidifier connection are common causes.

  200. Question 200Initiation and Modification of Therapeutic Interventions

    A patient receiving pressure-control ventilation has a delivered tidal volume that falls from 500 mL to 350 mL while the set inspiratory pressure remains at 25 cm H2O. Which explanation is most likely?

    1. Improved lung compliance
    2. Increased airway resistance
    3. Decreased lung compliance Correct answer.
    4. Reduced circuit compliance

    Explanation

    In pressure-control ventilation the delivered volume is determined by the set pressure and the compliance of the lung and chest wall. If compliance falls, the same driving pressure inflates the lungs less and the exhaled tidal volume decreases.

NBRC CRT flashcards

32 cards. Read the term and the definition here. The deck at the top of this page is optional.

Minute ventilation formula
Minute ventilation equals respiratory rate multiplied by tidal volume; normal adult values are roughly 5–8 L/min, and it reflects total gas moved per minute.
Predicted body weight formula
For males, 50 kg plus 2.3 kg for each inch over 60; for females, 45.5 kg plus 2.3 kg per inch over 60.
Normal arterial blood gas
pH 7.35–7.45, PaCO2 35–45 mm Hg, HCO3− 22–26 mEq/L, and PaO2 80–100 mm Hg while breathing room air at sea level.
Respiratory acidosis
A primary disorder with pH below 7.35 and PaCO2 above 45 mm Hg; causes include hypoventilation, airway obstruction, and neuromuscular weakness.
Respiratory alkalosis
A primary disorder with pH above 7.45 and PaCO2 below 35 mm Hg; causes include hyperventilation from pain, anxiety, hypoxia, or overventilation.
Metabolic acidosis
A primary disorder with pH below 7.35 and HCO3− below 22 mEq/L; compensation increases ventilation to lower PaCO2.
Winter's formula
Expected PaCO2 in metabolic acidosis equals 1.5 times serum HCO3− plus 8, with a margin of plus or minus 2 mm Hg.
P/F ratio
PaO2 divided by FiO2; a normal value exceeds 400, while values below 300 suggest impaired oxygenation and below 200 suggest severe impairment.
A-a gradient
Alveolar oxygen minus arterial oxygen; alveolar oxygen equals FiO2 times barometric pressure minus 47, minus PaCO2 divided by 0.8.
End-tidal CO2 normal
Normal end-tidal carbon dioxide is 35–45 mm Hg and approximates PaCO2 in healthy patients; a sudden decrease may indicate disconnection or low perfusion.
COPD oxygen target
For a COPD patient with chronic hypercapnia, titrate oxygen to SpO2 88–92% to reduce the risk of oxygen-induced hypercapnia.
Thorpe tube reading
Read the center of the float on an upright Thorpe-tube flowmeter; the tube must be calibrated for the gas and not obstructed downstream.
Oxygen cylinder duration
Duration in minutes equals gauge pressure in psi times cylinder factor, divided by flow in L/min; an E cylinder factor is 0.28.
Ventilator leak test
Occlude the patient Y-piece and observe the pressure; a sustained set pressure without decay indicates an intact circuit.
High-pressure alarm cause
Secretions, biting, kinked tubing, bronchospasm, or a water-filled circuit can raise airway pressure and trigger a high-pressure ventilator alarm.
Low-pressure alarm cause
Circuit disconnection, a leak, a loose humidifier, or inadequate gas supply can lower airway pressure and trigger a low-pressure ventilator alarm.
Airborne precautions
Use an N95 respirator and a negative-pressure room for tuberculosis, measles, and varicella; these pathogens remain suspended in air over long distances.
Droplet precautions
Use a surgical mask and eye protection for influenza, pertussis, and meningococcal disease; droplets travel short distances and settle quickly.
Contact precautions
Use gown and gloves and dedicate equipment for C. difficile, MRSA, and other contact-spread organisms; hand hygiene with soap and water is preferred for C. difficile.
High-level disinfection
Semicritical devices such as bronchoscopes require high-level disinfection to destroy all microorganisms except high numbers of bacterial spores.
Ethylene oxide use
Ethylene oxide sterilizes heat-sensitive equipment, but items must be aerated because residual gas is toxic and irritating.
Suction pressure adult
Typical adult suction negative pressure is −80 to −120 mm Hg; excessive pressure can damage mucosa and promote atelectasis.
Nasal cannula FiO2
At 1–6 L/min, a nasal cannula delivers approximately 24–44% oxygen; flow above 6 L/min often requires humidification.
Simple mask FiO2
A simple mask at 5–10 L/min delivers approximately 35–50% oxygen; minimum flow should be 5 L/min to clear exhaled CO2.
Venturi mask purpose
A Venturi mask uses an air-entrainment jet to deliver precise low FiO2 values, usually 24–50%, making it useful for controlled oxygen therapy.
Nonrebreather mask
At 10–15 L/min, a nonrebreather mask with a reservoir delivers approximately 80–95% oxygen; the bag must be inflated before use.
Initial ventilator settings
For most adults, start with tidal volume 6–8 mL/kg predicted body weight, rate 12–20/min, PEEP 5 cm H2O, and FiO2 to target saturation.
ARDS lung protection
Use tidal volume 4–6 mL/kg predicted body weight and keep plateau pressure at or below 30 cm H2O to reduce ventilator-induced lung injury.
RSBI
Rapid shallow breathing index equals respiratory rate divided by tidal volume in liters; a value below 105 suggests readiness for weaning.
MIP weaning threshold
A maximal inspiratory pressure more negative than −20 to −30 cm H2O suggests adequate respiratory muscle strength for weaning.
COPD oxygen titration
In COPD with chronic hypercapnia, titrate oxygen to SpO2 88–92%; avoid high-flow oxygen that may worsen CO2 retention.
HME contraindications
Avoid heat-and-moisture exchangers with thick secretions, hemoptysis, or very low tidal volumes because they can obstruct or add dead space.

NBRC CRT study guide

Patient Data: Gathering, Validating, and Interpreting Clinical Information

Collect before you interpret

Every data question starts with the same discipline: confirm the source and quality of the value before reasoning from it. Verify that a blood gas is arterial (PaO2 and PaCO2 relationship is plausible), that a pulse oximeter is tracing a believable plethysmograph, and that a spirometry effort meets acceptability and repeatability criteria before you act on the number.

Core concepts you must own

  • Vital signs and expected ranges, including how fever, pain, and anxiety shift heart rate and respiratory rate.
  • ABG interpretation in three steps: pH status, primary disorder from PaCO2/HCO3, then compensation. Memorize the quick rules: a 10 mm Hg rise in PaCO2 lowers pH about 0.08 and raises HCO3 about 1 mEq/L acutely.
  • Oxygenation versus ventilation: PaO2, SaO2, and SpO2 measure different things, and oxygen content also depends on hemoglobin.
  • Capnography: the EtCO2 value is read at the end of phase III, not the peak of the upstroke; a sloping upstroke suggests obstruction.
  • Hemodynamics: cardiac output, cardiac index, and SVR, and how they pair with the physical exam.
  • Radiographic and laboratory findings you must be able to describe and report, not diagnose.
  • Documentation: what you measured, when, with what device, and what you did about it.

Traps

Expect items where the SpO2 looks reassuring but oxygenation is not (carbon monoxide, anemia, poor perfusion, motion artifact, dark nail polish) and items where a "normal" PaCO2 masks chronic compensation. Also expect questions on whose job it is to report abnormal data - almost always yours, promptly.

Worked rule

pH 7.28, PaCO2 60 mm Hg, HCO3 26 mEq/L. The pH is acidemic and the PaCO2 is elevated, so the primary problem is respiratory acidosis. Expected acute HCO3 at that PaCO2 is about 25 mEq/L; 26 is within 1, so this is acute with essentially no compensation. Report it and escalate rather than waiting for the next gas.

Troubleshooting and Quality Control of Equipment and Infection Control

Two jobs in one domain

This domain tests two reflexes: find the cause of an equipment problem fast, and never contaminate a patient or yourself while doing it.

Equipment troubleshooting

Work in order: patient, circuit, machine. Know the alarm logic. High peak pressure with a normal plateau points to increased airway resistance (secretions, bronchospasm, kinked or bitten tube); high plateau pressure points to decreased compliance (pneumothorax, atelectasis, ARDS, abdominal distention, mainstem intubation). Low-pressure or low-volume alarms mean a leak: disconnection, deflated cuff, cracked circuit, or chest tube leak. For oxygen delivery, check analyzer calibration (about 21% in room air, 100% on high FiO2), source pressure, and air-entrainment ports. Measure cuff pressure with a calibrated gauge, targeting roughly 20–30 cm H2O.

Quality control means scheduled verification against a known standard, documented: oxygen analyzers calibrated before use, spirometers checked with a 3-L syringe, blood gas analyzers run with control materials, and preventive maintenance logs kept current.

Infection control

Hand hygiene is the highest-yield answer on any item. Know standard precautions for every patient and transmission-based precautions by route: contact (C. difficile, MRSA), droplet (influenza, pertussis), airborne (tuberculosis, measles, varicella). Don and doff PPE in sequence - gown, mask, eye protection, gloves on; gloves and gown removed first. Distinguish cleaning, disinfection, and sterilization: semicritical items such as bronchoscopes need high-level disinfection, while critical items need sterilization. Drain circuit condensate away from the patient, keep the circuit closed, and change circuits when visibly soiled or malfunctioning rather than on a fixed calendar.

Worked rule

Peak pressure 45 cm H2O with a plateau of 30: the 15 cm H2O difference is resistive. Suction and assess for bronchospasm before you touch ventilator settings.

Initiation and Modification of Therapeutic Interventions

From order to titration

Every intervention item yields to the same sequence: confirm the indication, select the device, set the parameter, set alarm limits that bracket the goal, reassess, then document. Know your targets: SpO2 94–98% for most adults and 88–92% for patients at risk of hypercapnic respiratory failure.

Devices and settings

Low-flow oxygen (nasal cannula, simple mask) delivers a variable, estimated FiO2; air-entrainment and high-flow devices (Venturi mask, high-flow nasal cannula) deliver a set FiO2 and, with HFNC, flow-dependent dead-space washout plus low-level positive pressure. For lung expansion, understand incentive spirometry targets, IPPB indications, and CPAP/PEP pressures. For bronchial hygiene, match the technique to the problem: secretion mobilization (modified postural drainage, oscillating PEP, high-frequency chest wall oscillation) versus secretion clearance (cough augmentation, suctioning, mechanical insufflation-exsufflation).

Mechanical ventilation

Initial settings should be reasoned, not memorized: mode, tidal volume 6–8 mL/kg predicted body weight (6 mL/kg in ARDS), rate to match needed minute ventilation, PEEP, and FiO2 titrated down as tolerated. Set alarms within about 10–20% of delivered values. Weaning combines daily spontaneous breathing trials with readiness measures: RSBI below about 105, NIF more negative than –20 to –25 cm H2O, and vital capacity above 10–15 mL/kg.

Traps

Do not chase saturation with FiO2 alone once it is already high - look for the cause and consider PEEP. Do not read a rising EtCO2 as improvement when it reflects hypoventilation. Beware "increase FiO2" as the answer when the real problem is a mucus plug or a worsening shunt.

Worked rule

RSBI = respiratory rate divided by tidal volume in liters. Rate 30 with VT 300 mL (0.3 L) gives 100, below 105: a favorable weaning sign, but only if the rest of the readiness picture fits.

NBRC CRT cheat sheet

Quick reference

Patient Data

  • Minute ventilation = respiratory rate × tidal volume; normal adult tidal volume is 6–8 mL/kg predicted body weight.

  • IBW (kg): male = 50 + 2.3 × (height in inches − 60); female = 45.5 + 2.3 × (height in inches − 60).

  • Normal ABG: pH 7.35–7.45, PaCO2 35–45 mm Hg, HCO3− 22–26 mEq/L, PaO2 80–100 mm Hg on room air.

  • Acid-base rule: pH and PaCO2 move opposite in respiratory disorders; pH and HCO3− move same in metabolic disorders.

  • Winter's formula for metabolic acidosis: expected PaCO2 = (1.5 × HCO3−) + 8 ± 2.

  • P/F ratio = PaO2 ÷ FiO2; values <300 indicate impaired oxygenation and <200 indicate severe impairment.

  • A-a gradient = PAO2 − PaO2; PAO2 = FiO2 × (Patm − 47) − (PaCO2 ÷ 0.8).

  • SpO2 88–92% is the typical target for a patient with COPD and chronic hypercapnia to avoid oxygen-induced hypercapnia.

  • Capnography: normal end-tidal CO2 is 35–45 mm Hg; a sudden drop suggests disconnection, leak, or cardiac arrest.

Quick reference

Troubleshooting and Quality Control of Equipment and Infection Control

  • Thorpe-tube flowmeter: read the center of the ball; it must be upright and not used with a restrictor that exceeds its calibrated flow.

  • Oxygen cylinder duration (min) = (gauge pressure in psi × cylinder factor) ÷ oxygen flow in L/min; E cylinder factor is 0.28, H cylinder 3.14.

  • Low-pressure ventilator alarm: suspect disconnection, circuit leak, or inadequate gas source; high-pressure alarm: suspect secretions, kinking, biting, or bronchospasm.

  • Before use, perform a ventilator leak test by occluding the patient Y-piece; a sustained set pressure indicates an intact circuit.

  • Adult suction pressure is generally −80 to −120 mm Hg; higher negative pressure increases mucosal trauma and atelectasis risk.

  • Airborne precautions: N95 or higher respirator and negative-pressure room for tuberculosis, measles, and varicella.

  • Droplet precautions: surgical mask and eye protection for influenza, pertussis, and meningococcal disease; contact precautions for C. difficile and MRSA.

  • High-level disinfection is required for bronchoscopes and other semicritical devices; ethylene oxide is used for heat-sensitive equipment.

  • Change ventilator circuits only when visibly soiled or malfunctioning; drain condensate away from the patient to prevent contamination.

Quick reference

Initiation and Modification of Therapeutic Interventions

  • Nasal cannula at 1–6 L/min delivers approximately 24–44% FiO2; a simple mask at 5–10 L/min delivers approximately 35–50%.

  • Venturi mask provides precise low FiO2 (24–50%) and is preferred when controlled oxygen is needed.

  • Nonrebreather mask at 10–15 L/min delivers approximately 80–95% FiO2; ensure reservoir bag is inflated before placement.

  • Initial invasive ventilation for adults: tidal volume 6–8 mL/kg IBW, respiratory rate 12–20/min, PEEP 5 cm H2O, and FiO2 to target SpO2.

  • ARDS lung-protective ventilation: tidal volume 4–6 mL/kg IBW and plateau pressure ≤30 cm H2O.

  • Weaning readiness: RSBI = respiratory rate ÷ tidal volume in liters <105; vital capacity >10–15 mL/kg; MIP more negative than −20 to −30 cm H2O.

  • For COPD, titrate oxygen to SpO2 88–92%; for most other adults, target SpO2 92–96%.

  • Aerosolized bronchodilator: administer beta-2 agonist before anticholinergic if both ordered; monitor heart rate, tremor, and paradoxical bronchospasm.

  • Humidification: heated humidifier or HME for ventilator circuits; avoid HME in patients with thick secretions, hemoptysis, or low tidal volumes.

NBRC CRT key terms

Tidal volume

Volume of gas moved into or out of the lungs during one breath, usually set at 6 to 8 mL/kg of predicted body weight in adults. It is used to calculate minute ventilation and static compliance.

Related: Minute ventilation, Static compliance
Minute ventilation

Total volume of gas entering and leaving the lungs each minute, equal to tidal volume multiplied by respiratory rate. Resting adult values are roughly 5 to 8 L/min and rise with fever, pain, and metabolic acidosis.

Related: Tidal volume, Auto-PEEP
Functional residual capacity

Volume of gas left in the lungs at the end of a quiet expiration. It reflects the balance between lung elastic recoil and outward chest wall pull and keeps alveoli open between breaths.

Related: PEEP, Auto-PEEP
FEV1/FVC ratio

Ratio of the forced expiratory volume in one second to the forced vital capacity. A value below about 70% suggests airflow obstruction, making it a core spirometry measurement.

Related: Airway resistance
Static compliance

Change in lung volume per unit change in distending pressure, measured during an inspiratory hold when flow has stopped. It is calculated as tidal volume divided by plateau pressure minus total PEEP.

Related: Plateau pressure, Tidal volume
Airway resistance

Pressure difference between the airway opening and the alveoli divided by gas flow. It rises with bronchospasm, retained secretions, and small endotracheal tubes, and shows up as a climbing peak inspiratory pressure.

Related: High-pressure alarm, Plateau pressure
Plateau pressure

Airway pressure measured during an end-inspiratory hold with no gas flow. It reflects alveolar distending pressure and lung compliance, and values above 30 cm H2O are linked to lung injury.

Related: Static compliance, Auto-PEEP
Auto-PEEP

Positive alveolar pressure remaining at end-expiration when the next breath begins before exhalation is complete. It is detected with an expiratory hold in a passive patient and is caused by high rates or short expiratory times.

Related: PEEP, Minute ventilation
Arterial blood gas

Laboratory analysis of an arterial sample reporting pH, PaCO2, PaO2, and calculated bicarbonate. It is the standard method for judging ventilation, oxygenation, and acid-base status.

Related: P/F ratio, Capnography
P/F ratio

PaO2 from an arterial blood gas divided by the fraction of inspired oxygen. It grades the severity of hypoxemia, and a very low value suggests shunt that supplemental oxygen cannot correct.

Related: Arterial blood gas, FiO2
Capnography

Continuous graphic display of carbon dioxide in exhaled gas. The end-tidal value approximates alveolar PCO2, confirms endotracheal tube placement, and reveals disconnection or cardiac arrest.

Related: Arterial blood gas
Shunt fraction

Percentage of cardiac output that passes through the lungs without contacting ventilated alveoli. Hypoxemia caused by shunt responds poorly to higher inspired oxygen and is estimated from the P/F ratio.

Related: P/F ratio, FiO2
Ventilator circuit leak test

Procedure in which the circuit is pressurized with the patient connection occluded to confirm that set volume or pressure is not lost through loose connections, cracked tubing, or a faulty valve.

Related: Low-pressure alarm, Calibration
Calibration

Adjusting a measuring device against a known reference standard so its readings are accurate. It is done at manufacturer-specified intervals and after sensor replacement, repair, or erratic readings.

Related: Oxygen analyzer
High-pressure alarm

Ventilator alarm that sounds when airway pressure exceeds a set limit. Common causes are secretions, bronchospasm, biting, kinked tubing, water in the circuit, and pneumothorax.

Related: Low-pressure alarm, Airway resistance
Low-pressure alarm

Alarm that activates when airway pressure falls below a set threshold, signaling a leak or disconnection. Causes include a disconnected circuit, a deflated cuff, or a chest tube air leak.

Related: High-pressure alarm, Ventilator circuit leak test
Air-oxygen blender

Device that mixes compressed air and oxygen in adjustable proportions to deliver a precise oxygen concentration. It needs both gas sources at adequate and roughly equal pressure to hold the set value.

Related: Oxygen analyzer, FiO2
Oxygen analyzer

Instrument that measures the oxygen concentration of gas being delivered. It is calibrated to room air and to 100% oxygen and is checked before use with a blender or ventilator.

Related: Air-oxygen blender, Calibration
Heated humidifier

Device that warms and adds water vapor to inspired gas so it reaches near body temperature and full saturation. It prevents heat loss and thick, dry secretions during invasive ventilation.

Related: Heat and moisture exchanger
Heat and moisture exchanger

Passive device placed in the breathing circuit that traps heat and water from exhaled gas and returns them on the next inspiration. It is avoided with thick secretions, very low tidal volumes, or hypothermia.

Related: Heated humidifier
Standard precautions

Infection control practices used for every patient regardless of diagnosis: hand hygiene plus gloves, gown, and eye or face protection based on the expected contact with blood and body fluids.

Related: Hand hygiene, Airborne precautions
Airborne precautions

Precautions for organisms spread by tiny droplet nuclei that stay suspended in air, such as tuberculosis. They require a negative-pressure room, a fit-tested N95 respirator or better, and a closed door.

Related: Standard precautions
High-level disinfection

Process that destroys all microorganisms except large numbers of bacterial spores. It is used for semi-critical items such as flexible bronchoscopes and reusable airway devices that contact mucous membranes.

Related: Standard precautions
Hand hygiene

Cleaning the hands with soap and water or an alcohol-based rub. It is the single most effective measure for preventing healthcare-associated infection and is done before and after patient contact and after glove removal.

Related: Standard precautions
FiO2

Fraction or percent of oxygen in the gas a patient inspires, ranging from 0.21 in room air to 1.0. It is adjusted to reach a target saturation or PaO2 while staying as low as is effective.

Related: P/F ratio, Oxygen analyzer
PEEP

Positive pressure maintained in the airway at the end of expiration. It keeps alveoli open, improves oxygenation, and reduces atelectasis, and it serves as the reference pressure when calculating static compliance.

Related: Auto-PEEP, Recruitment maneuver
Assist-control ventilation

Ventilator mode in which every breath, machine or patient initiated, receives the set tidal volume or pressure at a set backup rate. The patient can raise the rate but not the depth of each breath.

Related: SIMV, Pressure support ventilation
Pressure support ventilation

Spontaneous mode in which each patient-triggered breath is boosted by a set inspiratory pressure. The patient sets rate and inspiratory time, and the mode is often used while weaning.

Related: Spontaneous breathing trial, Assist-control ventilation
SIMV

Mode that delivers a set number of mandatory breaths each minute and allows spontaneous breaths between them, which may be pressure supported. It gradually returns work of breathing to the patient.

Related: Assist-control ventilation, Pressure support ventilation
Noninvasive ventilation

Positive pressure delivered through a nasal or full-face mask instead of an artificial airway. It is used for hypercapnic respiratory failure, COPD exacerbation, and some cases of pulmonary edema.

Related: High-flow nasal cannula, Pressure support ventilation
High-flow nasal cannula

Device that delivers heated, humidified gas at flows of about 30 to 60 L/min through nasal prongs. The high flow meets inspiratory demand, flushes dead space, and provides a small amount of positive pressure.

Related: Noninvasive ventilation, FiO2
Lung-protective ventilation

Strategy using tidal volumes near 6 mL/kg of predicted body weight with plateau pressure kept at or below 30 cm H2O. It reduces ventilator-induced lung injury and is standard care in acute respiratory distress syndrome.

Related: Tidal volume, Plateau pressure
Recruitment maneuver

Brief application of higher airway pressure to reopen collapsed alveoli, followed by enough PEEP to keep them open. It is used in hypoxemic respiratory failure and requires watching for hypotension.

Related: PEEP, Plateau pressure
Spontaneous breathing trial

Period of minimal ventilator support, such as a T-piece or low level of pressure support, used to judge whether a patient can breathe without the machine before extubation.

Related: Pressure support ventilation, SIMV
Small-volume nebulizer

Device that uses gas flow to turn a liquid drug into an aerosol inhaled through a mouthpiece or mask. It delivers bronchodilators and other agents, typically with flow set at 6 to 8 L/min.

Related: Metered-dose inhaler with valved holding chamber, FiO2
Metered-dose inhaler with valved holding chamber

Pressurized canister that releases a fixed dose of drug, used with a chamber that reduces drug impact in the mouth and throat and improves lung deposition, especially when the patient has poor coordination.

Related: Small-volume nebulizer
Incentive spirometer

Handheld device that gives visual feedback while the patient takes slow, deep breaths, encouraging lung expansion and helping prevent atelectasis after surgery or during prolonged bed rest.

Related: PEEP, Recruitment maneuver

NBRC CRT study plan

8 weeks · About 7 hours per week

Week 1

Initiation and Modification of Therapeutic Interventions

  • Select the initial oxygen or aerosol device and its FiO2/flow for a given scenario, and justify the choice against indication, contraindication, and hazard.

  • Calculate predicted body weight and a lung-protective tidal volume (4-8 mL/kg PBW), then set initial mode, rate, PEEP, and FiO2 for restrictive and obstructive presentations.

  • Distinguish the indications for noninvasive ventilation, invasive ventilation, and hyperinflation therapy, and state the failure criteria for each.

Your checkpoint

50-question Domain 3 practice block (oxygen, aerosol, and noninvasive ventilation) scored at or above 80%, with a one-line written correction for every missed item.

Week 2

Initiation and Modification of Therapeutic Interventions & Troubleshooting and Quality Control of Equipment and Infection Control

  • Modify ventilator settings in response to changes in compliance, airway resistance, auto-PEEP, and oxygenation or ventilation targets.

  • Interpret pressure-time, flow-time, and volume-time waveforms and name the correction for each common asynchrony pattern.

  • Map each high-priority ventilator alarm to an ordered assessment sequence and a first corrective action.

Your checkpoint

One-page alarm-to-action table covering 12 high-priority ventilator alarms, plus a 30-question mixed Domain 2/3 quiz scored at or above 75%.

Week 3

Troubleshooting and Quality Control of Equipment and Infection Control

  • Perform pre-use verification of ventilator, oxygen analyzer, blender, and resuscitation equipment, stating the acceptance criteria for each check.

  • Describe the quality control procedures and corrective steps for blood gas analyzers and other point-of-care devices.

  • Apply standard and transmission-based precautions, hand hygiene indications, and disinfection versus sterilization selection to given scenarios.

  • Troubleshoot leaks, obstruction, and sensor or flow-sensing faults in a ventilator circuit.

Your checkpoint

Written 10-item equipment QC checklist with acceptance criteria for each item and the action taken when a check fails.

Week 4

Troubleshooting and Quality Control of Equipment and Infection Control & Patient Data

  • Sequence the response to a suspected equipment failure so that patient ventilation is maintained during the exchange.

  • Verify and correct a set of recorded patient data (vital signs, SpO2, capnography, hemodynamics) for internal consistency.

  • Identify which data must be gathered and which recommendations must be communicated when a patient's status changes.

Your checkpoint

Timed 60-question cumulative exam across Domains 1-3 scored at or above 75%, with a written remediation list of the three weakest subtopics.

Week 5

Patient Data

  • Interpret arterial and capillary blood gas values, including compensation, and classify acidosis or alkalosis with its primary cause.

  • Obtain and interpret hemodynamic, oximetry, capnometry, and pulmonary function data, and state the clinical significance of each abnormality.

  • Gather and reconcile patient history, physical assessment, and laboratory data to recommend additional diagnostic procedures.

Your checkpoint

20-item blood gas interpretation set completed at or above 90% accuracy using a stepwise interpretation worksheet.

Week 6

Patient Data & Initiation and Modification of Therapeutic Interventions

  • Recommend and modify therapeutic interventions based on reassessed patient data, documenting the rationale for each change.

  • Evaluate the effectiveness of bronchial hygiene, lung expansion, and aerosolized medication therapies using post-therapy assessment data.

  • Decide when to recommend discontinuation or escalation of a therapy using objective criteria.

Your checkpoint

Five written patient scenarios (data to interpretation to recommendation to reassessment) scored at or above 80% each against a rubric.

Week 7

Initiation and Modification of Therapeutic Interventions & Troubleshooting and Quality Control of Equipment and Infection Control

  • Re-drill the subtopics missed on prior practice blocks until each is answered correctly twice in a row.

  • Practice rapid decision-making on timed item sets at 1.5 minutes per question or faster.

  • Rehearse infection control and equipment scenarios inside mixed sets so that domain cues are not predictable.

Your checkpoint

Two 50-question mixed timed sets scored at or above 80% each, with the weak-area log reduced to no more than five remaining subtopics.

Week 8

Patient Data & Troubleshooting and Quality Control of Equipment and Infection Control & Initiation and Modification of Therapeutic Interventions

  • Complete full-length timed simulations under exam conditions and review every missed and flagged item.

  • Consolidate high-yield formulas, normal values, and alarm algorithms into a single review sheet.

  • Verify exam-day logistics and content-outline coverage so that no domain is left unreviewed.

Your checkpoint

Two full-length practice exams scored at or above 80%, plus a completed one-page high-yield review sheet.

Milestones

Week 4: Score at or above 75% on the 60-question cumulative exam and finish all Domain 2 QC and troubleshooting deliverables.

Week 6: Reach at least 85% accuracy on Domain 1 practice items and complete all five written scenario write-ups at 80% or better.

Week 8: Score at or above 80% on both full-length practice exams and hold a complete one-page high-yield review sheet.

NBRC CRT exam day

Your checklist

Government-issued photo ID (needs_review)

Bring at least one current, unexpired government-issued photo ID with a signature. Whether a second form of ID is required and exactly which documents qualify varies by testing vendor and site - confirm the accepted ID list with the testing provider before test day, and make sure the name on your ID matches your registration exactly (including middle name or suffix).

Appointment confirmation / authorization to test

Bring the scheduling confirmation and any authorization-to-test document the vendor or NBRC sent you. Confirm with the provider whether a printed copy is required or whether an electronic copy on a phone is not permitted (phones are typically stored, not carried).

Verified test-center address and route (needs_review)

Look up the exact testing location on the vendor's site a few days ahead - addresses can differ from what a map search shows, and some centers are inside office buildings with limited signage. Plan a primary and backup route, and confirm parking or transit options with the site if unclear.

Arrival buffer

Plan to arrive well before your scheduled start time - commonly about 30 minutes, but confirm the specific check-in window with the testing provider. Late arrival can mean forfeiting your seat and fee under vendor policy.

Plan for prohibited items

Phones, smartwatches, notes, books, and calculators are not allowed at the workstation. Expect to store personal items in a provided locker; keep the key or claim ticket with you. Confirm with the provider what, if anything, may be kept at your desk.

Layered, comfortable clothing

Test rooms are often cool and sessions are long. Dress in layers and avoid items that set off security screening or that you would need to remove and store.

Water and a light snack for breaks

These stay in your locker, not at the workstation. A small protein snack and water help with a multi-hour session. Confirm with the provider whether food and drink are allowed in the building.

Eyeglasses, hearing aids, or other permitted aids (needs_review)

Bring any corrective lenses you normally use for screen reading, plus spare batteries for hearing aids. If you need any accommodation beyond standard testing conditions, it must be requested and approved in advance - contact the credentialing body or testing provider as early as possible.

A one-page personal review sheet

Write a single condensed sheet of high-yield numbers, formulas, and decision rules in your own words. Review it before you enter the building, then leave it in the car or locker - it cannot go into the testing room.

Testing vendor contact information

Save the vendor's phone number and your appointment number in case of a cancellation, weather issue, or site problem. Confirm with the provider how rescheduling works if you cannot attend.

A pacing plan in your head

Know roughly how many minutes you have per question before you sit down (total time divided by total items). Have a checkpoint time in mind - for example, where you should be at the halfway mark - so you can speed up or slow down deliberately.

Plan the day

Final 72 hours

Confirm appointment date, time, location, and ID requirements with the testing provider. Re-read the official content outline and spend remaining study time on your two or three weakest areas only. Shift your sleep schedule so you are alert at your scheduled test time, and stop studying new material by the last day.

Final 72 hours

Do a single timed practice set to rehearse pacing, then review only the explanations for items you missed. Avoid cramming new content that can undercut confidence.

24 hours before

Pack your bag: ID, confirmation documents, layers, snack, water, glasses. Lay out clothes, confirm the route and parking, and check the weather. Do not start new topics. Review your one-page summary once, then stop.

24 hours before

Protect sleep. Aim for a normal full night rather than a short night plus a long cram session. Set two alarms.

Morning of

Eat a normal meal, hydrate moderately, and avoid heavy caffeine if you are not used to it. Leave earlier than the map estimate. Do not study in the waiting area - a last-minute fact check tends to raise anxiety more than it raises your score.

Morning of

At check-in, follow the test administrator's instructions exactly: ID verification, digital signature, photo, and locker storage. Ask the administrator about break rules, scratch materials, and the on-screen calculator if one is offered.

During the test

Read every stem completely and note whether it asks for the best, first, or next action - these qualifiers change the answer. Use process of elimination, and commit to an answer on every item; unanswered items cannot help you.

During the test

Use flag-and-return only if the interface allows review within the section; if you are unsure whether review is permitted, ask before you begin. Watch your checkpoint time and take a brief break if allowed and needed rather than pushing through fatigue.

Rules to check

  • Bring acceptable, unexpired identification. If the name on your ID does not match your registration, or the ID is not on the vendor's accepted list, you may be denied entry and lose your fee. Confirm the exact ID policy with the testing provider in advance.

  • Treat exam content as confidential. Do not record, photograph, reproduce, or discuss specific exam items afterward - most testing agreements prohibit this and violations can invalidate your result.

  • Keep all personal items in the designated storage area. Do not bring notes, phones, smartwatches, or any recording device to the workstation, and do not communicate with other candidates during the session.

  • Break rules and whether the clock continues to run during a break are set by the testing vendor; confirm the specific policy with the provider and with the test administrator at check-in so you can plan your time.

  • Scoring is criterion-referenced and reported on a scaled score with a passing standard set by the credentialing body rather than a simple percentage of correct answers; confirm the current passing standard and score-reporting timeline with NBRC or the provider.

  • There is no penalty for guessing on multiple-choice credentialing exams of this type - answer every question, even when you are uncertain, and mark a best guess rather than leaving items blank.

  • Follow all instructions from the test administrator. Suspected misconduct or failure to comply with testing rules can result in score cancellation or a ban from future testing.

  • If you need testing accommodations, they generally must be requested and approved before your appointment. Confirm the accommodation process and deadlines with the credentialing body or testing provider well before test day.

NBRC CRT FAQ

How many NBRC CRT practice questions are available?

The practice set has 200 NBRC CRT questions. Each one includes the choices, the correct answer, and an explanation, and the set is free to read with no signup.

How many NBRC CRT flashcards are available?

The flashcard set has 32 NBRC CRT cards. Each card shows the term and its definition.

Which topics does the NBRC CRT study material cover?

The NBRC CRT study material covers Patient Data: Gathering, Validating, and Interpreting Clinical Information, Troubleshooting and Quality Control of Equipment and Infection Control, and Initiation and Modification of Therapeutic Interventions.

What format facts does the catalog list for the NBRC CRT exam?

The catalog lists a duration of 180 minutes and these item types: multiple choice for the NBRC CRT exam.